Ledj LEDJ186 User manual

Order code: LEDJ186
UV 50W COB Flood
1 x 50W UV COB LED
User Manual
Optional
IR remote
Order ref:
LEDJ90E

www.prolight.co.uk UV 50W COB Flood User Manual
2
Safety advice
WARNING
FOR YOUR OWN SAFETY, PLEASE READ THIS USER MANUAL
CAREFULLY BEFORE YOUR INITIAL START-UP!
• Beforeyourinitialstart-up,pleasemakesurethatthereisnodamagecausedduringtransportation.
• Shouldtherebeanydamage,consultyourdealeranddonotusetheequipment.
• Tomaintaintheequipmentingoodworkingconditionandtoensuresafeoperation,itisnecessary
fortheusertofollowthesafetyinstructionsandwarningnoteswritteninthismanual.
• Pleasenotethatdamagescausedbyusermodicationstothisequipmentarenotsubjecttowarranty.
IMPORTANT:
The manufacturer will not accept liability for any resulting damages caused by the non-observance
of this manual or any unauthorised modication to the equipment.
OPERATING DETERMINATIONS
Ifthisequipmentisoperatedinanyotherway,thanthosedescribedinthismanual,theproductmaysufferdamageand
thewarrantybecomesvoid.Incorrectoperationmayleadtodangere.g:short-circuit,burnsandelectricshocksetc.
Donotendangeryourownsafetyandthesafetyofothers!
Incorrectinstallationorusecancauseseriousdamagetopeopleand/orproperty.
• Neverletthepowercablecomeintocontactwithother
cables.Handlethepowercableandallmainsvoltage
connectionswithparticularcaution!
• Neverremovewarningorinformativelabelsfromtheunit.
• Donotopentheequipmentanddonotmodifytheunit.
• Donotconnectthisequipmenttoadimmerpack.
• Donotswitchtheequipmentonandoffinshortintervals,
asthiswillreducethesystem’slife.
• Onlyusetheequipmentindoors.
• Donotexposetoammablesources,liquidsorgases.
• Alwaysdisconnectthepowerfromthemainswhen
equipmentisnotinuseorbeforecleaning!Onlyhandle
thepower-cablebytheplug.Neverpullouttheplugby
pullingthepower-cable.
• Makesurethattheavailablevoltageisbetween
110~240V,50/60Hz.
• Makesurethatthepowercableisnevercrimpedor
damaged.Checktheequipmentandthepowercable
periodically.
• Iftheequipmentisdroppedordamaged,disconnectthe
mainspowersupplyimmediatelyandhaveaqualied
engineerinspecttheequipmentbeforeoperatingagain.
• Iftheequipmenthasbeenexposedtodrastic
temperatureuctuation(e.g.aftertransportation),
donotconnectpowerorswitchitonimmediately.
Thearisingcondensationmightdamagetheequipment.
Leavetheequipmentswitchedoffuntilithasreached
roomtemperature.
• Ifyourproductfailstofunctioncorrectly,stopuse
immediately.Packtheunitsecurely(preferablyinthe
originalpackingmaterial),andreturnittoyourProLight
dealerforservice.
• Onlyusefusesofsametypeandrating.
• Repairs,servicingandpowerconnectionmustonlybe
carriedoutbyaqualiedtechnician.THISUNITCONTAINS
NOUSERSERVICEABLEPARTS.
• WARRANTY:Oneyearfromdateofpurchase.
CAUTION!
KEEP THIS EQUIPMENT
AWAY FROM RAIN,
MOISTURE AND LIQUIDS
CAUTION!
TAKE CARE USING
THIS EQUIPMENT!
HIGH VOLTAGE-RISK
OF ELECTRIC SHOCK!!

