Kuhnke PG 674 User manual

Kuhnke Electronics
Instruction Manual
E 390 GB
PG 674
Operating Terminal for KUAX 674 / 673
4 April 1996 / 65.135

Thismanualisprimarilyintendedfortheuseofthedesigningengineer,the
projectplanningengineer,andthedevelopingengineer.Itdoesnotgiveany
informationaboutdeliverypossibilities.Dataisonlygiventodescribethe
productandmust not be regarded asguaranteedproperties in the legal sense.
Any claims for damages against us – on whatever legal grounds – are excluded
exceptin instancesofdeliberateintent orgrossnegligenceonourpart.
Wereservetherightsforerrors,omissionsormodifications.
Reproductionevenofextractsonlywiththeeditor'sexpressandwrittenprior
consent.

Contents - 1
Table of contents
Table of contents
1. Introduction................................................................ 1-1
2. Reliability, Security...................................................... 2-1
2.1. Target group ............................................................................ 2-1
2.2. Reliability ................................................................................ 2-1
2.3. Notes...................................................................................... 2-2
2.3.1. Danger................................................................................. 2-2
2.3.2. Dangers caused by high contact voltage .................................. 2-2
2.3.3 Important information / cross reference..................................... 2-2
2.4. Security ................................................................................... 2-3
2.4.1. To be observed during project planning and installation............. 2-3
2.4.2. To be observed during maintenance and servicing .................... 2-4
2.4.3. Measures for the prevention of electrostatic charge.................... 2-4
3. Design of the PG 674.................................................. 3-1
3.1. Display and operating elements.................................................. 3-1
3.2. Hand-held terminal PG 674 (674.001.00) .................................. 3-2
3.3. Built-in terminal PG 674 (674.010.00) ....................................... 3-3
3.3.1. Design and Dimensions .......................................................... 3-3
3.3.2. Installation ............................................................................ 3-4
3.3.2.1. Front panel cutout............................................................... 3-4
3.3.2.2. Inserting the built-in terminal................................................. 3-4
3.4. Technical specifications ............................................................. 3-5

Contents - 2
Table of contents
4. The PG 674 as a programming device .......................... 4-1
4.1. General information on the operating terminal ............................. 4-2
4.2. Front view................................................................................ 4-3
4.3. Key pad .................................................................................. 4-4
4.3.1. Function keys ........................................................................ 4-4
4.4. Operating modes of the operating terminal PG 674 ..................... 4-6
4.4.1. Restricted operating mode ...................................................... 4-6
4.5. Display window of the operating terminal PG 674 ....................... 4-7
4.5.1. Standard display ................................................................... 4-7
4.6. Commands of the operating terminal PG 674 .............................. 4-8
4.6.1. Activating the open mode (entering the key code)...................... 4-8
4.6.2. Exiting the open operating mode ............................................. 4-8
4.6.3. Displaying the key code ......................................................... 4-9
4.6.4. Changing the key code .......................................................... 4-9
4.6.5. System information .............................................................. 4-10
4.6.6. Displaying status and error messages..................................... 4-10
4.6.7. Choosing a program............................................................ 4-11
4.6.7.1. Giving access to the choice of program function .................. 4-11
4.6.7.2. Changing the program number ......................................... 4-13
4.6.8. Initializing the cam control unit.............................................. 4-14
4.6.9. Choosing an output ............................................................. 4-15
4.6.10 Programming cams ............................................................. 4-16
4.6.11. Optimizing cams ............................................................... 4-18
4.6.12. Displaying cams ................................................................ 4-19
4.6.13. Deleting cams ................................................................... 4-20
4.6.14. Deleting outputs................................................................. 4-21
4.6.15. Deleting programs ............................................................. 4-21
4.6.16. Copying programs............................................................. 4-22
4.6.17. Program transfer................................................................ 4-23
4.6.18. Activating the dynamic mode of outputs ............................... 4-24
4.6.19. Deadtime compensation ..................................................... 4-25
4.6.20. Time cams ........................................................................ 4-26
4.6.21. Encoder speed reduction – electronic gearing ....................... 4-27
4.6.22. Choice of language ........................................................... 4-28

