KTS-Electronic GPA 500 XS User manual

GPA 500 XS
Model 2020
Ground
Penetrating
Analyzer
KTS-Electronic GmbH & Co. KG
Germany

KTS-Electronic GmbH & Co. KG –GPA 500 XS
Table of content
1General guidelines............................................................................................. 3
1.1 Preface .......................................................................................................... 3
1.2 Important details............................................................................................ 3
1.3 Scope of delivery ........................................................................................... 4
2Hardware operation ........................................................................................... 5
2.1 Assembly of GPA probes: ............................................................................. 5
2.1.1 GPA 500 XS probe ................................................................................. 5
2.2 Assembly of GOLD ID-XL search coils.......................................................... 7
2.2.1 Search coil 30x30cm............................................................................... 7
2.2.2 Search frame 1x1m................................................................................. 8
3Electronic unit .................................................................................................... 9
3.1 Setup electronic unit ...................................................................................... 9
3.2 GOLD ID-XL display .................................................................................... 10
3.3GPA display................................................................................................. 10
4Search methods ............................................................................................... 11
4.1 GPA search methods .................................................................................. 11
4.1.1 Search with the universal probe............................................................ 11
4.2 GOLD ID-XL search methods...................................................................... 11
4.2.1 Search with 30x30cm search coil.......................................................... 12
4.2.2 Search with 1x1m search frame............................................................ 13
4.3 Battery and charger ..................................................................................... 14
5Android software.............................................................................................. 15
5.1 Commissioning of tablet computer .............................................................. 15
5.2 Bluetooth-Connection .................................................................................. 16
5.3 KTS GPA 3D - Software .............................................................................. 17
5.3.1 Search with KTS GPA 3D ..................................................................... 17
5.3.2 Evaluation with KTS GPA 3D................................................................ 18
5.3.3 Settings for KTS GPA 3D...................................................................... 20
5.4 KTS GPA Visualizer -software..................................................................... 21
5.4.1 Search with KTS GPA Visualizer .......................................................... 21
5.4.2 Evaluation with KTS GPA Visualizer..................................................... 22
5.4.3 Settings for KTS GPA Visualizer........................................................... 23
5.5 Reinstallation............................................................................................... 24
6System requirements and license agreements ............................................. 24
6.1 System requirements................................................................................... 24
6.2 License agreements .................................................................................... 24
6.3 Terms of use................................................................................................ 25
6.4 Exclusion of liability ..................................................................................... 25
7Warranty ........................................................................................................... 25
7.1 After expiration date .................................................................................... 26
7.2 Care............................................................................................................. 26
7.3 Legal note.................................................................................................... 26
8Contact.............................................................................................................. 27

KTS-Electronic GmbH & Co. KG –GPA 500 XS
3
1 General guidelines
1.1 Preface
Congratulations on your purchase of one of the most advanced high performance
detectors: The GPA 500 XS.
The GPA 500 XS is the new development of KTS-Electronic GmbH & Co. KG. The
device contains the GPA 500 XS unit and the GOLD ID-XL unit.
Besides the KTS 3D software, the new "GPA Visualizer" software is pre-installed on
the tablet computer; this enables an easy operation without the need for previous
knowledge.
Already pre-installed programs and an instruction manual which is furnished with
numerous illustrations and easy to understand will facilitate the assembly, so that
nothing will stand in the way for a practical application.
This instruction has been developed by KTS-Electronic GmbH & Co. KG. Any
alterations or duplications are only allowed with written permission of KTS-
Electronic GmbH & Co. KG. KTS-Electronic GmbH & Co. KG reserves the right to
modify the instruction with new knowledge at anytime. The new instructions can
always be downloaded gratuitously from our website.
1.2 Important details
Please note:
Stay away from conducting overhead lines
Do not use cell phone during operation
Do not process measurements during thunderstorms
Keep dry
Accurate operation is only guaranteed with a fully charged battery
For operation or charging only use the components enclosed or authorized by
KTS GmbH & Co. KG.

KTS-Electronic GmbH & Co. KG –GPA 500 XS
4
1.3 Scope of delivery
Hardware:
GPA 500 XS electronic unit with integrated GOLD ID-XL metal discrimination
and Bluetooth
GPA 500 XS probe 50 cm (20") incl. bag
GOLD ID-XL 30x30cm search coil with carbon telescope rod
Eight-fold demountable GOLD ID-XL search frame 1x1 meter incl. bag
Separate Battery pack
Tablet computer with KTS-Software, Li-ion battery and bag
Powerful 220 Volt quick charger with 110 Volt adapter
150 W transformer to charge in car
Solid hard top case
Software:
Newly developed KTS-3D Software and KTS GPA Visualizer software (both
pre-installed on tablet computer)
USB stick with software for processing data on other computers
Service:
English, German, French or Spanish user's manual.
2 years manufacturer's warranty for the entire scope of delivery (incl. hardware
and software.

