Lenze MP 800 DVI User manual

BA_MP9000DVI
.NpW
Ä.NpWä
Operating Instructions
Industrial PC
MP 800 DVI ... MP 9000 DVI
Monitor Panel (Embedded Line)
L−force Controls
-
F3
Fail
Power
F1
+
F2
Status
Q+R
F1 F2 F5
-S T
F3 F4
@\Z
F11F10
YX
F9F8 F12
WVU
F7F6
Shift
Alpha
Bs
Space
Enter
EscDelIns
MenuAltCtrl
Home
1
I
0
M
4
E
7
A
Pg Dn
*
3
J K L
/
,
N O P
Pg Up
End
Status
Power
Fail
2
.
+6
F G H
-
9
B C D
5
8
"
(
§
&
)
=
/
$
!
>/
*
-
+
,
|
54 6
87 9
1 2 3
<
0
-
+
Alt Strg
*
+
T
F4
€
D
EWQ
XY
SA
@
F3F1 F2
R
VC
F
F5
G H J
-
_
Ä
F9F8F6 F7 F10
OI P ÜUZ
Ö
;
,:
M
μ
.
LK
NB
Space
Enter
\
?
ß
~
F12
Esc
F11
Pos 1
Einfg
Ende
Entf
Bs
Alt Gr
Fail
Status
Power
Bild
Bild
S13
S14
S11
S10
S12
S6
S7
F3F2
+-
F4
Status
Power
Fail F1
Esc Enter
F11 F12F6F5 F7 F8 F9 F10
S1
S4
S2
S3
S5
S8
S9

Please read these instructions before you start working!
Follow the enclosed safety instructions.

Contents i
3
BA_MP9000DVI DE 4.0
1 About this documentation 5. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1.1 Document history 6. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1.2 Conventions used 7. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1.3 Notes used 8. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2 Safety instructions 9. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2.1 General safety information 9. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2.2 Product−specific safety instructions 11. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
2.3 Safety instructions for the installation according to UL 12. . . . . . . . . . . . . . . . . . . . .
3 Product description 14. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3.1 Scope of supply 14. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3.2 Application as directed 15. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3.3 Device features 15. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3.4 Identification 18. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3.5 Controls and displays 19. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4 Technical data 20. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.1 General data and operating conditions 20. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.2 Electrical data 22. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4.3 Mechanical data 22. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5 Mechanical installation 24. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5.1 Important notes 24. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5.3 Mounting cutout 25. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5.4 Mounting steps 26. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5.4.1 MP 1000(s) DVI / MP 1050(s) DVI 26. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
5.4.2 MP 2xxx DVI / MP 5xxx DVI / MP 9xxx DVI 27. . . . . . . . . . . . . . . . . . . . . . . .
6 Electrical installation 28. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6.1 Important notes 28. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6.2 Wiring according to EMC 29. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6.5 Connecting the supply and peripheral devices 30. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6.5.1 Terminal diagram supply 30. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6.5.2 24 V connection 30. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6.5.3 DVI interface 31. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6.5.4 USB interface 31. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6.5.5 USB interface on the front face (option) 31. . . . . . . . . . . . . . . . . . . . . . . . . .

Contentsi
4 BA_MP9000DVI DE 4.0
7 Operation 32. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
7.1 Important notes 32. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
7.3 Controls and displays 33. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
7.3.1 Monitor Panel MP 800 DVI / MP 1000 DVI / MP 1000s DVI / MP 2000 DVI /
MP 5000 DVI / MP 9000 DVI 33. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
7.3.2 Monitor Panel MP 5020 DVI 34. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
7.3.3 Monitor Panel MP 1050 DVI / MP 1050s DVI / MP 2050 DVI /
MP 5050 DVI 35. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
7.3.4 Monitor Panel MP 5070 DVI 36. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
8 Maintenance 37. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
8.1 Regular checks 37. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
8.2 Cleaning 38. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
8.5 Repair 39. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
8.5.1 Removing and mounting the housing 39. . . . . . . . . . . . . . . . . . . . . . . . . . . .
8.5.2 Fuse change 40. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
9 Index 41. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

