lassele LUCR27 User manual

Undercounter & Food Prep Tables
Installation & Operation Manual
Please read this manual completely before attempting to install or operate this equipment!
R512B-252
IMPORTANT SAFETY INSTRUCTIONS (SAVE THESE INSTRUCTIONS)
Visit us on the web at www.daeyeong.co.kr

◆
Specifications ......................................................................... 3
◆
Serial Number ....................................................................... 9
◆
Installation ............................................................................. 9
◆
Cleaning .............................................................................. 10
◆
Caution ................................................................................ 10
◆
Operation ............................................................................ 11
◆
Trouble-Shooting ................................................................. 12
◆
Installing Castors .................................................................. 13
CONTENTSCONTENTS
CONTENTSRECEIVING AND INSPECTING THE EQUIPMENT
2 3
Even though most equipment is shipped crated, care should be taken during unloading so
the equipment is not damaged while being moved into the building.
1. Visually inspect the exterior of the package and skid or container. Any damage should be
noted on the delivery slip and reported to seller immediately.
2. If damaged, open and inspect the contents with the carrier.
3. WITHIN 48 HOURS OF RECEIPT : In the event that the exterior is not damaged, yet upon
opening, there is concealed damage to the equipment, notify seller immediately.
4. Be certain to check the compressor compartment housing and visually inspect the
refrigeration package. Be sure lines are secure and base is still intact.
5. Retain all crating material until an inspection has been made or waived.

◆
Specifications and Designs are subject to change without notice.
◆
The rating plate (including Serial No.) is located on the upper left side of the cabinet interior.
2 3
SPECIFICATIONS
Product Undercounter Refrigerator
Model
LUCR27/27T LUCR36/36T LUCR48/48T LUCR60/60T LUCR72/72T
Capacity(Liter) 200 270 372 474 572
Exterior Dimensions
(Including 4" Casters)
[mm]
W 700 923 1227 1533 1839
D 762 762 762 762 762
H 912 912 912 912 912
Net Weight (kg)
61 74 87 103 120
Type of refrigeration system
Indirect cooling (Fan blowing)
Control Thermostat
Number of Shelves 2 4 4 4 6
Number of doors 1 2 2 2 3
Rated Voltage 220V, 50Hz / 60Hz
Amps 2.0 2.0 2.0 2.5 2.5
Compressor(HP) 1/5 1/5 1/5 1/3 1/3
Refrigerant (R-134a) (g) 110 130 140 150 150
Range of temperature 0
ºC
~ 5
ºC
(33
ºF
~ 41
ºF)
Temperature indicator 70mm X 23.5mm X 34.2mm
-50
ºC
~ 99
ºC
785
127
* "T" =Temperature indicator option

4 5
◆
Specifications and Designs are subject to change without notice.
◆
The name plate (including Serial No.) is located on the upper left side of the cabinet interior.
SPECIFICATIONS
Product Undercounter Drawer Refrigerator
Model
LUCR27-D2 LUCR48-D4 LUCR60-D4 LUCR72-D6
Capacity(Liter)
200 372 474 572
Exterior Dimensions
(Including 4" Casters)
[mm]
W
700 1227 1533 1839
D
762 762 762 762
H
912 912 912 912
Net Weight (kg)
66 108 126 150
Type of refrigeration system
Indirect cooling (Fan blowing)
Control
Thermostat
Number of Drawers
2 4 4 6
Rated Voltage
220V/ 50Hz
Amps
2.0 2.0 2.5 2.5
Compressor(HP)
1/5 1/5 1/3 1/3
R-134a Refrigerant (g)
110 140 150 150
Range of Temperature
0
ºC
~ 5
ºC
(33
ºF
~ 41
ºF)
785
127

4 5
◆
Specifications and Designs are subject to change without notice.
◆
The rating plate (including Serial No.) is located on the upper left side of the cabinet interior.
SPECIFICATIONS
785
127
Product Undercounter Freezer
Model
LUCF27/27T LUCF36/36T LUCF48/48T LUCF60/60T LUCF72/72T
Capacity(Liter)
200 270 372 474 572
Exterior Dimensions
(Including 4" Casters)
[mm]
W
700 923 1227 1533 1839
D
762 762 762 762 762
H
912 912 912 912 912
Net Weight (kg)
64 78 91 108 124
Type of refrigeration system
Indirect cooling (Fan blowing)
Control
Thermostat
Number of Shelves
24446
Number of doors
12223
Rated Voltage
220V, 50Hz / 60Hz
Amps
2.5 4.0 4.0 4.0 4.0
Compressor(HP)
1/3 1/2 1/2 1/2 1/2
Refrigerant (g)
150
(R-134a)
150
(R-404A)
160
(R-404A)
350
(R-404A)
400
(R-404A)
Range of temperature -23ºC~ -15ºC (-10ºF - 5ºF)
Temperature indicator 70mm X 23.5mm X 34.2mm
-50
ºC
~ 99
ºC
* "T" =Temperature indicator option

