manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. LACO Technologies
  6. •
  7. Control Unit
  8. •
  9. LACO Technologies TITAN VERSA User manual

LACO Technologies TITAN VERSA User manual

This manual suits for next models

1

Popular Control Unit manuals by other brands

Seitz 14A80 user manual

Seitz

Seitz 14A80 user manual

Wilo RS485 Installation and operating instructions

Wilo

Wilo RS485 Installation and operating instructions

Becker CentralControl CC41 Commissioning Instruction

Becker

Becker CentralControl CC41 Commissioning Instruction

SICK CDB650 operating instructions

SICK

SICK CDB650 operating instructions

Panduit NetKey NKP5E88M Series installation instructions

Panduit

Panduit NetKey NKP5E88M Series installation instructions

MX Options Concentric Petite Fitting instructions

MX

MX Options Concentric Petite Fitting instructions

Clean Water Systems Fleck 2510 Installation & start?up guide

Clean Water Systems

Clean Water Systems Fleck 2510 Installation & start?up guide

Fairchild FSB44104A user guide

Fairchild

Fairchild FSB44104A user guide

LEGRAND Wattstopper LMIN-104 installation instructions

LEGRAND

LEGRAND Wattstopper LMIN-104 installation instructions

PMK ATT10BNCS instruction manual

PMK

PMK ATT10BNCS instruction manual

Tektronix TDS3FFT user manual

Tektronix

Tektronix TDS3FFT user manual

Woodward easYgen Technical manual

Woodward

Woodward easYgen Technical manual

Balluff BNI EIP-502-105-R015 user guide

Balluff

Balluff BNI EIP-502-105-R015 user guide

NXP Semiconductors TWR-LS1021A Getting started

NXP Semiconductors

NXP Semiconductors TWR-LS1021A Getting started

Advantech PCM-3117 Startup manual

Advantech

Advantech PCM-3117 Startup manual

Danfoss MCO 101 manual

Danfoss

Danfoss MCO 101 manual

Moons' Lin Engineering R701P user manual

Moons'

Moons' Lin Engineering R701P user manual

Aventics RV1 operating instructions

Aventics

Aventics RV1 operating instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.

SMT-07-1040 A1
TITAN VERSA REMOTE I/O MODULE
User Manual
Description
The Remote I/O module (TV115893) can be connected to the Remote I/O port
with three different cable lengths: TV5839 (1M cable), TV5840 (3M cable) and
TV5841 (5M cable).
I/O Function
Total
Detail
Electrical Specifications
Digital Inputs
8
8 Bi-directional
(PNP or NPN type)
15-30 Vdc On Voltage,
Opto Isolation, 10 msec response
Digital Outputs
8
6 Relay
2 PNP transistor
Relay: DC or AC Load
Transistor: 24 VDC, 250 mA max
Analog Outputs
2
Voltage (0-10 VDC) or
Current (4-20 mA)
12-bit A-D, 0.2% of full scale
Current - max load 500 Ohm
Voltage –max load 1000 Ohm
Safety
WARNING:
•Use the I/O Module only as specified in this manual.
2
Installation
Wiring Recommendations
•Do not wire to any of the following items: Analog Input pins (CS11 –I2 and
CS31 –I4), RJ12 port, or USB micro port
•Do not wire external 24 Vdc power to 24V pin. Use this power for digital
inputs and digital outputs only
•Ensure power is off during all installation wiring
•Ensure all wire connections are neat and secured properly. Connector can
be removed for easier wiring assembly
General Wiring and Mounting
•Connect M12 cable from Remote I/O port to male M12 port on the I/O
module. This cable provides both power (24 VDC fused at 2.0 amps) and
communication bus
•Module can be mounted using two main methods
oInstall provided DIN rail section to underside of TITAN Versa
frame per picture below. Install module and add stop block on end
oInstall in separate control panel or anywhere as needed
Wiring Digital Inputs
•Wire either +24 or 0 Vdc to COM port per desired digital input type per the
table below
Digital Input Type
Wiring to Common
PNP, + voltage to input
Wire 0 VDC to COM and + Voltage to inputs
NPN style, 0 VDC to input
Wire +24 vdc to common
Wire X0 to X7 per desired application inputs.
3
Wiring Digital Outputs
•Wire + 24 Vdc to 24V pin and 0 Vdc to 0V pin. These pins are above Y0
•Y0 and Y1 can be used as 24 Vdc PNP outputs. Ensure load is less than 0.25
amps
•Wire 6 Relay outputs per diagram below
oCommons are shared between Y2 –Y4 and Y5 –Y7
oCommons can be wired with Common tied to ground or tied to
positive voltage
3085 West Directors Row, SLC Utah 84104 | 801-486-1004 | www.lacotech.com
Wiring Analog Outputs
•Connect Analog Output wiring per diagrams below
Figure 1:
Digital Output Wiring
Operation
•Power on the TITAN VERSA leak detector
•Verify the PWR and RUN LEDS on the module are on
•When inputs (X0-X7) or outputs (Y0-Y7) are on, the LED’s will illuminate
•Configure module per desired I/O settings. See Remote I/O section in the
TITAN VERSA Operations Manual (SMT-07-1037)
Maintenance and Accessories
P/N
Description
LMSA3850
Fuse, 5mm x 20mm, 2 AMP, slow blow, glass holder –
(located inside TITAN VERSA in case –Fuse F2)