L&T Electrical & Automation OMEGA User manual

Safeguard your systems
from electrical turbulence
UW1- 80 S
PO E3 L
U
imp
12kV
:
I
:
800A
n
Ue
I
cs uc
=
I
6 k5 A
55 kA
50 kA
40 440 V ~0 /
55 ~500 / 0 V
/ 6 V660 90 ~
5 . s 6 kA 1 0
6 k .0 s3 A 3
I
wc
50 / 60 HzHz
CAT. B
IS/IEC
C IE
EN
60947-2
4 2609 7-
6 47-209
7JQ 6 7 7 00 U
r :S .No.
MA D IN N IE I D A
e r CSu i tab l fo 50°

Stabilise systems with technology.

Stabilise systems with technology.
Electrical power is the lifeline of industry, but it is
unpredictable. Just like an ocean, it can be calm one
moment and turbulent the next. You cannot predict
when a sudden dip or surge will happen, but you can
protect your installation from damage, when it does.
That’s where our highly sophisticated OMEGA ACBs
can make a world of difference to the safety of an
organisation’s employees, systems and infrastructure.
OMEGA ACB range consists of highly compact units
designed for high current, high power applications in
Low Voltage (LV) distribution network systems.
They are equipped with state-of-the-art Matrix
protection and control releases to meet the most
demandin g protection and system co-ordination
requirements. All this, with the assurance of
compliance to the ‘Safe &
Sure’ policy.
L&T Electrical & Automation
Over the last five decades, has earned a place
among the leading manufacturers of
Low Voltage Switchgear in the world, with the scale,
sophistication and range to meet global benchmarks.
E&A In keeping with our leadership position in the Indian
market, we also provide expert assistance in product
selection, installation and effective after-sales service,
across the country.
L&T Electrical & Automation (E&A) -The bedrock of stability.
2
Weather electrical storms with reliability.
Awarded ‘Overall Best Product
by an Indian Exhibitor‘
at ELECRAMA
WU 1-0 8S
LE3 PO
U
imp
2 V1 k
:
I
:
00A8
n
Ue
I
cs cu
=
I
A65 k
A55 k
A50 k
00 / ~4 440 V
00 / ~5 550 V
0 666 / 90 V ~
65 kA 1.0 s
6 3 kA 3.0 s
I
cw
50 / 60 HzHz
CAT.B
S I C I / E
E I C
EN
609 - 47 2
260947-
60947-2
0JQ 67 77 0 U
Sr.N .:o
MADE IN IND IA
lSuitab e for 50°C

Change course quickly.

Change course quickly.
The OMEGA ACB range has been designed to adapt to
changes in your requirements, and allow you to modify
or upgrade your systems with ease. This means
minimum down-time and enhanced protection at all
times.
•Meet system upgradation needs with
ease throughout the life of your product, with click-
fit, easy-to-mount front accessories like U/V and U/V
delay modules, Shunt and Closing releases.
•Enjoy total system flexibility and scalability
by adding power metering and communication
modules or by enabling/disabling each protection
function, depending on the requirement.
Get the OMEGA advantage
•Let your systems have better co-ordination
with protection devices and downstream loads,
via a wide range of protection curves and
fine adjustment of current pick-up threshold and
time-delay settings.
•Control a vast electrical installation through
Zigbee communication, along with the option of
conventional industrial communication protocols
such as MODBUS and PROFIBUS.
•Customise terminals by configuring terminal
adaptors for Vertical/Horizontal busbar
arrangements, to facilitate termination of
Aluminium and Copper busbars.
Refer page No. 127-129 for recommended busbar
sizes for termination.
•Convert ACBs easily on site from Fixed to
Draw-out or from Manual to Electrical versions.
Meet new challenges easily. 4

Match performance with prudence.

