Kodiak SXA3000HX Service manual

1
SXA3000HX
Gasoline-Powered
3000 Watt Portable Generator
Operating Instructions and
Parts Manual
Printed in Canada Man-SXA3000HX-01
Dynablast Division
Division of John Brooks Company Limited
Mississauga, Ontario, L5N 7K5

2
Warranty
This product is warranted to be free of defects in materials and workmanship
under normal use and service, for a period of one year from the date of
purchase, when operated and maintained in accordance with the Operating and
Maintenance Instructions supplied with this unit. This warranty does not cover
misuse or negligence.
This warranty is extended only to the original purchaser. Warranty is void if
repairs are attempted by anyone other than an Authorized Service Centre.
If a difficulty develops with the product, you should contact your nearest
Authorized Repair Centre, or JOHN BROOKS COMPANY Ltd. Only these
locations are authorized to make repairs to the product or affect replacement of
defective parts, which will be done at no charge within a reasonable time after
receipt of the product. Units or parts should be returned at the customer’s
expense to the nearest JOHN BROOKS location or Authorized Service Centre.
Pack unit in a strong carton and pad tightly to avoid damage. Damage in-
transit is not covered by warranty. Include original purchase receipt with any
claim (keeping a copy for your files).
JOHN BROOKS COMPANY LIMITED’s liability under warranty is limited to
repair of the product and/or replacement of parts and is given to the purchaser
in lieu of all other remedies including incidental and consequential charges.
There are no express warranties other than those specified herein.
For the nearest Authorized Service Centre call:
(905) 567-9222 in Ontario
or
1-888-881-6667
Fax: 1-800-350-5666

3
Product Specifications
Model
SXA3000HX
Engine
Honda GX160K1VX2
5.5hp
Oil Alert
Yes
Noise Level
81 dB-1m
72 dB-7m
Fuel Tank Capacity
3.7 Litres
Run
-
Time (under half load)
4 Hours
Maximum Output
3000W
Rated Continuous Output
2500W
AC Output
120V
Maximum / Con Amps
21.6A / 19.0A
Circuit Breaker Protection
Yes
Receptacles
2 X
Duplex 115V 20A
GFCI
Dimensions
22” x16 x 16”
Weight
74 lbs
The SXA3000HX has been designed with ease of portability, quiet operation,
dependability and versatility in mind. This generator is powered by Honda’s
proven and reliable GX160 series engine, which features Oil Alert for enhanced
operational reliability.
Ideally suited for camping, boating, farm, household, workshop and
construction usage, the SXA3000HX is perfect when remote or back-up power
is required.
In order to determine the power requirements of the equipment you wish to
operate, please consult the chart below. The ratings indicated are
approximations only. You should always check the start-up and running
wattage requirements of the equipment you intend to use.
Application
Start Watts
Running Watts
S
XA3000
HX
Refrigerator, Freezer 2500 700 C
Toaster - 1050 Y
Microwave - 950 Y
Coffee Maker 1500 850 Y
Washing Machine 2000 750 C
Furnace Fan 1400 700 C
Sump Pump 2500 600 C
TV - 350 Y
Circular Saw 1500 750 Y
Drill 1000 250 Y
Sander 1000 375 Y
Y= Will operate C = Check equipment wattage
Please note that this chart represents a sample of the applications that can be
powered off this generator.

4
Safety Precautions
Careful operation is your best insurance to prevent accidents and mishaps.
Read this section carefully before operating your generator. All operators, no
matter how much experience they have acquired, should familiarize themselves
with the capabilities of this generator and the precautions outlined in this
manual.
1. To prevent electrical shocks, do not operate this generator in the rain or
with wet hands.
2. Do not refuel the engine while it is in operation or is still hot.
3. Do not refuel the engine near open flames, pilot lights, or sparking
electrical devices (e.g. power tools, welders, or grinders)
4. The engine should be refueled in a well-lit area.
5. Avoid fuel spillage.
6. Do not use any other fuel except gasoline (or as specified by the engine
manufacturer).
7. Do not operate the generator near flammable products.
8. Do not operate the generator in areas with poor ventilation. The exhaust
fumes contain carbon monoxide, a poisonous, odorless, invisible gas.
Prolonged exposure can lead to unconsciousness and death.
9. Do not connect the generator to a commercial power line.
10. Do not operate any generator with missing or broken parts. Contact your
dealer for replacement parts.
11. The generator should be grounded in damp or highly conductive
conditions.
12. Do not operate with damaged or defective extension cords, or power
cords. Never operate any electrical equipment with damaged or defective
cords.
13. Always check the engine oil level before starting. Fill as necessary
referring to the Honda Engine Owners Manual for the specified engine
oil.
14. Do not cover the generator while it is in operation. Overheating can
result in damaged equipment.
15. For storage, do not cover the generator until it has completely cooled
down.
16. The ambient temperature should not exceed 100ºF/40ºC.
Before starting, read and understand all safety instructions
included in this manual

