LAUMAS W200 Series User manual

22
22
INDICATORI DI PESO
WEIGHT INDICATORS
W200
W200
Weight Indicator in DIN box (96 x 96 x 130 mm, drilling template 91x91mm)
for panel mounting. IP54 front panel protection. Six-digit semialphanumeric
display (14 mm h), 7 segment; 8 alarm LED. Five-key membrane keyboard.
Real-time clock with buffer battery.
Models 6-14 PRODUCTS include 8-relay modules.
- IP67 waterproof polycarbonate box version: Dimensions 180 x 130 x 77
mm. Four fixing holes Ø 4 mm (centre distance 163 x 113 mm).
- IP64 waterproof polycarbonate box version: Dimensions 180 x 130 x 77
mm. Four fixing holes Ø 4 mm (centre distance 163 x 113 mm); provided with
an external selector switch to select the formula (EC option); four PG9 cable
glands; Sart and Stop buttons.
Two serial ports (RS232 and RS485) for connection to:
- PC/PLC up to 32 instruments (max 99 with line repeaters) by ASCII Laumas
protocol (compatible with W60000 only for W200BASE) or ModBus RTU.
- Remote display.
- Printer.
Optional integrated output: Profibus DP, DeviceNet, CANopen, Profinet IO,
Ethernet/IP, Ethernet TCP/IP ( connectable to your smartphone, tablet,
etc.. via web ), Modbus/TCP.
THEORETICAL CALIBRATION is performed via the keyboard.
REAL CALIBRATION with linearization up to 5 points.
Indicatore di peso in custodia a norme DIN (96 x 96 x 130 mm, foratura
91 x 91 mm) per montaggio a fronte quadro. Grado di protezione del
frontale IP54. Display semialfanumerico a 6 cifre da 14mm, a 7 segmenti;
8 LED di segnalazione. Tastiera 5 tasti a membrana con buzzer. Orologio/
Calendario con batteria tampone.
I modelli 6 -14 PROD. vengono forniti completi di moduli 8-relè.
- Versione in cassetta stagna IP67 in policarbonato: Dimens.
180x130x77mm. Quattro fori di fissaggio Ø4mm (interasse fori 163x113mm).
- Versione in cassetta stagna IP64 in policarbonato: Dimens.
180x130x77 mm. Quattro fori di fissaggio Ø 4 mm (interasse fori 163x113
mm); provvista di commutatore esterno per selezione formule (opzione
EC), quattro pressacavi PG9, pulsanti di Start e Stop.
Due porte seriali (RS232 e RS485) per collegamento a:
- PC/PLC sino a 32 strumenti (max 99 con ripetitori di linea) mediante
protocollo ASCII Laumas (compatibile con W60000, solo per
W200BASE) o ModBus R.T.U.
- Ripetitore di peso.
- Stampante.
Opzionali uscita integrata Profibus DP, DeviceNet, CANopen, Profinet
IO, Ethernet/IP, Ethernet TCP/IP ( collegabile a smartphone, tablet,
etc. via web ), Modbus/TCP.
CALIBRAZIONE TEORICA da tastiera.
CALIBRAZIONE REALE con linearizzazione fino a 5 punti.
- Convertitore A/D 24 bit (16000000 punti) 4800Hz
- Divisioni di lettura 999999
- Frequenza di acquisizione 300 Hz
- A/D Converter 24bit (16000000 points) 4800Hz
- Display range 999999
- Conversion rate 300 Hz
CE -
M
APPROVABLE
10000 divisions
III
0.2 μV/VSI
Opzione a richiesta:
Memorizzazione dati
su chiavetta USB
On request:
Data storage
on Pen
Drive USB
CARATTERISTICHE TECNICHE
CARATTERISTICHE TECNICHE
TECHNICAL FEATURES
TECHNICAL FEATURES
ALIMENTAZIONE e POTENZA ASSORBITA
N° CELLE DI CARICO IN PARALLELO E ALIMENTAZIONE
LINEARITÀ /LINEARITÀ USCITA ANALOGICA
DERIVA TERMICA / DERIVA TERMICA ANALOGICA
CONVERTITORE A/D
DIVISIONI MAX (con campo di misura +/-10mV = sens. 2mV/V)
CAMPO DI MISURA MAX
MAX SENSIBILITÀ CELLE DI CARICO IMPIEGABILI
MAX CONVERSIONI AL SECONDO
CAMPO VISUALIZZABILE
N. DECIMALI / RISOLUZIONE LETTURA
FILTRO DIGITALE / LETTURE AL SECONDO
USCITE LOGICHE A RELÈ
INGRESSI LOGICI
PORTE SERIALI
BAUD RATE
UMIDITÀ (non condensante)
TEMPERATURA DI STOCCAGGIO
TEMPERATURA DI LAVORO
TEMPERATURA DI LAVORO (APPROVATO CE-M)
12 - 24VDC +/-10% ; 5W
max 8 ( 350 ohm ) ; 5VDC / 120 mA
< 0.01% Full Scale ; < 0.01% F.S.
< 0.0005 % F.S./°C < 0.003 % F.S./°C
24 bit (16000000 points) 4.8kHz
± 999999
± 39 mV
± 7 mV/V
300 conversions/sec.
- 999999 ; + 999999
0 - 4 / x 1 x 2 x 5 x 10 x 20 x 50 x 100
0.012 - 7 sec / 5 - 300 Hz
N. 5 - max 115 VAC ; 150 mA
(N. 4 - Analog output versions)
N. 3 - optoisolated 5 - 24 VDC PNP
(N. 2 - Analog output versions)
RS232, RS485
2400, 4800, 9600, 19200, 38400, 115200
85%
-30°C + 80°C
-20°C + 60°C
-10°C + 40°C
POWER SUPPLY and CONSUMPTION
NUMBER OF LOAD CELLS IN PARALLEL and SUPPLY
LINEARITY/ LINEARITY OF THE ANALOG OUTPUT
THERMAL DRIFT / THERMAL DRIFT OF THE ANALOG OUT.
A/D CONVERTER
MAX DIVISIONS (with measure range: +/- 10mV =2mV/V)
MEASURE RANGE
MAX LOAD CELL’S SENSITIVITY
MAX CONVERSIONS PER SECOND
DISPLAY RANGE
DECIMALS / DISPLAY INCREMENTS
DIGITAL FILTER / CONVERSION RATE
LOGIC OUTPUTS (relays)
LOGIC INPUTS
SERIAL PORTS
BAUD RATE
HUMIDITY (condensate free)
STORAGE TEMPERATURE
WORKING TEMPERATURE
WORKING TEMPERATURE (CE-M APPROVED)
IP67 waterproof box version IP64 waterproof box version
GOST R
Russian
Standards
A richiesta
on request
- Convertitore A/D 24 bit (16000000 punti) 4800Hz
W200 BASE
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
W200
BASE
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
W200 ANA
. . . . . . . . . . . . . . . . . . . Uscita analogica . . . . . . . . . . . .
W200
ANA
. . . . . . . . . . . . . . . . Analog Output . . . . . . . . . . . . .
W200 CARICO
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
W200
LOAD
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
W200 SCARICO
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
W200
UNLOAD
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
W200 3 PRODOTTI
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
W200
3 PRODUCTS
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
W200 6 PRODOTTI
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
W200
6 PRODUCTS
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
W200 14 PRODOTTI
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
W200
14 PRODUCTS
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
W200 MULTI (multiprogram)
6 modalità di funzionamento selezionabili a cura del CLIENTE: BASE,
CARICO,SCARICO,3/6/14PRODOTTI(moduli8-releesclusi).SixdifferentoperatingmodesSELECTABLE
BY CUSTOMER: BASE, LOAD, UNLOAD, 3/6/14 PRODUCTS (8-relay modules NOT included) . . . . . . . . . . . . . . . . .