Match performance with prudence.
6
Move ahead, swiftly and safely.
OMEGA ACBs offer you the best of both worlds – high
performance coupled with a range of exclusive features
that deliver the highest level of electrical safety.
•Save valuable space with world’s most compact
ACBs, starting at just 347mm in width.
•Enjoy total reliability in even the harshest of
conditions including high ambient temperatures and
humidity levels.
•Savour operational flexibility, as the ACB
discriminates between fault zones selectively,
allowing downstream equipment to clear the fault in
a prescribed time before intervening.
Performance par excellence
Negating human error with safety features
•No Arc-chute, No closure: Unique features like
Arc-chute Interlocking and True Ready-to-Close
(RTC) detection systems ensure that the ACB closes
only when the Arc-chutes are in place and all other
pre-requisite conditions are fulfilled.
•Power ON, No racking operation: An inbuilt
Smart racking-shutter ensures that the ACB is
racked-in/out only in 'OFF-state'.
•One signal, One closure: An inbuilt Electrical and
Mechanical Anti-pumping System cancels the
persistent closi ng signal after successful ACB
closure.
•No unauthorised setting changes: An innovative
Password Protection feature ensures that only
authorised perso nnel can change the release
settings.

Adopt technological brilliance.

Adopt technological brilliance.
OMEGA ACBs are loaded with superior technology,
across three frame sizes for the entire current range
from 400A to 6300A. These features, including
systems for communication, control and protection
(Matrix), make these ACBs a dream to use.
•View a snapshot of all parameters and symptoms
through a user-friendly, state-of-the-art O-LED
Display.
• Control the system parameters of vast installations
easily, with a special Smart-card feature and
user–friendly Touch-Screen Display.
• Manage energy consumption better by monitoring
various energy parameters such as phase
components, power factors, energy and maximum
demand.
• Communicate between system elements wirelessly
and stay informed at all times through mobile alerts.
• Add and remove Arc-chutes and various Volt-
metric releases easily, without the need for tools.
• Upgrade systems for safety, protection, control
and monitoring with a wide range of accessories
and safety interlocks for versatile applications.
• Enjoy the benefit of total system compliance with
all the relevant quality, safety and environmental
standards.
OMEGA ACBs allow you to:
8
Enjoy total peace of mind.
E&A
E&A
's wide range of Electrical Standard Products
includes powergear, controlgear, energy management
devices, building electrical and automation products –
each of which matches and exceeds global benchmarks
for reliability and quality. However, in order to ensure
that your business sails smoothly through any electrical
turbulence, every element must be in perfect working
condition.
At , we offer you the benefit of five decades of
experience in providing After-Sales Service for Low
Voltage Distribution Systems in every type of industry
and building in India.
• Preventive Maintenance: Advice is provided and
preventive checks carried out on a regular basis.
• Service On Call: A network of over 100 approved
Service Centres across India ensures that service is
just a phone call away.
• Annual Maintenance Contract: Comprehensive
care for your systems including Obsolescence
Management and Part Replacement, as deemed
necessary.
•Obsolescence Management: We offer spares and
retro-fitment services, including upgrading all L&T
Switchgear, to ensure that your systems run
smoothly.
• Training on Product Usage: Our service engineers
work with customers' maintenance staff to train
The Service Advantage
E&A

Keep an eye on upkeep.

Keep an eye on upkeep.
10
Sail smoothly to greater success.
To find the perfect OMEGA ACB to protect your
systems from electrical turbulence, turn the page.
Special Applications-
800V AC/1000V AC Rated Voltage Applications:
Specially designed OMEGA ACB range offers a solution for electrical applications with system voltages of 800V and
1000V AC. This range of ACBs maintain the same dimension and accessories as the standard 690V AC range. This
range of ACBs is available with LSI and LSING Protections through following Microprocessor Releases -
1) MTX1.0 - LSI Protection
2) MTX1G - LSING Protection
3) MTX1.5G - LSING Protection with Current Metering
4) MTX1Gi - LSING Protection with Inbuilt ZSI
5) MTX1.5Gi - LSING Protection with Current Metering & Inbuilt ZSI
6) MTX3.5 & Above - LSING Protection with Current Metering & optional / Inbuilt Communication
(Please contact Our Sales Office for details about available advance Measurement / Protection & Features).
This Range of ACBs available for Current Ratings 400A-6300A in N Version therefore it offers
Icu=Ics=Icw (1Sec) = 50kA.
NOTE:
Please contact our nearest Sales Office for further technical and ordering details.
ewN