6
◆
Specifications and Designs are subject to change without notice.
◆
The rating plate (including Serial No.) is located on the upper left side of the cabinet interior.
SPECIFICATIONS
Product Salad Table
Model
LST27/27T LST36/36T LST48/48T LST60/60T LST72/72T
Capacity(Liter)
200 270 372 474 572
Exterior Dimensions
(Including 4" Casters)
[mm]
W
700 923 1227 1533 1839
D
762 762 762 762 762
H
1082 1082 1082 1082 1082
Net Weight (kg)
67 82 100 11 2 129
Type of refrigeration system
Indirect cooling (Fan blowing)
Control
Thermostat
Number of Shelves
1 2 2 2 3
Number of doors
1 2 2 2 3
4" Deep PE fans
810 12 16 18
Cutting board(mm)
240 X 696 240 X 920 240 X 1224 240 X 1530 240 X 1835
Rated Voltage
220V, 50Hz / 60Hz
Amps
2.0 2.0 2.0 2.5 2.5
Compressor(HP)
1/5 1/5 1/5 1/3 1/3
Refrigerant (R-134a) (g)
120 140 150 160 180
Range of temperature
0
ºC ~ 5ºC
(33
ºF
~ 41
ºF)
Temperature indicator 70mm X 23.5mm X 34.2mm,
-50
ºC
~ 99
ºC
785
1236
127
* "T" =Temperature indicator option

7
◆
Specifications and Designs are subject to change without notice.
◆
The name plate (including Serial No.) is located on the upper left side of the cabinet interior.
SPECIFICATIONS
Product Salad DrawerTable
Model
LST27-D2 LST48-D4 LST60-D4 LST72-D6
Capacity(Liter)
200 372 474 572
Exterior Dimensions
(Including 4" Casters)
[mm]
W
700 1227 1533 1839
D
762 762 762 762
H
1082 1082 1082 1082
Net Weight (kg)
72 121 135 160
Type of refrigeration system
Indirect cooling (Fan blowing)
Control
Thermostat
Number of Drawers
2 4 4 6
Rated Voltage
220V/ 50Hz
Amps
2.0 2.5 2.5 2.5
Compressor(HP)
1/5 1/5 1/3 1/3
R-134a Refrigerant (g)
120 150 160 180
Range ofTemperature
0
ºC
~ 5
ºC
(33
ºF
~ 41
ºF)
1236
785
127

8
◆
Specifications and Designs are subject to change without notice.
◆
The rating plate (including Serial No.) is located on the upper left side of the cabinet interior.
SPECIFICATIONS
Product Mega TopTable
Model
LMT27/27T LMT36/36T LMT48/48T LMT60/60T LMT72/72T
Capacity(Liter)
200 270 372 474 572
Exterior Dimensions
(Including 4" Casters)
[mm]
W
700 923 1227 1533 1839
D
841 (Including cutting board 901)
H
1122 1122 1122 1122 1122
Net Weight (kg)
76 92 110 123 141
Type of refrigeration system
Indirect cooling (Fan blowing)
Control
Thermostat
Number of Shelves
1 2 2 2 3
Number of doors
1 2 2 2 3
4" Deep PE fans
12 15 18 24 27
Cutting board(mm)
240 X 696 240 X 920 240 X 1224 240 X 1530 240 X 1835
Rated voltage
220V, 50Hz / 60Hz
Amps
2.0 2.0 2.0 2.5 2.5
Compressor(HP)
1/5 1/5 1/5 1/3 1/3
Refrigerant (R-134a) (g)
120 140 150 160 180
Range of Temperature
0
ºC
~ 5
ºC
(33
ºF
~ 41
ºF)
Temperature indicator 70mm X 23.5mm X 34.2mm
-50
ºC
~ 99
ºC
785
1359
948
127
* "T" =Temperature indicator option

