LF Harbor Breeze L1902 User manual

1
Español p. 19
SARATOGA
CEILING FAN
ITEM #0883772
MODEL #L1902
Serial Number Purchase Date
Questions, problems, missing parts? Before returning to your retailer, call our customer
service department at 1-800-643-0067, 8 a.m. - 6 p.m., EST, Monday - Thursday,
8 a.m. - 5 p.m., EST, Friday.
PH19239
ATTACH YOUR RECEIPT HERE
Harbor Breeze®is a registered trademark
of LF, LLC. All Rights Reserved.

2
TABLE OF CONTENTS
Package Contents...............................................................................................................
Hardware Contents.............................................................................................................
Safety Information...............................................................................................................
Preparation .........................................................................................................................
Initial Installation Instructions ....................................................................................................
Standard/Angle-Mounting Instructions.................................................................................
Wiring Instructions ..............................................................................................................
Final Installation Instructions ...............................................................................................
Operating Instructions ........................................................................................................
Care and Maintenance .......................................................................................................
Troubleshooting...................................................................................................................
Limited Lifetime Warranty....................................................................................................
Replacement Part List .........................................................................................................
3
4
4
5
6
7
9
10
13
15
15
17
FCC Warning........................................................................................................................17
18

3
PACKAGE CONTENTS
PART DESCRIPTION QUANTITY PART DESCRIPTION QUANTITY
1
1
C Canopy 1
Coupling
(preassembled on Motor Housing (F))
1
DCanopy Cover 1
Mounting Bracket Screw
(preassembled on Mounting Bracket (A))
2
1
Clevis Pin (preassembled
on Downrod Assembly (B)) 1
F Motor Housing 1
Hairpin Clip (preassembled
on Downrod Assembly (B)) 1
G Blade Arm 5
Coupling Screw
(preassembled on Coupling (M)) 2
H Blade 5
I Sw
itch Housing 1
Mounting Screw
(preassembled on Motor Housing (F))
3
JLED Light Kit 1
Switch Housing Screw
(preassembled on Switch Housing (I))
3
K Glass Bowl 1
LRemote Unit 1
M
N
O
P
Q
R
S
A
AM
G
J
K
L
I
F
H
B
O
P
D
E
C
N
S
R
THIS SIDE UP

4
HARDWARE CONTENTS
SAFETY INFORMATION
(not shown actual size)
AA BB CC
READ AND SAVE THESE INSTRUCTIONS
Please read and understand this entire manual before attempting to assemble, operate or install the product.
. All electrical connections must comply with local codes, ordinances or the National Electric Code (NEC).
Contact your municipal building department to inquire about your local codes, permits and/or inspections.
. Turn off electricity at main fuse box (or circuit breaker box) before beginning installation by removing fuse
or by switching off circuit breaker.
. Do not connect this fixture to an electrical system that does not provide a means for equipment grounding.
Never use a fixture in a two-wire system that is not grounded.
. If you are not sure your lighting system has a grounding means, do not attempt to install this fixture. Contact
a qualified, licensed electrician for information regarding proper grounding methods as required by the local
electrical code in your area.
. Make sure the installation site you choose allows a minimum clearance of 7 ft. from the blades to the floor
and at least 30 in. from the ends of the blades to any obstruction.
. If a dimmer control switch is used with this fixture, obtain professional advice to determine the correct type
and electrical rating required.
. The lighting fixture must be positioned so there is at least 1.64 ft. between the bulb and any illuminated
surface.
. For supply connections, if the conductor of a fan is identified as a grounded conductor, then it should be
connected to a grounded conductor power supply. If the conductor of a fan is identified as an ungrounded
conductor, then it should be connected to an ungrounded conductor power supply. If the conductor of a fan
is identified for equipment grounding, then it should be connected to an equipment-grounding conductor.
. Installing a fixture into an electrical system without a proper grounding means could allow metal parts of the
fixture to carry electrical currents. If any of the fixture wires, wire connections or splices are broken, cut or
loose during the mounting or normal operation of the fixture, under such conditon, anyone coming in contact
with the fixture is subject to electrical shock, which could cause serious injury or death.
. Connection of the bare or green fixture ground wire to the black or white house wires may allow metal parts
of the fixture to carry electrical currents. Under this condition anyone coming in contact with the fixture will
receive electrical shock, which could cause serious injury or death.
. Be careful not to damage or cut the wire insulation (covering) during fixture installation. Do not permit wires
to have contact with any surface having a sharp edge. Doing so may damage or cut the wire insulation,
which could cause serious injury or death from electric shock.
DANGER
Decorative Nut
Qty.15
Blade Arm Screw
Qty.10+1 extra
Blade Screw
Qty.15+1 extra