Contents - 3
Table of contents
4.6.23. Setting the display contrast (as from version 2.0) ................... 4-29
4.6.24. Self-test of the operating terminal (as from version 2.0) .......... 4-30
4.6.25. Self-test of the operating terminal (versions < 2.0).................. 4-32
Index....................................................................... Index-1
Sales & Service

Contents - 4
Table of contents

1 - 1
Introduction
1. Introduction
The PG 674 is a small, handy device with a keyboard and two-
line display. It is used for operating the electronic cam control
units Posi Control KUAX 674 and KUAX 673. It is separated
from the cam control unit to allow variable use. It can be con-
nected with the cam control unit via the programming interface
at any time, even when the machine is running. This makes it
easy to check or modify the programs at the machine.
Choice of prog
Choice of output
Outputs off
Delete
Outputs on
Gear
Time cam
Show errors
Set cam
Choice of cam

1 - 2
Introduction
The PG 674 is available in two designs:
Hand-held terminal
As a portable hand-held terminal it can easily be transported
and connected to the control device. The integrated buffered
memory allows you to load programs from one controller and
transfer them to another controller.
Built-in terminalAs a built-in terminal the device is firmly built into i.e. the
door of the switching cabinet and is thus permanently available
as an operating and display device.
The present operating manual exclusively describes the hard-
ware of the PG 674 and how you use it to operate controllers.
The control devices themselves are described elsewhere:
Controller Instruction manual
KUAX 674 E 375 GB
KUAX 673 E 293 GB
.

2 - 1
Reliability/Security
2. Reliability, Security
2.1. Target group
This instruction manual contains all information necessary for
the use of the described product (control device, software, etc.)
according to instructions. It is written for the personnel of thepersonnel of the
personnel of thepersonnel of the
personnel of the
construction, project planning, service and commissioningconstruction, project planning, service and commissioning
construction, project planning, service and commissioningconstruction, project planning, service and commissioning
construction, project planning, service and commissioning
departmentsdepartments
departmentsdepartments
departments. For proper understanding and error-free applica-
tion of technical descriptions, instructions for use and particu-
larly of notes of danger and warning, extensive knowledge ofextensive knowledge of
extensive knowledge ofextensive knowledge of
extensive knowledge of
automation technologyautomation technology
automation technologyautomation technology
automation technology is compulsory.
2.2. Reliability
Reliability of Kuhnke controllers is brought to the highest pos-
sible standards by extensive and cost-effective means in their
design and manufacture.
Amongst which are:
· selecting high-quality components,
· quality arrangements with our sub-suppliers,
· measures for the prevention of static charge during the hand-
ling of MOS circuits,
· Worst-Case dimensioning of all circuits,
· inspections during various stages of fabrication,
· computer aided tests of all assembly groups and their
coefficiency in the circuit,
· stress-test in raised ambient temperatures during 72 hours
realtime with nominal load on the outputs,
· statistic assessment of the quality of fabrication and of all re-
turned goods for immediate taking of adjustment measures.
Despite these measures, the occurrence of errors in electronic
control units - even if most highly improbable - must be taken
into consideration.
Text muß n

2 - 2
Reliability/Security
2.3. Notes
Please pay particular attention to the additional notes which we
have marked by symbols in this instruction manual:
2.3.1. Danger
This symbol warns you of dangers which may cause
death, (grievous) bodily harm or material damage if the
described precautions are not taken.
2.3.2. Dangers caused by high contact voltage
This symbol warns you of dangers of death or (grievous)
bodily harm which may be caused by high contact
voltage if the described precautions are not taken.
2.3.3 Important information / cross reference
This symbol draws your attention to important additional
information concerning the use of the described product.
It may also indicate a cross reference to information to be
found elsewhere.