UW1-08S
/ C 0 4 I IE6 9 - S 7 2
E 0
C 6 94 - 2I 7
E 0 7 2
N 6 4 9 -
50 Hz / 60 Hz
65 kA 1.0 s
65 kA
55 kA
50 kA
400 / 440 V~
500 / 550 V~
660 / 690 V~
Sr.No.:
MADE IN INDIA
t l fo 50°CSui abe r
Uimp 12kV
UeII
cs cu
=
:
I
:
800A
3 POLE
I
cw
36 kA 3.0 s
JQ677 00U7
CAT.B
n
?? ? ?
? ? ?

UW1-08S
/ C 0 4 I IE6 9 - S 7 2
E 0
C 6 94 - 2I 7
E 0 7 2
N 6 4 9 -
50 Hz / 60 Hz
65 kA 1.0 s
65 kA
55 kA
50 kA
400 / 440 V~
500 / 550 V~
660 / 690 V~
Sr.No.:
MADE IN INDIA
t l fo 50°CSui abe r
Uimp 12kV
UeII
cs cu
=
:
I
:
800A
3 POLE
I
cw
36 kA 3.0 s
JQ677 00U7
CAT.B
n
?? ? ?
? ? ?
INDEX
132
69
25
83
91
13
ACB Ordering Information
Accessories
Matrix Protection & Control Units
Control Circuit Wiring
Mounting & Termination
Air Circuit Breakers

WU 1- 08 S
3 POLE
U
pim
12kV
:
I
:
0 8 0A
n
Ue
I
cs cu
=
I
65 kA
55 kA
50 kA
0 V ~40 / 440
0 V ~50 / 550
690 V ~660 /
65 kA 1. s 0
36 kA 3. s 0
I
cw
0 /5 60 HzHz
CAT. B
C IS/IE
IEC
EN
60947-2
60947 2-
60947-2
JQ 6 7 7 0 0 U7
Sr.No.:
MAD IN D AE IN I
Su ab l o 5it e f r 0°C
W 8U 1 -0 S
3 POLE
U
imp
1 kV2
:
I
:
0 8 0A
n
Ue
I
cs cu
=
I
56 kA
55 kA
05 kA
00 440 V ~4 /
00 550 V ~5 /
660 / 690 V ~
k 65 A 1.0 s
k 36 A 3.0 s
I
cw
50 / 60 z HHz
A .C T B
S/IEC I
EC I
N E
9 60 47-2
76094 -2
6 940 7-2
J 677700UQ
r .:S .No
AD I N AM E N I DI
i ab e f r50 °Su t l o C
UW -081 S
S I C 7 2 I /E 0 4 - 6 9
6 9 7 -I C 0 4 E 2
N 0E 6 4 - 9 7 2
0 6 H5 Hz / 0 z
65 kA 1.0 s
65 kA
55 kA
50 kA
400 / 40 V~4
500 / 50 V~5
660 / 690 V~
.No :Sr .
M INDIAADE IN
Su tab e for 50°Ci l
Uimp 12kV
UeII
cs cu
=
:
I
:
800A
3 POLE
I
cw
36 kA .0 3 s
JQ677700U
CAT.B
n
1UW -08S
3 P LO E
U
mi p
21 kV
:
I
:
00A8
n
Ue
I
sc uc
=
I
65 kA
55 kA
50 kA
400 / 440 V ~
500 / 550 V ~
0 9 V ~66 / 6 0
65 kA .0 s 1
3 kA .0 s 6 3
I
cw
50 / 60 zHHz
TCA . B
I /IE S C
I C E
EN
60947-2
0 76 94 -2
4 2609 7-
7 0JQ 6 77 0 U
S .No .:r
I DMADE I N N IA
Suit able f or 5 0°C
U 1-0W 8S
L3 PO E
U
mi p
12kV
:
I
:
8 00A
n
Ue
I
cs cu
=
I
65 kA
55 kA
50 A k
400 / 440 V ~
0 5 V 5 0 / 50 ~
6 66 0 / 90 V ~
65 kA 1. s0
. s 36 kA 3 0
I
cw
0 Hz50 / 6Hz
CAT.B
IS I C/ E
IEC
N E
0 - 6 947 2
9 -60 47 2
06 947-2
J 6 7 7 00 UQ 7
Sr. :No.
A E I DM D IN N IA
e 0 CSuit ab l for 5 °

