In the event that you need assistance for servicing your anti-scale system, please rst contact the
professional contractor who installed the system.
Congratulations on purchasing your new Lancaster Anti-Scale System. This unit is designed to give
you many years of trouble free service. When installed in accordance with the following instructions
and if given reasonable care, reduced scale in your water system/piping will be the result. For
servicing and future inspection purposes, please le this booklet with your important documents.
ECOSENSE
RESIDENTIAL ANTI-SCALE SYSTEM
WITH THE D1400 1” IN/OUT HEAD
INSTALLATION, OPERATING
AND SERVICE MANUAL
7-UFAS-011
7-UFAS-016
7-UFAS-026
PAGE 2
OPERATING PARAMETERS:
• Water pressure: 12-125 psi.
• Water temperature: 34°F-120°F.
• pH range: 6.0-9.0.
• Maximum hardness: 25 grains per gallon.
• Hydrogen sulde, iron and manganese must be pretreated.
• Maximum chlorine 3ppm. De-chlorination is recommended.
• Do not exceed recommended ow rates.
• Designed for intermittent ows. For continuous ows please contact Lancaster Water Treatment.
• Additional equipment will be needed if using a tankless water heater. Consult factory.
• Conservative life expectancy of the mineral is 5 years minimum based on meeting the above parameters.
PACKAGING: All systems are shipped from the factory in cartons.
COMPONENTS: Fiberglass mineral tank, in/out head, installation tting package, distributor tube assembly,
mineral.
MODEL
NUMBER
MAXIMUM
SERVICE FLOW
MEDIA
CU.FT. (LBS.)
MINERAL TANK
(DIA. x HT.)
7-UFAS-011 10 GPM 0.11 (5.0) 8”x44”
7-UFAS-016 15 GPM 0.16 (7.6) 10”x54”
7-UFAS-026 25 GPM 0.26 (12.7) 13”x48”
INSTALLATION: Place system in desired location close to water supply inlet keeping far enough away
from walls and other obstructions to allow enough room for servicing the unit.
INSTALL THE ANTI-SCALE SYSTEM AS AN UPFLOW FILTER.
The words “UPFLOW INLET” and “DOWNFLOW INLET” are molded into the in/out head.
ADD MINERAL: Remove the in/out head by turning counter-clockwise. Plug the distributor tube to prevent
mineral from entering and add the mineral. Remove plug from the distributor tube and replace the in/out head.
OPTIONAL BYPASS VALVE: The use of a bypass valve is recommended for ease of maintenance. The
bypass valve connects to the in/out head using nuts that only require hand tightening. Install with red knobs in
the upward position. Press end of bypass valve with o-rings into the in/out head. HAND TIGHTEN NUTS.
Avoid getting primer and solvent cement on any part of the o-rings, bypass valve or in/out head. DO NOT use
pipe dope or any other sealant on threads. Teon tape is not necessary on the caps because of o-ring seal.
DO NOT use Vaseline or other unacceptable lubricants on o-rings. A silicone lubricant may be used on black
o-rings.
FITTING ADAPTER: V3007 1” PVC Male NPT elbow assembly comes standard with each unit. Other
options available (see page 4).
When assembling the installation tting package (inlet and outlet), connect the tting to the plumbing system
rst and then attach the nut, split ring and o-ring. Heat from soldering or solvent cements may damage the nut,
split ring and o-ring. Solder joints should be cool and solvent cements should be set before installing the nut,
split ring and o-ring. Avoid getting primer and solvent cement on any part of the o-rings, split rings, bypass
valve or in/out head.
PAGE 3
POSITION HANDLES ON OPTIONAL
BYPASS: Orient the red handles on the bypass
to point as shown below by lifting red arrow handles
straight off of bypass valve and replacing in the proper
position.
Turn bypass to the OFF position and connect to water pipes.
PLACING THE SYSTEM INTO SERVICE:
SLOWLY turn on water supply to the system. If using the optional bypass valve, slowly turn the bypass to the
UPFLOW-ON position. Open nearest cold water faucet and allow water to run until clear. Turn off faucet.
HOT WATER TANKS should be drained and ushed after the initial 30-90 days and again in a year to
remove the fallen scale in the bottom of the tank caused by the descaling action of the system. Follow the
manufacturer’s instructions when draining the tank.
FAUCET aerators and drains may plug occasionally as old scale is removed from your plumbing system and
water heater. Unscrew the aerators to clean the screens, then reinstall. You may also experience milky water
while descaling is taking place.
DISHWASHERS with existing scale buildup on the sidewalls and washing arm may need to be treated by the
use of a product like Jet-Dry® Dishwasher cleaner until all of the scale in the plumbing is dissolved. You may
nd unusual initial spotting because of the descaling taking place.
This system is not a water softener. Low or phosphate-free cleaning products are recommended to achieve
optimum results.
PAGE 4




