www.prolight.co.uk UV 50W COB Flood User Manual
3
Product overview & technical specications
Thispowerful50WUVFloodwillllavarietyofvenueswithanoutstandingUVglow.Theseunitshavearugged,
metalhousingandmeasureonly130mmindepthforeasytransportationandinstallation.
Theyarealsoconvectioncooledforsilentoperationandfeaturea85°beamangle.The4pushbuttonLED
menuorincludedIRremotealloweasyaccesstothefunctionsincludingDMX,master/slave,soundactive
andstandalonemodes.
•1x50WUVCOBLED
•Beamangle:85°
•1.1kHzrefreshrate
•DMXchannels:1or2selectable
•Standalone,soundactiveandmaster/slavemodes
•0-100%dimmingwithvariablestrobe
•Bracketallowsformultipleriggingand
oorstandingapplications
•Rearcontrolpanelandrubberfeetallowthe
paneltositatontheoorforuplighting
•4pushbuttonmenuwithLEDdisplay
•SideentryXLRandpowerconnections
•IECpowerin/outsockets
•3-pinXLRin/outsockets
•Fancooled
•SuppliedwithIRremote(LEDJ90E)
UV Spectra Batten
Specications UV 50W COB Flood
Powerconsumption 56W
Powersupply 110~240V,50/60Hz
Fuse F1A250V
Dimensions 284x248x130mm
Weight 2.8kg
Ordercode LEDJ186
248mm 130mm
284mm

www.prolight.co.uk UV 50W COB Flood User Manual
4
01-Bracket
02-Brackettighteningknobs
03-Earthpoint
04-LEDdisplay
05-Functionbuttons
06-DMXinputsocket
07-DMXoutputsocket
08-IECpowerinsocket
09-IECpoweroutsocket
10-FuseF1A250V
0810 0903 07 06
ENTER DOWN
MODE
UP
POWER IN POWER OUT DMX OUT DMX IN
www.prolight.co.uk
UV
50W COB FLOOD
02
04
05
01
PUSH
Technical specications
Inthebox:1 x xture,
1 x IR remote,
1 x power cable &
1 x user manual

www.prolight.co.uk UV 50W COB Flood User Manual
5
Operating instructions
DMX channel mode:
ToaccesstheDMXchannelmode,pressthe“MODE”buttonontherearoftheunittoshowA001
ontheLEDdisplay.Nowpressthe“ENTER”buttonandusethe“UP”and“DOWN”buttonstosetthe
desiredDMXaddress.Nowpressthe“ENTER”buttontochooseoneofthe1or2DMXchannelmodes
usingthe“UP”and“DOWN”buttons,andpressthe“ENTER”usethe“UP”and“DOWN”buttonstoset
whattheunitshoulddoifitlosesDMXsignal.
bLC-TheunitwillblackoutifDMXsignalislost.
Soun-TheunitwillgointosoundactivemodeifDMXsignalislost.
HoLd-TheunitwillholdthelastDMXcommandifDMXsignalislost.
Toexitoutofanyoftheaboveoptions,pressthe“MODE”button.
Static mode:
Toaccessstaticmodepress“ENTER”untilthedisplayshowsC-00ontheLEDdisplay.
Toadjustthebrightnessusethe“UP”and“DOWN”buttonstoselectbetweenC-00~C-99.
Pressthe“ENTER”buttontoconrmthesetting.Nowusethe“UP”and“DOWN”buttonstoadjustthe
ashspeedbyselectingbetweenF-00~F-99.Pressthe“ENTER”buttontoconrmthesetting.
Toexitoutofanyoftheaboveoptions,pressthe“MODE”button.
Slave mode:
Pressthe“MODE”buttonontherearoftheunittoshowSLAUontheLEDdisplayandpressthe
“ENTER”buttontoconrmthesetting.Theunitwillnowruninsequencewiththemasterunit.
Toexitoutofanyoftheaboveoptions,pressthe“MODE”button.
PleaseensurethatallslaveunitsaresettothesameDMXchannelmodeasthemasterunit.
Sound active mode:
Toaccessthesoundactivemode,pressthe“MODE”buttonontherearoftheunittoshowSU00
ontheLEDdisplay.Nowpressthe“ENTER”buttonandusethe“UP”and“DOWN”buttonstosetthe
soundsensitivitylevelfromSU.00~SU.99andpressthe“ENTER”buttontoconrmthesetting.
Value: 00 - 99 (00 = low, 99 = high)
Toexitoutofanyoftheaboveoptions,pressthe“MODE”button.
Channel Value Function
1000-255 Masterdimmer(0-100%)
Channel Value Function
1000-255 Masterdimmer(0-100%)
2000-255 Flashspeed(slowtofast)
1 channel mode: 2 channel mode:
Staticmode C-00~C-99Brightness(0-100%)
F-00~F-99Flashspeed(slow-fast)
Slavemode SLAV
Soundactivemode SU00~SU99
Menusystem
DMXmode 1CH,2CH
Addresssetting A001~A512
IRfunction Iron -IROn
IroF -IROff

