KOKEN LM-109MA User manual

Male
Catheterizationand
EnemaSimulator
(Strap-ontype)
LM-109MA
InstructionManual
ThankyouforpurchasingtheMaleCatheterizationandEnemaSimulator(Strap-ontype).
Pleasereadthisinstructionmanualcarefullytoensurecorrectuseoftheproduct,
andstoreitinasafeplaceforeasyaccess.
KOKENCO.,LTD.
1-4-14Koraku,Bunkyo-ku,Tokyo112-0004JAPAN
URL:http://www.kokenmpc.co.jp
E-mail:[email protected]
©2016-2020KOKENCO.,LTD.C-1-1025-1-01-06

1
Handling and Safety Precautions
These precautions should be strictly observed in order to ensure safe,
long-term use of the product.
The following precautions should be observed particularly strictly:
1. Thissimulatorismadetohavethesamefeelasthatofalivingbody.Unduehandlingmaycause
breakageofthesimulator.
2. Thismodelhasadistinctiveodorresultingfromthematerialsitismadefromhoweverisnot
harmfultothebodyorindicateanyproblemwithquality.Thisdistinctiveodorwillweakenover
time.Theproductisalsocoatedinbabypowderatthetimeofmanufactureandthesmellof
babypowdermayremainontheproduct.
3. Thesimulatorreproducestheresistanceofthebulbarurethra.
Wheninsertingthecatheter,ifthepenisisloweredtoananglelessthanabout60degrees,the
insertionofthecathetermaybedicult.Accordingly,pleaseholdthepenisatanangleofabout
60degrees.
4. Whenyoupracticecleaningordisinfectingofthepubicarea,pleaseusewater.Useofalcohol
maycausebreakageofthesimulator.
Useofcoloreddisinfectantliquidmaycausepigmenttobefixedtothesimulatorsothatthe
pigmentcannotberemoved.
5. Asforthelubricant,pleaseuseK-Ytmlubricatingjelly.PleasedonotuseK-Y®gel,asitmay
increasetheinsertionresistanceofthecatheter.
6. Pleasedonotuseoilylubricant(oliveoiletc.),alcohollubricant,andlubricantcontainingorganic
solvent.Thesemaycausebreakageofthesimulator.
7. Pleaseusecathetersof14Frand16Fr.
8. Pleasecheckthestateofthecatheterbeforeinsertingthecatheter.Pleasedonotuseacatheter
thatisdegradedordeformed.Suchacatheterisdiculttoinsert.
9.Wheninsertingthecatheter,pleaseapplythelubricanteachtime.
10.Ifitisdiculttoinsertthecatheter,pleaseincreasetheamountofthelubricanttobeapplied
oruseanothercatheter(firmsiliconecatheterorcatheterwiththinnerbaloonpartetc).The
simulatormaybreakifsuchacatheterisforcedtobeinserted.

