Signal Controller TI 96
General Information
Signal Controller TI 96 is a robust, simple, inexpensive unit
which can be installed in all types of vessels. Two types are
available. One type for vessels with more than 100m between
whistles and one type for vessels with less than 100m between
whistles.
TI 96 can be controlled by external push–buttons (see wiring
diagram overleaf).
It must be noted that when the whistle is activated by the
external push–button, the automatics will stop. The external
push–button does not control the lamp output.
Automatic Signalling
The automatics have six signal characters.
All characters can be used for the whistles or the lamp or both
simultaneously.
The period time is always 90 seconds (optional 60 seconds).
The automatics start when the symbol switch is turned to the
required position even if the switch before starting is in the
OFF/RESET position or at another symbol.
The red LED lights steady, when unit in automatic operation.
When a push-button is activated the red LED on the front
starts to flicker, to give the operator the information that the
automatic is stopped.
The automatics switch off in OFF/RESET position.
It can also be switched off by pressing the push–button
HAND. The symbol switch should then be turned to the
OFF/RESET position.
The indicating LED extinguishes when the symbol switch
is in OFF/RESET position only indicating that the Signal
Controller is shut off.
It is also possible to change the symbol (whistle, lamp or
whistle plus lamp) during signalling by turning the symbol
switch direct to the required position. If the automatics have
been shut off via the hand push–button and the symbol
switch still being in the previous position, the automatics
can be re–started with the same symbol by turning the
switch to the nearest position and then quickly back to the
previous position.
Manual Signalling
The push–button HAND is for manual signalling. It shuts off
an “automatic” signal even during signalling. A mains failure
also shuts off the automatics.
The internal push-button control output as per symbol switch.
If the switch is in the position “OFF/RESET” then the HAND
push-button will activate the sound .
Signal Controller TI 96
Please use the following Ref. No. when ordering:
Ref.no. 24510102 90 sec./period time For installation on ships with less than 100m between the whistles (grey)
Ref.no. 24510104 90 sec./period time For installation on ships with less than 100m between the whistles (black)
Ref.no. 24510106 90 sec./period time For installation on ships with more than 100m between the whistles (grey)
Ref.no. 24510107 60 sec./period time For installation on ships with more than 100m between the whistles (grey)
Automatic Signal Controller for whistle and lamp
TYFON®
KSM 475/0648
Ref.no. 24510102
Ref.no. 24510104
Ref.nos. 24510106 / 07
(depending on period time)
Signal Controller TI 96 Technical Data and Dimensions
(mm)
Technical Data
Voltage supply: 9-15,6V DC or 18-31,2V DC
Power consumption: 0,2 - 0,1A
Relay contactor: Max. voltage: 250V
Max. current: 6A
Dimensions: 206 x 116 x 70 (L x H x D)
Weight: 1,7 kg
Cable area: 0,2 - 6 mm2
Max cable diameter: 14 mm
Colour: Grey RAL7035 for Ref. No. 24510102
Grey RAL7035 for Ref. No. 24510106
Grey RAL7035 for Ref. No. 24510107
Black RAL9005 for Ref. No. 24510104
Protection class: IP23
The unit is CE-marked.
Units can be obtained from Kockum Sonics or their representatives.
When ordering, please, give reference number and part name.
164
87
Bulkhead mounting - Rear view
45
25
TI 96
Accessories
Name Ref.no.
Adaptor 230V AC to 12/24V DC 20142030
Adaptor 115V AC to 12V DC 20142031
Fuse for relay contact - 6A slow blow 20556260
Fuse for internal electronics - 1A quick blow
20550100
4 holes
Ø 5,2mm for
mounting to
console
170
Panel mounting
98
95
Panel cutout
188
Wiring diagram
WARNING! ONE SUPPLY ONLY FOR BELOW CON-
TACTS. EITHER +12...24 VDC OR 115/230 VAC
O VDC
+12/24 VDC / 125mA
EXTERNAL MANUAL WHISTLE SWITCH
0 VDC / 115 VAC / 230 VAC
*CONNECT JUMPER ONLY WHEN USING
+12/24 VDC FOR AFT WHISTLE SECTION
+12/24 VDC / 115 VAC / 230 VAC
* THESE JUMPERS ENABLES INBUILDT
SPARK SUPPRESSORS WHEN +12/24 VDC
IS USED FOR LANTERN/WHISTLE.
+12/24 VDC / 115 VAC / 230 VAC
*CONNECT JUMPER ONLY WHEN USING
+12/24 VDC FOR LANTERN SECTION
0 VDC / 115 VAC / 230 VAC
+12/24 VDC / 115 VAC / 230 VAC
0 VDC / 115 VAC / 230 VAC
*CONNECT JUMPER ONLY WHEN USING
+12/24 VDC FOR FORE WHISTLE SECTION
FORE WHISTLE
SECTION
AFT WHISTLE
SECTION
LANTERN
SECTION
1
2
3
4
5
6
7
8
9
10
11
12
13
TI 96
DC
AC
115/230V AC
IMPORTANT!
To meet the requirements for EMC-protection:
• Always use shielded cables.
• Be sure to properly connect the unit to ships ground.
• Connect the cables shield to the units cable clamps.
Only one power supply is permitted. If 115/230V AC is to be used for
TYFON and LANTERN section, an AC/DC adaptor must be used to
supply the TI96 on terminal 1 and 2.
The external manual switch must be able to handle 230V AC.
A - Sound aft
F - Sound fwd
AF - Sound aft and fwd
AFL - Sound aft, fwd
and lamp
FL - Sound fwd and
lamp
AL - Sound aft and
lamp
L - Lamp
SIGNAL CONTROLLER TI 96 HAND
OFF/RESET
Switch for signal
characters
Hand push-button
Indicating lamp
A
F
AF
AFLFL
AL
L
Picture shows panel layout for Ref No. 24510102 and 24510104

