Kostal Smart Energy Meter User manual

Homepage_Cover
Operating manual
KOSTAL Smart Energy Meter

2
© 2020 KOSTAL Solar Electric GmbH
Legal notice
KOSTAL Solar Electric GmbH
Hanferstraße 6
79108 Freiburg i. Br.
Germany
Phone +49 (0)761 477 44 - 100
Fax +49 (0)761 477 44 - 111
www.kostal-solar-electric.com
Exclusion of liability
All names, trademarks, product names or other designa-
tions used in this manual may be legally protected even
if not indicated as such (e.g. as a trademark). KOSTAL
Solar Electric GmbH assumes no liability or warranty for
their free usage. The illustrations and texts have been
compiled with great care. However, the possibility of
errors cannot be ruled out. The compilation is made
without any guarantee.
General note on gender equality
KOSTAL Solar Electric GmbH is aware of the impor-
tance of language with regard to the equality of women
and men and always makes an eort to reflect this in
the documentation. Nevertheless, for the sake of read-
ability we are unable to use non-gender-specific terms
throughout and use the masculine form instead.
© 2020 KOSTAL Solar Electric GmbH
All rights reserved by KOSTAL Solar Electric GmbH,
including those of reproduction by photocopy and stor-
age in electronic media. Commercial use or distribution
of the texts, displayed models, diagrams and photo-
graphs appearing in this product is not permitted. This
manual may not be reproduced, stored, transmitted or
translated in any form or by means of any medium, in
whole or in part, without prior written permission.
Valid from version: 1.3.0
2
3
4
5
1

3
© 2020 KOSTAL Solar Electric GmbH
1. General information 5
1.1 Proper use ................................................................................................................................. 7
1.2 EU declarations of conformity ................................................................................................... 10
1.3 About this manual .................................................................................................................... 11
1.4 Notes in this manual ................................................................................................................. 13
1.5 Symbols used .......................................................................................................................... 17
1.6 Labels on the energy meter ...................................................................................................... 18
2. Device and system description 19
2.1 Using the KOSTAL Smart Energy Meter .................................................................................... 20
2.2 The KOSTAL Smart Energy Meter ............................................................................................. 21
2.3 LED statuses ............................................................................................................................ 22
2.4 Functions ................................................................................................................................. 23
3. Connection variants 27
3.1 The KSEM with the PLENTICORE plus ..................................................................................... 28
3.2 The KSEM with the PLENTICORE BI ........................................................................................ 34
3.3 The KSEM with the PIKO IQ .................................................................................................... 37
3.4 The KSEM with the PIKO MP plus ........................................................................................... 41
3.5 The KSEM with the PIKO 4.2-20 / PIKO EPC ........................................................................... 50
3.6 The KSEM with the PIKO CI ..................................................................................................... 53
3.7 Multiple-inverter connection of KOSTAL inverters ...................................................................... 56
3.8 Configuring settings in the Webserver ...................................................................................... 66
4. Operation 67
4.1 The Webserver ......................................................................................................................... 68
4.2 Preparing KOSTAL Smart Energy Meter .................................................................................... 69
4.3 Calling up user interface ........................................................................................................... 70
4.4 Configuring settings ................................................................................................................. 71
4.5 The dashboard ......................................................................................................................... 72
4.6 Menu - smart meter .................................................................................................................. 73
4.7 Menu - tari.............................................................................................................................. 75
4.8 Inverter menu ........................................................................................................................... 78
4.9 Menu - Modbus settings .......................................................................................................... 88
4.10 Menu - device settings ............................................................................................................. 95
Contents
2
3
4
5
1

4
© 2020 KOSTAL Solar Electric GmbH
General information
5. Faults / maintenance 103
5.1 Functions of the Reset button ................................................................................................. 104
5.2 Error messages / displays ...................................................................................................... 105
5.3 Exporting log data .................................................................................................................. 107
5.4 Updating device firmware ....................................................................................................... 108
5.5 Change password .................................................................................................................. 109
Index 110
2
3
4
5
1