23
W200
W200
INDICATORI DI PESO
WEIGHT INDICATORS
23
23
OPZIONI A RICHIESTA : OPTIONS ON REQUEST :
(5)
- Alimentazione 230 Vca (opzione esclusa per versioni IP64-IP67)
. . .
(5)
- Power supply 230 VAC (not available for IP64-IP67 versions)
(5)
- Alimentazione 115 Vca (opzione esclusa per versioni IP64-IP67)
. . .
(5)
- Power supply 115 VAC (not available for IP64-IP67 versions)
- Versione stagna in CASSETTA IP67 in policarbonato
. . . . . . . . . . . . . . .
- IP67 waterproof polycarbonate box version
. . . . . . . . . . . . . . . . . .
- Versione IP67 ATEX II 3GD (zona 2-22)
. . . . . . . . . . . . . . . . . . . . . . .
- IP67 ATEX version II 3GD (zone 2-22)
. . . . . . . . . . . . . . .
(1)
- Versione stagna in CASSETTA IP64 in policarbonato con commutatore
EC e pulsanti START e STOP
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
(1)
- IP64 waterproof polycarbonate box version with EC commutator
and START/STOP buttons . . . . . . . . . . . . . . . . . . . . . . . . . . . .
- Verificazione prima in abbinamento a ns modulo di pesatura
M
. .
- Initial verification (Legal Metrology)
M
. . . . . . . . . . . . . . . . . . .
-
OPZWALIBI:
Memoria fiscale
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
- OPZWALIBI: Alibi memory
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
-
E: Selezione delle prime 12 formule/setpoint da contatti esterni
. . . . .
- E: 12 formulas/setpoint selection from external contacts
. . . . . .
-
EC: Selezione prime 12 formule/setpoint da commutatore esterno
. .
- EC: 12 formulas/setpoint selection from external selector switch
(1)
- USCITAANALOGICA
(4)
16 bit optoisolata: 0-20mA; 4-20mA (max
300 ohm); 0-10V; 0-5V; ±10V; ±5V (min. 10 kohm)
. . . . . . . . . . . . . . . . . .
(1)
- 16 bit optoisolated ANALOG OUTPUT
(4)
: 0-20mA; 4-20mA
(max 300 ohm); 0-10V; 0-5V; ±10V; ±5V (min. 10 kohm)
. . . . .
-
OPZW96X96IP65:
Guarnizione per frontale stagno IP65
. . . . . . . . . . .
- OPZW96X96IP65: IP65 panel sealing gasket
. . . . . . . . . . . . . . . .
-
OPZWING010:
Lettura peso da ingresso 0-10Vcc (15kΩ)
. . . . . . . . . .
- OPZWING010:
Weight reading from 0-10Vcc (15kΩ) input
. . . .
-
OPZWING420:
Lettura peso da ingresso 4-20mA (120Ω)
. . . . . . . . . . .
- OPZWING420:
Weight reading from 4-20mA (120Ω) input
. . . . .
-
OPZWINGSER:
Lettura peso da ingresso seriale di 1 strumento
. . .
- OPZWINGSER:
Weight reading via serial input of 1 instrum.
-
OPZW1RADIO:
Ricetrasmissione radio
. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
- OPZW1RADIO: Two-way radio transmission
. . . . . . . . . . . . . . . .
-
OPZW1RS485:
Porta RS485 aggiuntiva
. . . . . . . . . . . . . . . . . . . . . . . . . . . .
- OPZW1RS485: RS485 additional port
. . . . . . . . . . . . . . . . . . . .
(3)
-
OPZWSCARP:
Scarichi parziali a fine ciclo
. . . . . . . . . . . . . . . . . . . . . . . . .
(3)
- OPZWSCARP: End cycle partial unloadings
. . . . . . . . . . . . . . . . .
(3)
-
OPZWSCARI: Scarichi intermedi tra un prodotto e il successivo
. . . .
(3)
-OPZWSCARI: Unloadings between a product and the next
. . .
(3)
-
OPZWSCA3614:
Scarico di più prodotti dalla stessa bilancia
. . . . . . .
(3)
- OPZWSCA3614:
Unloading of more products from same scale
-
OPZWDATIPC:
Trasferimento dei dati via seriale a PC
. . . . . . . . . . . . .
- OPZWDATIPC: Data transfer via serial port to PC
. . . . . . . . . .
-
OPZWUSBW200:
Memorizzazione dati su chiavetta USB (inclusa)
mediante porta USB incorporata
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
- OPZWUSBW200:
Storage of data on USB Pen Drive (included)
by USB port built-in . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
-
OPZWCONUSBIP68:
Cavo prolunga USB IP68 da pannello
. . . . . . .
- OPZWCONUSBIP68: IP68 USB panel extension cable
. . . . .
(3)
-
OPZWFORPERC:
Impostazione delle formule in percentuale
. . . . . .
(3)
- OPZWFORPERC: Formula setting in percentage
. . . . . . . . . . . .
(1)
-
OPZWQMC:
Impostazione di una quantità da dosare maggiore della
capacità della bilancia con calcolo automatico dei cicli dosaggio
. . . .
(1)
- OPZWQMC:Possibility of setting a quantity to be batched greater
than the scale capacity with automatic calculation of cycles
. .
-
RELE5M: Modulo relé 2A (non disponibile per 6/14 PRODOTTI)
. . .
- RELE5M: 2A relay module (not available for 6/14 PRODUCTS)
(2)
-
RELE6PROD24V
:Modulo 8-relé per 6/14 Prodotti ( 12-24 Vcc )
. . . . .
(2)
- RELE6PROD24V: 8-Relay module for 6/14 Prod. (12-24VDC)
(2)
-
RELE6PROD115V: Modulo 8-relé per 6/14 Prodotti ( 115 Vca )
. . . .
(2)
- RELE6PROD115V: 8-Relay module for 6/14 Prod. (115VAC)
(2)
-
RELE6PROD230V: Modulo 8-relé per 6/14 Prodotti ( 230 Vca )
. . . .
(2)
- RELE6PROD230V: 8-Relay module for 6/14 Prod. (230VAC)
(2)
-
RELE14PROD: Modulo 8-relé aggiuntivo per 14 Prodotti
. . . . . . . . . .
(2)
- RELE14PROD: Additional 8-relay module for 14 Prod.
. . . . . .
(1)
-
OPZWLAUMAN:
Dosaggio manuale guidato con ripetitori di peso
(1)
-
OPZWLAUMAN:
Assisted manual batching with remote displays
-
OPZW1CA:
Protocollo CANopen
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
-OPZW1CA: CANopen protocol . . . . . . . . . . . . . . . . . . . . . . . .
-
OPZW1DE:
Protocollo DeviceNet
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
-OPZW1DE: DeviceNet protocol. . . . . . . . . . . . . . . . . . . . . . . .
-
OPZW1ETIPW200:
Protocollo Ethernet/IP (porta ethernet)
. . . . . . . . .
- OPZW1ETIPW200: Ethernet/IP protocol (ethernet port). . . . .
-
OPZW1ETTCPW200:
Protocollo Ethernet TCP/IP (porta ethernet)
.
-OPZW1ETTCPW200:Ethernet TCP/IP protocol (ethernet port)
-
OPZW1MBTCPW200:
Protocollo Modbus/TCP (porta ethernet)
. . . .
- OPZW1MBTCPW200: Modbus/TCP protocol (ethernet port)
-
OPZW1PNETIOW200:
Protocollo Profinet IO (porta ethernet)
. . . . . .
-OPZW1PNETIOW200: Profinet IO protocol (ethernet port) . .
-
OPZWCONETHEIP68:
Cavo prolunga ethernet IP68 da pannello
. .
-OPZWCONETHEIP68: IP68 ethernet panel extension cable
-
OPZW1PR:
Protocollo Profibus DP
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
-OPZW1PR: Profibus DP protocol . . . . . . . . . . . . . . . . . . . . . .