5
Starting Operation
1. Locate the generator on flat terrain, away from water hazards and/or
flammable liquids. Check all electrical cords for cracked or exposed
wires. Replace if necessary.
2. Follow the engine starting procedures contained in the Honda Engine
Owners Manual. Once started, allow the engine to reach operational
temperature for a few minutes without applying load on the alternator.
3. Make sure that the appliance is switched off before connecting it to the
generator. Do not move the generator while it is running.
4. Be sure to ground the generator if the connected appliance is grounded.
Failure to ground the generator may lead to electrical shock.
5. If the generator is overloaded, or short-circuited, a breaker switch is
automatically tripped, preventing electrical current from being supplied
to the appliance. Check the appliance to ensure that the start-up wattage
requirements do not exceed the capacity of the generator. Press the reset
button.
Shutdown Procedure
1. Turn off the power switch of the electrical appliance and disconnect from
the generator.
2. Allow the engine to cool down for approximately 3 minutes at no-load.
3. Refer to the Honda Engine Owner’s Manual for engine shutdown
procedures.
4. Remove any mud, dirt or condensation from the generator. Store in a dry
place.
Maintenance and Storage
(Please refer to the Honda Engine Owner’s Manual)
Periodic inspection and maintenance of the Honda engine are essential if a high
level performance is to be maintained. Regular maintenance will also ensure a
long service life. The required service intervals and kind of maintenance to be
performed are described and outlined in the Honda Engine Owner’s Manual.

6
Transportation and Storage
(Please refer to the Honda Engine Owner’s Manual)
When transporting the generator, turn the fuel valve OFF and keep the engine
level to prevent fuel spillage.
When the generator will be stored over long periods, carry out the following
maintenance. (Please refer to the Honda Engine Owner’s Manual)
a) Store the generator in a well-ventilated, low humidity area.
b) Clean each part with an oil-soaked rag.
c) Change the engine oil.
d) Clean the air cleaner.
e) Empty the gasoline from the fuel tank and carburetor.
f) Pull the recoil starter until resistance is felt, leaving the handle in that
position.
Caution: Never use water to clean the generator.
Troubleshooting
The majority of problems with generator units are with the engine. Please refer
to the Honda Engine Owner’s Manual if engine problems arise. If the problem
persists, contact your local Honda Equipment Dealer.
Trouble Cause Remedy
Engine fails to start. Low fuel level
Fuel strainer cock
closed.
Spark plug loose or
dirty.
Refill the fuel take making sure
not to overfill.
Open fuel strainer cock.
1. If loose, push spark plug
cap back into place.
2. Remove the spark plug and
clean the electrode.
Generator fails to
generate power. No-fuse breaker is in
the “off” position.
Terminal has loose
connections.
Ensure that the total wattage of
the electrical appliance is within
permissible limits and that there
are no defects with the
appliance. Turn the no-fuse
breaker to the “on” position.
Inspect and secure connections.
Voltage is too low. Engine speed is too
low. Increase engine speed to rating-
refer to the Honda Engine
Manual.

7
SXA3000HX Parts Breakdown

8
SXA3000HX Wiring Diagram
GFCI
Receptacles
Table of contents
Other Kodiak Portable Generator manuals

Kodiak
Kodiak SXB12000HXV Series User manual

Kodiak
Kodiak SXD5000HX User manual

Kodiak
Kodiak KD5000D User manual

Kodiak
Kodiak SGB12000HX Service manual

Kodiak
Kodiak KD3000VR User manual

Kodiak
Kodiak SXA1900HX User manual

Kodiak
Kodiak SGB12000HX User manual

Kodiak
Kodiak SGA1900HX Manual

Kodiak
Kodiak SGA2300GC Service manual

Kodiak
Kodiak SXA1900HX Manual
Popular Portable Generator manuals by other brands

Tektronix
Tektronix AWG5012 instructions

Generac Power Systems
Generac Power Systems GP7000E GP SERIES specification

Mase
Mase IS 2500 installation manual

Generac Power Systems
Generac Power Systems 005796-0 (XG6500) specification

McGraw-Edison
McGraw-Edison Onan GenSet 3.ORDJA installation guide

WARRIOR
WARRIOR 6000S operating manual