code R28009.100en www.kseniasecurity.com
ed.04/2020
Note: temperatures below +5 °C can cause the unum to report a false low battery indication. Operation
below +5 °C will reduce the battery life significantly.
Caution! Observe the correct polarity when installing battery. Use only Panasonic Lithium CR-123A
batteries for replacement. Risk of explosion if the battery is replaced by an incorrect type.
Warning! Battery may explode if mistreated. Do not recharge, disassemble or dispose of in fire. Dispose of
used batteries according to the instructions.
ENROLLING
• Activate the Enroll mode from the lares 4.0 control panel.
• Remove the battery-contact insulator.
• Close the front cover.
• For more details about software settings, please refer to the lares 4.0 Programming Manual.
TECHNICAL DATA
• IR Sensor: Dual Element Digi Pyro
• Power: 1 CR123A Lithium battery included for a maximum battery life up to 4 years
• RF immunity: 20 V/m, 10-1000 MHz; 10 V/m, 1-2 GHz
• White Light Immunity: 6500 lux
• Sensitivity: adjustable at 2 or 3 impulses
• Coverage: adjustable from software or Keypad at 6 or 12 m. range
• Operational Frequency: 868 MHz
• Open Air Range: up to 400 m
• Operative Temperature Range: from +5 °C to +40 °C
• Materials: Base: ABS; Front: HDPE
• Dimensions:113 x 60 x 45 mm (h x w x d)
• Weight: 104 g
QUANTITY DATA
Technical data, appearance, functionality and other product characteristics may change without notice.
CERTIFICATIONS
CERTIFICATIONS
Europe - RoHS, CE
EN50131 Grade 2 - Class II
T031:2014
SSF 1014 Larmklass R
lares 4.0 models wls 96 16 40 40 wls 140 wls 644 wls
Maximum number of unum wls
sensors
32 16 40 40 64 64