5
1.
Navibutton Verlinkung Kapitel 01
© 2020 KOSTAL Solar Electric GmbH
1. General information
1.1 Proper use .................................................................................................................................. 7
1.2 EU declarations of conformity ................................................................................................... 10
1.3 About this manual ..................................................................................................................... 11
1.4 Notes in this manual ................................................................................................................. 13
1.5 Symbols used ........................................................................................................................... 17
1.6 Labels on the energy meter ...................................................................................................... 18
1
2
3
4
5
1

6
© 2020 KOSTAL Solar Electric GmbH
General information
Thank you for choosing our KOSTAL Smart Energy
Meter (KSEM) from KOSTAL Solar Electric GmbH!
We hope you enjoy consistently high energy yields with
your photovoltaic system.
If you have any technical questions, please call our
service hotline:
n Germany and other countries
1
+49 (0)761 477 44 - 222
n Switzerland
+41 32 5800 225
n France, Belgium, Luxembourg
+33 16138 4117
n Greece
+30 2310 477 555
n Italy
+39 011 97 82 420
n Spain, Portugal
2
+34 961 824 927
1Language: German, English
2Language: Spanish, English
1
2
3
4
5
1

7
© 2020 KOSTAL Solar Electric GmbH
General information
1.1 Proper use
The KOSTAL Smart Energy Meter is a measuring device,
which determines electrical measuring values and is
available to the inverter via LAN or RS485. It is not an
electricity meter for measuring active consumption in the
sense of the EU Directive 2004/22/EC (MID) and it may
only be used for internal purposes.
The data about your system’s energy generation col-
lected by the KOSTAL Smart Energy Meter may deviate
from the data of the main energy meter.
According to its classification as overvoltage category III,
the KOSTAL Smart Energy Meter may only be connected
in the sub-distribution / circuit distribution on the con-
sumer side behind the energy supply company’s energy
meter and is only suitable for indoor use.
The KOSTAL Smart Energy Meter is approved for use in
EU member states. Only use the KOSTAL Smart Energy
Meter in accordance with the details provided in the
enclosed documentation.
Any other form of use may result in damage to prop-
erty or personal injury. For reasons of safety, the prod-
uct (including the software) must not be modified and
components must not be fitted if they are not expressly
recommended or sold by KOSTAL Solar Electric GmbH
for this product. Any form of product use other than that
described in the intended use section is not considered
to be intended.
Operators are prohibited from undertaking unauthorised
changes, conversions and repairs as well as opening the
product.
The enclosed documentation forms part of the prod-
uct and must be read, noted and kept accessible at all
times.
1
2
3
4
5
1

8
© 2020 KOSTAL Solar Electric GmbH
General information
Exclusion of liability
Any use that diers from that described in the “Proper
use” chapter or goes beyond the stated intended pur-
pose is considered inappropriate. The manufacturer
accepts no liability for any damage resulting from this.
Modifications to the energy meter are prohibited. The
energy meter may only be used if it is safe to operate
and is in a technically perfect condition. Any instance of
misuse will result in the termination of the warranty, guar-
antee and general liability of the manufacturer.
Only a qualified electrician may open the device. The
device must be installed by a trained electrician (accord-
ing to DIN VDE 1000-10 or BGV A3 accident prevention
regulations or an internationally comparable standard)
who is responsible for observing the applicable stand-
ards and regulations.
Work that could aect the electrical power system of
the relevant energy supply company at the site of the
solar power feed-in may only be carried out by qualified
electricians expressly authorised (licensed) by the energy
supply company. This includes changes to the facto-
ry-preset parameters. The installer must always observe
the regulations of the energy supply company.
Factory settings may only be changed by qualified elec-
trical installers or persons with at least comparable or
higher technical qualifications, e.g. foremen, technicians
or engineers. When doing so, all requirements are to be
observed.
IMPORTANT
INFORMATION
The KOSTAL Smart Energy Meter
may only be installed, maintained
and repaired by a trained and quali-
fied electrician.
The electrician is responsible for
ensuring that the applicable stand-
ards and regulations are observed
and implemented. Work that could
aect the electrical power system
of the relevant energy supply com-
pany at the site of the solar power
feed-in may only be carried out
by qualified electricians expressly
authorised (licensed) by the energy
supply company.
This includes changes to the facto-
ry-preset parameters.
1
2
3
4
5
1