About this documentation 1
5
BA_MP9000DVI DE 4.0
0Fig. 0Tab. 0
1 About this documentation
Contents
This documentation provides you with information about the intended use of the monitor
panel.
The present manual is part of the "Controller−based automation" or "PC−based
automation" manual collection which you can find on the DVDs of the same name.
Target group
This documentation is directed at qualified skilled personnel according to IEC 60364.
Qualified skilled personnel are persons who have the required qualifications to carry out
all activities involved in installing, mounting, commissioning, and operating the product.
Tip!
Information and auxiliary devices related to the Lenze products can be found
in the download area at
http://www.Lenze.com
Validity
These instructions are valid for
ƒMP 800 DVI
ƒMP 1000 DVI, MP 1000s DVI
ƒMP 1050 DVI, MP 1050s DVI
ƒMP 2000 DVI
ƒMP 2050 DVI
ƒMP 5000 DVI
ƒMP 5020 DVI
ƒMP 5050 DVI
ƒMP 5070 DVI
ƒMP 9000 DVI

About this documentation
Document history
1
6 BA_MP9000DVI DE 4.0
1.1 Document history
Material number Version Description
.NpW 4.0 02/2014 TD06 New:
lUL notes (French language)
lNotes RJ45 cable laying
13433085 3.0 03/2013 TD29 General revision
13392303 2.0 11/2011 TD29 Supplement of the note concerning the protection
against direct solar radiation, as well as chapter
"Repair"
13385511 1.0 07/2011 TD29 First edition

About this documentation
Conventions used
1
7
BA_MP9000DVI DE 4.0
1.2 Conventions used
This documentation uses the following conventions to distinguish between different
types of information:
Type of information Identification Examples/notes
Spelling of numbers
Decimal separator Point In general, the decimal point is used.
For instance: 1234.56
Warnings
UL warnings Given in English and French
UR warnings
Text
Program name » « PC software
For example: »Engineer«, »Global Drive
Control« (GDC)
Icons
Page reference Reference to another page with additional
information
For instance: 16 = see page 16
Documentation reference Reference to another documentation with
additional information
For example: EDKxxx = see
documentation EDKxxx

About this documentation
Notes used
1
8 BA_MP9000DVI DE 4.0
1.3 Notes used
The following pictographs and signal words are used in this documentation to indicate
dangers and important information:
Safety instructions
Structure of safety instructions:
Danger!
(characterises the type and severity of danger)
Note
(describes the danger and gives information about how to prevent dangerous
situations)
Pictograph and signal word Meaning
Danger!
Danger of personal injury through dangerous electrical voltage.
Reference to an imminent danger that may result in death or
serious personal injury if the corresponding measures are not
taken.
Danger!
Danger of personal injury through a general source of danger.
Reference to an imminent danger that may result in death or
serious personal injury if the corresponding measures are not
taken.
Stop!
Danger of property damage.
Reference to a possible danger that may result in property
damage if the corresponding measures are not taken.
Application notes
Pictograph and signal word Meaning
Note! Important note to ensure troublefree operation
Tip! Useful tip for simple handling
Reference to another documentation
Special safety instructions and application notes
Pictograph and signal word Meaning
Warnings! Safety note or application note for the operation according to
UL or CSA requirements.
The measures are required to meet the requirements according
to UL or CSA.
Warnings!

Safety instructions
General safety information
2
9
BA_MP9000DVI DE 4.0
2 Safety instructions
2.1 General safety information
Scope
The following general safety instructions apply to all Lenze drive and automation
components.
The product−specific safety and application notes given in this documentation must be
observed!
For your own safety
Danger!
Disregarding the following basic safety measures may lead to severe personal
injury and damage to material assets!
ƒLenze drive and automation components ...
... must only be used for the intended purpose.
... must never be operated if damaged.
... must never be subjected to technical modifications.
... must never be operated unless completely assembled.
... must never be operated without the covers/guards.
... can − depending on their degree of protection − have live, movable or rotating parts
during or after operation. Surfaces can be hot.
ƒFor Lenze drive and automation components ...
... only use approved accessories.
... only use original manufacturer spare parts.
ƒAll specifications of the corresponding enclosed documentation must be observed.
This is vital for a safe and trouble−free operation and for achieving the specified product
features.
The procedural notes and circuit details provided in this document are proposals which
the user must check for suitability for his application. The manufacturer does not
accept any liability for the suitability of the specified procedures and circuit proposals.
ƒOnly qualified skilled personnel are permitted to work with or on Lenze drive and
automation components.
According to IEC 60364 or CENELEC HD 384, these are persons ...
... who are familiar with the installation, assembly, commissioning and operation of
the product,
... possess the appropriate qualifications for their work,
... and are acquainted with and can apply all the accident prevent regulations, directives
and laws applicable at the place of use.