www.prolight.co.uk UV 50W COB Flood User Manual
6
Operating instructions & DMX setup
Included IR remote functions:
Button functions:
DMX address examples:
TosettheDMXaddress;
• Pressthe“S”button,theLEDxturewillilluminate
infull,youcannowstarttosettheDMXaddress
• Selecttherequired3digitDMXaddress
(eg001or136or275)theunitwillthenash
toconrmtheaddresshasbeenset
• Nowpressthe“DMXMODE”buttontosavethenewaddressintothememory
Important notes:
• SettheDMXaddressoneachxturebeforepluggingintotheDMXcontroller
• TheIRremotecannotbeusedwhenthexture(s)arebeingcontrolledwithaDMXcontroller
• ThemaximumIRtransmitterdistanceis10m-PleasemakesurethatyouhavetheIRremote
aimeddirectlyatthefrontpanelofeachxturetobeprogrammed
• Ifyoudonotpressthe“DMXMODE”buttonafteryouhavechangedtheDMXaddresswhenyou
powerdownthextureitwilllosetheaddressyouhaveset
Setting the DMX address:
TheDMXmodeenablestheuseofauniversalDMXcontroller.Eachxturerequiresa“startaddress”
from1-512.Axturerequiringoneormorechannelsforcontrolbeginstoreadthedataonthechannel
indicatedbythestartaddress.Forexample,axturethatoccupiesoruses7channelsofDMXandwas
addressedtostartonDMXchannel100,wouldreaddatafromchannels:100,101,102,103,104,105
and106.Chooseastartaddresssothatthechannelsuseddonotoverlap.E.g.thenextunitinthe
chainstartsat107.
01-Blackout
02-TosetthebrightnessoftheLEDeither
select20%,50%or100%oralternatively
youcanusethe‘+’and‘-’buttons
03-Flashoff
04-TosettheashspeedoftheLEDeither
select20%,50%or100%oralternatively
youcanusethe‘+’and‘-’buttons
05-SetstheLEDxtureintoDMXmode
06-SetstheLEDxtureintosoundactivemode
07-SetstheLEDxtureintoslavemode
08-SetstheDMXaddressfortheLEDxture
1 2 3
4 5 6 0
+
_
7 8 9
D SL S
OFF 20% 50% 100%
SA
STROBE
OFF 20% 50% 100%
DIMMING
SLAVE SET ADDRSOUND ACTIVEDMX MODE
01
04
02
07
06
05 08
Included
IR remote
Order code:
LEDJ90E
03

www.prolight.co.uk UV 50W COB Flood User Manual
7
DMX 512:
DMX(DigitalMultiplex)isauniversalprotocolusedasaformofcommunicationbetweenintelligent
xturesandcontrollers.ADMXcontrollersendsDMXdatainstructionsformthecontrollertothexture.
DMXdataissentasserialdatathattravelsfromxturetoxtureviatheDATA“IN”andDATA“OUT”
XLRterminalslocatedonallDMXxtures(mostcontrollersonlyhaveadata“out”terminal).
DMX linking:
DMXisalanguageallowingallmakesandmodelsofdifferentmanufacturestobelinkedtogether
andoperatefromasinglecontroller,aslongasallxturesandthecontrollerareDMXcompliant.
ToensureproperDMXdatatransmission,whenusingseveralDMXxturestrytousetheshortest
cablepathpossible.TheorderinwhichxturesareconnectedinaDMXlinedoesnotinuencethe
DMXaddressing.Forexample;axtureassignedtoaDMXaddressof1maybeplacedanywherein
aDMXline,atthebeginning,attheend,oranywhereinthemiddle.Whenaxtureisassigneda
DMXaddressof1,theDMXcontrollerknowstosendDATAassignedtoaddress1tothatunit,
nomatterwhereitislocatedintheDMXchain.
DATA cable (DMX cable) requirements (for DMX operation):
ThisxturecanbecontrolledviaDMX-512protocol.TheDMXaddressissetonthebackoftheunit.
YourunitandyourDMXcontrollerrequireastandard3-pinXLRconnectorfordatainput/output,
seeimagebelow.
Also remember that DMX cable must be daisy chained and cannot be split.
Notice:
Besuretofollowthediagramsbelowwhenmakingyourowncables.Donotconnectthecables
shieldconductortothegroundlugorallowtheshieldconductortocomeincontactwiththeXLRs
outercasing.Groundingtheshieldcouldcauseashortcircuitanderraticbehaviour.
DMX setup
FurtherDMXcablescanbe
purchasedfromallgoodsound
andlightingsuppliersor
ProLightConceptsdealers.
Pleasequote:
CABL10 – 2m
CABL11 – 5m
CABL12 – 10m

