Lanner LEC-6041 Series User manual

LEC-6041 User Manual
1
Version: 1.8
Date of Release:2023-09-05

LEC-6041 User Manual
2
This manual describes the overview of the various functionalities of this product, and the information you
need to get it ready for operation. It is intended for those who are:
-responsible for installing, administering and troubleshooting this system or Information Technology
professionals.
-assumed to be qualified in the servicing of computer equipment, such as professional system
integrators, or service personnel and technicians.
The icons are used in the manual to serve as an indication of interest topics or important messages.
Icon
Usage
This mark indicates that there is something you should pay special
attention to while using the product.
This mark indicates that there is a caution or warning and it is
something that could damage your property or product.
To obtain additional documentation resources and software updates for your system, please visit the
Lanner Download Center. As certain categories of documents are only available to users who are logged
in, please be registered for a Lanner Account at http://www.lannerinc.com/ to access published documents
and downloadable resources.
In addition to contacting your distributor or sales representative, you could submit a request at our Lanner
Technical Support and fill in a support ticket to our technical support department.
Your feedback is valuable to us, as it will help us continue to provide you with more accurate and relevant
documentation. To provide any feedback, comments or to report an error, please email
[email protected]m. Thank you for your time.
This document is copyrighted © 2023 by Lanner Electronics Inc. All rights are reserved. The original
manufacturer reserves the right to make improvements to the products described in this manual at any
time without notice. No part of this manual may be reproduced, copied, translated or transmitted in any
form or by any means without the prior written permission of the original manufacturer. Information
provided in this manual is intended to be accurate and reliable. However, the original manufacturer
assumes no responsibility for its use, nor for any infringements upon the rights of third parties that may
result from such use.
Note or Information
Warning or Important

LEC-6041 User Manual
3
Taiwan Corporate Headquarters
Lanner Electronics Inc.
7F, No.173, Sec.2, Datong Rd.
Xizhi District, New Taipei City 22184,
Taiwan
立端科技股份有限公司
221 新北市汐止區
大同路二段 173 號7樓
T: +886-2-8692-6060
F: +886-2-8692-6101
China
Beijing L&S Lancom Platform Tech. Co., Ltd.
Guodong LOFT 9 Layer No. 9 Huinan Road,
Huilongguan Town, Changping District, Beijing
102208 China
T: +86 010-82795600
F: +86 010-62963250
E: service@ls-china.com.cn
USA
Lanner Electronics Inc.
47790 Westinghouse Drive
Fremont, CA 94539
T: +1-855-852-6637
F: +1-510-979-0689
E: sales_us@lannerinc.com
Canada
Lanner Electronics Canada Ltd
3160A Orlando Drive
Mississauga, ON
L4V 1R5 Canada
T: +1 877-813-2132
F: +1 905-362-2369
E: sales_ca@lannerinc.com
Europe
Lanner Europe B.V.
Wilhelmina van Pruisenweg 104
2595 AN The Hague
The Netherlands
T: +31 70 701 3256
E: sales_eu@lannerinc.com

LEC-6041 User Manual
4
Intel® and Intel® Atom® are trademarks of Intel Corporation or its subsidiaries in the U.S. and/or other countries.
Microsoft Windows and MS-DOS are registered trademarks of Microsoft Corp.
All other product names or trademarks are properties of their respective owners.
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of
FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential
installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in
accordance with the instruction, may cause harmful interference to radio communications. However, there is no
guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference
to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged
to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.
Any changes or modifications not expressly approved by the party responsible for compliance could void the user's
authority to operate this equipment.
This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.
Note
1. An unshielded-type power cord is required in order to meet FCC emission limits and also to prevent interference
to the nearby radio and television reception. It is essential that only the supplied power cord be used.
2. Use only shielded cables to connect I/O devices to this equipment.
3. Changes or modifications not expressly approved by the party responsible for compliance could void the user’s
authority to operate the equipment.
Important
1. Operations in the 5.15-5.25GHz band are restricted to indoor usage only.
2. This device meets all the other requirements specified in Part 15E, Section 15.407 of the FCC Rules.