-
OPZW1LOADCELL2:
ingresso per collegare una seconda cella di
carico (richiedere OFFERTA)
- OPZW1LOADCELL2: Input for connecting a second load
cell (Ask for an OFFER)
(1) non
disponibili per modelli BASE e ANA
(1)
not available for model BASE and ANA
(2) disponibili
per modello MULTI
(2)
available for model MULTI
(3) disponibili
per modello 3-6-14 PRODOTTI
(3)
available for model 3-6-14 PRODUCTS
(4) se presente l’uscita analogica non sono disponibili l’ingresso sul
morsetto 14 e l’uscita sul morsetto 15 (vedi schemi elettrici); inoltre
non sono disponibili le opzioni E / EC
(4)
if analog output is present: input on terminal 14 and output on
terminal 15 are not available (see wiring diagrams); E / EC
options not available
(5) non compatibile con: OPZWUSBW200 - OPZW1ETIPW200 -
OPZW1ETTCPW200 - OPZW1MBTCPW200 - OPZW1PNETIOW200 (5)
not compatible with: OPZWUSBW200 - OPZW1ETIPW200 -
OPZW1ETTCPW200 - OPZW1MBTCPW200 - OPZW1PNETIOW200
) è possibile scegliere una sola opzione tra quelle contrassegnate
dall’asterisco. Opzioni non disponibili per modello ANA
)
you can only choose one option from those marked with asterisk.
Options not available for model ANA

24
24
W200
W200
Cavo prolunga USB IP68 maschio/femmina da pannello, connettore
a tenuta stagna, lunghezza 50 cm, inclusi tappo (a) e fodera (b).
IP68 USB extension cable (male/female) for panel mounting,
sealed connector, 50 cm long cable, sealing cap (a) and cover
(b) included.
OPZWCONUSBIP68
a) b)
RELE6PROD -24V/-115V /-230V
Modulo esterno 8-relé per gestire da 1 a 6 prodotti; 8 relé
da max 115Vac/2A.
Modulo già incluso nei modelli 6/14 PRODOTTI.
External 8-relay module to manage from 1 to 6 products;
8 relays up to max 115VAC/2A.
Module already included for models 6/14 PRODUCTS.
RELE14PROD
Modulo esterno 8-relè per gestire da 7 a 14 prod. in aggiunta
al modulo RELE6PROD; 8 relé da max. 115Vac/2A. Modulo
già incluso nel modello 14 PRODOTTI.
External 8-relay module to manage from 7 to 14 product;
to be added to RELE6PROD module; 8 relays up to max.
115VAC/2A. Module already included for model 14
PRODUCTS.
RELE5M
Modulo 5-relé esterno per aumentare
la portata dei contatti di scambio a
2A/115Vac.
Opzione non disponibile per modelli
6/14 PRODOTTI.
External 5-relay module to to increase the
capacity of SPDT contacts to 2A/115Vac.
Option not available for models 6/14
PRODUCTS.
OPZW96X96IP65
Guarnizione per frontale stagno IP65.
IP65 panel sealing gasket.
EC
Per Carico, Scarico, 3/6/14 prodotti: Commutatore
esterno per la selezione delle prime 12 formule.
Per Base e Uscita analog.: Commutatore per selezione
12 gruppi da 5 setpoint.
For Load, Unload, 3/6/14 Products: Selector switch for
12 formulas selection.
For Base and Analog output: Selector switch for 12
groups selection by 5 setpoint.
Dosaggio manuale con ripetitori di peso (esempio
di applicazione con 3 ripetitori affiancati).
Questa opzione consente di visualizzare su
differenti ripetitori, collegati in parallelo allo
strumento tramite porta seriale RS485, le
seguenti informazioni di dosaggio: numero della
formula e del prodotto, rimanente quantità da
dosare, peso lordo.
Manual batching with remote displays (example of
application with 3 remote display side by side).
This option allows to display on different remote
displays, connected in parallel to the instrument
via RS485 serial port, the following batching
information: formula and product number,
instrument status, the remaining quantity to be
batched, gross weight.
OPZ
WLAUMAN
OPZW1ETIPW200 - OPZW1ETTCPW200
OPZW1MBTCPW200 - OPZW1PNETIOW200
Porta Ethernet per i seguenti protocolli opzionali:
Ethernet/IP, Ethernet TPC/IP, Modbus/TCP,
Profinet IO.
Ethernet port for the following optional protocols:
Ethernet/IP, Ethernet TPC/IP, Modbus/TCP,
Profinet IO.
Memorizzazione dei dati (pesate effettuate, dosaggi, allarmi) su
chiavetta USB. Tali dati potranno essere importati ed elaborati sul PC
mediante il software PROG-DB incluso nella fornitura. È possibile
effettuare il salvataggio dei dati in continuo o in manuale:
- Continuo: la chiavetta deve essere sempre inserita nella porta
USB dello strumento;
- Manuale: l’operatore inserisce la chiavetta USB nello strumento
solo quando desidera scaricare i dati dallo strumento.
Data storage (weighed values, batchings, alarms) on Pen Drive
USB. These data can be imported and processed on PC using the
PROG-DB software included in the supply.
Data can be saved in two different ways, continuous or manual:
- Continuous: USB pen must always be inserted during the
instrument operation.
- Manual: the operator inserts the pen into the instrument only
when needs to copy the data from the instrument.
OPZWUSBW200
inclusa
included
Trasferimento dei dati (pesate effettuate, dati
di dosaggio, allarmi) dallo strumento ad un
PC, tramite porta seriale RS232 (direttamente)
o RS485 (mediante convertitore). Tali dati
potranno poi essere importati ed elaborati sul
PC mediante il software PROG-DB incluso
nella fornitura. L’utilizzo di questa opzione è
da consigliare quando lo strumento è sempre
collegato al PC.
Data transfer (weighed values, batchings,
alarms) from the weight indicator to the PC
via RS232 serial port (directly) o RS485
(by converter). These data can be imported
and processed on PC using the PROG-DB
software included in the supply.
We suggest to use this option when the
indicator is always connected to the PC.
OPZWDATIPC
INDICATORI DI PESO
WEIGHT INDICATORS
Cavo prolunga ETHERNET IP68 maschio/
femmina da pannello, connettore a tenuta
stagna, lughezza 50 cm, incluso tappo (a).
IP68 ETHERNET extension cable (male/
female) for panel mounting, sealed connector,
50 cm long cable, sealing cap (a) included.
OPZWCONETHEIP68
a)

25
25
W200
W200
BASE / USCITA ANALOG.
BASE / USCITA ANALOG.
Funzioni principali
- 5 setpoint (4 setpoint nel modello ANA) configurabili normalmente aperti o
normalmente chiusi. É possibile decidere se lo scatto dei singoli setpoint
debba avvenire per il peso lordo o per il peso netto, solo per valori di peso
positivi o per valori di peso negativi e positivi.
- Programmazione del valore di isteresi per ogni setpoint.
- Selezione 12 gruppi da 5 setpoint da commutatore o contatti (Opz. EC/E).
- Visualizzazione del picco massimo raggiunto mediante la chiusura del relativo
contatto d’ingresso.
- Funzione netto/lordo da tastiera o contatto esterno.
- Impostazione manuale del valore di zero quando non è possibile azzerare
il peso.
- Funzione Autozero all’accensione.
- Funzione inseguimento di zero.
- Stampa del peso da tastiera o contatto esterno con data e ora.
Funzionamento: Gli ingressi possono eseguire le funzioni di peso netto/
lordo, azzeramento, picco, stampa oppure possono essere letti da remoto
mediante protocollo. Le uscite permettono l’impostazione dei set points
oppure possono essere comandate da remoto mediante protocollo.
Modello ANA con USCITA ANALOGICA 16 bit (65535 div.) optoisolata:
0-20mA; 4-20mA (max 300ohm); 0-10V; 0-5V; ±10 Vdc; ± 5 Vdc (min
10kohm).
