lec medical Pharmacy Plus Series User manual

0
083870100 - Rev05 - 27/07/22
www.lec-medical.co.uk
USER MANUAL
The Experts in
Medical Refrigeration
Pharmacy Plus - Laboratory Plus - Pharmacy Connect
Operating Instructions

1
Contents
1: Models................................................................................................................................................................ 2
2: Safety Instructions.............................................................................................................................................. 4
3: General Recommendations................................................................................................................................ 5
4: Product Specifications........................................................................................................................................ 6
Flammable Material Storage Units FMS
(Lab products only)
........................................................................... 8
5: Product Details
.................................................................................................................................................. 9
5:1 Pharmacy Plus Refrigerators ........................................................................................................................ 9
5:2 Laboratory Plus Refrigerators..................................................................................................................... 10
5:3 Laboratory Plus Freezers............................................................................................................................ 11
5:4 Laboratory Plus Refrigerator/Freezer Combi............................................................................................. 12
6: Installation
....................................................................................................................................................... 13
Positioning and safely using the Refrigerator .................................................................................................. 13
Electrical Connections ...................................................................................................................................... 14
7: Before Switching On
............................................................................................................................................. 15
8: Operation.......................................................................................................................................................... 16
IJ Controller Overview ...................................................................................................................................... 16
9: Basic Operations using the LEC Medical App ................................................................................................... 17
9:1 Download and install the LEC Medical App................................................................................................ 17
9:2 Connecting to an appliance........................................................................................................................ 17
9:3 App Home Page .......................................................................................................................................... 18
9:6 Accessing Min/Max temperatures ............................................................................................................. 18
9:5 Re-Setting Min/Max Temperatures using the APP .................................................................................... 19
9:7 Re-Naming the Appliance........................................................................................................................... 19
9:8 Changing the Set Point ............................................................................................................................... 20
Operating the internal light.............................................................................................................................. 20
9:9 Switching the appliance on and off............................................................................................................ 21
10: Advanced Operations using the LEC Medical App ......................................................................................... 22
11: Operations using the controller touch screen ............................................................................................... 23
11:1 Unlocking the controller........................................................................................................................... 23
11:2 Viewing and re-Setting Min/Max Temperatures on the controller......................................................... 23
11:2:1 Select air or load temperature.......................................................................................................... 23
11:2:2 To View the max and min temperature............................................................................................ 23
11:2:3 To reset max and min temperatures................................................................................................. 24
11:3 Changing the Set Point ............................................................................................................................. 25
12: Alarm Status
.................................................................................................................................................. 26
14: Disposal of your refrigerator .......................................................................................................................... 28
15: Contact Information ....................................................................................................................................... 29

2
1: Models
Range
Vol L
SKU No
Model
Pharmacy Plus - Neonatal
158
444411308
PPSR158BT-UK
444411311
PPSR158BT-EU
444411325
PPSR158BT-DWP-UK Boots
444411387
PPSR158BT-DWP
444411389
PPSR158BT-DLK
444411377
NSR158BT-UK
444411309
PPGR158BT-UK
444411310
PPGR158BT-LHH-UK
444411312
PPGR158BT-EU
444411388
PPGR158BT-DWP
444411390
PPGR158BT-DLK
310
444411313
PPSR310BT
444411394
PPSR310BT-DWP
444411391
PPSR310BT-DLK
444411314
PPGR310BT
444411315
PPGR310BT-LHH
444411393
PPGR310BT-DWP
444411392
PPGR310BT-DLK
400
444411317
PPSR400BT
444411398
PPSR400BT-DWP
444411396
PPSR400BT-DLK
444411316
PPGR400BT
444411318
PPGR400BT-LHH
444411397
PPGR400BT-DWP
444411395
PPGR400BT-DLK
Pharmacy Connect
158
444411319
PCSR158CT-UK
444411321
PCSR158CT-EU
444411323
PCSR158CT-DWP-UK
444411326
PCSR158CT-DLK-UK
444411320
PCGR158CT-UK
444411322
PCGR158CT-EU
444411324
PCGR158CT-DWP-UK
444411327
PCGR158CT-DLK-UK
310
444411328
PCSR310CT
444411330
PCSR310CT-DLK
444411332
PCSR310CT-DWP
444411329
PCGR310CT
444411331
PCGR310CT-DLK
444411333
PCGR310CT-DWP
400
444411335
PCSR400CT
444411337
PCSR400CT-DLK
444411339
PCSR400CT-DWP
444411334
PCGR400CT
444411336
PCGR400CT-DLK
444411338
PCGR400CT-DWP