5
WARNING
CAUTION
PREPARATION
Estimated Assembly Time:

6
INITIAL INSTALLATION INSTRUCTIONS
DANGER:
Failure to disconnect power supply prior to
1.
Turn off circuit breakers and wall switch to the fan supply
line leads.
2. Choose the desired mounting method:
Standard mounting is best suited for ceilings 8 feet. or
higher. For taller ceilings you may want to use a longer
downrod (not included).
Angle-style mounting is best suited for angled or vaulted
ceilings. A longer downrod is sometimes necessary to
ensure proper blade clearance. If using the angle mount,
make sure the ceiling angle is not steeper than 20°.
3.
Check existing outlet box (not included) to ensure it is
securely fastened to at least two points in a structural
ceiling member and can support the full weight of the fan.
Once verified, install mounting bracket (A) to the outlet
box using the screws and washers provided with the
outlet box.
installation may result in serious injury or death.
DANGER:
A loose outlet box can cause the fan to
Note:
If using the angle mount, make sure open end of
wobble and increase the fan’s potential to fall, which
mounting bracket (A) points toward the ceiling.
could result in serious injury or death.
For ALL mounting options, there must be at least 30 inches
from the blade tip to nearest wall. Also, ensure there is 7
feet from the bottom edge of the blade to the floor.
A
B
2
3Standard
Mounting
A
Angle
Mounting
A
or
T
Turn Off Power Source
1

7
INITIAL INSTALLATION INSTRUCTIONS
4. Loosen the two coupling screws(Q) preassembled in
coupling (M), but do not remove them.
Remove the hairpin clip (P) and clevis pin (O) from the
downrod assembly (B). Retain for later use.
Note: Make sure to keep loose hardware separate to
avoid confusion during installation.
STANDARD/ANGLE-MOUNTING INSTRUCTIONS
1. Place downrod assembly (B) through canopy (C), canopy
cover (D) and coupling cover (E).
C
D
E
B
M
1
Feed power wires from motor housing (F) through
downrod assembly (B), then insert downrod assembly
(B) into the coupling (M) on motor housing (F).
2. Align the hole on downrod assembly (B) to hole on
coupling, then re-install clevis pin (O). Re-attach hairpin
clip (P) into clevis pin (O) until it snaps into place, then
tighten the two previously loosened coupling screws (Q).
PBO
Q
2
Q
P
B
O
4

8
CAUTION: Ensure all screws are tight before moving
onto the next step.
STANDARD/ANGLE-MOUNTING INSTRUCTIONS
3. Cut off excess fixture wires, leaving approximately 6 to
9 inches above the top of the downrod assembly (B).
Strip 1/2 inch of insulation from the end of each fixture
wire.
4. Carefully lift the assembly and rest the hanger ball of
downrod assembly (B) on the mounting bracket (A)
attached to the outlet box. Be sure the groove in the
hanger ball is lined up with the tab on the mounting
bracket (A). This will allow for hands-free wiring.
Proceed to WIRING on page 9.
DANGER: Be careful when aligning the tab to the slot !
If not fully engaged, there is a possibility of the fan
falling, which may result in serious injury or death.
3
A
4
Hanger Ball
Groove
Tab
6 to 9 in.

9
Hardware Used
Wire Connector x 6
WIRING INSTRUCTIONS
1. Follow steps below to wiring your fan, once wiring step
has been completed, slide the wired receiver in between
the mounting bracket (A) and the top of the downrod ball
(B) with the flat side of the receiver facing the ceiling.
● Connect WHITE wire from the fan to WHITE wire marked
TO MOTOR N from the receiver.
● Connect BLUE wire from the fan to BLUE wire marked
FOR LIGHT from the receiver.
● Connect BLACK wire from the fan to BLACK wire marked
TO MOTOR L from the receiver.
● Connect BLACK wire from the outlet box to BLACK wire
marked AC IN L from the receiver.
● Connect WHITE wire from the outlet box to WHITE wire
marked AC IN N from the receiver.
● Connect GROUND (GREEN) wires from mounting
bracket and downrod ball, to GROUND (GREEN or
BARE COPPER) from house.
WARNING: To avoid possible electrical shock, be sure electricity is turned off at the main fuse
box before hanging.
WARNING: If you are not sure if the outlet box is grounded, contact a licensed electrician for
advice, as it must be grounded for safe operation.
WARNING: If house wires are different colors than referred to in the following steps, stop
immediately. A professional electrician is recommended to determine proper wiring.
WARNING: If you feel that you do not have enough electrical wiring knowledge or experience,
have your fan installed by a licensed electrician.
1
2.
2
BLACK
BLUE
WHITE
GREEN
Outlet Box
B
A
Wrap electrical tape (not included) around each wire
connector and make sure no bare wire or wire strands
are visible after making connections. Then, turn wires
upward and carefully push them into the outlet box;
make sure the WHITE and GREEN connections are on
one side and the BLACK connections are on the other
side.
Grounded/Green
Black
Grounded/Green
White
Receiver