WU 1- 08 S
3 POLE
U
pim
12kV
:
I
:
0 8 0A
n
Ue
I
cs cu
=
I
65 kA
55 kA
50 kA
0 V ~40 / 440
0 V ~50 / 550
690 V ~660 /
65 kA 1. s 0
36 kA 3. s 0
I
cw
0 /5 60 HzHz
CAT. B
C IS/IE
IEC
EN
60947-2
60947 2-
60947-2
JQ 6 7 7 0 0 U7
Sr.No.:
MAD IN D AE IN I
Su ab l o 5it e f r 0°C
W 8U 1 -0 S
3 POLE
U
imp
1 kV2
:
I
:
0 8 0A
n
Ue
I
cs cu
=
I
56 kA
55 kA
05 kA
00 440 V ~4 /
00 550 V ~5 /
660 / 690 V ~
k 65 A 1.0 s
k 36 A 3.0 s
I
cw
50 / 60 z HHz
A .C T B
S/IEC I
EC I
N E
9 60 47-2
76094 -2
6 940 7-2
J 677700UQ
r .:S .No
AD I N AM E N I DI
i ab e f r50 °Su t l o C
UW -081 S
S I C 7 2 I /E 0 4 - 6 9
6 9 7 -I C 0 4 E 2
N 0E 6 4 - 9 7 2
0 6 H5 Hz / 0 z
65 kA 1.0 s
65 kA
55 kA
50 kA
400 / 40 V~4
500 / 50 V~5
660 / 690 V~
.No :Sr .
M INDIAADE IN
Su tab e for 50°Ci l
Uimp 12kV
UeII
cs cu
=
:
I
:
800A
3 POLE
I
cw
36 kA .0 3 s
JQ677700U
CAT.B
n
1UW -08S
3 P LO E
U
mi p
21 kV
:
I
:
00A8
n
Ue
I
sc uc
=
I
65 kA
55 kA
50 kA
400 / 440 V ~
500 / 550 V ~
0 9 V ~66 / 6 0
65 kA .0 s 1
3 kA .0 s 6 3
I
cw
50 / 60 zHHz
TCA . B
I /IE S C
I C E
EN
60947-2
0 76 94 -2
4 2609 7-
7 0JQ 6 77 0 U
S .No .:r
I DMADE I N N IA
Suit able f or 5 0°C
U 1-0W 8S
L3 PO E
U
mi p
12kV
:
I
:
8 00A
n
Ue
I
cs cu
=
I
65 kA
55 kA
50 A k
400 / 440 V ~
0 5 V 5 0 / 50 ~
6 66 0 / 90 V ~
65 kA 1. s0
. s 36 kA 3 0
I
cw
0 Hz50 / 6Hz
CAT.B
IS I C/ E
IEC
N E
0 - 6 947 2
9 -60 47 2
06 947-2
J 6 7 7 00 UQ 7
Sr. :No.
A E I DM D IN N IA
e 0 CSuit ab l for 5 °
Ø
Ø
Ø
Ø
Ø
Ø
Ø
Ø
Ø
Ø
Complete range conforms to IS/IEC 60947-2 & IEC 60947-2
Current rating from 400A to 6300A in 3 frame sizes
Available in 3 Pole/4 Pole, Manually & Electrically operated, Fixed & Draw-out versions
Common Height & Depth across the range
High short-time fault withstanding capacity, Icu = Ics = Icw for 1 sec for total selectivity
High mechanical and electrical operating life
Modular & snap-fit accessories
Ease of on-site conversion from Fixed to Draw-out & Manual to Electrical versions
Best in class Termination overlap with Bus bars.
RoHS compliant
14
ACBs
800A 1000A 1250A 1600A 2000A 2500A 3200A 4000A 5000A 6300A
N : 50kA
N : 50kA
S : 65kA
H : 80kA
Frame-1
S : 65kA
H : 80kA
Frame-2
H : 80kA
V : 100kA
Frame-3
UW1-08
UW2-08
UW3-08
UW1-10
UW2-10
UW3-10
UW1-12
UW2-12
UW3-12
UW1-16
UW2-16
UW3-16
UW1-20
UW2-20
UW3-20
UW1-25
UW2-25
UW3-25
UW2-32
UW3-32 UW3-40 UW3-50 UW3-63
Icu = Ics = Icw
Breaking Capacities:
Rated current
Note: 400A & 630A versions also available.
UW1-08S
POLE3
U
imp
12kV
:
I
:
800A
n
Ue
I
cs cu
=
I
5 A6 k
5 A5 k
0 A5 k
40 / 440 V ~0
50 / 550 V ~0
66 / 6 0 V0 9 ~
65 kA 1.0 s
36 kA 3.0 s
I
cw
50 / 0 6 HzHz
CA . T B
/ C ISIE
C IE
EN
60 47 9 -2
60947-2
60947-2
JQ677700U
r :S .No.
E IAMAD IN IN D
ita le fo 5Su b r 0° C
UW2-40
ewN
New
ewN