9
© 2020 KOSTAL Solar Electric GmbH
General information
Open Source licence
This product contains Open Source software, developed
by third parties and licensed using vehicles including
GPL and/or LGPL.
For more details of this, a list of the Open Source soft-
ware used and the related licence texts, Ch. 4.5 go to
the Licences section on the website (Webserver) of the
KOSTAL Smart Energy Meter.
1
2
3
4
5
1

10
© 2020 KOSTAL Solar Electric GmbH
General information
1.2 EU declarations of conformity
KOSTAL Solar Electric GmbH hereby declares that the KOSTAL Smart Energy Meter described in this
document complies with the basic requirements and other relevant conditions of the directives listed
below.
n Directive 2014/30/EU
(on the approximation of the laws of the Member States relating to electromagnetic compatibility
(EMC))
n Directive 2014/35/EU
(on the harmonisation of the laws of the Member States relating to the making available on the
market of electrical equipment designed for use within certain voltage limits – in short: Low Voltage
Directive)
n Directive 2011/65/EU (RoHS)
on the restriction of the use of certain hazardous substances in electrical and electronic equipment
You will find a detailed EU Declaration of Conformity in the download area at:
www.kostal-solar-electric.com > Download > Accessories > KOSTAL Smart Energy Meter > Country >
Certificates
1
2
3
4
5
1

11
© 2020 KOSTAL Solar Electric GmbH
General information
1.3 About this manual
Read this manual carefully in its entirety.
It contains important information on the installation
and operation of the KOSTAL Smart Energy Meter. Pay
particular attention to the instructions regarding safe
usage. KOSTAL Solar Electric GmbH assumes no liability
for damages arising from the non-observance of this
manual.
This manual is an integral part of the product. It applies
exclusively to the KOSTAL Smart Energy Meter from
KOSTAL Solar Electric GmbH. Keep this manual and
give it to the new owner should you pass the meter on to
a new operator.
The installer and the operator must have unrestricted
access to these instructions at all times. The installer
must be familiar with this manual and follow all
instructions.
The most recent version of the manual for your product
is available in the download area at www.kostal-so-
lar-electric.com.
Target group
This manual is intended for trained and qualified electrical
technicians who install, maintain and repair the KOSTAL
Smart Energy Meter.
Information concerning your safety or that of the unit is
specifically highlighted.
1
2
3
4
5
1

12
© 2020 KOSTAL Solar Electric GmbH
General information
Navigation through the document
In order to enable navigation through this document, it
contains clickable areas.
One of these is the navigation bar in the header of each
page. By clicking here, you are taken to the overview
pages of the individual chapters.
The table of contents can also be used in this way: From
the index at the beginning of each chapter you can go to
the indicated sub-chapter in one click.
Fig. 1: Navigation through the document
1 Calling up the main table of contents
2 Navigation bar
3 Tables of contents
You can navigate to the referenced points in the
document within the instruction text using the
cross-references.
Ch. 1
Fig. 1, It. 2
Fig. 2: Examples of cross-references
1
2
3
4
5
1

13
© 2020 KOSTAL Solar Electric GmbH
General information
1.4 Notes in this manual
Installation
Install a line circuit breaker into the mains cable
between the inverter and the feed meter to
secure it against overcurrent.
In countries in which a second PE connection
is prescribed, connect this at the marked place
on the housing.
Connecting AC-side
Connect the wires of the mains cable to the
AC terminal in accordance with the labelling.
For connection with a computer or with a
computer network. Connect several inverters
to a network for data retrieval.
DANGER
De-energise the device,
secure it against being
restarted and wait five
minutes so that the capaci-
tors can discharge.
Risk of death due to electrical
shock and discharge!
IMPORTANT NOTE
To connect the AC cables,
the inverter is equipped with
spring-loaded terminal strips.
INFO
For connection with a
computer, an Ethernet cable
of category 6 is to be used.
Fig. 3: Safety instructions in this manual
1 Note icon within the instruction text
2 Warning
3 Information note
4 Other notes
Notes have been incorporated into the instruction text. A
dierentiation is made in this manual between warnings
and information notes. All notes are identified in the text
line by an icon.
1
2
3
4
5
1