LEC-6041 User Manual
5
Follow these guidelines to ensure general safety:
Keep the chassis area clear and dust-free during and after installation.
Do not wear loose clothing or jewelry that could get caught in the chassis. Fasten your tie or scarf and roll up your
sleeves.
Wear safety glasses if you are working under any conditions that might be hazardous to your eyes.
Do not perform any action that creates a potential hazard to people or makes the equipment unsafe.
Disconnect all power by turning off the power and unplugging the power cord before installing or removing a
chassis or working near power supplies
Do not work alone if potentially hazardous conditions exist.
Never assume that power is disconnected from a circuit; always check the circuit.
Suivez ces consignes pour assurer la sécuritégénérale :
Laissez la zone du châssis propre et sans poussière pendant et après l’installation.
Ne portez pas de vêtements amples ou de bijoux qui pourraient être pris dans le châssis. Attachez votre cravate ou
écharpe et remontez vos manches.
Portez des lunettes de sécurité pour protéger vos yeux.
N’effectuez aucune action qui pourrait créer un danger pour d’autres ou rendre l’équipement dangereux.
Coupez complètement l’alimentation en éteignant l’alimentation et en débranchant le cordon d’alimentation avant
d’installer ou de retirer un châssis ou de travailler à proximité de sources d’alimentation.
Ne travaillez pas seul si des conditions dangereuses sont présentes.
Ne considérez jamais que l’alimentation est coupée d’un circuit, vérifiez toujours le circuit. Cet appareil génère,
utilise et émet une énergie radiofréquence et, s’il n’est pas installé et utilisé conformément aux instructions des
fournisseurs de composants sans fil, il risque de provoquer des interférences dans les communications radio.
There is risk of explosion if the battery is replaced by an incorrect type.
Dispose of used batteries according to the instructions.
Installation should be conducted only by a trained electrician or only by an electrically trained person who knows
all installation procedures and device specifications which are to be applied.
Do not carry the handle of power supplies when moving to another place.
Please conform to your local laws and regulations regarding safe disposal of lithium battery.
Disposal of a battery into fire or a hot oven, or mechanically crushing or cutting of a battery can result in an
explosion.
Leaving a battery in an extremely high temperature environment can result in an explosion or the leakage of
flammable liquid or gas.
A battery subjected to extremely low air pressure may result in an explosion or the leakage of flammable liquid or
gas.
Risque d’explosion si la pile est remplacée par une autre d’un mauvais type.
Jetez les piles usagées conformément aux instructions.
L’installation doit être effectuée par un électricien formé ou une personne formée à l’électricité connaissant toutes
les spécifications d’installation et d’appareil du produit.
Ne transportez pas l’unité en la tenant par le câble d’alimentation lorsque vous déplacez l’appareil.
Electrical equipment generates heat. Ambient air temperature may not be adequate to cool equipment to
acceptable operating temperatures without adequate circulation. Be sure that the room in which you choose to
operate your system has adequate air circulation.
Ensure that the chassis cover is secure. The chassis design allows cooling air to circulate effectively. An open
chassis permits air leaks, which may interrupt and redirect the flow of cooling air from internal components.
Electrostatic discharge (ESD) can damage equipment and impair electrical circuitry. ESD damage occurs when
electronic components are improperly handled and can result in complete or intermittent failures. Be sure to follow
ESD-prevention procedures when removing and replacing components to avoid these problems.
Wear an ESD-preventive wrist strap, ensuring that it makes good skin contact. If no wrist strap is available, ground