15 Technical Data Sheet
(1) Please consult branch office for selection
(2) Frame-2 4000A available in S & H Version only
O
(3) Rated Uninterrupted Current (In) (A) at 40 C
(4) Available till 3200A
Break Time (ms)
Closing Time (ms)
(7)
Mechanical Life
50
42
36
50
50
26
105
88
76
65
55
50
65
65
36
143
121
105
upto 690V AC
1000V AC
12kV (Main Circuit) & 4kV (Auxiliary Circuit)
IP53 Standard, IP54 Optional
IS / IEC 60947 (Part-2), EN 60947-2, IEC 60947-2
324
421
80
65
55
80
80
44
176
143
121
10000
20000
20000
347
447
347
447
65
55
50
Rated Ultimate S.C.
Breaking Capacity
Rated Service S.C.
Breaking Capacity
Rated Short-time
Withstand Capacity
Rated S.C. Making
Capacity
(7)
Electrical Life
Ue
Ui
Uimp
415/440V AC
500/550V AC
660/690V AC
415/440V AC
500/550V AC
660/690V AC
0.5sec
1.0sec
3.0sec
415/440V AC
500/550V AC
660/690V AC
Icu (kA)
Ics (kA)
Icw (kA)
Icm (kA)
With Routine maintenance
With Specific maintenance
With Routine maintenance
15000
15000
5000
447
581
447
581
80
70
65
100
85
75
80
70
65
100
85
75
5000 2000
10000
10000
Fixed ACB
Width 3P
Width 4P
Depth
Height
Width 3P
Width 4P
Depth
Height
Dimensions
W (mm)
D (mm)
H (mm)
W (mm)
D (mm)
H (mm)
647
847
334
647
847
431
Draw-out
ACB
Frame
0
Rated Uninterrupted Current (In) (A) at 50 C
Version
Rated Operational Voltage at 50/60 Hz.
Rated Insulation Voltage at 50/60 Hz.
Rated Impulse withstand Voltage
Suitability for Isolation
Degree of Protection on Breaker front
Degree of Impact Protection on Breaker front
Pollution Degree Suitability
Utilization Category
Compliance
N
400-2000
S
400-5000 (3)
6300
H
1
Yes
4
B
100% Icu
25
60
430
433
65
55
50
65
65
36
143
121
105
5000
(1)
2500
S H S
(2)
400-4000
H H V H V
23
(4)
N
50
42
36
80
65
55
80
80
44
176
143
121
50
50
26
105
88
76
65
65
44
143
121
105
80
80
50
176
154
(6)
143
80
80
65
176
154
143
100
100
75
220
187
165
80
80
65
176
154
143
100
100
75
220
187
165
80
70
(5)
65
Operational Temperature Range
(As per IEC 60068-2-1/ IEC 60947-1-Q)
Storage Temperature Range
(As per IEC 60068-2-1/2)
IK08 Standard, IK10 Optional
O O
-25 C to 70 C
O O
-40 C to 85 C
(5) 65kA upto 3200A & 55kA for 4000A
(6) 143kA upto 3200A & 121kA for 4000A
(7) Value corresponds operating cycle
Refer Users’ Manual for Routine/Specific maintenance
Circuit Breaker upto 690V AC :