3
Models
cont.
Range
Vol L
SKU No
Model
Pharmacy Plus
Neonatal
47
444411305
PPSR47BT-UK
444411307
PPSR47BT-EU
444411306
PPGR47BT-UK
444411376
NSR47BT-UK
444411305
PPSR47BT-UK
444411307
PPSR47BT-EU
444411306
PPGR47BT-UK
Range
Vol L
SKU No
Model
Laboratory Plus
158
444411358
LSFSR158BT-UK
444411359
LSFSR158BT-EU
310
444411360
LSFSR310BT-UK
444411361
LSFSR310BT-UK-ATEX
400
444411364
LSFSR400BT
444411365
LSFSR400BT-ATEX
98
444411352
LSFSF98BT-UK
444411353
LSFSF98BT-EU
242
444411362
LSFSF242BT-UK
444411363
LSFSF242BT-UK-ATEX
312
444411366
LSFSF312BT
444411367
LSFSF312BT-ATEX
280
444411369
LSFSC280BT
444411370
LSFSC280BT-ATEX

4
2: Safety Instructions
In this manual, the following symbols and conventions are used: -
This symbol when used alone indicates important operating instructions which reduce the risk
of injury or poor performance of the unit.
WARNING: A situation which if not avoided, could result in serious injury or death.
CAUTION: A situation which, if not avoided, may result in minor or moderate injury, impaired
performance, or damage to the equipment.
CAUTION: Before installing, using, or maintainingthisproduct, pleasebe sure to read this manual
and product warning labels carefully. Failure to follow these instructions may cause this product to
malfunction, which could result in injury or damage.
WARNING: Potential danger of electric shock which,if not avoided, could result in serious injuryor
death.
WARNING: These units are charged with hydrocarbon refrigerant. Only qualified service personnel
should service these units.
The snowflake symbol indicates extreme low temperatures and high risk of frostbite. Do not touch
bare metal or samples with unprotected body parts.
WARNING: This symbol indicates a need to use gloves during the indicated procedures. If
performing decontamination procedures, use chemically resistant gloves. Use insulated
gloves for handling samples to avoid potential frostbite.

5
3: General Recommendations
Intended Use and Special Warning
This equipment is tested in compliance with established regulations and then shipped ready for use. This
equipment is intended for cold storage and is not to be used in the presence of explosive gases or mixtures
and/or close to sources with high magnetic or electric fields/
WARNING: These units are not medical
devices and have not been registered with a
medical device regulatory body (e.g.,
MDD/MDR). These products have not been
evaluated for the storage ofsamples for
diagnostic use, nor for samples to be re-
introduced into the body.
WARNING: Do not damage the
refrigeration circuit
WARNING: Do not use electrical
equipment inside the storage unless they
are of the type recommended by the
manufacturer.
WARNING: Keep ventilation openings, in
the equipment enclosure or in the built-in
structure, clear of obstruction.
WARNING: Do not use mechanical
devices or other means to accelerate the
defrosting process, other than those
recommended by the manufacturer
Energy Saving Tips
This equipment uses energy efficient R600a refrigerant.
To keep running costs as low as possible always:
•Position the equipment away from heat sources.
•Make sure the air can circulate freely around the equipment, don’t block ventilation grid
•Ensure that products being stored are below room
temperature upon entry.
•Make sure the door is opened as little as possible while in
use and closed as quickly as possible to prevent
unnecessary temperature fluctuations.
Important Information
R600a
The refrigerator contains environment-friendly, non-ozone depleting refrigerant R600a. As R600a
is a flammable gas, it is important to avoid damage to the refrigeration circuit during transport and
installation. If the refrigeration circuit is damaged, avoid using a naked flame in the vicinity of the
refrigerator and connecting power to the refrigerator. Also make sure there is good ventilation in
the room. If you are in doubt, please contact your supplier.