2
11.Whenindwellingthecatheter,pleaseinatetheballoonafterinsertingthecatheterapartfrom
theballoonendportionbyadistanceequaltoorgreaterthan23cm.Indwellingofthecatheter
inanintermediateofthevalvecausesthevalveandthecathetertobebroken.
12.Iftheinsertionofthecatheterisrepeatedapluralityoftimes,watermayaccumulateinthe
urethralcanal.Ifthesimulatorisusedinsuchastate,watermayleakthroughtheurethralexit.
Pleaseslantthesimulatorsuitablytodrainthewater.
13. Afteruse,pleasewashthesimulatorandthecatheterwellwithwater.Ifthelubricantdriesand
hardens,itmayinterferewiththeuseofthesimulator.
14.Pleasecheckthestateofthevalveateveryuse.Ifthevalveisbroken,itmaycausealeakageof
water.
15.Oilcomponentsmaycomeoutofthegenitalskin.Afteruse,pleasedonotkeepthegenitalskin
attachedtothesimulator.Pleasewrapitincookingpaper,gauze,etc.,putitintoanattached
reclosablepolybag,andkeepit.Foradetailedstoragemethod,pleaserefertothewashingand
storagemethodsonpage14.
16.Applycommerciallyavailablebabypowdertoreducefrictionifyoumindstickinessofthegenital
skinorafteritiswashedwithwaterfollowinguse.
17.Pleasecheckthestateofthegenitalskineverythreeyearsasareference,andexchangeit
accordingly.
18.Pleasedonotplaceobjectsonthesimulator.Otherwise,thesimulatormaybedeformed.
19. Pleasedonotkeepthesimulatorincontactwithprintedmatter.Print,suchasletters,may
transfertothesimulatorandbexedthere.
20.Whenstoringthesimulator,pleaseselectaplacethatisnotsubjecttodirectsunlightand
ultravioletrays.
21.Thisproductisintendedforuseinstandardoperatingenvironments.Donotuseitinheavy
industrialsettings.
22.Thismodelusesurethanefoamforsomeofitsparts,andmaybesusceptibletodamagefrom
peststhatareattractedtourethanefoam(suchasinsectsintheantfamily).
Whenstoringthismodel,ensurethatthoroughmeasuresaretakentopreventpestdamage
beforestoring.Thecompanywillnotbeinvolvedwithorheldliableforpestdamagethatoccurs
duringstorage.
1.Thecontentsofthisinstructionmanualaresubjecttochangewithoutnotice.
2.Thisinstructionmanualmaynotbereproducedinpartorinitsentiretywithoutpermission.
3.Pleasecontactthemanufacturerintheeventthatanyerrorsoromissionsarefoundinthecontentsof
thisinstructionmanual.
4.Thisproductshouldbeusedonlyasdescribedinthisinstructionmanual.Inparticular,theproduct
shouldnotbeusedinanywaythatcontravenestheprecautionsnotedintheinstructionmanual.

3
Table of Contents
1. Outline and Features
2. Components and Conguration
3. Handling Method
4. Washing and Storage Methods
5. Specications
6. Replacement Parts (Sold Separately)

4
1. Outline and Features
Outline
Thesimulatorcanbemountedonahumanbodyoradollsothataseriesoftechniquesregarding
catheterizationandenemacanbepracticed.Thefeelofthepenisiscloselysimilartothatofaliving
bodypenis.Ifacatheterizationcatheterisappropriatelyinserted,urine(water)owsout.
Features
・Thesimulatorisofanactualsizebywhichacatheterizationandglycerineenemaforanadult
malecanbepracticed.
・Sincethesimulatorisofastrap-ontype,itcanbemountedonahumanbodyoramodeldoll
sothatthepracticecanbeperformed.
・Bymountingthesimulatoronahumanbody,thefeelingofapatientcanbesimulated.
Also,bymountingthesimulatoronasimulationpatient,techniquescanbepracticedwhile
communicatingwiththesimulationpatient.
・Sincesoftandstretchablematerialsareusedforthepubicarea,theappearanceandfeelare
realistictogivepresencewhenpracticing.
・Aseriesoftechniquesofcatheterizationsuchasdisinfectingofapubicarea,andinsertingand
removingofacathetercanbepracticed.
・Techniquessuchaspeelingoftheforeskin,disinfectingandcleaningcanbeperformed.
・Themotionofthepenisisalsoclosetothatofalivingbodypenis.Thesimulatoriscongured
suchthatitisdiculttoinsertthecatheterifthepenisisnotraisedappropriately.
・Theattachedglycerineenematorcanbeinsertedthroughtheanustotherectum.Thisenables
thepracticefortheglycerineenema.

5
2. Components and Conguration
1. Urethralpart
2. MaleGenitalskin
3. BladderValve(Male/Female)
4. O-ring
5. Strap-ontypeframe
6. Bladdertube
7. Strap-ontyperectumconnecting
connector
8. Bagforirrigator
9. Tubeforirrigator
10.Draintube
11. Glycerineenemator
Storagebag
Instructionsmanual(thispamphlet)

6
3. Handling Method
3-1AssemblingofSimulator
1. Pleaseconnectthebagforirrigatortothebladdertube,andputwaterintothebagfor
irrigator.Pleaseopenaclamp,llthebladdertubewithwater,closetheclamp,andattach
thebladdervalvetothebagforirrigator.
2.Pleaseapplylubricanttothedistalendoftheglansandinsertitintothegenitalskin.
Pleasecheckthattheglansisnottwistedandthenxtheurethralpartandthegenitalskin
withhookandloopfasteners.
Checkwhether
ornottheglans
istwisted.

