manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Kuntze
  6. •
  7. Measuring Instrument
  8. •
  9. Kuntze Krypton Neon DIS Assembly instructions

Kuntze Krypton Neon DIS Assembly instructions

Krypton Neon DIS Installation and Set Up Guide
Kuntze Instruments
3316 Leechburg Road | Lower Burrell | Pennsylvania | 15068
724-339-8510 | info@kuntzeinsturments.com | kuntzeinsturments.com
General Steps
1. Mount the system upright on the wall
2. Insert clean sensor
Insert Disinfection sensor into the Flow Cell Chamber for the
Disinfection Sensor (5) and screw on the Disinfection Cable
3. Power on system
4. Check flow
5. Calibrate sensor
6. If needed, set user specific settings –see operations manual
a. ASR
b. 4 –20 mA
c. Relay Alarms
Key
1–Neon DIS Instrument
2–Argon Stabiflow
3–FTG Temperature Cable
4- Disinfection Cable
5–Flow Cell Chamber for Disinfection Sensor
6–Water Inflow Valve
7–Water Outflow Valve
8–Water Sampling Reference Valve
9–Mounting Board
Check Your Flow
Make sure the Water Sampling Reference Valve is in the closed position.
System needs proper flow to operate. “Digital input 1 – no water” will show on display screen if
flow is not strong enough.
Flow minimum: 5 psi Flow maximum: 87 psi
Power Requirements
System comes with US power cord
Line Voltage:
85-265 V AC, 50-60 Hz
Power Consumption:
10 VA
Cleaning Sensor
IMPORTANT: Sensor must be cleaned by
hand before being inserted into the chamber!
How to clean DIS sensor:
- Remove sensor from assembly and cable
- Wipe off any pollution with paper tissue, rinse
with water
- Clean metal bands with powder detergent (ex.
Comet), wipe gently
- Rinse with water and reinstall
Calibrating Sensor
DIS Sensor
1. IMPORTANT: Clean sensor before
proceeding with calibration!
2. Using water sample taken from Sampling
Reference Valve, perform DPD test
3. Menu > Cal > Cal DIS > enter DPD
reference value > Ok > Save
Krypton Neon DIS Installation and Set Up Guide
Kuntze Instruments
3316 Leechburg Road | Lower Burrell | Pennsylvania | 15068
724-339-8510 | info@kuntzeinsturments.com | kuntzeinsturments.com
Spare Parts List
Sensors
Part Number
Name
Description
24135140K
Zirkon® DIS
Sensor: 2 gold rings, ceramic junction, Tepox gel, M12 plug (swivel PG 13.5), for Free Chlorine,
Chlorine dioxide, and Ozone
24137001K
Zirkon® FTG
Flow monitor, temperature sensor and ground for Argon Stabiflow
Cables
Part Number
Name
Description
44136406K
5SCR-M12-AE-1.0
Connection cable for disinfection sensor; Type of cable: 5-core, 5 x 0.25 Somme, screen; Cable
length: 0.8m; Type of plug: M12 (female, other end with wire sleeves; Temperature range: -
20…+70C
Rebuild Kits
To see exploded view of Argon Stabiflow, open manual to section 20.3.3 Operations and Maintenance
Part Number
Name
Description
39500005K
Argon® Connection pkg
Inlet, outlet and sample cock
3x ball valve 1/4"
2x hose attachment 1/4" 6/8 1x hose barb 1/4"
3x O-ring 6x3 FKM 3x O-ring 11x3 FKM
39500006K
Argon® spare parts pkg 1
Membrane springs and valve pin, 1 membrane, 1 spring pressure side, 1 spring chamber side, 1
valve pin
39500007K
Argon® spare parts pkg 2
Filter 5x stainless Steel 500um filter 5x o-ring FKM 26x1.5
39500008K
Argon® spare parts pkg 3
1x o-ring FKM 12x2; 1x o-ring FKM 73x2
1x o-ring FKM 26x2; 1x o-ring FKM 26x1,5
1x o-ring FKM 5x1,8; 3x o-ring FKM 6x3
1x o-ring FKM 19x2,5; 1x o-ring FKM 7,6x2,4
1x o-ring FKM 108x3; 3x o-ring FKM 11x3
39500011K
Argon® spare parts pkg 4
Spare parts inflow; 1x hex spud; 2x O-ring 26x2; 1x O-ring 5x1.8; 1x filter support; 1x ball

Other Kuntze Measuring Instrument manuals

Kuntze LF6 User manual

Kuntze

Kuntze LF6 User manual

Kuntze K 100 PR User manual

Kuntze

Kuntze K 100 PR User manual

Kuntze PM 6 Owner's manual

Kuntze

Kuntze PM 6 Owner's manual

Kuntze K 100 CM User manual

Kuntze

Kuntze K 100 CM User manual

Kuntze Krypton Multi Assembly instructions

Kuntze

Kuntze Krypton Multi Assembly instructions

Popular Measuring Instrument manuals by other brands

General EMF1394DL user manual

General

General EMF1394DL user manual

Vega MINITRAC 31 operating instructions

Vega

Vega MINITRAC 31 operating instructions

Logenex SLM-1A Operation guide

Logenex

Logenex SLM-1A Operation guide

Mark-10 7i user guide

Mark-10

Mark-10 7i user guide

Brandson 303403 user manual

Brandson

Brandson 303403 user manual

HunterLab Agera EasyMatch QC Supplemental manual

HunterLab

HunterLab Agera EasyMatch QC Supplemental manual

AMiO 02507 user manual

AMiO

AMiO 02507 user manual

Michell Instruments Pura user manual

Michell Instruments

Michell Instruments Pura user manual

HEIDENHAIN SE 661 Mounting instructions

HEIDENHAIN

HEIDENHAIN SE 661 Mounting instructions

ABB FPD350 Torbar instructions

ABB

ABB FPD350 Torbar instructions

Milwaukee pH51 user manual

Milwaukee

Milwaukee pH51 user manual

Keysight Technologies E4990A installation guide

Keysight Technologies

Keysight Technologies E4990A installation guide

PCB Piezotronics EX619A11 Installation and operating manual

PCB Piezotronics

PCB Piezotronics EX619A11 Installation and operating manual

GEO-Laser KL-90L operating instructions

GEO-Laser

GEO-Laser KL-90L operating instructions

ENDA EI7412 user manual

ENDA

ENDA EI7412 user manual

Optimus PM-812/0 operating instructions

Optimus

Optimus PM-812/0 operating instructions

Circutor WIBEEE Series instruction manual

Circutor

Circutor WIBEEE Series instruction manual

Honeywell APT4000PH user manual

Honeywell

Honeywell APT4000PH user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.