Table 1 Server features and specifications (continued)
• In 2.5" system, two internal SAS
cable connecting SAS RAID
controller to SAS hard drive
back lane. One ty e of
back lanes will be used to su ort
eight 2.5" hot-swa HDDs. In
addition, the system will use 2
ty es of back lanes to su ort
sixteen 2.5" hot-swa HDDs
• In 3.5" system, two internal SAS
cable is required to su ort eight
3.5" hot-swa HDDs with the
required back lane
PCI and PCI-X expansion slots:
• Six PCI-e ex ansion slots on the
system board
– Slot 1: PCI Ex ress 3.0 x8 (x8
wired); full-height, half-length
(requires second rocessor)
– Slot 2: PCI Ex ress 3.0 x8 (x8
wired) ; full-height, full-length
– Slot 3: PCI Ex ress 3.0 x8 (x4
wired); full-height, half-length
– Slot 4: PCI Ex ress 3.0 x16 (x8
wired); full-height, full-length
– Slot 5: Gen2 PCI Ex ress x4 (x1
wired); full-height, half-length
– Slot 6: Gen2 PCI Ex ress x8 (x4
wired); full-height, half-length,
has PCI-X ca ability by using a
PCI-e (of Lenovo System x3500
M4 Ty e 7383) to PCI-X
converter kit
• One PCI-X Slot (o tional): 64-bit/
133MHz
– Maximum altitude: 3050 m
(10,000 ft) & 5°C - 28°C (41°F -
82°F)
– Maximum rate of tem erature
change: 5°C/hr (41°F/hr) for
ta e drive, 20°C/hr (68°F/hr) for
HDDs
• Power off:
– Tem erature: 5°C to 45°C (41°F
- 113°F)
– Relative humidity: 8% - 85%
– Maximum dew oint: 27°C
(80.6°F)
• Storage (non-o erating)
– Tem erature: 1°C to 60°C
(33.8°F - 140°F)
– Altitude: 3050 m (10,000 ft)
– Relative humidity: 5% - 80%
– Maximum dew oint: 29°C
(84.2°F)
• Shi ment (non-o erating)
– Tem erature: -40°C to 60°C
(-40°F - 140°F)
– Altitude: 10,700 m (35,105 ft)
– Relative humidity: 5% - 100%
– Maximum dew oint: 29°C
(84.2°F)
• Particulate contamination:
Attention: Airborne articulates
and reactive gases acting alone or
in combination with other
environmental factors such as
humidity or tem erature might
ose a risk to the server. For
information about the limits for
articulates and gases, see
“Particulate contamination” on
age 799.
• Onboard Intel Powerville Gigabit
Ethernet controller with Wake on
LAN su ort. The controller
rovides u to four orts when the
o tional Feature on Demand (FoD)
feature is activated.
• Combine "Intel PCH SAS/SATA
RAID controller which su orts for
RAID levels 0, 1 and 10 with SW
RAID controller - ServeRAID C105
• Light ath diagnostics
• Eight Universal Serial Bus (USB)
2.0 orts:
– Two on the front of the chassis
– Four on the rear of the chassis
– Two internal USB orts: one is
for o tion USB flash device with
embedded hy ervisor, one is
for o tion USB ta e drive
• One serial connector
• One D-Sub VGA connector
Power supply:
• One fixed 460-watt ower su ly
– None su ort AEM function
– None su ort gra hic card
– For two micro rocessors
installed, the maximum HDD is
u to 4 and the maximum PCIe
cards is u to 3
• U to two hot-swa ower su ly
for redundant su ly
– 550-watt ac
Notes:
1. None su ort gra hic card
Electrical input:
• Sine-wave in ut (50 - 60 Hz)
required
• In ut voltage automatically
selected
• In ut voltage low range:
– Minimum: 100 V ac
– Maximum: 127 V ac
• In ut voltage high range:
– Minimum: 200 V ac
– Maximum: 240 V ac
• In ut kilovolt-am eres (kVA),
a roximately:
– Minimum: 0.12 kVA
– Maximum: 0.9 kVA
Acoustical noise emissions:
• Non-redundant ower system,
Idle: 5.5 bels, o erating: 5.8 bels
• Redundant ower system, Idle: 6.0
bels, o erating: 6.3 bels
Chassis
• 4U standing and rack mountable
mechanical
• Physical dimensions: 425 mm
(Height) x 176 mm (Width) x 635
mm (De th)
• Weight a roximately: 29.7 kg
(65.43 lb) when fully configured or
20 kg (42 lb) minimum
Cha ter 1.The Lenovo System x3300 M4 Ty e 7382 server 7