2 - 3
Reliability/Security
2.4. Security
Our product normally becomes part of larger systems or install-
ations. The following notes are intended to help integrating the
product into its environment without dangers for man or mate-
rial/equipment.
2.4.1. To be observed during project planning and installation
- 24V DC power supply:
· provide sufficient separation of low voltage,
· apply power packs in accordance with IEC 364-4-41 or
CENELEC HD 384.4.41 (VDE 0100, Part 410) respectively.
- In case of power breakdowns or power fades: the program has
to be structured in such a way as to create a defined state at
restart that excludes dangerous states.
- Emergency switches or other emergency installations have to
be realized in accordance with EN 60204/IEC 204
(VDE 0113). They have to be effective at any time.
- Safety and precautions regulations for qualified applications
have to be observed.
- Please pay particular attention to the notes of warning (→
2.3. Notes) which, at relevant places, will make you aware of
possible sources of errors.
- The relevent standards and VDE regulations are to be ob-
served in every case.
- Control elements have to be installed in such a way as to ex-
clude unintended operation.
- Control cables have to be layed in such a way as to exclude
interference (inductive or capacitive) which could influence
the operation of the controller.
Toachieveahighdegreeofconceptualsafetyinplanning
and installing an electronic controller it is essential to
follow the instructions given in the manual exactly be-
cause wrong handling could lead to rendering measures
against dangerous failures ineffective or to creating
additional dangers.

2 - 4
Reliability/Security
2.4.2. To be observed during maintenance and servicing
- During measuring and checking operations on a controller in
a power-up condition, precaution regulation VBG 4.0 has to
be observed and §8 (Admissible deviations during working on
parts) in particular.
- Repairs must only be executed by the trained Kuhnke person-
nel (usually in the main factory in Malente). Warranty ex-
pires in any other case.
- Spare parts:
Only use parts approved of by Kuhnke. Only genuine Kuhnke
modules must be used in modular controllers.
- Modules must only be connected to or disconnected from the
controller with no voltage supplied. Otherwise they may be
destroyed or (possibly not immediately recognizably!) de-
tracted from their proper functioning.
- Always deposit batteries and accumulators as special waste.
2.4.3. Measures for the prevention of electrostatic charge
Electrostatic charge is dangerous for components and assembly
groups. It is a peculiarity of electrostatics to not destroy the sen-
sitive components but to damage them in a not immediately
conceivable way. It is because of this that devices stop function-
ing after some time of service.
The ESD measures (ESD = electrostatic discharge) executed in
the factory are only guaranteed to be effective if they are also
regarded by the user (service).
Please note: - Only store parts in their factory-packing or in an antistatic
packing of similar quality.
- Assembly groups must only be touched by persons who are
grounded via a wrist bracelet and/or a discharging mat and
shoe-grounding strips ( observe protection of people!).
- Only ship assembly groups in their factory-packing or in an
antistatic packing of similar quality.
Reference to literature (Fa. 3M Deutschland GmbH,
Neuss): Information brochure
Interesting Facts about Electrostatics in Micro-Electronics

3 - 1
Hardware
Choice of prog
Choice of output
Outputs off
Delete
Outputs on
Gear
Time cam
Show errors
Set cam
Choice of cam
3. Design of the PG 674
The operating terminal PG 674 is used for programming the
cam control unit (see "4. The PG 674 as a programming de-
vice").
It can be supplied as a portable hand-held terminal and as a
built-in terminal.
3.1. Display and operating elements
LCD display (see ch. 4)
Short description of the function keys
Keyboard
(for function see ch. 4)

3 - 2
Operating terminal PG 674
3.2. Hand-held terminal PG 674 (674.001.00)
The hand-held terminal can be connected to and disconnected
from the cam control unit during operation.
The connecting cable is firmly attached to the hand-held termi-
nal. It serves both communication with the cam control unit and
supplying power to the hand-held terminal (24 V DC), which
are supplied by the cam control unit.
Gear
Time cam
Show errors
Set cam
Choice of cam
Choice of prog
Choice of output
Outputs off
Delete
Outputs on

