konf Aculas-AM User manual

(Membrane)


1
2
3
4
5
11
12
13
14
Front Panel
LCD Display
Rear Panel
Preparation Steps
Operation Steps
Using Aculas-AM
Tips and troubleshooting
Learning more, service and support
Safety and cleaning

Front Panel
Power Switch
Select All Channels
Repeat Last Therapy
or Select Pre-program
Numerical Data
Input
Channel Selection
Time Setting
Pulse Selection
Start Therapy
Pause
Reset
Set
Alarm Music Silence

Pause
Pulse Output
Continuous
Output
Fault
Pulse Frequency
Time(Min.)
Channel
LCD Display

Rear Panel
Maximum Output 100 mW
Wavelength 660~980 nm
CLASS IIIb LASER PRODUCT
Power Cable
Remote Pause Socket
Laser Module
Socket

Maximum Output 100 mW
Wavelength 660~980 nm
CLASS IIIb LASER PRODUCT
1
2
3
Preparation Steps
Preparation
STEP ACTION DESCRIPTION Illustration
Connect laser modules
to rear panel with screw
driver
3
Connect AC power
to rear panel
Connect Power
2Connect
Remote
Pause Switch
(If available)
Connect pause switch
to rear panel
1
Connect Laser
Module

Operation Steps
OPERATION
STEP ACTION KEY IN LCD DISPLAY REMARKS
Backlite ON
Ch. 1
Set
Set
ALL
Ch.
Time 0
3Set
Power ON
Select Channels
Combination
Select All
(10) Channels
Time Setting
1
2-a
2-b
3
Min
CH.
1 2 3 4 5 6 7 8 9 10
CH.
1 2 3 4 5 6 7 8 9 10
CH.
1
Time Setting:
1 ~ 60 Min.
Select Others:
2, Set;
3, Set;
-----
Note: Key-in Once Ch.
only
2
3Set
Set

Set
Operation Steps
OPERATION
STEP ACTION KEY IN LCD DISPLAY REMARKS
Select
Continuous
Wave Output
Select Pulse
Output
Pulse
Frequency
Setting
Autos to
Stand-by Mode
after 3 Seconds
4-a
4-b
5
6
Freq.
100 0 Setting Range:
1 ~ 1000 Hz
Min
Hz
CH.
1 2 3 4 5 6 7 8 9 10
Min
CH.
1 2 3 4 5 6 7 8 9 10
Min
Hz
CH.
1 2 3 4 5 6 7 8 9 10
Min
Hz
CH.
1 2 3 4 5 6 7 8 9 10
No Need
No Need

Operation Steps
OPERATION
STEP ACTION KEY IN LCD DISPLAY REMARKS
Start
Start Therapy
Pause
C
Start
Alarm Music
Silence
Remote Pause
7
Restart after
Pause
Pause from
Front Panel
Time Count to
Zero
Alert Music No.2
(Plays 15 Sec.)
Alert Music No.1
Min
Hz
CH.
1 2 3 4 5 6 7 8 9 10
Flash
Flash
Min
Hz
Pause
CH.
1 2 3 4 5 6 7 8 9 10
Flash
Min
Hz
CH.
1 2 3 4 5 6 7 8 9 10
Flash
Flash
Min
Hz
CH.
1 2 3 4 5 6 7 8 9 10

Operation Steps
OPERATION
STEP ACTION KEY IN LCD DISPLAY REMARKS
Reset All
Parameters
Repeat the
Last Therapy
Power OFF
Alert Music No.3
Fault
Reset
Prog.
Start
Min
Hz
CH.
1 2 3 4 5 6 7 8 9 10
Min
Hz
Fault
CH.
1 2 3 4 5 6 7 8 9 10
Flash
Flash

REMARKS
Pre-progammed
LCD DISPLAY
KEY INACTION
STEP
OPERATION
Program Setting
Min
Hz
CH.
1 2 3 4 5 6 7 8 9 10
Min
Hz
CH.
6 7 8 9 10
Min
Hz
CH.
1 2 3 4 5
Min
Hz
CH.
1 2 3 4 5 6 7 8 9 10
Set
2
Prog.
Set
1
Prog.
Set
Prog.
Start
2
Prog.
Start
1
Prog.
Start
Prog.
CH.:
Time:
Hz:
CH.:
Time:
Hz:
CH.:
Time:
Hz:
Change
Program
Parameters
Execute
Program-2
Execute
Program-1
Execute
Program-0

Progammed
Parameters
LCD DISPLAY
KEY INACTION
STEP
OPERATION
Program Setting
Hz
Min
CH.
1 2 3 4 5 6 7 8 9 10
Hz
Min
CH.
1 2 3 4 5 6 7 8 9 10
Set
1
Prog.
Start
1
Prog.
CH.: 1 ~ 10
Time: 30
Hz: 10
Change
Program-1
Parameters
Execute
Program-1
Time 0
3Set
Freq. 10Set
Start
Set
ALL
Ch.
After Start
Switch Power OFF
10