6
4: Product Specifications
This range of LEC refrigerators and freezers have been designed and built with the intention of the product
being used within pharmacies, hospitals, and laboratories.
Please see below for specific product information.
Pharmacy Plus and Neonatal Range Refrigerators
SKU No
Model
Height
(mm)
Width
(mm)
Depth
Inc Handle
(mm)
Weight
(Kg)
Rating
(Amp)
Power
(W)
Temperature
Range
Ambient
Temperature
Refrigerant
444411305
PPSR47BT-UK
565
475
445
17.5
0.60
70
2⁰C to 8⁰C
16⁰C to 32⁰C
R600a
444411307
PPSR47BT-EU
565
475
445
17.5
0.60
70
2⁰C to 8⁰C
16⁰C to 32⁰C
R600a
444411306
PPGR47BT-UK
565
475
445
18.5
0.60
70
2⁰C to 8⁰C
16⁰C to 32⁰C
R600a
444411376
NSR47BT-UK
565
475
445
17.5
0.60
70
2⁰C to 4⁰C
25⁰C to 32⁰C
R600a
444411308
PPSR158BT-UK
850
595
660
33.3
0.78
101
2⁰C to 8⁰C
16⁰C to 32⁰C
R600a
444411311
PPSR158BT-EU
850
595
660
33.3
0.78
101
2⁰C to 8⁰C
16⁰C to 32⁰C
R600a
444411325
PPSR158BT-DWP-UK
Boots
850
595
660
38.3
0.78
101
2⁰C to 8⁰C
16⁰C to 32⁰C
R600a
444411387
PPSR158BT-DWP
850
595
660
38.3
0.78
101
2⁰C to 8⁰C
16⁰C to 32⁰C
R600a
444411389
PPSR158BT-DLK
850
595
660
33.3
0.78
101
2⁰C to 8⁰C
16⁰C to 32⁰C
R600a
444411377
NSR158BT-UK
850
595
660
38.3
0.78
101
2⁰C to 4⁰C
25⁰C to 32⁰C
R600a
444411309
PPGR158BT-UK
850
595
645
36.3
0.78
101
2⁰C to 8⁰C
16⁰C to 32⁰C
R600a
444411310
PPGR158BT-LHH-UK
850
595
645
36.3
0.78
101
2⁰C to 8⁰C
16⁰C to 32⁰C
R600a
444411312
PPGR158BT-EU
850
595
645
36.3
0.78
101
2⁰C to 8⁰C
16⁰C to 32⁰C
R600a
444411388
PPGR158BT-DWP
850
595
645
39.3
0.78
101
2⁰C to 8⁰C
16⁰C to 32⁰C
R600a
444411390
PPGR158BT-DLK
850
595
645
36.3
0.78
101
2⁰C to 8⁰C
16⁰C to 32⁰C
R600a
444411313
PPSR310BT
1560
595
660
50.0
0.65
88
2⁰C to 8⁰C
16⁰C to 32⁰C
R600a
444411394
PPSR310BT-DWP
1560
595
660
58.0
0.65
88
2⁰C to 8⁰C
16⁰C to 32⁰C
R600a
444411391
PPSR310BT-DLK
1560
595
660
50.0
0.65
88
2⁰C to 8⁰C
16⁰C to 32⁰C
R600a
444411314
PPGR310BT
1560
595
645
60.0
0.65
88
2⁰C to 8⁰C
16⁰C to 32⁰C
R600a
444411315
PPGR310BT-LHH
1560
595
645
50.0
0.65
88
2⁰C to 8⁰C
16⁰C to 32⁰C
R600a
444411393
PPGR310BT-DWP
1560
595
645
68.6
0.65
88
2⁰C to 8⁰C
16⁰C to 32⁰C
R600a
444411392
PPGR310BT-DLK
1560
595
645
50.0
0.65
88
2⁰C to 8⁰C
16⁰C to 32⁰C
R600a
444411317
PPSR400BT
1925
595
660
61.8
0.65
88
2⁰C to 8⁰C
16⁰C to 32⁰C
R600a
444411398
PPSR400BT-DWP
1925
595
660
74.8
0.65
88
2⁰C to 8⁰C
16⁰C to 32⁰C
R600a
444411396
PPSR400BT-DLK
1925
595
660
61.8
0.65
88
2⁰C to 8⁰C
16⁰C to 32⁰C
R600a
444411316
PPGR400BT
1925
595
645
69.6
0.65
88
2⁰C to 8⁰C
16⁰C to 32⁰C
R600a
444411318
PPGR400BT-LHH
1925
595
645
61.8
0.65
88
2⁰C to 8⁰C
16⁰C to 32⁰C
R600a
444411397
PPGR400BT-DWP
1925
595
645
82.6
0.65
88
2⁰C to 8⁰C
16⁰C to 32⁰C
R600a
444411395
PPGR400BT-DLK
1925
595
645
61.8
0.65
88
2⁰C to 8⁰C
16⁰C to 32⁰C
R600a