10
1. Loosen (but do not remove) the two preassembled
mounting screws (N) on mounting bracket (A) that align
with the slotted holes on canopy (C). Lift canopy (C) up
so slotted holes engage loosened screw heads on
mounting bracket (A), then twist canopy (C) clockwise,
then tighten all screws securely.
2. Raise canopy cover (D) over the mounting screws visible
in canopy (C). Rotate canopy cover (D) clockwise until it
locks into place. You may need to adjust the mounting
screws until the canopy (C) and canopy cover (D) have
a snug fit.
3. Attach blade (H) under blade arm (G) using three (3)
decorative nuts (CC) and three (3) blade screws (AA).
Repeat for remaining blades (H), blade arms (G),
decorative nuts (CC) and three (3) blade screws (AA).
2
Hardware Used
Blade Screw x 15
x 15
AA
Decorative Nut
CC
1
N
A
C
D
C
3
GH
AA
CC
FINAL INSTALLATION INSTRUCTIONS

11
FINAL INSTALLATION INSTRUCTIONS
6. Insert the wires from the motor housing (F) through the
center hole in the switch housing (I). Attach the switch
housing (I) to the mounting plate on motor housing (F)
by placing the keyslot holes from the switch housing (I)
onto the two protruding mounting screw (R) heads.
4. Insert blade assembly through slot on fan motor
assembly (F) and align two screw holes in blade arm
(G) with screw holes in fan motor assembly (F). Secure
with two blade arm screws (BB). Repeat for remaining
blade assemblies.
4
5. Remove one of the mounting screws (R) on mounting
plate on motor housing (F), then loosen the other two.
Blade Arm Screw x 10
BB
Hardware Used
5
6
F
G
I
R
BB
Slot
Mounting
Plate
F
R
Screws
Mounting
Plate
(loosen only)
Screw
(remove)
Keyslots

F
F
R
I
J
12
FINAL INSTALLATION INSTRUCTIONS
9. Connect the 2 single pin connectors from the LED light
kit (J) to the 2 single pin connectors from motor
assembly(F). Connect the black wire to black wire, and
white wire to white wire.
7. Adjust the switch housing (I) until the screw heads are
aligned with the keyholes, then re-insert mounting
screw (R) previously removed on step 5. Tighten all
mounting screws (R) securely.
7
8. Remove one of the screws (S) on switch housing (I),
then loosen the other two.
8
9
Screw
(remove)
Screws
(loosen only)

S
K
J
I
13
FINAL INSTALATION INSTRUCTIONS
10. Adjust the LED light kit (J ) until the screw heads are
aligned with the keyholes, then re-insert mounting
screw (S) previously removed on step 8. Tighten all
mounting screws (S) securely.
10
11. Secure the glass (K) to switch housing (I) by twisting
in a clockwise direction. Do not over-tighten.
11
Screw
OPERATING INSTRUCTIONS
1. When the season changes, you may want to change
the direction in which the fan spins.
In warmer weather, counterclockwise rotation creates a
downward airflow, which cools the air. Push the switch
LEFT and see a SUN icon.
In cooler weather, clockwise rotation creates an upward
airflow,which moves hot air from the ceiling. Push the
switch RIGHT and see a SNOWFLAKE icon.
WARNING: Turn off and wait for fan to stop before
flipping the reverse switch.
Note:Use a small screwdriver or ballpoint pen to move
the reverse switch if you have difficulty doing so by
hand.
1