Laser module taping instruction
Laser shower instruction
Using Aculas-AM
Aculas-AM can be used for treatment of diseases and conditions, follow the recommended
dosage and treatment time to get the best efficacy. You can also find new information about
using Aculas-AM on the web .www.konftec.com
11

My Aculas-AM won't turn on
Make sure Aculas-AM's power switch is on.
If that doesn't work, check the connection from Aculas-AM to the Aculas-AM power
adapter and connect the adapter to a working electrical outlet.
If that doesn't work, contact your local sales office.
My Aculas-AM is flashing fault sign and is continuously playing music
then reconnect the laser module.Turn off the power switch
Repeat the operation steps:
1. Turn on Aculas-AM's power switch.
2. Press (program) button to set the last therapy protocol. "Prog"
Wait 3 seconds until the circles of CH. (channel) appear.
3. Press button to begin the therapy."Start"
If that doesn't work, you can still temporarily use the working channels by deleting the
faulty channel.
Refer your Operation Manual for detailed operation steps.
Contact your local sales office.
Tips and troubleshooting
Read on for advice about using and troubleshooting Aculas-AM.
12

Learning more, service, and support
There is a wealth of information about using Aculas-AM on the web.
For the latest information on Aculas-AM service and support information go to
www.konftec.com.
Obtaining warranty service
If the product appears to be damaged or does not function properly, please follow the
advice in this booklet, and the online resources. If the unit still does not function, go to
www.konftec.com for instructions on how to obtain warranty service.
13

Important safety instructions
When setting up and using your Aculas-AM, remember the following:
Read user’s guide carefully before you plug your Aculas-AM Power Adapter into a power
outlet.
Keep user’s guide handy for reference by you and others.
Follow all instructions and warnings dealing with your Aculas-AM.
Electrical equipment may be hazardous if misused.Warning:
Operation of this device, must always be supervised by an adult. Do not allow children access
to the interior of any electrical product and do not permit them to handle any cables.
Warning: Laser beam
Avoid direct eye exposure to the laser beam.
Because some Aculas-AM lasers emit invisible infrared light, the usage of laser shower or
handheld unit in the area of the face and around the eyes must proceed with appropriate care
and caution. Invisible infrared laser light penetrating the eye may cause serious harm after
extended exposure. Therefore, the use of the optional laser safety goggles for the patient and
clinician is advised.
Safety and cleaning
Read on to learn about using Aculas-AM safely and cleaning Aculas-AM.
14

40
0
Using the power adapter
Use only the power adapter that came with your Aculas-AM. Adapters for other electronic
devices may look similar, but they may damage your Aculas-AM.
The only way to shut off power completely to your power adapter is to disconnect it from the
power source.
When connecting or disconnecting your power adapter, always hold the power adapter by
its sides. Keep fingers away from the metal part of the plug.
Before connecting the laser module cable to the power adapter, make sure there are no
foreign objects inside the adapter's port.
The power adapter for your Aculas-AM is a high-voltage component and should not be
opened for any reason, even when the Aculas-AM is off. If the power adapter needs service,
see “Learning more, service and support.”
About operating and storage temperatures
Operate your Aculas-AM in a place where the temperature is always between 0 and 40º C
(32 to 105º F).
Store your Aculas-AM in a place where the temperature is always between -20 and 85º C (-
4 to 185º F).
When you are using your Aculas-AM, it is normal for the bottom of the power supply case to
get warm.
15

Avoid wet locations
Warning
To reduce the chance of shock or injury, do not use your Aculas-AM in or near water or wet
locations.
Keep your Aculas-AM and power adapter away from sources of liquids, such as drinks, wash
basins, bathtubs, shower stalls, and so on.
Protect your Aculas-AM and the power adapter from direct sunlight and rain or other
moisture.
Take care not to spill any food or liquid on Aculas-AM or its power adapter. If you do, unplug
Aculas-AM before cleaning up the spill.
Depending on what you spilled and how much of it got into your equipment, you may have to
send your equipment to Konftec for service. See “Learning more, service, and support.”
Do not make repairs yourself
Warning
Do not attempt to open your Aculas-AM or power adapter, disassemble it. You run the risk of
electric shock and voiding the limited warranty.
No user-serviceable parts are inside.
For service, see “Learning more, service, and support.”
Cleaning
Follow these general rules when cleaning the outside of your Aculas-AM and its components:
Make sure your Aculas-AM is unplugged.
Use a damp, soft, lint-free cloth. Avoid getting moisture in openings.
Don't use aerosol sprays, solvents or abrasives.
About handling
Your Aculas-AM may be damaged by improper storage or handling.
Be careful not to drop your Aculas-AM when treating or transporting the device.
16

www.konftec.com
© 2014 Konftec Corporation. All rights reserved.
Konf, the Konf logo, Aculas, and Aculas-AM
are trademarks of Konftec Corporation,
registered in Taiwan and
other countries.
UAMM_40601E
Konftec Corporation
12F-7, No.77, Sintai 5th Rd., Sec. 1,
Sijhih District, New Taipei City 221
Taiwan
Table of contents