Trasmettitore di peso approvatoOIMLR61 (Riempitrici gravimetriche
automatiche) in conformità a WELMEC Guide 8.8:2011 ( M.I.D.).
Versione CE-
M
approvata EN45501-2009/23/EC-OIML R76:2006
- Numero massimo di divisioni di verifica n=10000
- Minimo segnale d’ingresso per divisione di verifica 0,2 μV
- Strumento a campo unico o campi di pesatura plurimi (max 3) o divisioni
plurime (max 3)
- Calibrazione da tastiera con accesso mediante tabella password o
dispositivo hardware
- Funzioni di zero e tara semi-automatici e tara predeterminata
- Visualizzazione del peso in sottodivisioni (1/10 e)
- Stampa da contatto esterno dei seguenti valori : peso lordo, peso netto,
tara, tara predeterminata, data, ora, codice ID (memoria fiscale)
RIPETITORE DI PESO: il modello BASE/ANA può essere usato come
ripetitore di peso con setpoints.
Main functions
- 5 setpoints (4 setpoints for model ANA) configurable as normally open or
normally closed. The operator can decide the setpoints activation for the
net weight value, gross weight value, otherwise for positive weights or for
positive and negative weights.
- Setting of hysteresis value for each setpoint.
- 12 groups selection by 5 setpoint from selector switch or contacts (EC/E
options).
- Peak holder displaying by closing the Peak contact.
- Net/Gross function by keyboard or external contact.
- Manual adjustment of zero value in case of zero-setting not possible.
- Auto zero function.
- Auto zero-tracking function.
- Print of the weight via keyboard or external contact with date and time.
Operation: The inputs can work as: net/gross weight, zero-setting, peak, print
or can be remotely read via protocol.
The outputs can works as setpoints or can be remotely switched via
protocol.
Mod.ANAwith optoisolated ANALOG OUTPUT - 16 bit (65535 div.): 0-20mA;
4-20mA (max 300ohm); 0-10V; 0-5V; ±10V; ±5V (min 10kohm).
Weight transmitter approved OIML R61 (Automatic Gravimetric Filling
Instruments) according to WELMEC Guide 8.8:2011 (MID).
CE-
M
approvable EN45501-2009/23/EC-OIML R76:2006
- Maximum number of verification scale intervals n=10000
- Minimum input-voltage per VSI 0.2 μV
- Weighing range single range or multi range (max 3) or multi interval (max 3)
- Calibration via keyboard is protected through seals for the access to a setting
jumper or installer password
- Semi-automatic zero and tare, predetermined tare funcions.
- Weight subdivisions displaying (1/10 e)
- The following values can be printed from external contact: net/gross weight;
tare; predetermined tare; date; time; ID code (Alibi memory)
REMOTE DISPLAY: the model BASE/ANA can be used as a remote display
with setpoints.
MORSETTIERE ESTRAIBILI
EXTRACTABLE TERMINAL BOARDS
W200 BASE
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
W200 ANA
. . . . . . . . . . . . . . . . . . . . . Uscita analogica. . . . . . . . . . . . . .
W200
ANA
. . . . . . . . . . . . . . . . . . . . . . . . .Analog Output. . . . . . . . . . . . . . . .
- SUPPLY
+ SUPPLY
RXD
19
1
13
23456
16
14 15 1718
TXD
12
24
7811
109
21
20 22 23
RS232
12-24VDC
OUT 1
OUT 2
OUT 3
OUT 4
OUT COMMON
IN 1
IN 2
IN COMMON
INPUTS
supply 5-24VDC
OUTPUTS
max 115Vac
150mA IMPOSTABILI CON FUNZIONE DI:
- NETTO/LORDO
- ZERO SEMIAUTOMATICO
- PICCO
- STAMPA
oppure GESTIONE DA REMOTO.
THE INPUTS CAN BE REMOTELY
SWITCHED VIA PROTOCOL OR
WORK AS:
- NET/GROSS WEIGHT
- SEMI-AUTOMATIC ZERO
- PEAK
- PRINT
3 INGRESSI / 3 INPUTS
+ 0-20 4-20 mA
- COMMON
+ 0-10 VDC
OPTION
ANALOG OUTPUT
16
14 15
Current output:
max load 300 ohm
Voltage output:
min. load 10 kohm
EXCITAT. -
LOAD CELLS
SIGNAL +
EXCITAT. +
SIGNAL -
REF./SENSE -
REF./SENSE +
RS485
OUT 5
IN 3
INPUT
supply
5-24Vdc
6-WIRE load cell
CONNECTION
4-WIRE load cell
CONNECTION
24
SIGNAL +
19
EXCITAT. -
EXCITAT. +
SIGNAL -
2120 2322
12
EC OPTION
3
2
1
7
68
5
4
10
11
9
to IN COMMON
Se presente l'uscita analogica
non sono più disponibili:
- l'ingresso IN3
- l'uscita OUT5
- le opzioni E /EC
If analog output is present
therefore
are not available:
- IN3 input
- OUT5 output
- E / EC options
(1)
(1)
8
Buttons not included in the supply
E OPTION
1 32 45671411910 1312 1615
162
to OPT. E - EC
162
to instrument
CINQUE SETPOINTS
IMPOSTABILI O GESTIONE
DELLE USCITE DA REMOTO
VIA PROTOCOLLO.
THE OUTPUTS CAN WORK
AS 5 SET POINTS OR
CAN BE REMOTELY
SWITCHED VIA PROTOCOL.
5 USCITE / 5 OUTPUTS
5/4 USCITE (SETPOINT) - 3/2 INGRESSI
5/4 OUTPUT (SETPOINT) - 3/2 INPUT

26
26
DOSAGGIO MONOPRODOTTO IN CARICO
LOADING MONOPRODUCT BATCHING
W200 CARICO
W200 CARICO
Main functions
- Memorization of 99 different formulas with SET and PRESET.
- Setting of a only Slow value for all 99 formulas.
- Automatic fall calculation after one or more batching cycles.
- Tolerance value setting for each formula.
- “Tapping” function: It is possible to select the slow-on and slow-off times.
- 12 formula selection from selector switch or external contacts (EC/E
options).
- Autotare function after one or more batching cycles.
- It is possible to utilize the Tolerance and Alarm contacts as signals of
maximum and minimum.
- Batching start from external contact for only one cycle.
- Batching start via keyboard: it is possible to program the desired batching
cycles (max. 9999).
- Calculation of total consumption and consumption of each formula.
- The following values can be printed via the keyboard: constants, formulas,
consumption. Automatic printout of batching data.
- In the event of a power failure during batching, the microprocessor can
resume batching from the point of interruption.
- Pause of the batching by the keyboard.
Operation: By closing the START contact or by pressing the Start key, the
operator or external logic (EC/E options) selects the formula and starts the
batching. The instrument verifies that approval contact is closed (if available)
the weight is lower than the minimum one; executes the autotare (if enabled).
After the delay tare time has elapsed (max 99.9 sec.) it closes the set and
preset contacts. When the weight has reached the preset value the relative
contact is opened, once it has reached the set value minus the fall value the
set contact is opened and after the waiting time (max 999.9 sec.) after the
start contact is closed and the weight is stable (if enabled), it memorizes the
consumption value and closes the cycle end contact, sending the batching data
to the printer. When the weight has reached the minimum weight (unloading
phase) and after the safe emptying time has elapsed (max 999.9 sec.) the
instrument opens the cycle end contact. If more than one cycle has been
programmed, the instrument will continue automatically.
Weight transmitter approved OIML R61 (Automatic Gravimetric Filling
Instruments) according to WELMEC Guide 8.8:2011 (MID).