www.prolight.co.uk UV 50W COB Flood User Manual
8
Special note:
Line termination:
Whenlongerrunsofcableareused,
youmayneedtouseaterminatoron
thelastunittoavoiderraticbehaviour.
Using a cable terminator will decrease
the possibilities of erratic behaviour.
(3-pin - Order ref: CABL9O, 5-pin - Order ref: CABL89)
5-pin XLR DMX connectors:
Somemanufacturesuse5-pinXLRconnectorsfordatatransmissioninplaceof3-pin.5-pinXLRxtures
maybeimplementedina3-pinXLRDMXline.Wheninsertingstandard5-pinXLRconnectorsintoa
3-pinlineacableadaptormustbeused.Thediagrambelowdetailsthecorrectcableconversion.
Terminationreducessignaltransmission
problemsandinterferance.itisalways
advisabletoconnectaDMXterminal,
(resistance120Ohm1/4W)betweenpin2
(DMX-)andpin3(DMX+)ofthelastxture.
5-pin XLR (socket)
Pin 1: GND (screen)
Pin 2: Signal (-)
Pin 3: Signal (+)
Pin 4: N/C
Pin 5: N/C
3-pin XLR (socket)
Pin 1: GND (screen)
Pin 2: Signal (-)
Pin 3: Signal (+)
3-pin XLR (socket)
Pin 1: GND (screen)
Pin 2: Signal (-)
Pin 3: Signal (+)
5-pin XLR (socket)
Pin 1: GND (screen)
Pin 2: Signal (-)
Pin 3: Signal (+)
Pin 4: N/C
Pin 5: N/C
DMX setup & WEEE notice
Correct Disposal of this Product
(Waste Electrical & Electronic Equipment)
(Applicable in the European Union and other European countries
with separate collection systems)
Thismarkingshownontheproductoritsliterature,indicatesthatitshouldnotbedisposedof
withotherhouseholdwastesattheendofitsworkinglife.Topreventpossibleharmtothe
environmentorhumanhealthfromuncontrolledwastedisposal,pleaseseparatethisfromother
typesofwastesandrecycleitresponsiblytopromotethesustainablereuseofmaterialresources.
Householdusersshouldcontacteithertheretailerwheretheypurchasedthisproduct,ortheir
localgovernmentofce,fordetailsofwhereandhowtheycantakethisitemforenvironmentally
saferecycling.
Businessusersshouldcontacttheirsupplierandcheckthetermsandconditionsofthe
purchasecontract.Thisproductshouldnotbemixedwithothercommercialwastesfordisposal.
This manual suits for next models
1
Table of contents
Other Ledj Light Fixture manuals
Popular Light Fixture manuals by other brands

Sea gull lighting
Sea gull lighting Moffet Street Wall 4134501 installation instructions

ADB
ADB ALS-150 instruction manual

Xoop Lighting
Xoop Lighting P180 user manual

GE
GE 89003 quick start guide

Ehrgeiz
Ehrgeiz CONTOUR AMBIENCE WASH 12 ZOOM instruction manual

Cooper Lighting
Cooper Lighting PM138cb Specification sheet