Kval 965X User manual

965X QUICK START965X QUICK START
Load Door Job from Library
965X Quick Ref 1
1. Select the Libraries Tab at the upper let side of the screen
2. Select the Door Job Libray Tab at the upper center screen
3. At the Door Job List double click the desired door job to go
to the Door Job screen
Verify Door Job
Add Jambs to Queue
Verify the Door Job specii-
cations. Look for validation
errors.
Note: For more information about Libraries,
see the KvalCam Manual.
1. Enter the quantiy of door to be processed in the Door
Qy box at the botom of the screen
2. Select the Add to Queue Buton
Before Processing a Jamb
Home the machine (Impotant: Homing sets a stating
reference point for the machine.)
1. Select the Jamb Suppot Block: Choose the pre-
determined numbered block to match the jamb
syle.
2. Select the Jamb Stop Reference: Select the
Jamb Stop placement, Jamb End or Dado.
Process a Jamb
1. Extend Clamps: Extend the Door Clamps and Door Stops,
select the Jamb Stop Foot Pedal or Toggle Stop buton at the
Main screen.
2. Load Jamb: Load the jamb onto the machine Jamb Shelf.
3. Align Jamb: Align the jamb to the Jamb Stop and the Up-
Clamp. Make sure the it is tight.
4. Clamp: Secure the Jamb. Select the Jamb Clamp Foot Ped-
al or Toggle Clamp. Warning: Keep Hands away from the
Clamps.
5. Start Sequence: Stat cuting by pressing the Stat Se-
quence buton or by selecting the Stat Sequence buton at
the Main screen. Exit the Cuting area within 3 seconds.
6. Continue or End: If continuing processing the jamb, select
the Next Group buton, reposition the jamb, and repeat Steps
1-5 above. If completed with this jamb, remove jamb and con-
tinue to next the jamb. If ending the process, park the Cuter
Head.
Important Notes
OR
OR
Jamb Stop Up-Clamp
=
w
OR
Always Park the Carriage Head during processing breaks
and at shutdown. →Go to Next Jamb
→Stop Processing
Power-Down
Power-UP
Verify Area is safe, power and air are applied,
E-Stops are out and Fence Gates are closed.
1. Turn the Electrical Disconnect to the ON
position on the Electrical Cabinet.
2. Turn the Control Circuit Switch to the
ON position. (Approximately 3 minute
boot-up)
3. Push the Stat buton.
4. Home the machine
All Tower Lights Should be Green. See reverse side
for Tower Light Description.
1. Park the Cuter Head
2. Right click the KVAL icon at the taskbar.
Select Exit from the drop down menu
Make sure Window is shutdown before
cuting o power to the machine.
3. Turn the Control Circuit Switch to the
OFF position.
4. Turn the Electrical Disconnect to the
OFF position on the Electrical Cabinet.
EXITEXIT
OR
Ater Stat Sequence, the operator must exit the cuting
area beyond the Safey Light Cutain within 3 seconds. If not
exited, the Stat Sequence will cancel. To restat, press the
Stat Sequence again and exit the cuting area within the 3
second rule.
Shape Location and Extent (Size) of Shape :
→Click location to toggle beween digital and fraction
display.
→Extent is the lenth of the shape of the cut
→Click location title to display reference of Jamb Stop to
top edge of cut or Jamb Stop to center of cut.
→Grey Background: Not used or Next Group
Categoy Desig. Descriptions
Machine Status
OFF (Clear): Machine not in operation.
White: Initializing
1 Flash: Waiting for all systems to initialize
Red: Machine Error
Solid: General Error
• 1 Flash: EtheCat Device not Ready to Run
• 2 Flashes: VFD, Sevo, or Motor Error
• 3 Flashes: 24 VDC Power Error
Yellow: External Error
Solid: General Error
• 1 Flash: 3 Phase Voltage Error
• 2 Flashes: Low Air Error
Blue: Operator Status
Solid: Waiting for Operator
• 1 Flash: Reposition Door
Green: Machine is Operational
Safey
OFF (Clear): Safey Project not Running
Red: Safey PLC Error
Blue: Waiting for Safey Re-Set
• Solid: General Error
• Flashing: Not Ready to Re-Stat (E- Stop Switch is Active)
Green: Machine is Operational
Control Power
O: No Control Power
ON (Green): 24 VDC Control Power ON
About the Light Tower
High Voltage may cause injury or death.
Troubleshooting checks must be performed
by a Qualied Electrical Technician.
The Light Tower indicates the working status of the system. The
Light Tower is mounted on top of the Electrical Boxes. Each light dis-
plays dierent colors and lashing codes to show the machine status.
The table below describes the dierent states of the Light Tower.
Be Smat! Follow all Safey Precautions.
Remote Troubleshooting
Kval’s Suppot Team is able to work remotely with your maintenance sta or contractor to diagnose and troubleshoot machiney
issues. Call (800)- 553-5825 or stat a suppot ticket Online htps://www.kvalinc.com/suppot.
Tools Needed for machine hardware troubleshooting:
• Access to a broadband internet connection
• An iPhone or Android smat-phone (We use Apple FaceTime or
Google Duo for video)
• A DMM
• A standard tool set
For machine soware troubleshooting:
• Access to a broadband internet connection
• A computer running Windows
• Our remote suppot client
Allow Kval to Logon to the Machine
• Exit the KvalCAM program. On the
Windows Screen, select the KVAL
Sevice Icon
Main Screen Summary
KvalCAM Jamb PropertiesKvalCAM Jamb Properties
Group Status and Process StatusGroup Status and Process Status
-
Clamp StatusClamp Status
-
Speed ControlSpeed Control Jamb Shelf IdentificationJamb Shelf Identification
ProcessProcess
ControlsControls
Task Locations on a Jamb
MachineMachine
ControlsControls
Task BoxesTask Boxes
Deinition of Title Bar:
→Cut Location
→Process Box-(Pending, Running,Com-
pleted, Skipped)
→Timer-The time of the cut sequence.
→Check Box- Clear check mark to skip
this cut.
Type of Cut:
→Yellow - Dado Cut
→White -Standard Cut (Hinge , Lock)
→Red - Trim Cut
→Roll mouse over the doted line to display proper-
ties of cut.
* For detailed information about the 965X , refer to the manual set.