15 Technical Data Sheet
(1) Please consult branch office for selection
(2) Frame-2 4000A available in S & H Version only
O
(3) Rated Uninterrupted Current (In) (A) at 40 C
(4) Available till 3200A
Break Time (ms)
Closing Time (ms)
(7)
Mechanical Life
50
42
36
50
50
26
105
88
76
65
55
50
65
65
36
143
121
105
upto 690V AC
1000V AC
12kV (Main Circuit) & 4kV (Auxiliary Circuit)
IP53 Standard, IP54 Optional
IS / IEC 60947 (Part-2), EN 60947-2, IEC 60947-2
324
421
80
65
55
80
80
44
176
143
121
10000
20000
20000
347
447
347
447
65
55
50
Rated Ultimate S.C.
Breaking Capacity
Rated Service S.C.
Breaking Capacity
Rated Short-time
Withstand Capacity
Rated S.C. Making
Capacity
(7)
Electrical Life
Ue
Ui
Uimp
415/440V AC
500/550V AC
660/690V AC
415/440V AC
500/550V AC
660/690V AC
0.5sec
1.0sec
3.0sec
415/440V AC
500/550V AC
660/690V AC
Icu (kA)
Ics (kA)
Icw (kA)
Icm (kA)
With Routine maintenance
With Specific maintenance
With Routine maintenance
15000
15000
5000
447
581
447
581
80
70
65
100
85
75
80
70
65
100
85
75
5000 2000
10000
10000
Fixed ACB
Width 3P
Width 4P
Depth
Height
Width 3P
Width 4P
Depth
Height
Dimensions
W (mm)
D (mm)
H (mm)
W (mm)
D (mm)
H (mm)
647
847
334
647
847
431
Draw-out
ACB
Frame
0
Rated Uninterrupted Current (In) (A) at 50 C
Version
Rated Operational Voltage at 50/60 Hz.
Rated Insulation Voltage at 50/60 Hz.
Rated Impulse withstand Voltage
Suitability for Isolation
Degree of Protection on Breaker front
Degree of Impact Protection on Breaker front
Pollution Degree Suitability
Utilization Category
Compliance
N
400-2000
S
400-5000 (3)
6300
H
1
Yes
4
B
100% Icu
25
60
430
433
65
55
50
65
65
36
143
121
105
5000
(1)
2500
S H S
(2)
400-4000
H H V H V
23
(4)
N
50
42
36
80
65
55
80
80
44
176
143
121
50
50
26
105
88
76
65
65
44
143
121
105
80
80
50
176
154
(6)
143
80
80
65
176
154
143
100
100
75
220
187
165
80
80
65
176
154
143
100
100
75
220
187
165
80
70
(5)
65
Operational Temperature Range
(As per IEC 60068-2-1/ IEC 60947-1-Q)
Storage Temperature Range