Other Kockum Sonics Controllers manuals

Kockum Sonics TYFON Ti98 Specification sheet

Kockum Sonics

Kockum Sonics TYFON Ti98 Specification sheet

Kockum Sonics TLG2000 User manual

Kockum Sonics

Kockum Sonics TLG2000 User manual

Popular Controllers manuals by other brands

LG ABZCA installation manual

LG

LG ABZCA installation manual

Lenovo Intel Ethernet Connection X722 Product guide

Lenovo

Lenovo Intel Ethernet Connection X722 Product guide

Corelis NetUSB-1149.1 user manual

Corelis

Corelis NetUSB-1149.1 user manual

Jung 230061SR operating instructions

Jung

Jung 230061SR operating instructions

Ecler WPNET Series user manual

Ecler

Ecler WPNET Series user manual

Siemens SSA911.01ZB manual

Siemens

Siemens SSA911.01ZB manual

Omron CJ1W-DRM21 Operation manual

Omron

Omron CJ1W-DRM21 Operation manual

HKC HQ-005 RBP Installation, operation & maintenance manual

HKC

HKC HQ-005 RBP Installation, operation & maintenance manual

cashco CA5 Installation, operation & maintenance manual

cashco

cashco CA5 Installation, operation & maintenance manual

Anaheim Automation MICROSTEP DRIVER MDM40001 user guide

Anaheim Automation

Anaheim Automation MICROSTEP DRIVER MDM40001 user guide

Resol DeltaSol C Plus Mounting, Connection, Operation, Troubleshooting, Examples

Resol

Resol DeltaSol C Plus Mounting, Connection, Operation, Troubleshooting, Examples

Fujitsu N6B-0558-B70 quick reference

Fujitsu

Fujitsu N6B-0558-B70 quick reference

Akai MPD26 manual

Akai

Akai MPD26 manual

Storm Manufacturing Buckner Superior Sterling Series Frequently asked questions

Storm Manufacturing

Storm Manufacturing Buckner Superior Sterling Series Frequently asked questions

NOVAK NITRO SERVO REGULATOR manual

NOVAK

NOVAK NITRO SERVO REGULATOR manual

Viking SRC-1 Technical practice

Viking

Viking SRC-1 Technical practice

HomeMatic HM-LC-Dim1T-DR Installation and operating manual

HomeMatic

HomeMatic HM-LC-Dim1T-DR Installation and operating manual

Mitsubishi FX2N-10GM user guide

Mitsubishi

Mitsubishi FX2N-10GM user guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.