Safety instructions
General safety information
2
10 BA_MP9000DVI DE 4.0
Transport, storage
ƒTransport and storage in a dry, low−vibration environment without aggressive
atmosphere; preferably in the packaging provided by the manufacturer.
– Protect against dust and shocks.
– Comply with climatic conditions according to the technical data.
Mechanical installation
ƒInstall the product according to the regulations of the corresponding
documentation. In particular observe the section "Operating conditions" in the
chapter "Technical data".
ƒProvide for a careful handling and avoid mechanical overload. During handling
neither bend components, nor change the insulation distances.
ƒThe product contains electrostatic sensitive devices which can easily be damaged by
short circuit or static discharge (ESD). Thus, electronic components and contacts
must not be touched unless ESD measures are taken beforehand.
Electrical installation
ƒCarry out the electrical installation according to the relevant regulations (e. g. cable
cross−sections, fusing, connection to the PE conductor). Additional notes are
included in the documentation.
ƒWhen working on live products, observe the applicable national regulations for the
prevention of accidents (e.g. BGV 3).
ƒThe documentation contains notes for the EMC−compliant installation (shielding,
earthing, arrangement of filters and installation of the cables). The manufacturer of
the system or machine is responsible for the compliance with the limit values
required in connection with EMC legislation.
ƒFor compliance with the limit values for radio interference emission at the site of
installation, the components − if specified in the technical data − have to be mounted
in housings (e. g. control cabinets). The housings have to enable an EMC−compliant
installation. In particular observe that for example control cabinet doors preferably
have a circumferential metallic connection to the housing. Reduce openings or
cutouts through the housing to a minimum.
ƒOnly plug in or remove pluggable terminals in the deenergised state!
Commissioning
ƒIf required, you have to equip the system with additional monitoring and protective
devices in accordance with the respective valid safety regulations (e. g. law on
technical equipment, regulations for the prevention of accidents).

Safety instructions
Product−specific safety instructions
2
11
BA_MP9000DVI DE 4.0
Maintenance and servicing
ƒThe components are maintenance−free if the required operating conditions are
observed.
ƒIf the cooling air is polluted, the cooling surfaces may be contaminated or the air
vents may be blocked. Under these operating conditions, the cooling surfaces and air
vents must be cleaned at regular intervals. Never use sharp objects for this purpose!
ƒAfter the system has been disconnected from the supply voltage, live components
and power connections must not be touched immediately because capacitors may
be charged. Please observe the corresponding notes on the device.
Disposal
ƒRecycle or dispose of the product according to the applicable regulations.
2.2 Product−specific safety instructions
ƒProtect the device against direct solar radiation, since the housing may heat up
strongly.
ƒThe device is classified as a class A device and can cause radio interference in
residential areas. In this case, the operator may have to take special measures. Any
costs arising from these measures have to be paid by the operator.
ƒA touchscreen does not comply with the Ergonomics Directive ZH 1/618. This is why
it is only designed for short−time inputs and monitoring functions. For longer inputs,
connect an external keyboard.
ƒIn the event of a fault, unplug the power connector immediately and send back the
device to the manufacturer. The address can be found on the self−addressed
envelope included in this documentation. Please use the original packaging to
return the device!
ƒPrinted circuit boards which might be damaged by short circuit or electrostatic
discharge (ESD) must be handled appropriately.