(As per IEC 60068-2-1/2)
IK08 Standard, IK10 Optional
O O
-25 C to 70 C
O O
-40 C to 85 C
(5) 65kA upto 3200A & 55kA for 4000A
(6) 143kA upto 3200A & 121kA for 4000A
(7) Value corresponds operating cycle
Refer Users’ Manual for Routine/Specific maintenance
Circuit Breaker upto 690V AC :
16
Technical Data Sheet
(1) Value corresponds operating cycle
(2) With necessary component replacement
Break Time (ms)
Closing Time (ms)
(1)
Mechanical Life
Rated Ultimate S.C.
Breaking Capacity
Rated Service S.C.
Breaking Capacity
Rated Short-time
Withstand Capacity
Rated S.C. Making
Capacity
(1)
Electrical Life
Ue
Ui
Uimp
800V AC
Icu (kA)
Ics (kA)
Icw (kA)
Icm (kA)
With Routine maintenance
(2)
With Specific maintenance
With Routine maintenance
Fixed ACB
Width 3P
Width 4P
Depth
Height
Width 3P
Width 4P
Depth
Height
Dimensions
W (mm)
D (mm)
H (mm)
W (mm)
D (mm)
H (mm)
Draw-out
ACB
Frame
0
Rated Uninterrupted Current (In) (A) at 50 C
Version
Rated Operational Voltage at 50/60 Hz.
Rated Insulation Voltage at 50/60 Hz.
Rated Impulse withstand Voltage
Suitability for Isolation
Degree of Protection on Breaker front
Degree of Impact Protection on Breaker front
Pollution Degree Suitability
Utilization Category
Compliance
N08
400-2000 400-6300 400-3200
1232
Operational Temperature Range
(As per IEC 60068-2-1/ IEC 60947-1-Q)
Storage Temperature Range
(As per IEC 60068-2-1/2)
Circuit Breaker 800V AC & 1000V AC :
800V AC
0.5 sec
1.0 sec
3.0 sec
800V AC
400-3200
N10
800V AC 1000V AC
12kV (Main circuit) & 4kV (Auxiliary circuit)
Yes
IP53 Standard, IP54 Optional
IK08 Standard, IK10 Optional
4
B
IS / IEC 60947 (Part-2), EN 60947-2, IEC 60947-2
O O
-25 C to 70 C
O O
-40 C to 85 C
50
-
-
-
105
50
50
105
105
100% Icu 100% Icu
100% Icu
50
50
50
25
60
50
50
50
25
60
20000
20000
1000
347
447
347
447
15000
15000
1000
447
581
447
581
10000
10000
1000
647
847
334
647
847
431
15000
15000
500
447
581
324
447
581
421
324
430
421
433
1000V AC
1000V AC
1000V AC
50
50
36
1000V AC 1250V AC