KTS-Electronic GmbH & Co. KG –GPA 500 XS
5
2 Hardware operation
2.1 Assembly of GPA probes:
GPA search method requires a probe.
2.1.1 GPA 500 XS probe
Connect the telescope rod to the probe as shown and fasten the screw with
the included Allen key.
Join the electronic unit to the other side of the telescope rod as shown
Plug the probe in to the “GPA”-socket of the electronic unit.
Fig.: 1 - GPA 500 XS Universal probe with carbon telescope rod and electronic unit
Fig.: 2 - Assembly probe
Fig.: 3 - Assembly electronic unit

KTS-Electronic GmbH & Co. KG –GPA 500 XS
6
Fig.: 4 - Universal probe with tablet computer

KTS-Electronic GmbH & Co. KG –GPA 500 XS
7
2.2 Assembly of GOLD ID-XL search coils
GOLD ID-XL search method requires a search coil.
2.2.1 Search coil 30x30cm
The search coil is already connected to the telescope rod.
Screw the telescope rod to armrest.
Connect the electronic unit to the armrest (display facing up) and fasten it with
the adjusting screw.
Plug the search coil in to the “Pulse”-socket of the electronic unit.
Fig.: 5 - 30x30cm search coil with armrest

KTS-Electronic GmbH & Co. KG –GPA 500 XS
8
2.2.2 Search frame 1x1m
Plug the pipes together. Mind the colored markings, which should all face in
the same direction.
While plugging together the last two pieces there will be a 10-15cm slack of
cable which runs through the pipe. Fold the cable and place it into the pipe like
shown in the figures.
Plug the search frame in to the “Pulse”-socket of the electronic unit.
Fig.: 6 - Folded cable
Fig.: 7 - Placed cable
Fig.: 8 - Search frame (unpluggged)

KTS-Electronic GmbH & Co. KG –GPA 500 XS
9
3 Electronic unit
The newly developed compact housing of the GPA 500 XS now contains the
electronic unit of the GPA as well as the GOLD ID-XL and impresses with it simple
handling.
The GPA 500 XS is a measuring device, which can measure alterations of ground
anomalies caused by metal objects, soil structure or excavations and can
discriminate from normal ground magnetism. Correct results strongly depend on
ground type and measuring method. Areas to be measured should not have electric
fields (like high voltage cables or earth wires) or strong mineralised or wet grounds
because they influence the measurement. The dryer the soil, the more precise the
results.
Fig.: 9 - Elektronic unit
3.1 Setup electronic unit
After switching the unit on via On-/Off-button the language selecting screen
will appear.
After selecting your language the option to select a search method will appear.
Fig.: 10 - Language selection
Fig.: 11 - Search method selection

KTS-Electronic GmbH & Co. KG –GPA 500 XS
10
3.2 GOLD ID-XL display
The Goldscan display has three different indications for the detectable metals
which will be displayed with different colors and ID-number on the screen.
Frequency and volume of the signal sound are variable.
The “Reset”-button is for an automatic zero balance.
The “back”-button leads you back to the search method selecting screen.
The battery status will be shown in the lower left corner of the display.
If you tick the “auto”-box a reset will be performed automatically after each
detection.
Fig.: 12 - GOLD ID-XL display
3.3 GPA display
The sensor value will be shown as a bar graph. The corresponding digits will
appear on the right hand side of the screen.
The calibration value will be shown on the left hand side of the screen.
The “back”-button leads you back to the search method selecting screen.
The battery status will be shown in the lower left corner of the display.
Fig.: 13 - GPA display

KTS-Electronic GmbH & Co. KG –GPA 500 XS
11
4 Search methods
4.1 GPA search methods
There must be a probe connected to the electronic unit to use the GPA search
method.
4.1.1 Search with the universal probe
Switching the electronic unit on via On-/Off-button.
Select your language.
Select “GPA System” as search method.
The electronic unit should face up while using the probe
Optionally the tablet computer can be connected to the electronic unit via
Bluetooth. (See 5.2)
Place the universal probe so that one of the square ends shows in the
direction you want to search and check both, calibration value and sensor
value..
Turn the probe 180° so that the opposite square now face forward and check
the two values again.
Choose the side with values closer to 2,5 as forward direction (as shown in the
following figures).
The distance between the probe and ground should not vary a lot.
Avoid hectic movements and try to walk in straight lines.
Fig.: 14 - Universal probe
Fig.: 15 - Complete universal probe
4.2 GOLD ID-XL search methods
There must be a coil connected to the electronic unit to use the GOLD ID-XL search
method.

