LG AUUW09GA0 Product guide

FDF
Heat Pump 50Hz/410A
5CSL0-02C(Replaces:5CSL0-02B)
P/No. : MFL67502810

General Information
Single CAC
Outdoor Unit
FDF
1.Model Line Up
2.Nomenclature

2
Single CAC Outdoor Unit General Information
1. Model Line Up
1.1 Standard Inverter
1 Phase Inverter
Model Names AUUW09GA0
[UU09W UL0]
AUUW12GA0
[UU12W UL0]
AUUW18GAE
[UU18W UE4]
No. of connectable indoor
units 1
Total capacity index of
connectable indoor units(kW) 2.5 3.5 5.0
Power supply 1Ø, 220 - 240V, 50Hz
External Appearance
Model Names AUUW24GAE
[UU24W U44]
AUUW30GAE
[UU30W U44]
AUUW366D2
[UU36W UO2]
No. of connectable indoor
units 1
Total capacity index of
connectable indoor units(kW) 7.1 8.0 10.0
Power supply 1Ø, 220 - 240V, 50Hz
External Appearance
Model Names AUUW426D2
[UU42W U32]
AUUW486D2
[UU48W U32]
AUUW606D2
[UU60W U32]
No. of connectable indoor
units 1 ~ 4
Total capacity index of
connectable indoor units(kW) 12.5 14.0 15.0
Power supply 1Ø, 220 - 240V, 50Hz
External Appearance

1. Model Line Up
3
Single CAC Outdoor Unit General Information
3 Phase Inverter
Model Names AUUW368D2
[UU37W UO2]
No. of connectable indoor
units 1
Total capacity index of
connectable indoor units(kW) 10.0
Power supply 3Ø, 380 - 415V, 50Hz
External Appearance
Model Names AUUW428D2
[UU43W U32]
AUUW488D2
[UU49W U32]
AUUW608D2
[UU61W U32]
No. of connectable indoor
units 1 ~ 4
Total capacity index of
connectable indoor units(kW) 12.5 14.0 15.0
Power supply 3Ø, 380 - 415V, 50Hz
External Appearance
Model Names AUUW70LAE
[UU70W U34]
AUUW85LAE
[UU85W U74]
No. of connectable indoor
units 1 ~ 4
Total capacity index of
connectable indoor units(kW) 19.0 23.0
Power supply 3Ø, 380 - 415V, 50Hz
External Appearance

Single CAC Outdoor Unit
1. Model Line Up
4
General Information
1.2 Compact Inverter
Model Names AUUW18GC0
[UU18WC UL0]
AUUW24GC0
[UU24WC UE0]
No. of connectable indoor units 1
Nominal Capacity (kW) 4.7 6.8
Power supply 1Ø, 220 - 240V, 50Hz
External Appearance
Model Names AUUW30GC0
[UU30WC UE0]
AUUW36GC0
[UU36WC U40]
No. of connectable indoor units 1
Nominal Capacity (kW) 7.5 9.5
Power supply 1Ø, 220 - 240V, 50Hz
External Appearance

5
Single CAC Outdoor Unit General Information
2. Nomenclature
2.1 Outdoor units(Global)
2.2 Outdoor units(Europe)
Model Name AUU W 24 6 D 2
No.123456
No. Signification
1Indicates that this is a
R410A SINGLE A outdoor unit
2Model type
C : Cooling Only, H : Heat Pump, W: Inverter Heat Pump
3Capacity Code based on ‘kBtu/h’ units
4
Electrical rating
6:1Ø,220V-240V,50 Hz
8:3Ø,380V-415V,50 Hz
G: 1Ø, 220-240V, 50Hz / 1Ø, 220V, 60Hz
L : 3Ø, 380-415V,50Hz / 3Ø, 380V, 50Hz
5
Model Type
D, A : Standard
C : Compact
6Serial No.
Model Name U U 24 W U4 2
No.1234567
No. Signification
1Model type
U : Universal model
2Type
U : Outdoor units
3Cooling / heating capacity (kBtu/h)
4Model type
W : Inverter
5C: Compact
6Outdoor unit chassis name
7Serial number