Safety instructions
Safety instructions for the installation according to UL
2
12 BA_MP9000DVI DE 4.0
2.3 Safety instructions for the installation according to UL
Original − English
Approval
Underwriter Laboratories (UL), UL508 and CSA C22.2 No. 142−M1987, (UL File Number
E236341)
Ratings
ƒInput 24 V DC, 65 W
ƒFor use on an isolated power supply rated 24V DC 4A max.
ƒMax. ambient temperature 40°C
ƒMax. surrounding temperature 50 °C
ƒOptional communication ratings:
– RS232−Connection (APL and DPL version only): max. 3 A
– USB−Connection (DVI version only): max. 1 A
– PS/2−Connection: max. 1 A
– VGA−Connection (APL version only): max. 4 A
– FBAS−Connection (APL version only): max. 4 A
– DVI−Connector (DVI version only): max. 4 A
– DPL−Connection (DVI version only): max. 4 A
– External Power Supply for DVI/USB Extender: max. 4 A
– Video−DSUB Connection for DVI/USB Extender: max. 4 A
– Data−DSUB Connection for DVI/USB Extender: max. 4 A
ƒEnvironmental ratings: If these devices are mounted into a door or front cover of an
enclosure: Type 1 Enclosure.
Warnings!
Conditions of acceptability
ƒThese devices are for Type 1 front panel mounting only.
ƒThe external power supply connection is suitable for field wiring. An isolated
power supply rated 24 V DC, 4 A max. must be used.
Field Wiring Markings
Wiring Terminal MSTB 2,5/3−STF−5,08:
ƒUse Copper Wire only.
ƒAWG 18 ... AWG 12 (0.82 mm2... 3.3 mm2)
ƒTorque 5...7 lb−in (0.5 ... 0.6 Nm)

Safety instructions
Safety instructions for the installation according to UL
2
13
BA_MP9000DVI DE 4.0
Original − French
Homologation
Underwriter Laboratories (UL), UL508 et CSA C22.2 n° 142−M1987, (n° de dossier UL
E236341)
Caractéristiques assignées
ƒEntrée 24 V CC, 65 W
ƒEquipement destiné à une alimentation avec isolation galvanique de 24V CC, 4A
maximum (tension assignée).
ƒTempérature ambiante maximale : 40°C
ƒTempérature ambiante maximale : 50 °C
ƒCaractéristiques de communication assignées (option) :
– Port RS232 (versions APL et DPL uniquement) : maximum 3 A
– Port USB (version DVI uniquement) : maximum 1 A
– Port PS/2 : maximum 1 A
– Port VGA (version APL uniquement ) : maximum 4 A
– Port FBAS (version APL uniquement) : maximum 4 A
– Port DVI (version DVI uniquement) : maximum 4 A
– Port DPL (version DVI uniquement) : maximum 4 A
– Alimentation externe pour carte d’extension DVI/USB : maximum 4 A
– Port vidéo DSUB pour carte d’extension DVI/USB : maximum 4 A
– Port de données DSUB pour carte d’extension DVI/USB : maximum 4 A
ƒEvaluations environnementales : en cas de montage des équipements dans la porte
ou le capot avant d’un coffret de protection : coffret de type 1.
Warnings!
Conditions of acceptability
ƒCes équipements sont conçus pour un montage de type 1 sur panneau
avant uniquement.
ƒLe raccord d’alimentation externe est adapté à un câblage à pied d’oeuvre.
Utiliser impérativement une alimentation avec isolation galvanique de 24V
CC, 4A maximum (tension assignée).
Marquage du câblage à pied d’oeuvre
Bornier de câblage MSTB 2,5/3−STF−5,08 :
ƒUtiliser exclusivement des conducteurs en cuivre.
ƒAWG 18 ... AWG 12 (0,82 mm2... 3,3 mm2)
ƒCouple de 5 à 7 lb−in (0,5 ... 0,6 Nm)

Product description
Scope of supply
3
14 BA_MP9000DVI DE 4.0
3 Product description
3.1 Scope of supply
Quanti
ty
Name
1 Monitor panel
8
8
4
6
5
6
Screw clamp fixings
MP 800 DVI
MP 1000 DVI, MP 1000s DVI, MP 1050 DVI, MP 1050s DVI
MP 2000 DVI
MP 2050 DVI, MP 5000 DVI, MP 5020 DVI, MP 5050 DVI
MP 5070 DVI
MP 9000 DVI
1Connection plug for voltage supply
1DVI−D cable (length 2 m)
1USB cable (length 2 m)
1DVD "PC based Automation"
1Test report
1Device pass card
Note!
After receipt of the delivery, check immediately whether the items match the
accompanying papers. We do not accept any liability for deficiencies claimed
subsequently.
Claim
ƒvisible transport damage immediately to the forwarder
ƒvisible deficiencies/incompleteness immediately to your Lenze
representative.