CE-
M
approvable EN45501-2009/23/EC-OIML R76:2006
FOR NON-AUTOMATIC BATCHING
Operation: During the start phase at the stable weight, with weight lower than
the minimum weight set, there are two possible operation modes: the storage of
the removable container’s tare weight or the scale zero-setting within 2% of the
maximum weight with fixed container. Once started the batching and reached
the Set value, the instrument stops the batching. To move on the unloading
phase and to store the weight in the alibi memory with the identification code
ID (if presents OPZWALIBI option) the weight must be steady and the operator
must close the start input or press the Menu button. The instrument closes
the end cycle contact to realize the unloading, increases the consumption
(if enabled) and performs the printing, if enabled. Once it has reached the
minimum weight and has finished the safe emptying time, it opens the end
cycle. At the steady weight condition, wait until the closing of the start input
or press the Start button to repeat the batching cycle.
Funzioni principali
- Memorizzazione di 99 diverse formule con valore di Set e Preset.
- Impostazione di un unico valore di Lento per tutte le 99 formule.
- Calcolo automatico del Volo dopo uno o più cicli di dosaggio.
- Impostazione di un valore di Tolleranza specifico per ogni formula.
- Impostazione dei tempi di pausa e lavoro per la funzione di “spillamento”.
- Selezione prime 12 formule da commutatore o contatti esterni (Opz. EC/E).
- Possibilità di effettuare l’autotara dopo uno o più cicli di dosaggio.
- Possibilità di utilizzare i contatti di Tolleranza e Allarme come minimo e
massimo.
- Start dosaggio da contatto esterno per un solo ciclo.
- Start dosaggio da tastiera con impostazione dei cicli (max. 9999).
- Calcolo del totale consumato e del consumo ripartito per formule.
- Stampa automatica dei dati di dosaggio ad ogni fine ciclo e stampa da
tastiera delle costanti, delle formule e dei consumi.
- Possibilità di riprendere automaticamente il dosaggio, dopo una
mancanza di tensione, dal punto in cui era stato interrotto.
- Pausa da tastiera durante il dosaggio.
Funzionamento: L’operatore o la logica esterna (opzioni EC/E) seleziona
la formula desiderata e avvia il dosaggio premendo il tasto START o
chiudendo il relativo contatto. Lo strumento verifica che il consenso sia
chiuso (se previsto), il peso sia inferiore al peso minimo, esegue l’autotara
(se prevista) trascorso il tempo di ritardo tara (max 99,9 sec.) poi chiude i
contatti di preset e set; raggiunto il valore di preset apre il relativo contatto,
raggiunto il valore di set meno il volo apre il contatto e trascorso il tempo
di attesa (max 999,9 sec.), dopo che è stato chiuso il contatto di start (se
abilitato) e il peso è stabile (se abilitato), memorizza il consumo e chiude
il fine ciclo inviando i dati in stampa; attende il raggiungimento del minimo
peso (fase di scarico) e trascorso il tempo di sicuro svuotamento (max 999,9
sec.) riapre il contatto di fine ciclo, predisponendosi per ricevere un nuovo
start o ripartendo automaticamente se più cicli sono stati programmati.
Trasmettitore di peso approvatoOIMLR61 (Riempitrici gravimetriche
automatiche) in conformità a WELMEC Guide 8.8:2011 ( M.I.D.).
Versione CE-
M
approvata EN45501-2009/23/EC-OIML R76:2006
PER DOSAGGIO NON AUTOMATICO
Funzionamento: Nella fase di start a peso stabile, con il peso inferiore
al minimo peso impostato, sono possibili due modi di funzionamento:
la memorizzazione del peso tara del contenitore asportabile oppure
l’azzeramento della bilancia entro il 2% del massimo peso con contenitore
fisso. Una volta avviato il dosaggio e raggiunto il valore di Set, lo strumento
arresta il dosaggio. Per passare alla fase di scarico e memorizzare il peso
nella memoria fiscale con il codice ID identificativo (se presente l’opzione
OPZWALIBI) il peso deve essere stabile e l’operatore deve chiudere
l’ingresso di start o premere il tasto Menu. Lo strumento chiude il contatto
di fine ciclo per eseguire lo scarico, incrementa il consumo (se abilitato)
ed esegue la stampa se prevista. Raggiunto il minimo peso e terminato
il tempo di sicuro svuotamento, si apre il fine ciclo. In condizione di peso
stabile, si attende la chiusura dell’ingresso di start o la pressione del tasto
start per ripetere il ciclo di dosaggio.
Ma
in
f
unct
io
ns
Fu
nz
io
ni
p
ri
nc
ip
al
i
W200 CARICO
. . . . . . . . . . . . . . 99 Formule . . . . . . . . . . . . . . . . . . . .
W200
LOAD
. . . . . . . . . . . . . . . . . . . . . . .99 Formulas . . . . . . . . . . . . . . . . . .
+ 0-20 4-20 mA
- COMMON
+ 0-10 VDC
OPTION
ANALOG OUTPUT
16
14 15
Current output:
max load 300 ohm
Voltage output:
min. load 10 kohm
- SUPPLY
+ SUPPLY
RXD
19
EXCITAT. -
1
13
23456
16
14 15 17 18
TXD
LOAD CELLS
SIGNAL +
EXCITAT. +
SIGNAL -
REF./SENSE -
REF./SENSE +
12
24
7811
109
21
20 22 23
RS232
12-24Vdc
RS485
PRESET
SET
END CYCLE
ALARM
OUT COMMON
START
STOP
IN COMMON
INPUTS
supply 5-24Vdc
TOLERANCE
IN 3
OUTPUTS
max 115Vac
150mA
INPUT
supply
5-24Vdc
6-WIRE load cell
CONNECTION
4-WIRE load cell
CONNECTION
24
SIGNAL +
19
EXCITAT. -
EXCITAT. +
SIGNAL -
2120 2322
12
EC OPTION
3
2
1
7
68
5
4
10
11
9
to IN COMMON
Se presente l'uscita analogica
non sono più disponibili:
- ingresso IN3
- uscita TOLLERANZA
- opzioni E /EC
Ingresso IN3 può avere le seguenti funzioni:
- ZERO SEMIAUTOMATICO (default)
- CONSENSO
- PESO NETTO / LORDO
If analog output is present therefore
are not available:
- IN3 input
- TOLERANCE output
- E / EC options
IN3 input has the following functions:
- SEMI-AUTOMATIC ZERO (default)
- APPROVAL
- NET / GROSS WEIGHT
*
*
(1)
(1)
8
Buttons not included in the supply
E OPTION
1 32 45671411910 1312 1615
162
to OPT. E - EC
162
to instrument

27
27
DOSAGGIO MONOPRODOTTO IN SCARICO
UNLOADING MONOPRODUCT BATCHING
W200 SCARICO
W200 SCARICO
Main functions
- Memorization of 99 different formulas with SET and PRESET.
- Setting of a only Slow value for all 99 formulas.
- Automatic fall calculation after one or more batching cycles.
- Tolerance value setting for each formula.
- “Tapping” function: It is possible to select the slow-on and slow-off times.
- 12 formula selection from selector switch or external contacts (EC/E
options).
- It is possible to utilize the Alarm/Tolerance contact as signals of maximum
or minimum.
- Batching start from external contact for only one cycle.
- Batching start via keyboard: it is possible to program the desired batching
cycles (max. 9999).
- Calculation of total consumption and consumption of each formula.
- The following values can be printed via the keyboard: constants, formulas,
consumption. Automatic printout of batching data.
- In the event of a power failure during batching, the microprocessor can
resume batching from the point of interruption.
- Pause of the batching by the keyboard.
- Automatic loading option if weight is below minimum value after batching.
- Possibility of unloading “big bag” by finishing the batching on next big bag
in case of product lower than the programmed quantity.