5/18
BP2000 Bypass valve
Item No. Qty. Part No. Description
1 2 V3151 Nut 1” Quick Connect
2 2 V3150 Split Ring
3 2 V3105 O-Ring 215
4 2 V3145 Bypass 1” Rotor
5 2 V3146 Bypass Cap
6 2 V3147 Bypass Handle
7 2 V3148 Bypass Rotor Seal Retainer
8 2 V3152 O-Ring 135
9 2 V3155 O-Ring 112
10 2 V3156 O-Ring 214
V3007 1” PVC Male
NPT Elbow Assembly
Item No. Qty. Part No. Description
1 2 V3151 Nut 1” Quick Connect
2 2 V3150 Split Ring
3 2 V3105 O-Ring 215
4 2 V3149 PVC Mans NPT Elbow
OPTIONAL:
V3007-02 1” Brass
Sweat Assembly
Item No. Qty. Part No. Description
1 2 V3151 Nut 1” Quick Connect
2 2 V3150 Split Ring
3 2 V3105 O-Ring 215
4 2 V3188 Fitting-1” Brass Sweat
OPTIONAL:
V3007-02 ¾” Brass
Sweat Assembly
Item No. Qty. Part No. Description
1 2 V3151 Nut 1” Quick Connect
2 2 V3150 Split Ring
3 2 V3105 O-Ring 215
4 2 V3188-01 Fitting-¾” Brass Sweat
OPTIONAL:
V3191-01 Vertical
Adapter Assembly
Item No. Qty. Part No. Description
1 2 V3151 Nut 1” Quick Connect
2 2 V3150 Split Ring
3 2 V3105 O-Ring 215
4 2 V3191 Vertical Adapter
















































INSTALLATION
FITTING PACKAGE
A DIVISION OF C-B TOOL CO.
1340 MANHEIM PIKE ● LANCASTER PA 17601-3196
TEL:717-397-3521 ● FAX: 717-392-0266
www.lancasterwatergroup.com
D1400
1” In/Out Head Assembly
Item No. Qty. Part No. Description
1 1 D1400 Body Assembly
2 1 V3105 Distributor Tube O-Ring
3 1 V3180 Body O-Ring
4 1 D1203 Upper Basket (not shown)

This manual suits for next models

2

Other Lancaster Water Filtration System manuals

Lancaster XFACTOR 7-LX125F-DAN-1B Service manual

Lancaster

Lancaster XFACTOR 7-LX125F-DAN-1B Service manual

Lancaster 7-LXDAN-1.5B Service manual

Lancaster

Lancaster 7-LXDAN-1.5B Service manual

Lancaster 7-LXDAN-1 Service manual

Lancaster

Lancaster 7-LXDAN-1 Service manual

Lancaster 7-LWT-UV009 Service manual

Lancaster

Lancaster 7-LWT-UV009 Service manual

Lancaster 7-LETCT-1 Service manual

Lancaster

Lancaster 7-LETCT-1 Service manual

Popular Water Filtration System manuals by other brands

My Water Filter ULTRAPURE Aragon Installation instruction

My Water Filter

My Water Filter ULTRAPURE Aragon Installation instruction

Graf one2clean+ XXL Instruction for operation and maintenance

Graf

Graf one2clean+ XXL Instruction for operation and maintenance

SMC Networks FGH Series Operation manual

SMC Networks

SMC Networks FGH Series Operation manual

Filtreco Basic combi drum 25 user manual

Filtreco

Filtreco Basic combi drum 25 user manual

Oase Filtral UVC 700 operating instructions

Oase

Oase Filtral UVC 700 operating instructions

Clean Water Systems 7500 Series Installation & start?up guide

Clean Water Systems

Clean Water Systems 7500 Series Installation & start?up guide

Diesel Performance Products, Inc. FASS FF-1001 installation manual

Diesel Performance Products, Inc.

Diesel Performance Products, Inc. FASS FF-1001 installation manual

FUHR FMC-FB-03-10 operating manual

FUHR

FUHR FMC-FB-03-10 operating manual

Eden 304S user manual

Eden

Eden 304S user manual

Adey MagnaClean Atom Installation and servicing

Adey

Adey MagnaClean Atom Installation and servicing

ViaAqua UTC-3200 Booklet

ViaAqua

ViaAqua UTC-3200 Booklet

Pentair FLECK 9100 SXT Installer manual

Pentair

Pentair FLECK 9100 SXT Installer manual

Zodiac Chlor Perfect Instructions for installation and use

Zodiac

Zodiac Chlor Perfect Instructions for installation and use

PREMIER TECH Solido SMART Operating Manual Including Operations Logbook, Manual for Installation, Commissioning and Maintenanc

PREMIER TECH

PREMIER TECH Solido SMART Operating Manual Including Operations Logbook, Manual for Installation, Commissioning and Maintenanc

Fresenius Medical Care DIASAFE 2008 K Operator instructions

Fresenius Medical Care

Fresenius Medical Care DIASAFE 2008 K Operator instructions

Kemper 712 99 004 Installation and operating manual

Kemper

Kemper 712 99 004 Installation and operating manual

Oase BioSmart 5000 operating instructions

Oase

Oase BioSmart 5000 operating instructions

Clack Res-Up S6304 quick start guide

Clack

Clack Res-Up S6304 quick start guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.