LEC-6041 User Manual
6
yourself by touching the metal part of the chassis.
Periodically check the resistance value of the antistatic strap, which should be between 1 and 10 megohms
(Mohms).
L’équipement électrique génère de la chaleur. La température ambiante peut ne pas être adéquate pour refroidir
l’équipement à une température de fonctionnement acceptable sans circulation adaptée. Vérifiez que votre site
propose une circulation d’air adéquate.
Vérifiez que le couvercle du châssis est bien fixé. La conception du châssis permet à l’air de refroidissement de bien
circuler. Un châssis ouvert laisse l’air s’échapper, ce qui peut interrompre et rediriger le flux d’air frais destiné aux
composants internes.
Les décharges électrostatiques (ESD) peuvent endommager l’équipement et gêner les circuits électriques. Des
dégâts d’ESD surviennent lorsque des composants électroniques sont mal manipulés et peuvent causer des pannes
totales ou intermittentes. Suivez les procédures de prévention d’ESD lors du retrait et du remplacement de
composants.
Portez un bracelet anti-ESD et veillez à ce qu’il soit bien au contact de la peau. Si aucun bracelet n’est disponible,
reliez votre corps àla terre en touchant la partie métallique du châssis.
Vérifiez régulièrement la valeur de résistance du bracelet antistatique, qui doit être comprise entre 1 et 10
mégohms (Mohms).
Mounting Installation Precautions
The following should be put into consideration for rack-mount or similar mounting installations:
Do not install and/or operate this unit in any place that flammable objects are stored or used in.
The installation of this product must be performed by trained specialists; otherwise, a non-specialist might create
the risk of the system’s falling to the ground or other damages.
Lanner Electronics Inc. shall not be held liable for any losses resulting from insufficient strength for supporting the
system or use of inappropriate installation components.
Elevated Operating Ambient - If installed in a closed or multi-unit rack assembly, the operating ambient
temperature of the rack environment may be greater than room ambient. Therefore, consideration should be given
to installing the equipment in an environment compatible with the maximum ambient temperature (Tma) specified
by the manufacturer.
Reduced Air Flow - Installation of the equipment in a rack should be such that the amount of airflow required for
safe operation of the equipment is not compromised.
Mechanical Loading - Mounting of the equipment in the rack should be such that a hazardous condition is not
achieved due to uneven mechanical loading.
Circuit Overloading - Consideration should be given to the connection of the equipment to the supply circuit and
the effect that overloading of the circuits might have on overcurrent protection and supply wiring. Appropriate
consideration of equipment nameplate ratings should be used when addressing this concern.
Reliable Grounding - Reliable grounding of rack mounted equipment should be maintained. Particular attention
should be given to supply connections other than direct connections to the branch circuit (e.g. use of power strips).
Instruction for the installation of the conductor to building earth by a skilled person.
Before turning on the device, ground the grounding cable of the equipment. Proper grounding (grounding) is very
important to protect the equipment against the harmful effects of external noise and to reduce the risk of
electrocution in the event of a lightning strike. To uninstall the equipment, disconnect the ground wire after turning
off the power. A ground wire (green-and-yellow) is required and the part connecting the conductor must be greater
than 6 mm2 or 8AWG.
Avant d’allumer l’appareil, reliez le câble de mise à la terre de l’équipement à la terre.
Une bonne mise à la terre (connexion à la terre) est très importante pour protéger l’équipement contre les effets
néfastes du bruit externe et réduire les risques d’électrocution en cas de foudre.
Pour désinstaller l’équipement, débranchez le câble de mise à la terre après avoir éteint l’appareil.
Un câble de mise à la terre est requis et la zone reliant les sections du conducteur doit faire plus de 6 mm2 ou 8
AWG.