Operation: By closing the START contact or by pressing the Start key, the
operator or external logic (EC/E options) selects the formula and starts
the batching. The instrument verifies that the approval contact is closed (if
enabled), that there is enough weight on scale to perform the batching, displays
“0” and then closes the set and preset contacts. The net weight increase is
displayed while the weight is extracted. When the weight reaches the preset
value the relative contact is opened, and when the set value minus the fall value
is reached, the set contact is opened. Once elapsed the waiting time (max
999.9 sec., if enabled in the constants), after the start contact was closed and
the weight is stable, the weight indicator memorizes the consumption a closes
the cycle-end contact sending data for printing.The instrument opens the end
cycle contact, after the safe emptying time has elapsed, then the instrument
prepares to receive a new start or restart automatically if more cycles were
programmed from the keyboard.
Weight transmitter approved OIML R61 (Automatic Gravimetric Filling
Instruments) according to WELMEC Guide 8.8:2011 (MID).
CE-
M
approvable EN45501-2009/23/EC-OIML R76:2006
FOR NON-AUTOMATIC BATCHING
Operation: By closing the START contact or by pressing the Start key, the
operator or external logic (EC/E options) selects the formula and starts the
batching. The instrument starts the batching and checks that the approval is
closed (if enable), that the weight on scale is enough to perform the batching,
then closes the set and preset contacts; (the display shows the gross weight
decreases). Once reached the Set value, the instrument stops the batching.
To stop the batching and to store the weight in the alibi memory with the
identification code ID (if presents OPZWALIBI option) the weight must be
steady and the operator must close the start input or press the Menu/Enter
button. The instrument closes the end cycle contact for the set time, increases
the consumption (if enable) and performs the printing, if enabled. At the steady
weight condition, wait until the closing of the start input or press the Start
button to repeat the batching cycle.
Funzioni principali
- Memorizzazione di 99 diverse formule con valore di Set e Preset.
- Impostazione di un unico valore di Lento per tutte le 99 formule.
- Calcolo automatico del Volo dopo uno o più cicli di dosaggio.
- Impostazione di un valore di Tolleranza specifico per ogni formula.
- Impostazione dei tempi di pausa e lavoro per la funzione di “spillamento”.
- Selezione prime 12 formule da commutatore o contatti esterni (Opz. EC/E).
- Possibilità di utilizzare il contatto diAllarme/Tolleranza come minimo o max.
- Start dosaggio da contatto esterno per un solo ciclo.
- Start dosaggio da tastiera con impostazione dei cicli (max. 9999).
- Calcolo del totale consumato e del consumo ripartito per formule.
- Stampa automatica dei dati di dosaggio ad ogni fine ciclo e stampa da
tastiera delle costanti, delle formule e dei consumi.
- Possibilità di riprendere automaticamente il dosaggio, dopo una
mancanza di tensione, dal punto in cui era stato interrotto.
- Pausa da tastiera durante il dosaggio.
- Possibilità di effettuare il carico automatico quando al termine di un
dosaggio si scende sotto il peso minimo.
- Possibilità di scarico “big bag” (saccone) con completamento del
dosaggio sul saccone successivo in caso di prodotto inferiore alla
quantità impostata in estrazione.
Funzionamento: L’operatore o la logica esterna (opzioni EC/E) seleziona
la formula desiderata e avvia il dosaggio premendo il tasto START o
chiudendo il relativo contatto. Lo strumento verifica che il consenso sia chiuso
(se previsto) e che il peso presente in bilancia sia sufficiente per eseguire
il dosaggio, visualizza “0” poi chiude i contatti di preset e set. A display
viene visualizzato il peso netto che incrementa mentre si estrae il prodotto.
Raggiunto il valore di preset il microprocessore apre il relativo contatto,
raggiunto il valore di set meno il volo apre il relativo contatto; trascorso il
tempo di attesa (max 999,9 sec.), se abilitato nelle costanti, dopo che è stato
chiuso il contatto di start e il peso è stabile, memorizza il consumo e chiude
il fine ciclo inviando i dati di dosaggio in stampa. Il fine ciclo resta chiuso per
il tempo di sicuro svuotamento, poi si apre e lo strumento si predispone per
ricevere un nuovo start o ripartendo automaticamente nel caso siano stati
programmati più cicli da tastiera.
Trasmettitore di peso approvatoOIMLR61 (Riempitrici gravimetriche
automatiche) in conformità a WELMEC Guide 8.8:2011 ( M.I.D.).
Versione CE-
M
approvata EN45501-2009/23/EC-OIML R76:2006
PER DOSAGGIO NON AUTOMATICO
Funzionamento:L’operatore o la logica esterna (opzioni EC/E) seleziona la
formula desiderata e avvia il dosaggio premendo il tasto STARTo chiudendo
il relativo contatto. Lo strumento verifica che il consenso sia chiuso (se
previsto), il peso presente in bilancia sia sufficiente per eseguire il dosaggio,
poi chiude i contatti di preset e set; (a display viene visualizzato il peso lordo
che decrementa). Una volta raggiunto il valore di set, lo strumento arresta
il dosaggio. Per terminare il dosaggio e memorizzare il peso nella memoria
fiscale con il codice ID identificativo (se presente l’opzione OPZWALIBI)
il peso deve essere stabile e l’operatore deve chiudere l’ingresso di start
o premere il tasto Menu/Enter. Lo strumento chiude il contatto di fine ciclo
per il tempo impostato, incrementa il consumo (se abilitato) ed esegue la
stampa se prevista. In condizione di peso stabile, si attende la chiusura
dell’ingresso di start o la pressione del tasto start per ripetere il ciclo.
Main functions
Funzioni principali
W200 SCARICO
. . . . . . . . . . . . 99 Formule . . . . . . . . . . . . . . . . . . . .
W200
UNLOAD
. . . . . . . . . . . . . . . . . .99 Formulas . . . . . . . . . . . . . . . . . .
+ 0-20 4-20 mA
- COMMON
+ 0-10 VDC
OPTION
ANALOG OUTPUT
16
14 15
Current output:
max load 300 ohm
Voltage output:
min. load 10 kohm
- SUPPLY
+ SUPPLY
RXD
19
EXCITAT. -
1
13
23456
16
14 15 17 18
TXD
LOAD CELLS
SIGNAL +
EXCITAT. +
SIGNAL -
REF./SENSE -
REF./SENSE +
12
24
7811
109
21
20 22 23
RS232
12-24Vdc
RS485
PRESET
SET
END CYCLE
LOAD
OUT COMMON
START
STOP
IN COMMON
INPUTS
supply 5-24Vdc
ALARM / TOLERANCE
IN 3
OUTPUTS
max 115Vac
150mA
INPUT
supply
5-24Vdc
6-WIRE load cell
CONNECTION
4-WIRE load cell
CONNECTION
24
SIGNAL +
19
EXCITAT. -
EXCITAT. +
SIGNAL -
2120 2322
12
EC OPTION
3
2
1
7
68
5
4
10
11
9
to IN COMMON
Se presente l'uscita analogica
non sono più disponibili:
- ingresso IN3
- uscita ALLARME / TOLLERANZA
- opzioni E /EC
Ingresso IN3 può avere le seguenti funzioni:
- ZERO SEMIAUTOMATICO (default)
- CONSENSO
- PESO NETTO / LORDO
- CARICO AUTOMATICO durante il dosaggio
If analog output is present therefore
are not available:
- IN3 input
- ALARM / TOLERANCE output
- E / EC options
IN3 input has the following functions:
- SEMI-AUTOMATIC ZERO (default)
- APPROVAL
- NET / GROSS WEIGHT
- AUTOMATIC LOADING during batching
*
*
(1)
(1)
8
Buttons not included in the supply
E OPTION
1 32 45671411910 1312 1615
162
to OPT. E - EC
162
to instrument

28
28
W200
W200
3-6-14 PRODOTTI
3-6-14 PRODOTTI
DOSAGGIO 3 / 6 / 14 PRODOTTI
BATCHING 3 / 6 / 14 PRODUCTS
Main functions
- Memorization of 99 different formulas.
- Programming products in a fixed increasing order or to steps 3/6/14, recalling
the product in the desired order, repeating several times the same product
(if possible).
- Setting of Fall, Slow and Tolerance values for each product.