Other manuals for 965X

2

Popular Control System manuals by other brands

LeakSmart Protect Shut-off Valve System user manual

LeakSmart

LeakSmart Protect Shut-off Valve System user manual

Rolls-Royce Helicon X3 user manual

Rolls-Royce

Rolls-Royce Helicon X3 user manual

CAME ACS-EM manual

CAME

CAME ACS-EM manual

AB Quality Allen-Bradley 1394 user manual

AB Quality

AB Quality Allen-Bradley 1394 user manual

Cleode ZigBee ZPILOT user manual

Cleode

Cleode ZigBee ZPILOT user manual

Invacare LINX ACU user manual

Invacare

Invacare LINX ACU user manual

OBSIDIAN CONTROL SYSTEMS NX4 installation guide

OBSIDIAN CONTROL SYSTEMS

OBSIDIAN CONTROL SYSTEMS NX4 installation guide

IDEC EB3N manual

IDEC

IDEC EB3N manual

Siemens Climatix HMI-LED POL831.25/STD Basic documentation

Siemens

Siemens Climatix HMI-LED POL831.25/STD Basic documentation

Leica PaveSmart 3D user manual

Leica

Leica PaveSmart 3D user manual

Lofa EP250 Operation and Troubleshooting

Lofa

Lofa EP250 Operation and Troubleshooting

Durablow TR1004 Installation & operating instructions

Durablow

Durablow TR1004 Installation & operating instructions

Graco 207-279 instructions

Graco

Graco 207-279 instructions

Pego 200SCH202HYP user manual

Pego

Pego 200SCH202HYP user manual

HEIDENHAIN POSITIP 880 installation instructions

HEIDENHAIN

HEIDENHAIN POSITIP 880 installation instructions

Casals SFC User and installation manual

Casals

Casals SFC User and installation manual

SOMFY SOLIRIS Uno installation guide

SOMFY

SOMFY SOLIRIS Uno installation guide

Invacare Linx REM500 user manual

Invacare

Invacare Linx REM500 user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.