Klipspringer ATFV215 User manual

ATFV215
Reference Precision
Thermometer
Product Code: ATFV215
t/ +44 (0)1473 461 800
e/ service@klipspringer.com
www.klipspringer.com
Klipspringer Ltd
Rynor House, Farthing Road, IPSWICH, UK, IP1 5AP

2
This page is intentionally left blank.

3
TABLE OF CONTENTS
1. INTRODUCTION ..................................................................................... 4
2. CAUTION ................................................................................................ 5
3. OPERATION ............................................................................................ 5
4. BATTERIES ............................................................................................. 6
5. CARE AND MAINTENANCE ..................................................................... 7
6. SPECIFICATIONS ................................................................................... 7
7. DISPOSAL .............................................................................................. 8
8. ASSURANCE ........................................................................................... 7

4
1.0 INTRODUCTION
1.1 Congratulations on your purchase of this Reference precision
thermometer.
1.2 Powered by a x 2 replaceable Battery 1,5 Volt AA –included
1.3 The measuring device is used to measure temperatures in liquids, in air
or in semi-solid (plastic or organic) materials.
Note on the maximum immersion depth:
ATFV215: <140°C maximum 100 mm
ATFV215: >140°C maximum 80 mm
Before you use this product:
1.4 Please make sure you read this instruction manual carefully.
1.5 Following and respecting the instructions in your manual will prevent
damage to your instrument and loss of your statutory rights arising from
defects due to incorrect use.
1.6 Likewise, we take no responsibility for any incorrect readings or for any
consequences resulting from them.
1.7 We shall not be liable for any damage occurring as a result of not
following these instructions.
1.8 Please take particular note of safety advice.
1.9 Please keep this instruction manual for future references.
2.0 CAUTION

5
This product is exclusively intended for the field of application described
above. It should only be used as described within these instructions.
Unauthorized repairs, modifications or changes to the product are
prohibited.
2.1 Keep the instrument and the battery out of reach of children.
2.2 Batteries contain harmful acids and may be hazardous is swallowed.
Batteries must not be thrown into the fire, short-circuited, taken apart or
recharged. Risk of explosion!
2.3 Low batteries should be charged as soon as possible to prevent damage
caused by leaking. Wear chemical-resistant gloves when handling leaking
batteries.
Product safety:
2.4 Do not place the unit near extreme temperatures, vibrations or shocks.
2.5 Do not immerse the display unit in water. Water can penetrate and cause
malfunction.
3.0 OPERATION
3.3 The battery is factory installed, when switched off, the display shows the
battery capacity. The device has two buttons. To switch on, press one of
the two buttons
3.4 The display briefly shows the firmware version and then the current
measured temperature. The temperature sensor is located in the probe
tip. In order to measure the correct temperature, the sensor should be at
least 50mm in the sample to be measured.
3.5 To switch off device, press power key for 2 seconds. Device confirms on
and off with a beep and will flicker for 3 seconds. Device switches to
standby after 10 minutes.
3.6 During normal operation, the measuring device shows the remaining
operating time in minutes and seconds in the right-hand corner of the

6
display. The device switched off after the time has elapsed. A short press
of the power key restarts the counter. This turn-off timer can be
deactivated: while switching the device on, press and hold the power
button for 4 seconds until the beep. The device now shows ∞indicating
continuous operation mode. To deactivate this function, repeat the
process.
3.7 Pressing and holding the mode button takes you to a submenu. The
device remains in the submenu until the mode button is released. It flicks
through menu items every second. To deactivate this function, repeat
process.
3.8 Trend display, measured temperature value is shown in connection with
a trend display
3.9 The permitted device temperature is 32°F –122°F. A separate sensor
measures the device temperature directly behind the display. If the
device temperature exceeds the allowed range, a warning flashes on the
display. Return to regular temperature immediately to avoid damage.
4.0 BATTERIES
4.1 For a long battery life, it is recommended to press the “ON/OFF” button
to switch the instrument off when not in use.
4.2 When the battery is used up, the low battery icon appears.
4.3 Open the battery cover on the rear of the instrument, insert a new
battery and tighten the cover again.
4.4 Replace batteries when the low battery indicator in the right corner of
the display appears. Open battery compartment screw, replace with two
batteries AA 1,5 Volt (LR6). Close batter compartment.
4.5 Battery life approx. 500 hours

7
5.0 CARE AND MAINTENANCE
5.1 Clean the device with a damp cloth.
Do not use any solvents or scouring agents.
5.2 Remove the battery from the device if it will not be used for an extended
period of time.
5.3 Store the instrument in a dry place.
6.0 SPECIFICATIONS
Measuring range
-58°F ±482°F/ -50 ±250°C
Resolution
0.1°/0.01° selectable
Display
Paperwhite display 50 x 26mm
Working temperature
32°F 122VF / 0°C 50°C
Warranty
2 years
Dimension housing
140 x 50 x 22mm
Dimension probe
150 x 4.5mm
Weight
165g
Battery
2 x 1,5 Volt AA (LR6)
Probe type
Fixed probe
Battery life
500 hours
Certification
Free Calibration certificate supplied
7.0 DISPOSAL

8
This product has been manufactured using high-grade materials and
components which can be recycled and reused.
7.1 Never dispose empty batteries and rechargeable batteries in household
waste. As a consumer, you are legally required to take them to your
retail store or to appropriate collection sites depending to national or
local regulations in order to protect the environment.
7.2 The symbols for the heavy metals contained are: Cd=cadmium,
Hg=mercury, Pb=lead.
7.3 This instrument is labelled in accordance with the EU Waste Electrical
and Electronic Equipment Directive (WEEE).
7.4 Please do not dispose of this instrument in household waste.
7.5 The user is obliged to take end-of-life devices to a designated collection
point for the disposal of electrical and electronic equipment, in order to
ensure environmentally compatible disposal.
8.0 ASSURANCE
8.1 With considerate use and Klipspringer’s support, the unit will give
years of accurate service.