AUXILIARY EQUIPMENT CONTROL (OPTIONAL):
SYSTEM START-UP
The standard Time Master system is provided with 3 power relaysfor controlling filter
pump, pool cleaner, andauxiliary 1 (poollight).
It is possible to control additional equipment (such as a jet pump,air blower,spa light,
etc) by installing extra relay kits (model RLY-LX). The LX-10 Service Center will
accommodateatotal of 7 relays Note: Furtherrelaysmaybecontrolledbyanaddt
tional Power Center(model
LX-36).
lnstall RLY-LX Relay Kit at the LX-10 in accordance with instructions provided.
SPAaSIDE REMOTE CONTROL (OPTIONAL):
When the spa construction is completed, install optional Spa-side Remote Control
(model SS100) in accordance with instructions provided:
1. Cut back the 11/2" dia pvc receptacle flush with spa wall finish or surface of deck
2.
Making sure that screw threads are facing out, glue adapter into receptacle using
pvc cement
3. Thread cable through gasket, and run through conduit to LX-10 low voltage
compartment
4. Before installing SS-100, rotate7 turns counterclockwise to avoid undue twisting
of cable
5. Screw SS100 into adapter and finger-tighten. Caution: Do not use wrench
6.
At the LX-10, cut off excess cable
if
necessary. Strip insulation
'/a",
and make
connections to REMOTE SWITCHES screw terminals in accordance with
wiring diagram located inside enclosure cover.
Connect black wire (switch common) to GND terminal, and connect red, yellow,
and green wires to desired terminal for SPq AUX 1, AUX
2,
AUX
3
andAUX
4.
Note: for the convenience of the serviceman, the screw terminal canbe unplugged
from printed circuit board without disconnecting wires
INDOOR REMOTE CONTROL (OPTIONAL):
Select a convenient location inside the house or other weather-protected area to
mountthe LVS-3(3buttonindoorremote) or LVSSTR(3buttonindoor remotew/ digital
temperature display).
Install in accordance with instructions provided At the LX-10 low voltage con
partment, strip jacket of cable
6"
to identify the twisted pairs and assure correct
connections Strip insulation of each wire
'/4",
and connect to appropriate screw
terminals at REMOTE SWITCHES and REMOTE LAMPS terminal:
1. Select any three circuits from SPA, AUX 1, AUX
2,
AUX
3,
and AUX
4.
2. Number the circuits 1,
2,
and 3.
3. Makesure that the correspondingSW and LMPwires from the Indoor Remoteare
connected to the appropriate circuit at the LX-10 REMOTE SWITCHES and
REMOTE LAMPSterminal.
NOTE:
If
the LVS3TR is being used install the second Water Sensor (included) in
accordance with previous instructions and run cable to LX-10 low voltage con
partment Wire nut toyellowblack pair of wires from LVS-3TRcable (redconnects to
yellow, greenconnects to black),inaccordance with wiring diagram locatedinside
LVS-3TR
A Label Set for indoor remote controls (model LBL-100) is available from
Compool Corporation. This set of
100
different labels provides custom equip
ment identification at each remote control button.
Apply power to the system.
At theTime Master,pullout batteryshieldtoactivate back-upbattery,and push HOURS
button until digital readout is displayed
At the LX-10Service center, turn SYSTEM CONTROL Switchto"SERV1CE position
and FLOW CONTROL Switch to"POOL" position.
Check that Valve Operators haverotatedtocorrect positions Toadjust position of any
valve, simply reverse the cable plug on the side of Valve Operator.
At the LX-10Service Center, turn MANUAL CONTROL Switches to"ONpositions
and check that all equipment is operating.
Turn OUTDOOR REMOTESSwitchto"ONnpositionandcheckthat optional Spa-side
Remote Control is functioning correctly.
Turn MANUALCONTROLSwitches to"OFF1positions
The system is now ready to be operated as desired
SYSTEM OPTIONS
TWO SPEED PUMP CONTROL:
If the system isequipped with a two speedfilter pump, a DualSpeed Relay Kit (model
RLY-LXD) should beadded at the LX-10 in accordance with installation instructions
provided
The system will automatically run the filter pump in high speed under any of the
following conditions
1. Whenever the heater is on
2. Whenever pool cleaner is running
3. Whenever spa is running
It ispossible to eliminate one or more of these conditions by adjusting U11 Program
Switch, which is located at the top of the printed circuit board See RLY-LXD
installation instructions for details
PROGRAMMABLE TWO SPEED PUMP CONTROL:
If the system is equipped with a two speed filter pump, it is additionally possible to
program the pump to run in high speed by using AUX
1
Program Button on the
Time Master Controller. However,this feature will only operate when thefilter pumpis
running Install RLY-LXD as above.
Adjust
U10
ProgramSwitch(locatedat the bottom of the printed circuit board) so that
Switches#1, #3 and
#6
are programmed ON, and Switches #2, #4, #5, and#7 are
programmed OFF.
ADDITIONAL VALVE CONTROL:
Itis possibletoaddvalveoperators(mode1VOR-24)tothesystemtoactuate additional
threeportvalvesfor poolcleaningorfor acustom hydraulicfeature(such as afountain,
waterfall second spa, etc). Atotal of threevalve operators may beadded. InstallValve
Module (model MODVLV1) at LX-10 low voltage compartment in accordance with
instructions provided, and connect valve operators accordingly.