NON-CONTACT EF-DETECTION
Model - 2772
20 FUNCTIONS 21 RANGES
2000 A AC TRUE RMS DIGITAL CLAMP METER WITH
?2000AAC Clamp-on + Full Multimeter ranges
?AC True RMS Voltage & Current functions
?Autocheck feature (Automatic DCV, ACV &
Ohms selection)
?Fully Autoranging on all functions
?Back lighted display & Data Hold function
SPECIAL FEATURES :
?Non-Contact & Probe Contact EF-Detection
?Lo-Z Voltage to drain Ghost Voltages (Auto-VWposition)
?High Voltage frequency with auto-ranging trigger levels
?Overload-Alert ON > 600V AC/DC (Beeps & OL indication)
?Fast Audible Continuity & Diode Test
GENERAL SPECIFICATIONS :
ïSensing : True RMS sensing
íJaws opening size : 45mm max.
íDisplay : 3-5/6 digits 6000 counts
íUpdate Rate : 5 per second nominal
íPolarity : Automatic
íOperating Temperature : 0°C ~ 40°C
íRelative Humidity : Max. R.H. 80% for
o
temperature upto 31 C decreasing linearly to
o
50% R.H. at 40 C o o
íStorage Temperature : -20 C to 60 C, < 80% R.H.
(With battery removed)
íAltitude : Operating below 2000m
íTemperature Coefficient : Nominal 0.15 x (specified accuracy) /
o oo oo
C @ (0 C ~ 18 C or 28 C ~ 40 C) or otherwise specified.
íLow Battery Indication : Below approx. 2.4 V
íPower Supply : Standard 1.5VAAAbattery X 2
íPower Consumption : 2.8mAtypical
íAPO Consumption : 230 mAtypical on Voltage & Current function
íAPO Timing : Idle for 3 minutes
íDimension : 224(L) x 78(W) x 40(H)mm
íWeight : approx. 220gm
SAFETY :
?Safety : Meets IEC 61010-2-032(1994),
EN61010-2-031(1995), UL3111-2-032 (1999)
?Measurement Category : CAT III 600VAC & VDC.
?Pollution degree : 2
?Overload Protection :
ACA Clamp-on jaws : AC 2000A rms continuous
+ & COM terminals (all functions) : 600VDC & VAC rms
?E.M.C. : Meets EN61326 (1997,1998/A1),
EN61000 -4-2 (1995) & EN61000-4-3 (1996)
In an RF Field of 3V/m :
Capacitance function is not specified.
Other function ranges :
Total accuracy = Specified accuracy+ 45 digits
Performance above 3V/m is not specified
?Battery Cover with probe holders
?Rugged fire retarded casing
ACCESSORIES :
Test leads (pair), Batteries installed, Users Manual, Carrying Case
ELECTRICAL SPECIFICATIONS : 2772
Accuracy : ± ( % reading + number of digits)
<1.6V DC
0.4mA typical
DIODE TESTER
Open Circuit Voltage
Test Current
Audible Threshold : between 0.015V and 0.080V
50Hz / 60Hz
50Hz ~ 500Hz
AC VOLTAGE
Range
6.000 V
60.00 V
Accuracy
±(1.5%rdg + 5dgts)
±(2.0%rdg + 5dgts)
Resolution
15kW
100kW
210kW
@ 100V
@ 300V
@ 600V
CMRR : > 60dB @ DC to 60 Hz; Rs =1kW
Hi-Z ACV Input Impedance : 5 MW, 90pF nominal
AutoCheck Lo-Z DCV Input Impedance :
Initially 1.6kW, 90pF nominal ;
Impedance increases significantly as display voltage
increases from 50V (typical). Typical impedances vs
display voltages for reference are:
AutoCheck ACV Threshold : > 2VAC (50 / 60Hz) nominal
Crest Factor : < 1.6:1 at full scale & < 3.3:1 at half scale
600.0 V
6.000 V
60.00 V
600.0 V
±(2.0%rdg + 5dgts)
±(2.5%rdg + 5dgts)
1 mV
10 mV
100 mV
1 mV
10 mV
100 mV
2)
100.0 nF
1000 nF
10.00 mF
100.0 Fm
2000 Fm
3)
±(3.5%rdg + 5dgts)
Range Resolution
1)
Accuracy
CAPACITANCE
1)Accuracies with film capacitor or better.