7
Product Specifications
cont.
Pharmacy Connect Range Refrigerators
SKU No
Model
Height
(mm)
Width
(mm)
Depth
Inc Handle
(mm)
Weight
(Kg)
Rating
(Amp)
Power
(W)
Temperature
Range
Ambient
Temperature
Refrigerant
444411319
PCSR158CT-UK
850
595
660
18.5
0.78
101
2⁰C to 8⁰C
16⁰C to 32⁰C
R600a
444411321
PCSR158CT-EU
850
595
660
18.5
0.78
101
2⁰C to 8⁰C
16⁰C to 32⁰C
R600a
444411323
PCSR158CT-DWP-UK
850
595
660
39.3
0.78
101
2⁰C to 8⁰C
16⁰C to 32⁰C
R600a
444411326
PCSR158CT-DLK-UK
850
595
660
18.5
0.78
101
2⁰C to 8⁰C
16⁰C to 32⁰C
R600a
444411320
PCGR158CT-UK
850
595
645
37.3
0.78
101
2⁰C to 8⁰C
16⁰C to 32⁰C
R600a
444411322
PCGR158CT-EU
850
595
645
37.3
0.78
101
2⁰C to 8⁰C
16⁰C to 32⁰C
R600a
444411324
PCGR158CT-DWP-UK
850
595
645
40.3
0.78
101
2⁰C to 8⁰C
16⁰C to 32⁰C
R600a
444411327
PCGR158CT-DLK-UK
850
595
645
37.3
0.78
101
2⁰C to 8⁰C
16⁰C to 32⁰C
R600a
444411328
PCSR310CT
1560
595
660
51.0
0.65
88
2⁰C to 8⁰C
16⁰C to 32⁰C
R600a
444411330
PCSR310CT-DLK
1560
595
660
51.0
0.65
88
2⁰C to 8⁰C
16⁰C to 32⁰C
R600a
444411332
PCSR310CT-DWP
1560
595
660
59.0
0.65
88
2⁰C to 8⁰C
16⁰C to 32⁰C
R600a
444411329
PCGR310CT
1560
595
645
61.0
0.65
88
2⁰C to 8⁰C
16⁰C to 32⁰C
R600a
444411331
PCGR310CT-DLK
1560
595
645
61.0
0.65
88
2⁰C to 8⁰C
16⁰C to 32⁰C
R600a
444411333
PCGR310CT-DWP
1560
595
645
69.6
0.65
88
2⁰C to 8⁰C
16⁰C to 32⁰C
R600a
444411335
PCSR400CT
1925
595
660
62.8
0.65
88
2⁰C to 8⁰C
16⁰C to 32⁰C
R600a
444411337
PCSR400CT-DLK
1925
595
660
62.8
0.65
88
2⁰C to 8⁰C
16⁰C to 32⁰C
R600a
444411339
PCSR400CT-DWP
1925
595
660
75.8
0.65
88
2⁰C to 8⁰C
16⁰C to 32⁰C
R600a
444411334
PCGR400CT
1925
595
645
70.6
0.65
88
2⁰C to 8⁰C
16⁰C to 32⁰C
R600a
444411336
PCGR400CT-DLK
1925
595
645
70.6
0.65
88
2⁰C to 8⁰C
16⁰C to 32⁰C
R600a
Laboratory Plus Refrigerators
SKU No
Model
Height
(mm)
Width
(mm)
Depth
Inc Handle
(mm)
Weight
(Kg)
Rating
(Amp)
Power
(W)
Temperature
Range
Ambient
Temperature
Refrigerant
444411358
LSFSR158BT-UK
850
595
660
17.9
0.78
101
2⁰C to 10⁰C
16⁰C to 32⁰C
R600a
444411359
LSFSR158BT-EU
850
595
660
17.9
0.78
101
2⁰C to 10⁰C
16⁰C to 32⁰C
R600a
444411360
LSFSR310BT-UK
1560
595
660
49.0
0.47
60
2⁰C to 10⁰C
16⁰C to 32⁰C
R600a
444411361
LSFSR310BT-UK-ATEX
1560
595
660
49.0
0.47
60
2⁰C to 10⁰C
16⁰C to 32⁰C
R600a
444411364
LSFSR400BT
1925
595
660
66.0
0.49
66
2⁰C to 10⁰C
16⁰C to 32⁰C
R600a
444411365
LSFSR400BT-ATEX
1925
595
660
66.0
0.49
66
2⁰C to 10⁰C
16⁰C to 32⁰C
R600a
Laboratory Plus Freezers
SKU No
Model
Height
(mm)
Width
(mm)
Depth
Inc Handle
(mm)
Weight
(Kg)
Rating
(Amp)
Power
(W)
Temperature
Range
Ambient
Temperature
Refrigerant
444411352
LSFSF98BT-UK
850
595
660
42.0
0.62
80
-18⁰C to -25⁰C
16⁰C to 32⁰C
R600a
444411353
LSFSF98BT-EU
850
595
660
42.0
0.62
80
-18⁰C to -25⁰C
16⁰C to 32⁰C
R600a
444411362
LSFSF242BT-UK
1560
595
660
65.0
0.86
88
-18⁰C to -25⁰C
16⁰C to 32⁰C
R600a
444411363
LSFSF242BT-UK-ATEX
1560
595
660
65.0
0.86
88
-18⁰C to -25⁰C
16⁰C to 32⁰C
R600a
444411366
LSFSF312BT
1925
595
660
84.1
1.35
130
-18⁰C to -25⁰C
16⁰C to 32⁰C
R600a
444411367
LSFSF312BT-ATEX
1925
595
660
84.1
1.35
130
-18⁰C to -25⁰C
16⁰C to 32⁰C
R600a