7
3.Pleaseinserttheurethralpartofthegenitalskinintothestrap-ontypeframe.
4.Pleaseinsertthestrap-ontyperectumconnectingconnectorintothestrap-ontypeframe,
andputtheanalportionofthegenitalskinonthestrap-ontyperectumconnecting
connector.Aftertheconnectorisinserteddeepintotheanalportion,pleasetandxthe
positionofthegenitalskintothestrap-ontypeframe.
5.PleaseinserttheO-ringintotheconnectoroftheurethralpart,andconnectittothebladder
tube.

8
6.Pleaseconnectthestrap-ontyperectumconnectingconnectortothedraintube.
3-2WearingMethod
1.Pleaseremovethefrontbeltandrearbeltfromthewaistbelt.
2.Pleasewearthewaistbeltandadjusttheadjusteraccordingtowaistsize.

9
3.Pleasepassthefrontbeltthroughthewaistbelt,andtandxthepositionofthepubicarea
withhookandloopfasteners.
4.Pleasepasstherearbeltthroughthewaistbelt,andxitwithhookandloopfastenerssuch
thatthebeltsdonotcomeloose.
5.Whenperforminganenematechnique,pleaseremovethefrontbeltonce,tthepositionof
theanustothebody,andadjustthelengthoftherearbeltrst.
CaseofCatheterization
CaseofEnema

10
3-3InsertionofCatheterizationCatheter
1.Pleaseputwaterintothebagforirrigator,opentheclamp,andcheckwhetherornotthe
waterleaksfromthesimulator.
2.Pleaselowertheforeskin,exposetheglans,anderectthepenisatabout90degrees.
*Whenpracticingthecleaningordisinfectingofthepubicarea,pleaseusewaterinsteadof
disinfectionliquid.
3.Pleaseapplylubricantonthedistalendofthecatheterforabout4to5cmandinsertthe
catheter.Ifyoufeelresistance,pleaseslantthepenisforwardatabout60degrees,and
advancethecathetersuchthatyouslightlydrawthepenistoyourself.
*Intermediateresistancereproducesresistanceofthebulbarurethra.
*Thesimulatorisconguredsuchthatitisdiculttoinsertthecatheterifthepenisis
loweredtoananglelessthanabout60degrees.
*Ifitisdiculttoinsertthecatheter,pleasecheckthetechniquesandinsertitagain.Inthis
case,pleaseremovemoisturefromthecatheterandincreasetheamountofthelubricant
tobeapplied.Also,pleaseconsiderusingothertypesofcatheters(rmsiliconecatheteror
catheterwiththinnerbaloonpartetc).Thesimulatormaybebrokenifhecatheterisforced
tobeinserted.
About60degrees

11
*Ifitisdiculttoinsertthecatheter,pleaseusewatermixedwithasmallamount
(approx5%)ofsurfactant(neutraldetergent)asurine.
*Iftheinsertionofthecatheterisrepeatedapluralityoftimes,watermayaccumulateinthe
urethralcanal.Ifthesimulatorisusedinsuchastate,watermayleakfromtheurethral
exit.Pleaseslantthesimulatorsuitablytodrainthewaterthroughtheexternalurethraexit.
4.Pleasechecktheoutowoftheurine(water).Ifurinedoesnotowout,thecathetermayfail
topassthroughthevalve,theclampofthebagforirrigatormayfailtoopen,ortheamountof
waterinthebagforirrigatormaybereducedtoasmallamount.
5.Whenindwellingthecatheter,pleaseinatetheballoonafterinsertingthecatheterapart
fromtheballoonendportionbyadistanceequaltoorgreaterthan23cm.Indwellingofthe
catheteratanintermediateofthevalvecausesthevalveandthecathetertobebroken.
6.Oncethecatheterisinserted,pleaseremovethemoisturefromitswettip,applythelubricant
eachtime,andtheninsertthecatheter.Ifthelubricantisappliedwherewaterremains,the
lubricantslideseasilyoofthecatheter.Thismakesitdiculttoinsertthecatheter.
3-4Enema
1. Pleaseprepareabucketetc.underadeskorabedandputthedistalendofthedraintubeinit.
2.Pleasetandxthepositionoftheanusofthestrap-ontypeframetothebody,andadjustthe
lengthofthebelt.
3.Pleaseapplylubricanttothedistalendofaglycerineenemator,insertitintotheanus,andpour
enemaliquid(water)intoit.Atthistime,pleaselowerthedistalendofthedraintubetoa
positionbelowtheanus.Otherwise,theenemaliquid(water)mayowbackwardandstain
clothing.
3-5Removal
1. Pleaseremovethefrontbeltfromthewaistbelt,removethewaistbelt,andremovethe
strap-ontypeframe.