LEC-6041 User Manual
7
Connect the grounding cable to the ground.
The protection device for the DC power source must provide 40A current.
This protection device must be connected to the power source before DC power.
Branchez le câble de mise à la terre àla terre.
L’appareil de protection pour la source d’alimentation CC doit fournir 40A
de courant.
Cet appareil de protection doit être branché à la source d’alimentation avant
l’alimentation CC.
Warning
This equipment must be grounded. The power cord for product should be connected to a socket-outlet with earthing
connection.
Product shall be used with Class 1 laser device modules.
Suitable for installation in Information Technology Rooms in accordance with Article 645 of the National Electrical
Code and NFPA 75.
The machine can only be used in a restricted access location and be installed and serviced by skilled person.
Class I Equipment. This equipment must be earthed. The power plug must be connected to a properly wired earth
ground socket outlet. An improperly wired socket outlet could place hazardous voltages on accessible metal parts.
Product shall be used with Class 1 laser device modules.
Avertissement
Cet équipement doit être mis àla terre. La fiche d'alimentation doit être connectée à une prise de terre
correctement câblée
Le produit doit être utilisé avec des modules de dispositifs laser de classe 1.
Peut être installé dans des salles de matériel de traitement de l'information conformément àl'article 645 du
National Electrical Code et àla NFPA 75.
Les matériels sont destinés à être installés dans des EMPLACEMENTS À ACCÈS RESTREINT.
Équipement de classe I. Ce matériel doit être relié à la terre. La fiche d’alimentation doit être raccordée à une prise
de terre correctement câblée. Une prise de courant mal câblée pourrait induire des tensions dangereuses sur des
parties métalliques accessibles.
Le produit doit être utilisé avec des modules de dispositifs laser de classe 1.
Important
1. Temperature Code (T-code) –T4.
2. LEC-6041B is in compliance with CID2 regulations.
3. LEC-6041B shall not be used at max 2000m altitude operation.
4. P-Fail Ports on Terminal Block cannot be used in CID2 Hazardous Location.
5. SFP Modules can be used are listed below:
Model FTLF1318P3xTLaaa (where x = W or B, a = 0-9,A-Z,dash,or blank), manufactured by Finisar Corp.

LEC-6041 User Manual
8
Package Content...........................................................................................................................9
Ordering Information ...................................................................................................................9
System Specifications.................................................................................................................10
Front Panel .................................................................................................................................11
Rear Panel...................................................................................................................................12
Motherboard Information..........................................................................................................13
Connecting Power ......................................................................................................................20
Installing Key Components.........................................................................................................21
Installing the Hard Disk...............................................................................................................23
Mounting the System on DIN Rail ..............................................................................................25
Wall-Mounting the System.........................................................................................................26
BIOS Setup..................................................................................................................................28
Warranty Policy ..........................................................................................................................68

LEC-6041 User Manual
9
Lanner’s LEC-6041, being the successor of LEC-6021, is designed to protect the communication in both IT
and OT domains. LEC-6041 series is empowered by Intel® Atom x7-E3950 or x5-E3930 for low power
consumption and high processing performance. As a rugged firewall deployed in challenging environments,
LEC-6041 comes with IEC 61850-3, IEEE 1613, and C1D2 certification, as well as 1.5 KV magnetic isolation
protections for LAN port and 15KV ESD Protection for I/O ports. The system can operate in a wide range of
operating temperature from -40°C to 70°C. All of the hardware designs assure that the security gateway
LEC-6041 will never have downtime while operating in hazardous surroundings such as OT environment.
Your package contains the following items:
1x LEC-6041 Fanless Box PC
1x Power Terminal Block & 4x Disk Screws
1x Ear Bracket & 4x Ear Bracket Screws
1x SATA Cable
1x Heat Sink
2x Thermal Pads & 2x Module Screws & 2x Heat Sink Screws
SKU No.
Main Features
LEC-6041A
IEC 61850-3 Wide Temperature ICS Cyber Security Gateway with Intel® Atom x5-E3930
processor
LEC-6041B
IEC 61850-3 Wide Temperature ICS Cyber Security Gateway with Intel® Atom x7-E3950
processor