9
※Reference
•If a door for left hand is necessary, please contact the sales representative in your area.
•A set of door & Door hinge can be purchased separately to convert between Right Hand and Left Hand side
INSTALLATION
1. GOOD AIR CIRCULATION - Inside and Outside the Unit
- Make sure to avoid any object which will interrupt or block the air flow inside the unit.
- Make sure to leave enough space toward the interior rear wall to ensure good air circulation
- Make sure to keep 7 inches space at the rear and sides of the unit.
2. PLACE ON SOLID SURFACE
- A fully loaded unit can weigh over 1,000 pounds.
3. DO NOT PLACE NEAR HEAT SOURCE
- Make sure to avoid hot corner or any location near stove, oven, or other heat source.
- High ambient temperature will cause cooling efficiency to drop.
4. INDOOR USAGE ONLY
-This equipment is intended for indoor use only.
5. STABILIZING
- Make sure the unit is installed on a solid surface with the front wheels locked while in use.
6. LEVELING
- Make sure that the unit is leveled well from front to back and side to side.
7. Unit should be connected to a dedicated electrical circuit.
- Do not use extension cords.
- Plug the unit to a dedicated electrical circuit & adequate capacity.
8. Install plastic condensate pan in the bottom of the unit.
- Make sure pads are installed upwards and drain hose is in pan.
9. Install the unit in a place where the air circulation is good.
- Maintain enough spaces around the unit since air
to ensure the best cooling performance
- If air circulation is obstructed, then cooling
performance will drop, thus consuming more electricity as a result. over 50 cm
over 50 cm
Serial number
The serial number is located on the rating label which is on the left interior wall.
Please retain the unit's serial number for service purposes.

10
1. CLEANINGTHE INTERIOR AND EXTERIOR
-The interior and exterior of the unit can be cleaned using warm water with soap.
- Do not use an abrasive cleaner because it will scratch the surface.
2. CLEANINGTHE GASKET
-The door gasket should be cleaned frequently to maintain proper sealing.
Use warm water and a mild soap.
3. CLEANINGTHE EVAPORATOR
-The condenser coil must be cleaned a minimum of every 90 days or more frequently if there is a large
accumulation of dust.
-Clean the condenser coil with a soft brush or a vacuum. Brush only in the direction of the fins.
-If using compressed air, always blow the air from top to botton and never from left to right to avoid bending
the fins.
-If there is a buildup of grease or you cannot remove the dust, call for service.This is not a warranty issue.
4. CHECK AFTER CLEANING
- Check the unit again for safety.
- Check if the unit is operating properly.
5. CONDENSER CLEANING
①
Disconnect power to unit
②
Take off rear cover at the bottom by removing screws.
③
Clean off accumulated dirt from condensing coil and fan blades with a soft brush.
Make sure to brush in the direction of the fins and not across them to avoid any damage.
④
After brushing condenser coil, vacuum dirt from coil and interior floor.
⑤
Reinstall rear cover onto unit.Tighten all screws.
⑥
Connect unit to power and check to see if compressor is running.
WARNING -To reduce the risk of electric shock, unplug before
cleaning or servicing.
CLEANING
1. POWER CORD
- Make sure the power cord is connected to the proper voltage.
- Compressor warranties are void if compressor burns out due to improper voltage.
- A protected circuit of the correct voltage and amperage must be used for connection of the power cord.
-Turn 'off ' the power switch before disconnecting the power cord whenever performing
maintenance functions or cleaning the refrigerated cabinet.
- If the power cord of the unit is damaged, it should be replaced by an authorized service agent.
2. RE-STARTING
- If disconnected, wait 5 minutes before re-starting.
Caution
Condensing coil & fan blades

11
Operation
1.The temperature controller(thermostat) is located on the upper left of the back side
of the cabinet interior.
2.The controller has been preset to "NORMAL" at the factory.
3. Set the control-knob toward "COOL" for higher temperature and "COLD" for lower
temperature.
4.The thermostat controls compressor's ON/OFF by sensing inside temperatures of
cabinet.
5. LUCR, LST, LMT Series : Off-cycle defrost
LUCF Series : Heating defrost
6. When turning it off, use the POWER SWITCH on top.
Operation
POWER SWITCH

12 13
Trouble-Shooting
Problem
Possible Cause Action
Compressor not working
Power connection failure Check Power Cord and
plug it in
Power switch is in off position Change it on position
The unit does not
refrigerate well
Temperature set point is
too high
Correct temperature set
point
The door is opened
too frequently
-
Loading of too much warm
or moist product
-
Not enough ventilation
Move the unit in a well
Ventilated place with at
least 7
Inches of clearance on all
sides
Condenser is clogged Clean it
Condensation
on cabinet exterior
High humidity can cause
surface condensation. Also,
make sure that the door
seals are clean and in good
condition.
Wipe with cloth
◆
A water-flowing sound can be heard when the unit is operating.
This is the sound of refrigerant flowing.

12 13
Installing Casters
1. Remove the outer packing.
2. Install the castors as illustrated.
3.
Maker sure that the castors with brakes are installed at the front of the unit.

14
MEMO

15
MEMO

Manufacturer : DAEYEONG E&B
ANSAN-SI, GYEONGGI-DO, REPUBLIC OF KOREA
TEL.+82-31-491-1091 FAX. +82-31-491-0325
www.daeyeong.co.kr
This manual suits for next models