12
2.Pleaseclosetheclampofthebagforirrigatorandremovethebagfromthebladdertube.
3.Pleaseremovethedraintubefromthestrap-ontyperectumconnectingconnector.
*Pleasepayattentiontotheoutowofthewater.
4.Pleaseremovetheconnectorforconnectingtheurethralpartandthebladdertube.
*Atthistime,pleasepayattentiontoalossoftheO-ring.
5.Pleaseremovethebladdervalvefromthebladdertube,anddrainthewaterinthetube.

13
6.Pleaseremovethegenitalskinfromthestrap-ontypeframe.
Atthistime,pleaseremoveslowlywhileholdingtheareaofthehookandloopfastenerso
thatitdoesnotpeelofromthegenitalskin.
7. Pleasepullthegenitalskinoutofthestrap-ontyperectumconnectingconnector,
andremovethestrap-ontyperectumconnectingconnectorfromthestrap-ontypeframe.
8.Pleaseremovetheurethralpartfromthegenitalskin.
9.Pleasewashtheurethralpart,thebladdervalve,thebladdertube,thegenitalskin,
andthestrap-ontyperectumconnectingconnectorwellwithwaterafteruse.

14
4. Washing and Storage Methods
1. Pleaseushthelubricantthathasadheredtotheurethralpart,thebladdervalve,thebladder
tube,etc.wellwithwater.Ifthelubricantdriesandhardens,itmayinterferewiththeuseof
thesimulator.
2.Pleaseremovemoisturewell,drythesimulatorandthenputitintoastoragebag.
3.Oilcomponentsmaycomeoutofthegenitalskin.Afterusingthesimulator,pleasedonot
keepthegenitalskinattachedtothemainbody.Pleasewrapitincookingpaper,gauze,
etc.,putitintoanattachedreclosablepolybag,andkeepittherein.Pleasewrapthegenital
skingentlysuchthatwrinklesarenotgeneratedonit.
4.Pleaseapplybabypowderthatiscommerciallyavailable,ifyoumindstickinessofthe
genitalskin.
5. Asforstainsonthesimulator,pleaseuseneutraldetergentthatiswatereddownandwipe
othestainswithwetgauzeetc.
*Pleasedonotusesolventssuchasthinnerandbenzene.

15
5. Specications
6. Replacement Parts (Sold Separately)
Length Width Height Weight
MainBody
StorageBag
Approx.23cm Approx.13cm Approx.18cm Approx.0.7kg
Approx.21cm Approx.47cm Approx.24cm
Productname
Bagforirrigator(3pcs/set) LM-025J
Tubeforirrigator(3pcs/set) LM-025H
Productname ProductNo.
MaleGenitalskin LM-109MB
BladderValve(Male/Female) LM-109V
Glycerineenemator(withcap/5pcs) LM-0686
Table of contents
Other KOKEN Educational Equipment manuals
Popular Educational Equipment manuals by other brands

hand2mind
hand2mind STEM Lab Makerspace Cart Getting started guide

Talk To Me Technologies
Talk To Me Technologies wego A user guide

LEXIBOOK
LEXIBOOK CR550 Series instruction manual

Horizon Fitness
Horizon Fitness HYDROFILL user guide

Nasco Healthcare
Nasco Healthcare Auscultation Trainer instruction manual

Educational Insights
Educational Insights Circuit Explorer Rocket Mission guide