IES-1610 Page 1
Overview
LevelOne IES-1611 Industry Ethernet Switchprovides 15 ports of
10/100Base-TX Ethernet plus 1port 100Base-FX MM SC fiber to
enable highspeed network at mission-critical environment. This
device is designed to be mounted onan industry standard DIN-rail,
plus the clearly visible status LEDs provide simple monitoringof
port link activity.
Cost Effective
This device operates under -10 to 60 Celsius (-14 to 140 Fahrenheit)
temperature that offers optimal suitability for industrial
applications at low cost while maintaining all components built to
withstand harsh environmentapplications without compromise
reliability and stability.
Redundancy
This redundant power system is designed to meet the challenge of
power failure to ensure reliability and constant availability. Single
power design works fine in non-critical networkapplications, but it
falls short drastically for network applications intransportation,
automate productionor banking.
Safety
This device has been tested under UL508 standard for Industrial
Control Equipment to endurance under test turn on and off 6,000
times while loaded, with no single failure. It’s highly reliability and
safety measurement toensure field hardened, especially for the
harshenvironment.
IES-1610 Page 2
Features
•Meets EN61000-6-2 & EN61000-6-4 EMC Generic Standard Immunity for
industrialenvironment.
•Supports IEEE802.3/802.3u/802.3x. Auto-negotiation: 10/100Mbps, Full/Half-
duplex, Auto-Negotiation, Auto MDI/MDIX.
•100Base-FX: Multi/Single mode SC or ST type, WDM Single mode SC type.
•Supports 4096 MAC addresses. Provides 1.625M bits buffer memory.
•Alarms for power failure by relay output 1A @ 24VDC.
•Power Supplies: Redundant 12-48VDC Terminal Block power inputs and 12VDC
DC JACK with 100-240VAC external power supply.
•Field Wiring Terminal: Use Copper Conductors Only, 60/75℃, 12-24 AWG torque
value 7 lb-in.
•Operating voltage and Max. current consumption: 0.7A @ 12VDC, 0.35A @
24VDC, 0.175A @ 48VDC. Power consumption: 8.4W Max.
•Operating temperature ranges from -10℃to 60℃(14℉to 140℉). UL508
Industrial Control Equipment certified Maximum Surrounding Air Temperature
@ 60℃(140℉).
•For use in Pollution Degree 2 Environment.
•Supports Din-rail or Panel Mounting installation.
Package Contents
§IES-1611
§Quick InstallationGuide
IES-1610 Page 3
LED Status
LED Status Description
PW 1,2,3 Steady Power On
Off Power Off
10/100Base-TX or 100Base-FX
LNK/ACT
(Green)
Steady Network connection is established
Flashing Transmitting or Receiving data