Product Data
Single CAC
Outdoor Unit
FDF
Standard Inverter
Standard Inverter - Synchro
Compact Inverter

Standard Inverter
Single CAC
Outdoor Unit
FDF
1.List of Functions
2.Specifications
3.Dimensions
4.Piping Diagrams
5.Wiring Diagrams
6.Capacity Tables
7.Capacity Coefficient Factor
8.Operation Range
9.Electric Characteristics
10.Sound Levels

3
Single CAC Outdoor Unit Standard Inverter
1. List of Functions
1 Phase Inverter
Note
1. O : Applied, X : Not applied
Accessory model name : Installed at field, ordered and purchased separately by the corresponding model name, supplied with separate package.
• * : If outdoor side air temperature is low on cooling mode, outdoor unit controls the fan speed for continuous operation without the installation
of additional accessory.
Category Functions AUUW09GA0
[UU09W UL0]
AUUW12GA0
[UU12W UL0]
AUUW18GAE
[UU18W UE4]
Reliability
Defrost / Deicing O O O
High pressure switch X X X
Low pressure switch X X X
Phase protection X X X
Restart delay (3-minutes) O O O
Self diagnosis O O O
Soft start O O O
Convenience
Test function O O O
Night Silent Operation O O O
Peak Control X X O
Mode Lock X X O
Forced Cooling Operation
(Outdoor Unit) OOO
Network function Network solution(LGAP) X X O
ODU Dry Contact X X X
Device AUUW09GA0
[UU09W UL0]
AUUW12GA0
[UU12W UL0]
AUUW18GAE
[UU18W UE4]
Central
Controller
AC Ez (Simple Controller) X X PQCSZ250S0
AC Ez Touch X X PACEZA000
AC Smart IV X X PACS4B000
ACP IV X X PACP4B000
AC Manager IV X X PACM4B000
PI485 X X PMNFP14A1
Installation Y branch X X X
Header branch X X X
BNU (Building
Network Unit)
LONWORKS Gateway X X PLNWKB000
BACnet Gateway X X PQNFB17C0
Low Ambient Kit O (Logical operation*) O (Logical operation*) O (Logical operation*)

Single CAC Outdoor Unit
1. List of Functions
4
Standard Inverter
Note
1. O : Applied, X : Not applied
Accessory model name : Installed at field, ordered and purchased separately by the corresponding model name, supplied with separate package.
• * : If outdoor side air temperature is low on cooling mode, outdoor unit controls the fan speed for continuous operation without the installation
of additional accessory.
Category Functions AUUW24GAE
[UU24W U44]
AUUW30GAE
[UU30W U44]
AUUW366D2
[UU36W UO2]
Reliability
Defrost / Deicing O O O
High pressure switch X X X
Low pressure switch X X X
Phase protection X X X
Restart delay (3-minutes) O O O
Self diagnosis O O O
Soft start O O O
Convenience
Test function O O O
Night Silent Operation O O O
Peak Control O O X
Mode Lock O O X
Forced Cooling Operation
(Outdoor Unit) OOO
Network function Network solution(LGAP) O O O
ODU Dry Contact X X O (On/off control)
Device AUUW24GAE
[UU24W U44]
AUUW30GAE
[UU30W U44]
AUUW366D2
[UU36W UO2]
Central
Controller
AC Ez (Simple Controller) PQCSZ250S0 PQCSZ250S0 PQCSZ250S0
AC Ez Touch PACEZA000 PACEZA000 PACEZA000
AC Smart IV PACS4B000 PACS4B000 PACS4B000
ACP IV PACP4B000 PACP4B000 PACP4B000
AC Manager IV PACM4B000 PACM4B000 PACM4B000
PI485 PMNFP14A1 PMNFP14A1 PMNFP14A1
Installation Y branch X X Accessory
Header branch X X Accessory
BNU (Building
Network Unit)
LONWORKS Gateway PLNWKB000 PLNWKB000 PLNWKB000
BACnet Gateway PQNFB17C0 PQNFB17C0 PQNFB17C0
Low Ambient Kit O (Logical operation*) O (Logical operation*) O (Logical operation*)