14
OPERATING INSTRUCTIONS
2. The remote unit has 16 different code combinations. To
prevent possible interference from the other remote
units, simply change the combination code in the
remote by following the set up procedures listed below.
a.)Remove the remote control battery cover to expose
the remote dip switches. Use a small ballpoint pen (not
included) to set the dip switches to either up or down.
NOTE:
Factory setting is all up. Do not use this
position.
b.)Install the 23A 12V battery (included) and replace
the battery cover you previously removed.
c.)Restore power to the fan, press and hold the “Light”
button until the light flashes (on/off) 3 times and will
stay on, then the control and speed setting process is
complete.
NOTE:
You must press the “Light” button within 30
seconds of restoring power to the fan.
d.)If programming is unsuccessful, retry the above
instructions.
NOTE:
Remove batteries if remote has not been used
for a long period of time in order to avoid damage.
Store remote away from excessive heat or humidity.
3. The buttons on the remote control the fan speed and
light as follows:
Note: This receiver has a preset memory function;
when the switch is turned OFF, the control will
remember the light intensity and fan speed. When the
switch is turned ON, the light and fan will resume
operation as they were prior to the switch being turned
OFF.
2
Low speed
Medium speed
High speed
Turn the fan off
Press the light key quickly and turn the light ON
or OFF.
Press and hold to dim light.
The light will cycle from bright to dim to bright
until button is released.
Remote
Battery Cover
Battery
2
134
ON DIP
3

1. Set screws are loose. 1. Tighten all set screws.
2. Using non-approved speed control. 2. Some fan motors are sensitive to signals from solid-
state varible speed controls. DO NOT USE a solid-
state variable speed control.
3. Normal noise. 3. Allow "break-in" period of 24 hours. Most noises
associated with a newfan will disappearafterthis
period.
4. Wire connectors inside switch
housing rattling.
4. Check to make sure wire connectors in switch
housing are not rattling against each otheroragainst
the interior wall of the switch housing.
5. Cracked blade.5. Replace blades.
6. The distance from canopyto ceiling
is too great.
6. Make sure upper canopy is a short distance from
ceiling. It should not touch the ceiling.
7. Glass is not secure. 7. Secure the glass.
1. Hangerbracket and/or ceiling outlet
box is not securely fastened.
1. Tighten the hangerbracket screws to the outlet box,
and/or secure outlet box.
2. Set screw in downrod assembly is
loose.
2. Tighten the set screw in the downrod assembly.
seated in canopytabs.
3. Fan hangerball is not properly 3. Turn power off, support the fan very carefully, and
check that the hangerball is properly seated.
4. Set screw in motor coupling is loose. 4. Raise motor coupling up and tighten set screws
securely.
5. Blade is loose. 5. Check that all bladesare screwed firmly into blade
holders.
Fan soundsnoisy
Fan wobbles
15
CARE AND MAINTENANCE
TROUBLESHOOTING
Important: Shut off main power supply before beginning any maintenance. Do not use water or a
damp cloth to clean the ceiling fan.
. At least twice each year, tighten all screws and lower canopy to check mounting plate screws.
. Clean fan housing with only a soft brush or lint-free cloth to avoid scratching the finish. Clean blades
with a lint-free cloth. You may occasionally apply a light coat of furniture polish to wood blades for
added protection.
PROBABLE CAUSE CORRECTIVE ACTION
PROBLEM

16
TROUBLESHOOTING
6. Blade holders are loose. 6. Check to be sure the fan blade irons seat firmly and
uniformly on the surface of the motor. If flangesare
seated incorrectly, loosen the flange screws and
retighten.
7. Blade out of balance. 7. Interchange two adjacent blades; this will redistribute
the weight and possibly result in smootheroperation.
8. Fan too close to vaulted ceiling.8. Lower or move fan. Extension downrods may be
ordered.
9. Transition to different speed.9. When switching from medium to low speed, you may
notice some fan wobble in the fan. When the fan
stabilizes at low speed, wobble should disappear.
10. Fan not securely mounted.10. Make sure canopyand mounting bracket are
tightened securely to ceiling joist.
1. Power turned off, fuse blown orcircuit
breaker tripped.
1. Turn power on, replace fuse or reset breaker.
3. Motor reversing switch not engaged.3. Push switch firmly right or left. Fan will not operate
when switch is in the middle.
1. Wrong wire connection.1. Referto Step 3, page 12 to ensure all wire
connections were done correctly.
Fan doesnot start
2b. Check the plug connection in the switch housing.
2a. Turn power off and loosen canopy; check all
connectionsaccording to section WIRING
INSTRUCTIONS on page 9.
2. Loose wire connectionsor wrong
connections.
Light doesnot work
Fan wobbles
PROBLEM PROBABLE CAUSE CORRECTIVE ACTION