- Automatic fall value calculation for each product.
- “Tapping” function: It is possible to select the slow-on and slow-off times.
- 12 formula selection from selector switch or external contacts (EC/E
options).
- Batching in net weight for each product.
- It is possible to use the Alarm contact as signals of maximum and
minimum.
- Batching start from external contact for only one cycle.
- Batching start via keyboard: it is possible to program the desired batching
cycles (max. 9999).
- Calculation of total consumption for each product.
- The following values can be printed via the keyboard: constants, formulas,
consumption. Automatic printout of batching data.
- In the event of a power failure during batching, the microprocessor can
resume batching from the point of interruption.
- Pause of the batching by the keyboard.
Operation: By closing the START contact or by pressing the Start key, the
operator or external logic (EC/E options) selects the formula and starts
the batching. The instrument verifies that the approval contact is closed (if
enabled), the weight is lower than the minimum one, executes the autotare (if
enabled), then closes the contact of the first product set. Once reached the set
value minus the Fall value, minus the Slow value, it closes its Slow contatct.
Once reached the set value minus the fall value, it opens the product contact
and Slow contact and when the waiting time has elapsed (max 999,9 sec.),
after the start contact has been closed (if enabled) and the weight is stable(if
enabled), memorizes the consumption (if available) and closes the contact
of another product if set in formula. Otherwise it closes the end cycle contact
sending the data to the printer. When the weight has reached the minimum
weight (unloading phase) and after the safe emptying time has elapsed (max
999.9 sec.) the instrument reopens the cycle end contact. If more than one
cycle has been programmed, the instrument will continue automatically or
getting ready to receive a new start.
Weight transmitter approved OIML R61 (Automatic Gravimetric Filling
Instruments) according to WELMEC Guide 8.8:2011 (MID).
CE-
M
approvable EN45501-2009/23/EC-OIML R76:2006
FOR NON-AUTOMATIC BATCHING
Operation: During the start phase at the stable weight, with weight lower
than the minimum weight set, there are two possible operation modes: the
storage of the removable container’s tare weight or the scale zero-setting within
2% of the maximum weight with fixed container. Once started the batching
and reached the Set value about the first product, the instrument stops the
batching. To move to the following product, to increase the consumption, to
store the value in the alibi memory with the identification code ID (if presents
OPZWALIBI option) and to send data to the printer (if enable), the weight must
be steady and the operator must close the start input or press the Menu/Enter
button. This sequence is repeated for all the products by order of the operator,
through the closure of the start input or the Menu/Enter button, until the final
product. The instrument closes the end cycle to realize the unloading. Once it
has reached the minimum weight and has finished the safe emptying time, it
opens the end cycle. At the steady weight condition, wait until the closing of
the start input or press the Start button to repeat the batching cycle.
Funzioni principali
- Memorizzazione di 99 diverse formule.
- Programmazione prodotti in ordine fisso crescente oppure a passi
(3/6/14) richiamando il prodotto nell’ordine desiderato ripetendo anche
più volte lo stesso prodotto (ove possibile).
- Impostazione dei valori di Volo, Lento, Tolleranza per ogni prodotto.
- Calcolo automatico del valore di Volo per ogni prodotto.
- Impostazione dei tempi di pausa e lavoro per la funzione di “spillamento”.
- Selezione prime 12 formule da commutatore o contatti esterni (Opz. EC/E).
- Dosaggio in peso netto per ogni prodotto.
- Possibilità di utilizzare il contatto di Allarme come minimo o massimo
peso.
- Start dosaggio da contatto esterno per un solo ciclo.
- Start dosaggio da tastiera con impostazione dei cicli (max. 9999).
- Calcolo del totale consumato per ogni prodotto.
- Stampa automatica dei dati di dosaggio ad ogni fine ciclo e stampa da
tastiera delle costanti, delle formule e dei consumi.
- Possibilità di riprendere automaticamente il dosaggio, dopo una
mancanza di tensione, dal punto in cui era stato interrotto.
- Pausa da tastiera durante il dosaggio.
Funzionamento: L’operatore o la logica esterna (opzioni EC/E) seleziona
la formula desiderata e avvia il dosaggio premendo il tasto START o
chiudendo il relativo contatto. Lo strumento verifica che il consenso sia
chiuso (se abilitato), il peso sia inferiore al peso minimo, esegue l’autotara
(se prevista), poi chiude il contatto del primo prodotto programmato.
Raggiunto il valore impostato meno il Volo, meno il Lento, chiude il contatto
di Lento. Raggiunto il valore impostato meno il Volo apre il contatto del
prodotto e del Lento, trascorso il tempo di attesa (max 999,9 sec.), dopo
che è stato chiuso il contatto di start (se abilitato) e il peso è stabile (se
abilitato), memorizza il consumo (se previsto) e chiude il contatto di un
altro prodotto se prorammato in formula; altrimenti chiude il fine ciclo
inviando i dati in stampa; attende il raggiungimento del minimo peso (fase
di scarico) e trascorso il tempo di sicuro svuotamento (max 999,9 sec.)
riapre il contatto di fine ciclo, predisponendosi per ricevere un nuovo start
o ripartendo automaticamente se più cicli sono stati programmati.
Trasmettitore di peso approvatoOIMLR61 (Riempitrici gravimetriche
automatiche) in conformità a WELMEC Guide 8.8:2011 ( M.I.D.).
Versione CE-
M
approvata EN45501-2009/23/EC-OIML R76:2006
PER DOSAGGIO NON AUTOMATICO
Funzionamento: Nella fase di start a peso stabile, con il peso inferiore
al minimo peso impostato, sono possibili due modi di funzionamento:
la memorizzazione del peso tara del contenitore asportabile oppure
l’azzeramento della bilancia entro il 2% del massimo peso con contenitore
fisso. Una volta avviato il dosaggio e raggiunto il valore di Set per il
primo prodotto, lo strumento arresta il dosaggio. Per passare al prodotto
successivo, incrementare il consumo, memorizzare il valore nella memoria
fiscale con il codice ID identificativo (se presente l’opzione OPZWALIBI),
ed inviare il dato alla stampante (se prevista), il peso deve essere
stabile e l’operatore deve chiudere l’ingresso di start o premere il tasto
Menu/Enter. Questa sequenza si ripeterà per tutti i prodotti su comando
dell’operatore mediante la chiusura dell’ingresso di start o del tasto Menu/
Enter, fino all’ultimo prodotto. Lo strumento chiude il contatto di fine ciclo
per eseguire lo scarico. Raggiunto il minimo peso e terminato il tempo
di sicuro svuotamento, si apre il contatto di fine ciclo. In condizione di
peso stabile, si attende la chiusura dell’ingresso di start o la pressione
del tasto start per ripetere il ciclo di dosaggio.
W200 3 PRODOTTI
. . . . . . . 99 Formule . . . . . . . . . . . . . . . . . . . .
W200
3 PRODUCTS
. . . . . . . . . . . .99 Formulas . . . . . . . . . . . . . . . . . .
W200 6 PRODOTTI
. . . . . . . 99 Formule . . . . . . . . . . . . . . . . . . . .
W200
6 PRODUCTS
. . . . . . . . . . . .99 Formulas . . . . . . . . . . . . . . . . . .
W200 14 PRODOTTI
. . . . . 99 Formule . . . . . . . . . . . . . . . . . . . .
W200
14 PRODUCTS
. . . . . . . . . .99 Formulas . . . . . . . . . . . . . . . . . .
Mod. 6 PRODUCT includes:
- one 8-relay module mod. RELE6PROD (80 x 160 x h 60 mm), supplied
with 12-24VDC supply or 115 VAC or 230 VAC.
Mod. 14 PRODUCT includes:
- one 8-relay module mod. RELE6PROD (80 x 160 x h 60 mm), supplied
with 12-24VDC supply or 115 VAC or 230 VAC.