1. List of Functions
5
Single CAC Outdoor Unit Standard Inverter
Note
1. O : Applied, X : Not applied
Accessory model name : Installed at field, ordered and purchased separately by the corresponding model name, supplied with separate package.
• * : If outdoor side air temperature is low on cooling mode, outdoor unit controls the fan speed for continuous operation without the installation
of additional accessory.
Category Functions AUUW426D2
[UU42W U32]
AUUW486D2
[UU48W U32]
AUUW606D2
[UU60W U32]
Reliability
Defrost / Deicing O O O
High pressure switch X X X
Low pressure switch X X X
Phase protection X X X
Restart delay (3-minutes) O O O
Self diagnosis O O O
Soft start O O O
Convenience
Test function O O O
Night Silent Operation O O O
Peak Control X X X
Mode Lock X X X
Forced Cooling Operation
(Outdoor Unit) OOO
Network function Network solution(LGAP) O O O
ODU Dry Contact O (On/off control) O (On/off control) O (On/off control)
Device AUUW426D2
[UU42W U32]
AUUW486D2
[UU48W U32]
AUUW606D2
[UU60W U32]
Central
Controller
AC Ez (Simple Controller) PQCSZ250S0 PQCSZ250S0 PQCSZ250S0
AC Ez Touch PACEZA000 PACEZA000 PACEZA000
AC Smart IV PACS4B000 PACS4B000 PACS4B000
ACP IV PACP4B000 PACP4B000 PACP4B000
AC Manager IV PACM4B000 PACM4B000 PACM4B000
PI485 PMNFP14A1 PMNFP14A1 PMNFP14A1
Installation Y branch Accessory Accessory Accessory
Header branch Accessory Accessory Accessory
BNU (Building
Network Unit)
LONWORKS Gateway PLNWKB000 PLNWKB000 PLNWKB000
BACnet Gateway PQNFB17C0 PQNFB17C0 PQNFB17C0
Low Ambient Kit O (Logical operation*) O (Logical operation*) O (Logical operation*)

Single CAC Outdoor Unit
1. List of Functions
6
Standard Inverter
3 Phase Inverter
Note
1. O : Applied, X : Not applied
Accessory model name : Installed at field, ordered and purchased separately by the corresponding model name, supplied with separate package.
• * : If outdoor side air temperature is low on cooling mode, outdoor unit controls the fan speed for continuous operation without the installation
of additional accessory.
Category Functions AUUW368D2
[UU37W UO2]
AUUW428D2
[UU43W U32]
AUUW488D2
[UU49W U32]
Reliability
Defrost / Deicing O O O
High pressure switch X X X
Low pressure switch X X X
Phase protection O O O
Restart delay (3-minutes) O O O
Self diagnosis O O O
Soft start O O O
Convenience
Test function O O O
Night Silent Operation O O O
Peak Control X X X
Mode Lock X X X
Forced Cooling Operation
(Outdoor Unit) OOO
Network function Network solution(LGAP) O O O
ODU Dry Contact O (On/off control) O (On/off control) O (On/off control)
Device AUUW368D2
[UU37W UO2]
AUUW428D2
[UU43W U32]
AUUW488D2
[UU49W U32]
Central
Controller
AC Ez (Simple Controller) PQCSZ250S0 PQCSZ250S0 PQCSZ250S0
AC Ez Touch PACEZA000 PACEZA000 PACEZA000
AC Smart IV PACS4B000 PACS4B000 PACS4B000
ACP IV PACP4B000 PACP4B000 PACP4B000
AC Manager IV PACM4B000 PACM4B000 PACM4B000
PI485 PMNFP14A1 PMNFP14A1 PMNFP14A1
Installation Y branch Accessory Accessory Accessory
Header branch Accessory Accessory Accessory
BNU (Building
Network Unit)
LONWORKS Gateway PLNWKB000 PLNWKB000 PLNWKB000
BACnet Gateway PQNFB17C0 PQNFB17C0 PQNFB17C0
Low Ambient Kit O (Logical operation*) O (Logical operation*) O (Logical operation*)