Product description
Application as directed
3
15
BA_MP9000DVI DE 4.0
3.2 Application as directed
The monitor panel is used as intended if it is used solely for providing information in
common industrial and commercial areas. Another use or any further use is not
permissible.
A use that is not intended also includes a use harbouring fatal risks or dangers which,
without the provision of exceptionally high safety measures, may result in death, injury or
damage to material assets.
The monitor panel must in particular not be used ...
ƒin private areas.
ƒin potentially explosive atmospheres.
ƒin areas with harmful gases, oils, acids, radiation, etc.
ƒin applications where vibration and impact loads occur, exceeding the requirements
of EN 50178.
ƒfor performing safety functions, for instance
– in air traffic control / in flight−control systems
– for the monitoring/control of nuclear reactions
– for the monitoring/control of means of mass transport
– for the monitoring/control of medical systems
– for the monitoring/control of weapon systems
Higher−level safety systems must be used to guarantee the protection of persons and
material assets!
3.3 Device features
MP 800 DVI ... MP 9000 DVI
Design lPC housing of sheet steel
lFront frame of anodised and etched aluminium
lFront made of polyester foil
Mounting lFor installation in control cabinets, machine enclosures, and control
boards
Electrical supply l24 V DC voltage supply
Interfaces l1 x DVI
l2 x USB type A (V 2.0)
l1 x USB type B (V 2.0)
Accessories
ƒDVI/USB extender

Product description
Device features
3
16 BA_MP9000DVI DE 4.0
Overview
Monitor panel MP 800 DVI / MP 1000 DVI / MP 1000s DVI / MP 2000 DVI / MP 5000 DVI / MP 9000 DVI
-
F3
Fail
Power
F1
+
F2
Status
lMP 800 DVI: VGA touchscreen 20.3 cm (8")
MP 1000 DVI: VGA touchscreen 26.4 cm (10.4")
MP 1000s DVI: SVGA touchscreen 26.4 cm (10.4")
MP 2000 DVI: SVGA touchscreen 30.7 cm (12.1")
MP 5000 DVI: XGA touchscreen 38.1 cm (15")
MP 9000 DVI: SXGA touchscreen 48.3 cm (19")
l3 freely assignable function keys
CS57x0−026
Monitor panel MP 5020 DVI
S13
S14
S11
S10
S12
S6
S7
F3F2
+
-
F4
Status
Power
Fail
F1
Esc Enter
F11 F12F6F5 F7 F8 F9 F10
S1
S4
S2
S3
S5
S8
S9
lXGA touchscreen 38.1 cm (15")
l12 freely assignable function keys
l14 freely assignable special keys
ELx7xx−002
Monitor panel MP 1050 DVI / MP 1050s DVI / MP 2050 DVI / MP 5050 DVI
Q+R
F1 F2 F5
-
ST
F3 F4
@\Z
F11F10
YX
F9F8 F12
WVU
F7F6
Shift
Alpha
Bs
Space
Enter
EscDelIns
Menu
AltCtrl
Home
1
I
0
M
4
E
7
A
Pg Dn
*
3
JKL
/
,
NOP
Pg Up
End
Status
Power
Fail
2
.
+6
FGH
-
9
BCD
5
8
lMP 1050 DVI: VGA touchscreen 26.4 cm (10.4")
MP 1050s DVI: SVGA touchscreen 26.4 cm (10.4")
MP 2050 DVI: SVGA touchscreen 30.7 cm (12.1")
MP 5050 DVI: XGA touchscreen 38.1 cm (15")
l12 freely assignable function keys
lNumeric keypad, control keys, level switch−over
Alpha
CS57x0−028