KTS-Electronic GmbH & Co. KG –GPA 500 XS
12
4.2.1 Search with 30x30cm search coil
Switching the electronic unit on via On-/Off-button.
Select your language.
Select “GOLD ID-XL” as search method.
Hold the search coil to the ground and press the Reset-button for a brief
moment. You herewith attain a zero balance, which is necessary for a trouble-
free search.
During zero balance make sure that there are no metallic objects near the
search coil. This could cause a wrong adjustment of the metal detector and
produce unwanted indicator effects.
Repeat the zero balance process after soil-changes like a dig up or after you
changed location.
In the beginning please set the frequency to the lowest level. The volume
should be set hearable with the help of the Audio control. Generally we
recommend to start with the lowest frequency adjustment to acquaint yourself
with the handling of the device. With advancing experience it is expedient, to
increase the frequency gradually, what will have a positive effect on the search
performance.
It is recommendable to keep the search coil parallel to the ground while
searching.
It takes some experience to interpret the sounds correctly. The sound
becomes more intense the bigger the object or the closer to the surface the
object is.
Fig.: 16 - Complete 30x30cm search coil

KTS-Electronic GmbH & Co. KG –GPA 500 XS
13
4.2.2 Search with 1x1m search frame
Switching on the electronic unit via On-/Off-button.
Select your language.
Select “GOLD ID-XL” as search method.
Perform a zero balance like in 4.2.1
Frame can be carried by either one or two persons.
The search frame is primarily used for the deep sounding after medium sized
and large metal objects. The frame is indispensable for the search in larger
areas.
It is recommendable to keep the search coil parallel and close to the ground
while searching.
Small scrap iron parts will automatically be filtered.
Set frequency like in 4.2.1.
Fig.: 17 - Complete search frame

KTS-Electronic GmbH & Co. KG –GPA 500 XS
14
4.3 Battery and charger
The electronic unit is powered by two external
2900mAh Li-Ion batteries, which gets fully
charged each within 90 minutes. (Please note: Do
not exceed the charging time of 90 minutes). The
operating time of the unit depends on the type and
size of the search coil and type of headphones. It
varies between 4 to 6 hours. The charging process
is indicated by a red glowing LED on the power
adapter. The LED changes to green when the
battery is fully charged. Disconnect the adapter
after charging is finished.
An included inverter allows for charging in the car.
Fig.: 18 - Power adapter for electronic unit
Fig.: 19 - Power Inverter
Fig.: 20 - Batterypack incl. wire and clip
The external battery pack is connected to the electronic unit via included
cable. The battery pack can be attached to your belt loop or somewhere
similar.

KTS-Electronic GmbH & Co. KG –GPA 500 XS
15
5 Android software
There is a tablet computer included in the GPA 500 XS-set for two-dimensional and
three-dimensional evaluation of your measurements which connects wirelessly via
Bluetooth with the electronic unit.
Fig.: 21 - Tablet computer incl. mount
5.1 Commissioning of tablet computer
Turn on the tablet computer by pressing and holding the left button on the
upper edge.
Unlock the display by swiping across the screen.
Both preinstalled programs are located right on the desktop. Simply start them
by tapping.
The menu of each program is on the right hand side of the screen.
Each program-window has an “info”-button on the lower right hand corner of
the screen which provides you with some information about the current
window.
You can leave the prgram by tapping on the “QUIT”-button which is located
next to the “info”-button.
There is a “share”-button in the upper right hand corner of the screen. Tap it to
take a screenshot which can be shared on several platforms.
The tablet computer can be connected to the telescope rod of the universal
probe. To this end there is a mount on the telescope rod, to which the tablet
computer connects and is secured with a half turn. (see following figure)

KTS-Electronic GmbH & Co. KG –GPA 500 XS
16
Fig.: 22 - Assembly tablet with telescope rod and mount
5.2 Bluetooth-Connection
To evaluate the measurements of the GPA universal probe on the tablet you need to
connect the electronic unit to the tablet via Bluetooth.
To pair the electronic unit with the tablet computer you need to switch on the
unit and select the universal probe of the “GPA”- search method.
Turn on the tablet and run the program of your choice.
Select “CONNECT” from the menu on the right hand side of the screen.
Select the shown device.
Note: If there is no device shown tap on the button “SCAN FOR BLUETOOTH
DEVICES” (several times if necessary) and select it.
A confirmation pop up with :”CONNECTED” will appear on the tablet computer.
A blue dot will appear on the screen of the electronic unit.
Fig.: 23 - Successful Bluetooth connection