8
Product Specifications cont.
Laboratory Plus Fridge/Freezer Combi
SKU No
Model
Height
(mm)
Width
(mm)
Depth
Inc Handle
(mm)
Weight
(Kg)
Rating
(Amp)
Power
(W)
Temperature
Range
Ambient
Temperature
Refrigerant
444411352
LSFSF280BT-UK
TBC
595
660
TBC
TBC
TBC
Fr +2⁰C to +10⁰C
16⁰C to 32⁰C
R600a
Fz -18⁰C to -25⁰C
444411353
LSFSF280BT-EU
TBC
595
660
TBC
TBC
TBC
Fr +2⁰C to +10⁰C
16⁰C to 32⁰C
R600a
Fz -18⁰C to -25⁰C
Flammable Material Storage Units FMS
(Lab products only)
Conventional refrigerators are not suitable for storing flammable materials. Such units have components in
their electrical and refrigeration systems that can trigger explosions of flammable air-vapor mixtures inside
the unit.
FMS refrigerators/freezers are designed for use in locations which are not classified as hazardous by the Authority
Having Jurisdiction (AHJ). Under normal operating conditions, the build-up or presence of
flammable vapours will not occur in the environment outside the unit.
Flammable Materials Storage (FMS) refrigerators/freezers are designed for use in general laboratory
locations.
FMS units are NOT designed for use in Class I, Zone 0, or Zone1 applications, which require an Explosion-Proof
Refrigerator/Freezer. FMS units are designed, evaluated and comply with the ATEX Directive 2014/34/EU Annex
VIII. These units have an intrinsically safe (IS) barrier installed in the temperature probe circuit with no other
internal electrical components that could trigger an explosion or fire of flammable materials inside the unit. The
internal wall construction has been reviewed and is not a source for electrostatic build up due to the materials
used in construction.
The units bear the following ATEX marking.
These units are ideal for storing ethyl ether, acetone, alcohol, benzene, butane, gasoline, hexane, lacquer
solvent,
and naphtha along with many other potentially flammable materials.
Refrigerators, Freezers and Fridge Freezers for use in potentially explosive atmospheres, the internal refrigeration
chamber is classed as Zone 2, category 3 when the door is closed.
The external parts of the refrigerator are classed as safe area and as such do not need to comply with
requirements of the directive.