Product description
Device features
3
17
BA_MP9000DVI DE 4.0
Monitor panel MP 5070 DVI
"
(
§
&
)
=
/
$
!
>/
*
-
+
,
|
546
879
123
<
0
-
+
Alt Strg
*
+
T
F4
€
D
EWQ
XY
SA
@
F3F1 F2
R
VC
F
F5
GH J
-
_
Ä
F9F8F6 F7 F10
OIPÜUZ
Ö
;
,:
M
μ
.
LK
NB
Space
Enter
\
?
ß
~
F12
Esc
F11
Pos 1
Einfg
Ende
Entf
Bs
Alt Gr
Fail
Status
Power
Bild
Bild
lXGA touchscreen 38.1 cm (15")
l12 freely assignable function keys
lMF2 keyboard
CS57x0−029

Product description
Identification
3
18 BA_MP9000DVI DE 4.0
3.4 Identification
107AT12345
107AT12345
31855 Aerzen; Germany
Madein Germany
Type
DVIUSB−012
Type designation
Type code (catalogue/order no.)
Technical data
Customised material number
Bar code with serial number
Manufacturer address
Certification
CE mark
Type code xxxx 2 x 1
5201 = MP 1000 DVI
5202 = MP 1000s DVI
5203 = MP 2000 DVI
5204 = MP 5000 DVI
5205 = MP 9000 DVI
5206 = MP 5020 DVI
5207 = MP 1050 DVI
5208 = MP 1050s DVI
5209 = MP 2050 DVI
5210 = MP 5050 DVI
5211 = MP 5070 DVI, keyboard layout German
5212 = MP 5070 DVI, keyboard layout English
5213 = MP 800 DVI
Front face USB socket
0 = without
1 = with (IP65)

Product description
Controls and displays
3
19
BA_MP9000DVI DE 4.0
3.5 Controls and displays
-
F3
Fail
Power
F1
+
F2
Status
10
0 1
5
4
32
+
DVI
USB-A
USB-B
24 VDC
0V U
0V U
MP9000DVI−001
Pos. Description
Monitor panel (here MP 5000 DVI)
Front face USB port (option)
Screw clamp fixings
Nameplate
Status LEDs (Power, Fail, Status)
Front face control and display elements
Note!
Further information on the control and display elements can be gathered from
the chapter "Operation" (32).

Technical data
General data and operating conditions
4
20 BA_MP9000DVI DE 4.0
4 Technical data
4.1 General data and operating conditions
General data
Conformity and approval
Conformity
CE EN 61000−6−4
EN 61000−6−2
EMC Directive Class A, industrial premises
Approbation
UR UL 508
CSA C22.2
Programmable Controllers (File−No. E236341)
Other
RoHS − Products lead−free in accordance with CE Directive
2011/65/EU
Protection of persons and equipment
Safety VDE0805 (EN60950),
VDE0870, UL
Enclosure EN 60529 IP65 (front) / IP20 (back)
UL 508 (NEMA 250) Type 1 enclosure
Class of protection 3
EMC
Noise emission EN 61000−6−4 Class A (industrial premises)
Noise immunity zone B EN 61000−6−2 Industrial premises
EN 61000−4−2 ESD; severity level 3, i. e.
8 kV for air discharge,
4 kV for contact discharge
EN 61000−4−3 RF interference (housing)
80 MHz 1000 MHz, 10 V/m 80 % AM (1 kHz)
EN 61000−4−4 Burst, severity level 3
EN 61000−4−5 Surge, severity level 1 *
EN 61000−4−6 RF cable−guided
150 kHz 80 MHz, 10 V/m 80 % AM (1 kHz)
* Due to the high−energy single current pulses, surges require suitable external wiring with lightning protection
elements like for example lightning conductors and overvoltage arresters.
Other manuals for MP 800 DVI
1
This manual suits for next models
11
Table of contents
Other Lenze Industrial Monitor manuals
Popular Industrial Monitor manuals by other brands

Synergy Global Technology
Synergy Global Technology LCDR8U21-03 user manual

Autonics
Autonics GP-XBC Solution guide

Saia
Saia PCD7.D410VTCF manual

Allen-Bradley
Allen-Bradley Industrial 10.4" Flat Panel Monitor Installation and user manual

Xinje
Xinje OP320 user manual

Atlas
Atlas ATM1700 Quick installation guide