KTS-Electronic GmbH & Co. KG –GPA 500 XS
17
5.3 KTS GPA 3D - Software
5.3.1 Search with KTS GPA 3D
Fig.: 24 - Walking direction for 3D evaluation
Before starting the measurement the area should be divided in equal lanes
Select “MEASURE” in the menu on the right hand side of the screen.
Tap on the “START”-button which will appear on the lower part of the screen
and immediately start walking with the universal probe like shown in the figure
above.
During the measuring process the values will appear in different colors on the
screen.
After each lane the measurement will stop automatically. Tap on “START” to
continue. (The number of lanes is selectable. See 5.3.3).
The frequency of the measurements is adjustable. The options “SLOW”,
“NORMAL” and “FAST” appear on the lower hand of the screen.(Selecting
“SLOW” results in a bigger area but lower resolution and vice versa).
For higher accuracy you should walk in a steady pace.
Lane lengths of 5 to 10m are advantageous.
You can pause a measurement anytime with the “STOP”-button. (Continue
with the “START”- button.).
After the measurement is completed the image gets rendered.
The measurement can be saved with the “SAVE”-button. Time and date will be
added automatically after you named the image.
The measurement can be deleted with the “RESET”- button.
Hint: The Bluetooth pairing has failed if there is no “START”- button on the lower part
of the screen . (see 5.2)

KTS-Electronic GmbH & Co. KG –GPA 500 XS
18
Fig.: 25 - Active measurement with KTS GPA 3D
5.3.2 Evaluation with KTS GPA 3D
You can switch to the three dimensional view any time by tapping “3D” in the
menu (even while still measuring).
Here you see the current measurement in 3D.
Tap “LOAD” for loading a previously saved measurement.
The 3D- image can be moved with one finger and rotated/zoomed with two
finger (see following figures).
Fig.: 26 - 3D evaluation of measurements

KTS-Electronic GmbH & Co. KG –GPA 500 XS
19
Fig.: 27 - Two-finger touchscreen gesture
Tap “VIEW” to see measurements in 2D.
Tapping “CURRENT MEASUREMENT” on the lower part of the screen will
show the current measurement in 2D.
Tapping “LOAD” gives you the option to see a previously saved measurement
in 2D.
Fig.: 28 - 2D evaluation of measurements

KTS-Electronic GmbH & Co. KG –GPA 500 XS
20
You can manage your saved measurements by tapping on “FILES”
Tap on a file to display the options : “open file”, “rename file”, “delete file” and
“show file in 3D”.
To delete all files tap the button “DELETE ALL FILES” on the lower left part of
the screen.
Fig.: 29 - File management
5.3.3 Settings for KTS GPA 3D
The following settings can be adjusted by tapping on “SETTINGS”:
o“Number of lanes”: Changes the number of lanes.
o“Number of measurements”: Number of measurements in one lane.
o“Language”: Selection between German, English and French. (Note:
App will restart after selecting a language).
o“Reset Settings”: Resets the device to factory settings.
o“Developer Settings”: Please do not change the developer settings
except for “Measure-delay”. Here you can change the time between two
measurements. Please note that this option will effect the speed options
“SLOW”, “NORMAL” and “FAST” under “MEASURE”.
This manual suits for next models
1
Table of contents
Other KTS-Electronic Measuring Instrument manuals
Popular Measuring Instrument manuals by other brands

MipFly
MipFly MipBip user manual

Dentech
Dentech AYRDYNE Installation, operation and maintenance manual

Anton Paar
Anton Paar DMA 4100 M instruction manual

Underground Magnetics
Underground Magnetics MAG Series user manual

Universal Flow Monitors
Universal Flow Monitors FlowStream FD Series user manual

Bushnell
Bushnell Tour Z6 user manual

Bartington
Bartington MS2 Operation manual

netAlly
netAlly ETHERSCOPE nXG quick start guide

Delmhorst
Delmhorst TechCheck PLUS owner's manual

Burkert
Burkert 8035 instruction manual

Magnetrol
Magnetrol E3 Modulevel series Safety manual

PCB Piezotronics
PCB Piezotronics IMI SENSORS 602D11/030AC Installation and operating manual