3 - 3
Hardware
3.3. Built-in terminal PG 674 (674.010.00)
As a built-in terminal, the PG 674 has a connector on the rear
side for the connecting cable to the cam control unit. The 24 V
DC supply voltage is separately connected to a 2-pin screw-type
locking connector.
The built-in terminal is expected to be available as from
Version 2.0 in the spring of 1995.
3.3.1. Design and Dimensions
Side view Rear view
Connections:
Faston connec-
tor for protec-
tive ground
Screw-type
locking connec-
tor for 24 V DC
supply
Sub-D connec-
tor for connect-
ing cable to the
cam control
unit
Cable order no.: 674.150.31
+24V 0 V

3 - 4
Operating terminal PG 674
3.3.2. Installation
The PG 674 is installed in a front panel (i.e. switching cabinet
door).
To do this you must cut out an opening in the front panel:
3.3.2.1. Front panel cutout
3.3.2.2. Inserting the built-in terminal
- Remove the rear mounting brackets of the PG
674:
to do this unscrew the 4 nuts.
- Push the PG 674 from the front into the front
panel cutout.
- Screw the mounting brackets on again.

3 - 5
Hardware
3.4. Technical specifications
Design....................................................... -hand-held terminal or
-built-in terminal for front panel instal-
lation
Housing
Hand-held terminal ............................ plastic
Built-in terminal................................. aluminium
System of protection ................................ IP 65
(for built-in terminal only at the front)
Power supply
Voltage................................................ 24 V DC ± 20 %
Current consumption.......................... typ. 150 mA / max. 200 mA
Interfaces .................................................. V.24 (RS232) for connection to the
controlling unit
Display...................................................... LCD display
Lines/Characters................................. 2 lines x 16 characters
Resolution ........................................... 5 x 8 dots
Character size ..................................... ~5 mm
Keyboard .................................................. 25 keys
Program memory
Type .................................................... RAM
Size ..................................................... 1 cam program
Buffering............................................. accumulator
Ambient temperature ............................... 0...40 °C (during operation)
Order numbers
Hand-held terminal ............................ 674.001.00
Built-in terminal................................. 674.010.00
Connecting cable ................................ 674.150.31 (built-in terminal only)

3 - 6
Operating terminal PG 674

4 - 1
Programming
4. The PG 674 as a programming device
The cam control units KUAX 674 and KUAX 673 can be ran-
domly programmed. The devices are equipped with a RS 232
serial interface for connection of the programming device.
Connection of the programming device to the KUAX 674
Connecting plug
Connection of the programming device to the KUAX 673
Connecting plug
24 VDC RS 232 SSI - Encoder digital output digital input
1.0 - 1.7
0.0 - 0.7 1.8 - 1.15
0.8 - 0.15
turn
out.off
0
1
2
enc.0
prg.nr.
prg.run

4 - 2
The PG 674 as a programming device
4.1. General information on the operating terminal
The PG 674 is available both as a hand-held and built-in termi-
nal. Using the appropriate connecting cable, it is connected to
the „RS 232“ programming interface on the cam control unit.
The hand-held terminal is supplied via the cam control unit.
The built-in terminal must have a separate supply.
Both types of terminal basically take over 3 tasks:
- Programming
- Choosing a program
- Commissioning testing and monitoring machines
The display consists of 2 lines with 16 characters each. Four
pieces of information are permanently displayed in the standard
display:
- Current program number
- Encoder position
- Encoder speed
- Output number
The key pad consists of 25 keys, 7 of which have a double func-
tion. The keyboard has been labelled for international use,
partly with symbols. These symbols are also briefly described on
the terminal.
The operating terminal has its own memory which is protected
agains data loss by an accu. This memory has the program
number 32 and is suitable for copying programs from one cam
control unit to another.
-This instruction manual already describes how to handle
operating terminals with version 2.0 which are expected
to be available as from the spring of 1995.
-This instruction manual is also valid for the operating
terminals with version numbers < 2.0 although there are
marginal differences in the display and keyboard label-
ling. These are fairly obvious, however. The handling of
the device corresponds to that described in instruction
manual E 293 GB for the KUAX 673, .
-The differences result from the further development and
standardizing of the operating terminals.
Table of contents
Other Kuhnke Touch Terminal manuals