17
LIMITED LIFETIME WARRANTY
FCC WARNING
The manufacturer warrants this fan to be free from defects in workmanship and material present at
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two
conditions:
(1) This device may not cause harmful interference, and (2) this device must accept any interference
received, including interference that may cause undesired operation. Please note that changes or
modifications not expressly approved by the party responsible for compliance could void the user's
authority to operate the equipment.
Note: This equipment has been tested and found to comply with the limits for Class B digital device,
pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection
against harmful interference in a residential installation.
This equipment generates, uses and can radiate radio frequency energy and, if not installed and
used in accordance with the instructions, may cause harmful interference to radio or television
reception, which can be determined by turning the equipment off and on, the user is encouraged to
try to correct the interference by one or more of the following measures:
- Reorient or relocate the receiving antenna.
- Increase the separation between the equipment and the receiver.
- Connect the equipment into an outlet on a circuit different from that to which the receiver is
connected.
Consult the dealer or an experienced radio/TV technician for help.
time of shipment from the factory for life (with limitations) from the date of purchase. This warranty
applies only to the original purchaser. The manufacturer agrees to correct such defect at no charge
or, at our option, replace the ceiling fan with a comparable or superior model.
To obtain warranty service, present a copy of your sales receipt as proof of purchase. All cost of
removal and reinstallation are the expressed responsibility of the purchaser. Any damage to the
ceiling fan by accident, misuse or improper installation, or by affixing accessories not produced by
this warranty, are at the purchaser’s own responsibility. The manufacturer assumes no responsibility
whatsoever for fan installation during the limited lifetime warranty. Any service performed by an
unauthorized person will render the warranty invalid.
Due to varying climatic conditions, this warranty does not cover changes in brass finish, rusting,
pitting, tarnishing, corroding or peeling. Brass finish fans maintain their beauty when protected from
varying weather conditions.
The duration of any implied warranty which can not be disclaimed is limited to the lifetime limited
period as specified in our warranty. The manufacturer shall not be liable for incidental, consequential
or special damages arising at or in connection with product use or performance except as may other
wise be accorded by law. This warranty gives you specific legal rights, and you also have other rights
which vary from state to state. This warranty supersedes all prior warranties.
NOTE: A small amount of “ wobble ” is normal and should not be considered a defect.
Any replacement of defective parts for the ceiling fan must be reported within the first year from
the date of purchase. For the balance of the warranty, call our customer service department at
1-800-643-0067 for return authorization and shipping instructions so that we may repair or replace the
ceiling fan. Any fan or parts returned improperly packaged is the sole responsibility of the purchaser.
There is no further expressed warranty. The manufacturer disclaims any and all implied warranties.

18
Printed in China
REPLACEMENT PART LIST
For replacement parts, call our customer service department at 1-800-643-0067, 8 a.m. - 6 p.m., EST,
Monday - Thursday, 8 a.m. - 5 p.m., EST, Friday.
A Mounting Bracket A102-0219070
B Downrod Assembly A103-0414492
C CanopyA101-0497492
D Canopy Cover A108-0013492
E Coupling Cover A106-0171492
G Blade Arm A143-0382492
H BladeA141-0620030
I Switch Housing A121-0452492
JLED Light Kit A187-0486036
K Glass Bowl
Blade Screw
Decorative Nut
Blade Arm Screw
A182-0492030
AA
BB
CC
B168-0600070
Part Description Part#
AG
J
K
I
H
BD
E
CAA BB CC
THIS SIDE UP
Table of contents
Other LF Fan manuals

LF
LF Harbor Breeze KINGSBURY User manual

LF
LF Harbor Breeze CALAVAR 52 User manual

LF
LF Harbor Breeze FLORENCE 42127 User manual

LF
LF Harbor Breeze FAIRWIND C-FW60BNK3LR User manual

LF
LF Harbor Breeze OYSTER COVE User manual

LF
LF Harbor Breeze SUMMERSVILLE 42192 User manual

LF
LF Harbor Breeze BDB52MBK5M User manual

LF
LF Harbor Breeze Gaskin User manual
Popular Fan manuals by other brands

O2cool
O2cool FMD0001A instruction manual

Halton
Halton EcoloAir 3000CFM installation manual

Applica
Applica WSF-16T Use and care book

QUORUM INTERNATIONAL
QUORUM INTERNATIONAL The Salon installation instructions

Kichler Lighting
Kichler Lighting Monarch II Select instruction manual

EYELA
EYELA Cool Ace CA-2610 instruction manual