17 Technical Data Sheet
H
W
H : Height
W : Width
D : Depth with flat terminals
D
Rating Specification Parameters for 50% N ACB
Dimensions Fixed ACB
Draw out ACB
Frame
Version
O
Rated Uninterrupted Current at 50 C
III
H/V
3200-6300
747
747
In (A)
W (mm)
Rating Specification Parameters for 200% N ACB
Dimensions Fixed ACB
Draw out ACB
Frame
Version
O
Rated Uninterrupted Current at 50 C
I
N & S
400-1250
447
447
II
S & H
(1)
1600 -2000
581
581
III
H
2000-2500
647
647
In (A)
W (mm)
Circuit breaker upto 690V AC:
II
S
4000
581
581
(1) 1600A N also available

17 Technical Data Sheet
H
W
H : Height
W : Width
D : Depth with flat terminals
D
Rating Specification Parameters for 50% N ACB
Dimensions Fixed ACB
Draw out ACB
Frame
Version
O
Rated Uninterrupted Current at 50 C
III
H/V
3200-6300
747
747
In (A)
W (mm)
Rating Specification Parameters for 200% N ACB
Dimensions Fixed ACB
Draw out ACB
Frame
Version
O
Rated Uninterrupted Current at 50 C
I
N & S
400-1250
447
447
II
S & H
(1)
1600 -2000
581
581
III
H
2000-2500
647
647
In (A)
W (mm)
Circuit breaker upto 690V AC:
II
S
4000
581
581
(1) 1600A N also available
UW1-08S
3 POLE
U
imp
12kV
:
I
:
800A
n
Ue
I
cs cu
=
I
65 kA
55 kA
50 kA
400 / 440 V ~
500 / 550 V ~
660 / 690 V ~
65 kA 1.0 s
36 kA 3.0 s
I
cw
50 / 60 HzHz
CAT. B
IS/IEC
IEC
EN
60947-2
60947-2
60947-2
6 7J Q 7 7 0 0 U
Sr. o.N :
MADE IN I NDIA
Suitable for 5 0°C
18
Identification
2a - Type designation for Electrical
Charging device (ECD)
2b - Operating voltage for ECD
4a - Type designation for Under-
voltage release (UVR)
4b - Operating voltage for UVR
5a - Type designation for Closing
release (CR)
5b - Operating voltage for CR
6a - Type designation for Shunt
release (SR/SRW)
6b - Operating voltage for SR/SRW
12 - ON-OFF indication
13 - Spring status indication
04
06
08
10
12
16
20
25
32
40
50
63
Rated
Uninterrupted
Current (In)
UUWW11--1166SS
Version for
Breaking
Capacity
29a - 29b - Rated Uninterrupted Current
29c - Rated impulse withstand voltage
29d - Utilization Category
29e - Suitability for isolation
29f - Standards compliance
29g - Rated Service breaking capacity
29h - Rated operational voltage
29j - Rated short-time withstand current
29k - No. of Pole & Pole details
400A
630A
800A
1000A
1250A
1600A
2000A
2500A
3200A
4000A
5000A
6300A
N
S
H
V
N08
N10
50 kA
65 kA
80 kA
100 kA
50 kA, 800V AC
50 kA, 1000V AC
1
2
3
Frame 1
Frame 2
Frame 3
29b
29g
29h
29j
29a
29c
29e
29f
29d
29k
CHARGED
DISCHARGED
O
OFF
I
ON
12
13
Shunt Release
415~,400V
Closing Release
415~,400V
Charging Device
240V~,240V
2a
2b
UV Release
415~,400V
UW1-08S
L3 PO E
U
pim
12kV
:
I
:
800A
n
Ue
I
cs cu
=
I
65 kA
A55 k
50 kA
00 / 4 0 4 4 V ~
0 / 50 550 V ~
660 / 690 V ~
65 kA 1.0 s
3 k 3 0 6 A . s
I
cw
50 / 60 HzHz
CA .T B
I /S IEC
EI C
EN
4609 7-2
94 260 7-
60947-2
JQ677700U
NSr. o. :
M DE I IN I AA N D
uit a fo r 0°S bl e 5 C

24b
10
6
5
21
8b
3a
4c
4
2
12
13
14 7
1
33
18
11a
11
11b 29
31
32
Breaker:
1Protection & Control Unit
2Electrical Charging Device
3a Auxiliary Contacts
4Under-voltage Release
4c Under-voltage Release Controller
5Closing Release
6Shunt Release
7Ready-To-Close (Microswitch)
8b Secondary Isolating Contacts
on Breaker
10 Operation Counter
12 ON-OFF Indication
13 Spring Status Indication
14 Charging Handle
21 Arc-Chute
24b Lifting Location on Breaker
33 Projection for resting Breaker on Cradle
Facia:
11 Shroud for ON-OFF Buttons
11a OFF Button
11b ON Button
18 OFF Button locking
29
31 Cover for Protection & Control
Unit (UW-MTX Releases)
32 Facia Fixing screw
Laser Marked Breaker
Specifications
19 Breaker Details
Table of contents
Popular Circuit Breaker manuals by other brands

ETI
ETI EFI-4B Instructions for mounting

Rockwell Automation
Rockwell Automation Allen-Bradley 140G-G manual

Siemens
Siemens SIRIUS S3 3RV1.4 Original operating instructions

Westinghouse
Westinghouse DB-50 instructions

Siemens
Siemens 3WN6 Operating instruction

Siemens
Siemens 3VA24 H Series operating instructions