LEC-6041 User Manual
10
Processor System
CPU
Intel Atom® x7-E3950 or x5-E3930
Frequency
Atom x5-E3930: 1.3 GHz, Atom x7-E3950: 1.6 GHz
Core Number
Atom x5-E3930: 2, Atom x7-E3950: 4
BIOS
AMI SPI Flash BIOS
Chipset
SoC
Fanless
Yes
System Memory
Technology
DDR3L, up to 1866 MHz
Max. Capacity
8 GB
Socket
1x 204-pin SODIMM
Graphic
Controller
Intel® HD 505 Graphics
Interface
1x HDMI
Ethernet
Controller
Intel® i210
Speed
RJ45: 10/100/1000Mbps, SFP: 1 Gbps
Interface
5x RJ45; 2x SFP
Bypass
1 pair Bypass
Magnetic Isolation Protection
1.5 KV built-in
Storage
Type
SATA
Installation
1x SATA connector with 2.5” drive bay
Type
mSATA
Installation
1x optional mSATA socket
Expansion
Mini-PCIe
1x mini-PCIe with 1 SIM card for 4G LTE module
(USB & PCIe signal) I/O
I/O
Serial Port
2x RS-232, DB9 male
USB Port
2x USB 3.0 type A
Power-On/Reset Button
Standard, HW Reset
LED
HDD, STA, PWR, L1~L5, F1~F2, C1~C2, LTE
Watchdog Timer
Watchdog timer 256 level time interval system reset,
software programmable
Power
Power Supply Voltage
Dual 20-54 Vdc
Connector
Phoenix contact 6-pin connector with lock
Environment
Operating Temperature
-40 ~ 70ºC
Storage Temperature
40 ~ 85ºC
Relative Humidity
5% ~ 95%, non-condensing
Mechanical
Dimension (WxHxD)
160 x 166 x 53.5 mm
Construction
Aluminum & SGCC
Weight
SKU A: 1.6 kg
Mounting
DIN rail or Wall mount
Driver Support
Microsoft Windows
Windows 10 64 bit
Linux
Linux Kernel 4.X
Certification
FCC/CE Class A, IEC61850-3, IEEE1613, C1D2

LEC-6041 User Manual
11
No.
Description
F1
HDMI Port
1x HDMI port
F2
SFP Port
2x 1G SFP port
F3
RJ45 Port
5x RJ45 port (LAN1 & LAN2 with LAN Bypass support)
F4
USB Port
2x USB 3.0 port
F5
LED Indicators
Each LAN dedicates 2x LEDs to represent Link and Speed (100/1000) and
fiber is only 1x LED.
Each COM dedicates 2x LED to represent TX & RX.
F6
COM Port
2x DB9 RS-232 with isolation
F7
Grounding Point
For grounding cable to connect with ground
F8
DC-in Jack
1x 6-pin terminal block for 2 sets of 20~54Vdc direct power input
F4
F5
F1
F6
Please refer to Appendix A: LED Indicator Explanations for descriptions of the LED Indicators.
F2
F3
F8
F7
HDD: Hard Disk Activity
STA: System Status
PWR: System Power
L1~L5: LAN Ports Activity
F1~F2: Fiber Ports Activity
C1~C2: COM Port Status
LTE: 4G/LTE Connection Status
LTE

LEC-6041 User Manual
12
No.
Description
R1
DIN Rail Bracket
R2
Reset Button
Standard, HW Reset
R1
2
R2

LEC-6041 User Manual
13
The block diagram indicates how data flows among components on the motherboard. Please refer to the
following figure for your motherboard’s layout design.

LEC-6041 User Manual
14
The motherboard layout shows the connectors and jumpers on the board. Refer to the following picture as
a reference of the pin assignments and the internal connectors.
PWR3
COM2
COM1
SATAPWR1
SIM1
MPCIE1
MSATA1
SATA1
JCMOS1
JSPI1
RST3
LPC1
JCMOS2

LEC-6041 User Manual
15
PWR3: Power Button
Jumper
Description
1-2
Power ON/OFF system
NC (Default)
Normal
RST3: HW/SW Reset Selection
JCMOS1/2: Clear CMOS
Jumper
Description
1-2 (Default)
Normal
2-3
Clear CMOS
COM1: Serial Port 1 Connector
Pin No.
Description
Pin No.
Description
1
NC
2
NC
3
COM1_R_RXD
4
NC
5
COM1_R_TXD
6
NC
7
NC
8
NC
9
COM1_2_GND
COM2: Serial Port 2 Connector
Pin No.
Description
Pin No.
Description
1
NC
2
NC
3
COM2_R_RXD
4
NC
5
COM2_R_TXD
6
NC
7
NC
8
NC
9
COM1_2_GND
Jumper
Description
1-2
Software reset
2-3 (Default)
Hardware reset