9
5: Product Details
5:1 Pharmacy Plus Refrigerators

10
Product Details
cont.
5:2 Laboratory Plus Refrigerators

11
Product Details
cont.
5:3 Laboratory Plus Freezers

12
Product Details
cont.
5:4 Laboratory Plus Refrigerator/Freezer Combi

13
6: Installation
Positioning and safely using the Refrigerator
WARNING: To reduce the risk of the unit
falling over, do not tip beyond 10 degrees
•Make sure the equipment is placed in a dry, well
ventilated site, away from heat sources.
•The equipment must be placed on a level
surface. If necessary, adjust the feet on the
product so the equipment remains level during
operation.
•The equipment should have enough clearance
around it to provide adequate ventilation –10cm at
each side, 6cm at the rear and 2.5cm at the top.
•Before ANY maintenance activity, pull the plug
out of the socket by gripping the plug, DO NOT
pull on the plug cord.
•DO NOT use extension cords.
•If the main power supply cord is damaged, it
should be replaced by a qualified service
engineer.
•DONOT attempt any repairs to the equipment
yourself (apart from those highlighted in the
Maintenance and Service Section). Repairs carried
out by someone without the relevant training are
putting their personal safety at risk and will
invalidate your warranty.
•Do not store explosive substances such as
aerosol cans with a flammable propellant in this
equipment.
WARNING: This equipment is only to be
operated by authorized personnel or
personnel who have correct knowledge on
how the equipment operates.
•Use this product only in the way described in the
product literature and in this manual. Before
using it, verify that this product is suitable for its
intended use. If the equipment is used in a
manner not specified by the manufacturer, the
protection provided by the equipmentmay be
impaired.
•DO NOT modify system components,
especially the controller. Use LEC Medical
exact replacement equipment or parts. Before
use, confirm that the product has not been
altered in anyway
•Your unit must be properly grounded in
conformity with national and local electrical
codes. Never connect the unit to overloaded
power sources.
•Disconnect the unit from all power sources
before cleaning, troubleshooting, or
performing other maintenance on the
product or its controls.
Transporting and Moving
the Refrigerator
The refrigerator must always be moved in the vertical
position. The cabinet must not be tilted any more than
40°. If the cabinet is tilted more than 40°, the power
supply must not be connected until the equipment has
stood upright for at least 24 hours. Necessary equipment
to move the product is to be arranged by the user.
Electrical Connection
The equipment is intended for connection to alternating
current. The connection values for voltage (V) and
frequency (Hz) are declared on the name plate in the
cabinet. Power must be connected via a wall socket with
a switch. It is strongly recommended that the wall socket
is easily accessible. All earthing requirements stipulated
by the local electricity authority.The cabinet plug and wall
socket should give correct earthing. If in doubt, contact
your local supplier or an authorized electrician.
THISEQUIPMENTMUSTBE EARTHED.
If thesupply cord is damaged,it must be replaced by the
manufacturer, its service agent or similarly qualified
persons in order to avoid a hazard.
The flexible cord (mains lead) fitted to this equipment
has three cores for use with a 3-pin 13-amp plug. If a
BS 1363 (13-amp) fused plug is used it should be fitted
with a 13-amp fuse. The cores in the mains lead are
coloured in accordance with the following code:
GREEN AND YELLOW: EARTH
BLUE:NEUTRAL
BROWN: LIVE
These colours might not correspond with the
colour markings identifying the terminals in your
plug.

14
Electrical Connections
Note:
First Connection to the mains.
The equipment provides information about the higher temperature (Hi alarm) till the moment of cooling.
The alarm is signalized by a sound signal and “Hi” caption on the display.
To mute the alarm touch anywhere on the front surface of the controller.
Until the moment of cooling, the alarm is repeated every 10 minutes. Such an operating mode is
normal until the required temperature settings are reached.
5
3
4
1
2
1: Green Yellow
2: Blue
3: Brown
4: 13 Amp Fuse
5: Cord Clamp

15
7: Before Switching On
Thank you for purchasing this LEC Pharmacy/Laboratory Refrigerator
Before you first use this pharmacy refrigerator, please carry out the following actions: -
•Check that the refrigerator has not been damaged in any way during transportation.
•If any damage is found it must be reported to your local dealer immediately.
•Ensure all packaging has been removed, including cardboard, polystyrene and any tape used to hold
shelves in place for transportation.
•The refrigerator has been cleaned prior to dispatch; however, we advise that it should be cleaned
using lukewarm water containing a mild detergent and a soft cloth prior to switching on.
•This equipment is not intended for use by persons (including children) with reduced physical,
sensory, mental capabilities, or lack of experience and knowledge, unless they have been given
supervision or instruction concerning use of the equipment by a person responsible for their
safety.
•Ensure the fridge/freezer is level by adjusting the two feet at the front of the unit.
For the larger volume units 310L, 400L, 242L, 312L ensure the third foot is fully up before
levelling the unit.
When the unit is level adjust the third foot, so it touches the floor.
•To activate the battery backup, install the fuse as shown here. There are two fuses in the
documents bag.
•We recommend that the refrigerator should be left in an upright position preferably in the place
where it will be used for 24 hours prior to switching on for the first time.

