KWJ-WSN CO
Wireless Carbon Monoxide Sensor
Additional Notes of Operation
Sensor Mounting and Installation Tips
• It is recommended to install sensors in a conspicu-
ous location to facilitate airow around the sensor.
• Installing sensors near an opening where CO may
be regularly present (garage door, etc.) may cause
readings to periodically spike, and may affect TWA
calculations.
• It is recommended for maximum immediate CO
protection, that the user install a UL approved
commercially available carbon monoxide de-
tector with an audible alarm, or a KWJ Alarm
Module, to work alongside the KWJ-WSN CO
modules.
Setup Considerations
It is recommended that the user install no more than 15
sensor modules per gateway due to wireless bandwidth
limitations if all sensors alarm in response to 400 ppm
simultaneously.
Default Notication Settings
• OSHA (Industrial) setting includes thresholds for 50,
125, and 400 ppm as well as 50 ppm 8-hour TWA.
• Health Level setting includes the OSHA thresholds
as well as TWA thresholds of 9, 13, 16, 25, and 35
ppm.
• NOTE: Be aware that some user-dened thresholds
may conict with the default settings. In the case of
a conict, the default notication will be applied.
Default Notication Levels
OSHA & Safety Notication Setting
Title Notify When
(all day)
Transmit
Interval
Fixed or User
Chageable
CO Exceeds 50 ppm CO > 50 ppm 10 min Fixed
CO Exceeds 125 ppm CO > 125 ppm 1 min Fixed
CO Exceeds 400 ppm CO > 400 ppm 15 sec Fixed
TWA CO Exceeds 50 ppm TWA CO > 50 ppm 10 min Fixed
Health-Level Notication Settings (Low-Level Warnings)
Title Notify When
(all day)
Transmit
Interval
Fixed or User
Chageable
CO Exceeds 25 ppm CO > 25 ppm 10 min Changeable
TWA CO Exceeds 9 ppm TWA CO > 9 ppm 10 min Changeable
TWA CO Exceeds 13 ppm TWA CO > 13 ppm 10 min Changeable
TWA CO Exceeds 16 ppm TWA CO > 16 ppm 10 min Changeable
TWA CO Exceeds 25 ppm TWA CO > 25 ppm 10 min Changeable
TWA CO Exceeds 35 ppm TWA CO > 35 ppm 10 min Changeable
Wireless Sensor
CARBON
MONOXIDE
CO
CO Safety
While your KWJ-WSN CO sensor is an excellent mea-
sure of protection from CO exposure, it is also recom-
mended that you keep the following in mind if you are
ever away from your dashboard or the device receiving
notications:
The initial symptoms of CO poisoning are similar
to the u (but without the fever). They include:
* Headache
* Fatigue
* Shortness of breath
* Nausea
* Dizziness
If you suspect that you are experiencing CO poison-
ing, leave the area and get fresh air immediately.You
could lose consciousness and die if you stay in the
affected area. Get medical attention immediately and
inform medical staff that CO poisoning is suspected.
Call the Fire Department to determine when it is safe
to reenter the area.
LIMITED WARRANTY
KWJ Engineering warrants to the original purchaser that this product shall be free from any
defect in the materials or workmanship for 1 year from the date of purchase (excluding the
battery). This warranty does not cover wear and tear due to normal use. It does not apply to any
product that has been subjected to misuse, abuse, neglect, accident, tampering or unauthorized
repairs, failure to follow the instructions in the manual, or use under conditions outside those
recommended in the data sheet. KWJ Engineering may elect to replace the unit, at no extra
cost, with the same or a similar unit rather than repair it. In the event of replacement with a new
or reconditioned instrument, the replacement unit will continue the warranty of the original unit.
If the product should become defective during the warranty period, please return it through your
distributor
,
or
call
KWJ
Engineering
at
(800)
472-6626
or
e-mail
at
[email protected] to receive return instructions and a Return Materials Authorization (RMA) number.
Except as provided herein, KWJ Engineering makes no warranties, express or implied, including
warranties of merchantability and tness for a particular purpose. KWJ Engineering shall not be
liable for loss of use of this instrument or other incidental or consequential damages, expenses
or economic loss, or claims for such damage or economic loss.
KWJ WSN, SPEC are trademarks of KWJ Engineering Inc.
©2014 KWJ Engineering Inc. All Rights Reserved.