2)Accuracy below 50 nF is not specified
3) Specified with battery voltage above 2.8V approx.
(half full battery).
Accuracy decreases gradually to 12% at low battery
warning voltage of approx 2.4V
100 pF
1 nF
10 nF
100 nF
1 mF
NON-CONTACT EF-DETECTION
Typical Voltage Bar Graph Indication
15V to 85V
40V to 130V
60V to 210V
90V to 300V
above 120V
-
- -
- - -
- - - -
- - - - -
Indication : Bar graph segments & audible beep tones
proportional to the field strength
Detection Frequency : 50/60Hz
Detection Antenna : Top side of the stationary jaw
Probe-Contact EF-Dection : For more precise indication of
live wires, use the Red(+) probe for direct contact measurement
50Hz / 60Hz
Range
400.0 A
2000 A ±(1.5%rdg + 5dgts)
Resolution
ACA CLAMP-ON CURRENT
1) 2) 3)
Accuracy
Crest Factor : < 2 at full scale & < 4 at half scale
1)
Add 8d to specified accuracy while reading is below 10%
of range.
2)
Induced error from adjacent current-carrying conductor :
< 0.06A/A.
3)
Specified accuracy is for measurement made at the jaw
center. When the conductor is not positioned at the jaw
center, position errors introduced are:
Add 1% to specified accuracy for measurementts made
WITHIN jaws marking lines (away from jaws opening).
Add 4% to specified accuracy for measurements made
BEYOND jaws marking lines (toward jaws opening).
100 mA
1 A
2)
6.000 kW
60.00 kW
600.0 kW
6.000 MW
Range
3)
±(1.2%rdg + 6dgts)
±(2.0%rdg + 4dgts)
Resolution
RESISTANCE
1)
Accuracy
±(1.0%rdg + 4dgts)
Open Circuit Voltage : 0.4VDC typical
1)
Cool down interval 2 minutes after over 50V
measurements in Auto-VWposition.
2)
Beeper ON while reading < 0.025 kW
3)
Add 40d to specified accuracy while reading is below
20% of range.
1 W
10 W
100 W
1 kW
6.000 V
60.00 V
600.0 V
FREQUENCY
4 V 10Hz ~ 30KHz
30 V 10Hz ~ 1KHz
60 V 10Hz ~ 1KHz
Voltage
Range Sensitivity
(Sine RMS) Range
Accuracy : ±(0.5%rdg + 4dgts)
Max display : 9999 counts
600Wwith CONTINUITY BEEPER
Accuracy
600.0 kW1)
±(2.0%rdg + 8dgts)
Range
Continuity Beeper Response : <100mS
Open Circuit Voltage : 0.4VDC typical
Audible Threshold : between 10Wand 300W
1)
Add 40d to specified accuracy while reading is
below 20% of range
DC VOLTAGE
Range
6.000 V
60.00 V
600.0 V
15 kW
100kW
210kW
@ 100 V
@ 300 V
@ 600 V
Accuracy
±(0.5%rdg + 3dgts)
±(1.0%rdg + 5dgts)
±(2.0%rdg + 5dgts)
Resolution
NMRR : > 30 dB @ 50 Hz / 60 Hz
CMRR : > 100 dB @ DC, 50 Hz / 60 Hz; Rs =1kW
Hi-Z DCV Input Impedance : 5 MW, 90pF nominal
AutoCheck DCV Threshold :
> + 1.5VDC or < -1.0VDC nominal
AutoCheck Lo-Z DCV Input Impedance :
Initially 1.6 kW, 90pF nominal ;
Impedance increases significantly as display voltage
increases from 50V (typical). Typical impedances vs
display voltages for reference are:
1 mV
10 mV
100 mV
Transient Protection
6.5kV (1.2/50ms)
surge