16
8: Operation
IJ Controller Overview
Symbol
Description
Function
A
Air Temperature Displayed
Indicates that the AIR temperature is being displayed as selected
by the AIR/LOAD Button.
Scroll Up Arrow
Button to scroll up through menus and values.
Toggle Air/Load Display
Switches between Air and Load temperatures.
Navi Button (Enter)
Used to confirm actions and input values and to unlock the
controller by keeping pressed for 3 seconds.
Unit ON/OFF
Press for 3 seconds the unit will swich off. The controller will flash
between current selected temperature A or L and “OFF”.
Scroll Down Arrow
Button to scroll down through menus and values.
L
Load Temperature Displayed
Indicates that the LOAD temperature is being displayed as
selected by the AIR/LOAD Button.
Main Display
Temperatures, alarms, menus, parameter values are displayed
here.
Controller in Alarm Condition
If this symbol is displayed the controller is in an alarm condition.
It will clear when the alarm/fault is cleared.
Evaporator Fan Running
Indicates when the evaporator fan is running under the intelligent
fan control system.
Display Minimum Temperature
After unlocking the controller, pressing this button will display the
minimum recorded temperature since the last reset.
Reset Air & Load Temperature
Used to access the reset minimum and maximum temperature
function. Both Air and Load Temperatures will be reset.
Display Maximum Temperature
After unlocking the controller, pressing this button will display the
maximum recorded temperature since the last reset.
Compressor Running
Indicates when the compressor is running. Will flash if the
controller is waiting to run the compressor.
Table **
Scroll Up Arrow
Scroll Down Arrow
Load Temp Displayed
Main Display
Compressor Running
Air Temp Displayed
Evaporator Fan Running
Controller in alarm Condition
Reset Air & Load Temp
Display Max Temp
Display Min Temp
Toggle Air/Load Display
Navi Button (Enter)
Unit ON/OFF

17
9: Basic Operations using the LEC Medical App
9:1 Download and install the LEC Medical App
LEC Medical recommends using the dedicated LEC Medical App to access the data recorded in the controller,
scan the appropriate QR code to Download the LEC Medical App.
Alternatively open the App Store/Play Store and search for Lec Medical.
Install and open the app connect to the appliance.
9:2 Connecting to an appliance
Open the app the first window will list of all available appliances, for a first-time connection this will be the
controller serial number. connect to the appliance controller by pressing Bluetooth
Select the required appliance - when connected the home page will display as shown on the next page.
LEC-
medical
LEC-
medical

18
9:3 App Home Page
APP Home Page and controller displays as shown below, we recommend changing the Connected to:
Carel_00000***** to a name of your choice see page **.
9:6 Accessing Min/Max temperatures
The Min/Max temperatures displayed are the highest and lowest recorded Air and Load temperatures since
the LAST RESET, the date and time of the last reset is displayed below LAST RESET, after RESET the current Air
and Load temperatures will be displayed.
NOTE: After pressing RESET the Min/Max temperatures are stored in the controller for up to 3 months on
FIFO bases. They can be retrieved and downloaded at any time.
Current Load Temperature
Current Air Temperature
Control Temperature
Min/Max Reset
Appliance Name
Min/Max Temperatures
since last reset
For other app functions
see section 10:
Controller will flash bLE when
connected to the LEC Medical App

19
9:5 Re-Setting Min/Max Temperatures using the APP
To re-set the Min/Max Temperatures simply press the Reset Button.
Both Air and Load Temperatures will be reset as a shown here.
9:7 Re-Naming the Appliance
LEC Medical highly recommends renaming the appliance to a name of your choice, particularly if more the
one LEC Medical Bluetooth enabled appliance is present.
To rename the Appliance press the WHITE TEXT button next to “Connected to:” this is usually the controller
serial number then enter the appliance name (Customer choice).
Press OK and the App will display the Appliance name as shown.
Carel_0000029906
Example only
PPGR158BT
Example only
This manual suits for next models
128
Table of contents