LEC-6041 User Manual
16
JSPI1: SPI ROM Connector (For RD debug)
Pin No.
Description
Pin No.
Description
1
HOLD#
2
NC
3
CS#
4
+1.8V
5
MISO
6
NC
7
NC
8
CLK
9
GND
10
MOSI
LPC1: LPC Connector (For RD debug)
Pin No.
Description
Pin No.
Description
1
CLK_24M_P80
2
L_AD1
3
PLTRST_P80_N
4
L_AD0
5
L_FRAME_N
6
P3V3S
7
L_AD3
8
GND
9
L_AD2
10
GND
SATAPWR1: SATA Power Connector
Pin No.
Description
1
V12_S
2
GND
3
GND
4
V5_S
SATA1: SATA Connector
Pin No.
Description
Pin No.
Description
1
GND
5
SATA_RXN1_C
2
SATA_TXP1_C
6
SATA_RXP1_C
3
SATA_TXN1_C
7
GND
4
GND

LEC-6041 User Manual
17
MSATA1: MSATA Connector
Pin No.
Description
Pin No.
Description
1
NC
2
V3P3_S
3
NC
4
GND
5
NC
6
NC
7
NC
8
NC
9
GND
10
NC
11
NC
12
NC
13
NC-
14
NC
15
GND
16
NC
Mechanical Key
17
NC
18
GND
19
NC
20
NC
21
GND
22
NC
23
SATA_RXP0_C
24
V3P3_S
25
SATA_RXN0_C
26
GND
27
GND
28
NC
29
GND
30
NC
31
SATA_TXN0_C
32
NC
33
SATA_TXP0_C
34
GND
35
GND
36
NC-
37
GND
38
NC
39
V3P3_S
40
GND
41
V3P3_S
42
NC
43
GND
44
NC
45
NC
46
NC
47
NC
48
NC
49
NC
50
GND
51
NC
52
V3P3_S

LEC-6041 User Manual
18
MPCIE1: MPCIE Connector
Pin No.
Description
Pin No.
Description
1
WAKE#
2
V3P3_S
3
NC
4
GND
5
NC
6
V1P5_S
7
CLKREQ#
8
UIM_PWR
9
GND
10
UIM_DATA
11
CLK_MPCIE_DN
12
UIM_CLK
13
CLK_MPCIE_DP
14
UIM_RESET
15
GND
16
NC
Mechanical Key
17
NC
18
GND
19
NC
20
W_DISABLE#
21
GND
22
PERST#
23
MPCIE_RXN
24
V3P3_S
25
MPCIE_RXP
26
GND
v27
GND
28
V1P5_S
29
GND
30
NC
31
MPCIE_TXN
32
NC
33
MPCIE_TXP
34
GND
35
GND
36
USB2_DN4
37
GND
38
USB2_DP4
39
V3P3_S
40
GND
41
V3P3_S
42
LED_WWAN#
43
GND
44
LED_WLAN#
45
NC
46
NC
47
NC
48
V1P5_S
49
NC
50
GND
51
NC
52
V3P3_S

LEC-6041 User Manual
19
SIM1: SIM Card Socket
Pin No.
Description
Pin No.
Description
C1
UIM_PWR
C5
GND
C2
UIM_RST#
C6
NC
C3
UIM_CLK
C7
UIM_DATA
Input Power connector: Dual power input
Pin No.
Description
1
DC2+
2
DC2-
3
ALARM1
4
ALARM2
5
DC1+
6
DC1-
Note
The failure of either power (DC1 or DC2) will cause both Alarm1 and Alarm2 to short-circuit.

LEC-6041 User Manual
20
Connect the device to a 20~54 VDC power source. The power source comes from the AC/DC Adapter
through a Phoenix contact. This power socket is specially designed to guard against a fault in power contact,
i.e., the reverse of the electrical polarity will not damage the system.
Note
The failure of either power (DC1 or DC2) will cause both Alarm1 and Alarm2 to short-circuit.
1x Phoenix Contact
Terminal Block
Table of contents
Other Lanner Gateway manuals
Popular Gateway manuals by other brands

SIEB & MEYER
SIEB & MEYER 0362157A manual

Juniper
Juniper SRX380 manual

Moxa Technologies
Moxa Technologies NPort 4511 Quick installation guide

Liebert
Liebert 232 user manual

Moxa Technologies
Moxa Technologies OnCell G3470A-LTE User manuals

enphase
enphase Envoy Communications Gateway Installation and operation manual