- one 8-relay module mod. RELE14PROD (80 x 120 x h 60 mm).
Il modello 6 PRODOTTI viene fornito completo di:
- 1 modulo 8-relè RELE6PROD (80 x 160 x h 60 mm) fornibile con
alimentazione 12-24Vcc o 115Vca o 230 Vca.
Il modello 14 PRODOTTI viene fornito completo di:
- 1 modulo 8-relè RELE6PROD (80 x 160 x h 60 mm) fornibile con
alimentazione 12-24Vcc o 115Vca o 230 Vca.
- 1 modulo 8-relè RELE14PROD (80 x 120 x h 60 mm).

29
29
+ 0-20 4-20 mA
- COMMON
+ 0-10 VDC
OPTION
ANALOG OUTPUT
16
14 15
Current output:
max load 300 ohm
Voltage output:
min. load 10 kohm
- SUPPLY
+ SUPPLY
RXD
19
EXCITAT. -
1
13
23456
16
14 15 1718
TXD
LOAD CELLS
SIGNAL +
EXCITAT. +
SIGNAL -
REF./SENSE -
REF./SENSE +
12
24
7811
109
21
20 22 23
RS232
12-24Vdc
RS485
START
STOP
IN COMMON
INPUTS
supply 5-24Vdc
ALARM
IN 3
INPUT
supply
5-24Vdc
6-WIRE load cell
CONNECTION
to IN COMMON
*
(1)
RELE6PROD24V
12-24
Vdc
4-WIRE load cell
CONNECTION
24
SIGNAL +
19
EXCITAT. -
EXCITAT. +
SIGNAL -
2120 2322
12
EC OPTION
3
2
1
7
68
5
4
10
11
9
8
E OPTION
1 32 45671411910 1312 1615
162
162
to W200
to OPT. E - EC
R5
R1
R2
R3
R4
OUT COMMON
RELE
17
IN COM
-
+
PROD.5 NO
PROD.4 COM
PROD.4 NO
PROD.3 COM
PROD.3 NO
PROD.2 COM
PROD.2 NO
PROD.1 COM
PROD.1 NO
IN4
IN1
IN2
IN3
8
L3
N 4 567
RELE
RELE
RELE
131091211 15
14 16
P2
P1
POWER
P4
P3
PROD.6 COM
SLOW COM
SLOW NO
CYCLE END COM
CYCLE END NO
PROD.6 NO
PROD.5 COM
RELE RELE RELE
201918 2221 23 24
FC
P6
P5 LE
RELE
DOSAGGIO 3 / 6 / 14 PRODOTTI
BATCHING 3 / 6 / 14 PRODUCTS
W200
W200
3-6-14 PRODOTTI
3-6-14 PRODOTTI
14 PRODOTTI / PRODUCTS
3 PRODOTTI / PRODUCTS
6 PRODOTTI / PRODUCTS
Se presente l'uscita analogica
non sono più disponibili:
- ingresso IN3
- uscita LENTO / ALLARME
- opzioni E /EC
Ingresso IN3 può avere le seguenti funzioni:
- ZERO SEMIAUTOMATICO
- CONSENSO (default)
- NETTO/LORDO
If analog output is present therefore
are not available:
- IN3 input
- SLOW / ALARM output
- E / EC options
IN3 input has the following functions:
- SEMI-AUTOMATIC ZERO.
- APPROVAL (default)
- NET/GROSS WEIGHT
*
(1)
+ 0-20 4-20 mA
- COMMON
+ 0-10 VDC
OPTION
ANALOG OUTPUT
16
14 15
- SUPPLY
+ SUPPLY
RXD
19
EXCITAT. -
1
13
23456
16
14 15 1718
TXD
LOAD CELLS
SIGNAL +
EXCITAT. +
SIGNAL -
REF./SENSE -
REF./SENSE +
12
24
7811
109
21
20 22 23
RS232
12-24Vdc
RS485
(R1) PROD. 1
(R2) PROD. 2
(R3) PROD. 3
(R4) CYCLE END
OUT COMMON
START
STOP
IN COMMON
INPUTS
supply 5-24Vdc
SLOW / ALARM
IN 3
OUTPUTS
max 115 Vac
150mA
INPUT
supply
5-24Vdc
6-WIRE load cell
CONNECTION
4-WIRE load cell
CONNECTION
24
SIGNAL +
19
EXCITAT. -
EXCITAT. +
SIGNAL -
2120 2322
to IN COMMON
*
(1)
12
EC OPTION
3
2
1
7
68
5
4
10
11
9
8
Buttons not included in the supply
E OPTION
1 32 45671411910 1312 1615
162
162
to instrument
to OPT. E - EC
Current output:
max load 300 ohm
Voltage output:
min.load 10 kohm
R5
R1 R2 R3 R4 OUTPUTS
0 0 0 I PROD. 7
I 0 0 I PROD. 8
0I0IPROD. 9
I I 0 I PROD. 10
0 0 I I PROD. 11
I 0 I I PROD. 12
0 I I I PROD. 13
IIIIPROD. 14
RELE14PROD MODULE
R1 R2 R3 R4 OUTPUTS
I I I 0 PROD. 1
0 I I 0 PROD. 2
I0I0PROD. 3
0 0 I 0 PROD. 4
I I 0 0 PROD. 5
0 I 0 0 PROD. 6
I 0 0 0 CYCLE END
X X X I SLOW
RELE6PROD MODULE
solo nel 6 PRODOTTI / 6 PRODUCTS only
- SUPPLY
+ SUPPLY
RXD
19
EXCITAT. -
1
13
23456
16
14 15 1718
TXD
LOAD CELLS
SIGNAL +
EXCITAT. +
SIGNAL -
REF./SENSE -
REF./SENSE +
12
24
7811
109
21
20 22 23
RS232
12-24Vdc
RS485
START
STOP
IN COMMON
INPUTS
supply 5-24Vdc
SLOW / ALARM
IN 3
INPUT
supply
5-24Vdc
6-WIRE load cell
CONNECTION
to IN COMMON
*
+ 0-20 4-20 mA
- COMMON
+ 0-10 VDC
OPTION
ANALOG OUTPUT
16
14 15
Current output:
max load 300 ohm
Voltage output:
min. load 10 kohm
(1)
4-WIRE load cell
CONNECTION
24
SIGNAL +
19
EXCITAT. -
EXCITAT. +
SIGNAL -
2120 2322
12
EC OPTION
3
2
1
7
68
5
4
10
11
9
8
E OPTION
1 32 45671411910 1312 1615
162
162
to W200
to OPT. E - EC
R5
R1
R2
R3
R4
OUT COMMON
RELE6PROD24V
12-24
Vdc
17
IN COM
-
+
PROD.5 NO
PROD.4 COM
PROD.4 NO
PROD.3 COM
PROD.3 NO
PROD.2 COM
PROD.2 NO
PROD.1 COM
PROD.1 NO
IN4
IN1
IN2
IN3
8
L3
N 4 567131091211 15
14 16
P2
P1
POWER
P4
P3
PROD.6 COM
CYCLE END COM
CYCLE END NO
PROD.6 NO
PROD.5 COM
201918 2221 23 24
FC
P6
P5 LE
P11
9
PROD.11 NO
PROD.10 COM
PROD.10 NO
PROD.9 COM
PROD.9 NO
PROD.8 COM
PROD.8 NO
PROD.7 COM
PROD.7 NO
21 3457
6 8
P8
P7 P10
P9
PROD.12 COM
PROD.14 COM
PROD.14 NO
PROD.13 COM
PROD.13 NO
PROD.12 NO
PROD.11 COM
10 11 12 14
13 15 16
P13
P12
POWER
P14
RELE14PROD
RELAY
RELAYRELAY
RELAYRELAY
RELAY
RELAY
RELAY
RELAY RELAY RELAY RELAY RELAY RELAY RELAY RELAY
This manual suits for next models
8
Table of contents
Other LAUMAS Accessories manuals