14
© 2020 KOSTAL Solar Electric GmbH
General information
Warnings
The warnings refer to life-threatening dangers. Serious
injuries possibly resulting in death may occur.
Each warning consists of the following elements:
DANGER
De-energise the device, secure it
against being restarted and wait five
minutes so that the capacitors can
discharge.
Risk of death due to electrical shock
and discharge!
Fig. 4: Structure of the warnings
1 Warning symbol
2 Signal word
3 Type of danger
4 Corrective actions
Warning symbols
Danger
Danger due to electrical shock and discharge
1
2
3
4
5
1

15
© 2020 KOSTAL Solar Electric GmbH
General information
Signal words
Signal words are used to identify the severity of the
danger.
DANGER
Indicates a direct hazard with a high level of risk, which,
when it is not avoided, may result in death or serious
injury.
WARNING
Indicates a hazard with a moderate level of risk, which,
when it is not avoided, may result in death or serious
injury.
CAUTION
Indicates a hazard with a low level of risk, which, when
it is not avoided, may result in minor or slight injury or
property damage.
Information notes
Information notes contain important instructions for the
installation and problem-free operation of the energy
meter. These must be followed at all times. The informa-
tion notes also point out that failure to observe instruc-
tions may result in damage to property or financial loss.
IMPORTANT
INFORMATION
The energy meter may only be
installed, operated, maintained and
repaired by trained and qualified
sta.
Fig. 5: Example of an information note
1
2
3
4
5
1

16
© 2020 KOSTAL Solar Electric GmbH
General information
Symbols within the information notes
Important information
Damage to property possible
Other notes
They contain additional information or tips.
INFO
This is additional information.
Fig. 6: Example of an information note
Symbols within the additional notes
Information or tip
Enlarged view
1
2
3
4
5
1

17
© 2020 KOSTAL Solar Electric GmbH
General information
1.5 Symbols used
Symbol Meaning
1., 2., 3. ... Sequential steps in a handling instruction
PEect of a handling instruction
HFinal result of a handling instruction
ÆCross-reference to other places in the document or
to other documents
nList
Tab. 1: Symbols and icons used
Abbreviations used
Abbrevia-
tion Explanation
Tab. Table
Fig. Figure
It. Item
Ch. Chapter
1
2
3
4
5
1

18
© 2020 KOSTAL Solar Electric GmbH
General information
1.6 Labels on the energy meter
Signs and labels are attached to the housing of the
energy meter. These signs and labels may not be altered
or removed.
Symbol Explanation
Electrical installations require specialist skills
Housing with protective insulation (protective class II).
Device may not be disposed of with household waste.
Observe the local application of disposal requirements
CE marking
The product satisfies the applicable EU requirements
1
2
3
4
5
1

19
2.
Navibutton Verlinkung Kapitel 02
11 / 2020 © 2020 KOSTAL Solar Electric GmbH
2. Device and system description
2.1 Using the KOSTAL Smart Energy Meter .................................................................................... 20
2.2 The KOSTAL Smart Energy Meter ............................................................................................. 21
2.3 LED statuses ............................................................................................................................ 22
2.4 Functions .................................................................................................................................. 23
22
3
4
5
1

20
11 / 2020 © 2020 KOSTAL Solar Electric GmbH
Device and system description
2.1 Using the KOSTAL Smart Energy Meter
The KOSTAL Smart Energy Meter (KSEM) is a measuring
device, which determines electrical measuring values
at the grid connection point and is available via LAN
or RS485. It can be used in combination with various
KOSTAL solar inverters and batteries.
This includes the following inverters:
n PLENTICORE plus
n PLENTICORE BI
n PIKO IQ
n PIKO MP plus
n PIKO 4.2-20
n PIKO CI
n PIKO EPC
These can be used in combination with the KOSTAL
Smart Energy Meter for the following applications:
n Reading the current home consumption and output
power
n Power curtailment of inverters down to 0W
n If several PV systems in the same home network
share a multiple-inverter connection, only one
KOSTAL Smart Energy Meter is required at the grid
connection point
n If using PIKO MP plus with a battery, the battery
management, which controls the battery’s charging/
discharging, is taken over by the KOSTAL Smart
Energy Meter,
n sending consumption data to the KOSTAL Solar
Portal
22
3
4
5
1
Other manuals for Smart Energy Meter
2
Table of contents
Other Kostal Measuring Instrument manuals