1. List of Functions
7
Single CAC Outdoor Unit Standard Inverter
Note
1. O : Applied, X : Not applied
Accessory model name : Installed at field, ordered and purchased separately by the corresponding model name, supplied with separate package.
• * : If outdoor side air temperature is low on cooling mode, outdoor unit controls the fan speed for continuous operation without the installation
of additional accessory.
Category Functions AUUW608D2
[UU61W U32]
AUUW70LAE
[UU70W U34]
AUUW85LAE
[UU85W U74]
Reliability
Defrost / Deicing O O O
High pressure switch X X X
Low pressure switch X X X
Phase protection O O O
Restart delay (3-minutes) O O O
Self diagnosis O O O
Soft start O O O
Convenience
Test function O O O
Night Silent Operation O O O
Peak Control X O O
Mode Lock X O O
Forced Cooling Operation
(Outdoor Unit) OOO
Network function Network solution(LGAP) O O O
ODU Dry Contact O (On/off control) O (On/off control) O (On/off control)
Device AUUW608D2
[UU61W U32]
AUUW70LAE
[UU70W U34]
AUUW85LAE
[UU85W U74]
Central
Controller
AC Ez (Simple Controller) PQCSZ250S0 PQCSZ250S0 PQCSZ250S0
AC Ez Touch PACEZA000 PACEZA000 PACEZA000
AC Smart IV PACS4B000 PACS4B000 PACS4B000
ACP IV PACP4B000 PACP4B000 PACP4B000
AC Manager IV PACM4B000 PACM4B000 PACM4B000
PI485 PMNFP14A1 PMNFP14A1 PMNFP14A1
Installation Y branch Accessory Accessory Accessory
Header branch Accessory Accessory Accessory
BNU (Building
Network Unit)
LONWORKS Gateway PLNWKB000 PLNWKB000 PLNWKB000
BACnet Gateway PQNFB17C0 PQNFB17C0 PQNFB17C0
Low Ambient Kit O (Logical operation*) O (Logical operation*) O (Logical operation*)

8
Single CAC Outdoor Unit Standard Inverter
2. Specifications
Combinational Specifiactions
1 Phase Inverter
Note
1. Due to our policy of innovation some specifications may be changed without notification.
2. Wiring cable size must comply with the applicable local and national codes. And “Electric characteristics” chapter should be considered for electrical
work and design. Especially the power cable and circuit breaker should be selected in accordance with that.
3. Power factor could vary less than ±1% according to the operating conditions.
4. Sound pressure level is measured on the rated condition in the anechoic rooms by ISO 3745 standard.
Sound power levIndoorel is measured on the rated condition in the reverberation rooms by ISO 3741 standard.
Therefore, these values can be increased owing to ambient conditions during operation.
5. Performances are based on the following conditions :
• *Cooling : Indoor Ambient Temp. 27°CDB / 19°CWB, Outdoor Ambient Temp. 35°CDB / 24°CWB
• *Heating : Indoor Ambient Temp. 20°CDB / 15°CWB, Outdoor Ambient Temp. 7°CDB / 6°CWB
• Interconnected Pipe is standard length and difference of Elevation (Outdoor ~ Indoor Unit) is Zero.
6. This product contains Fluorinated greenhouse gases.
Combination
Outdoor unit AUUW09GA0
[UU09W UL0]
AUUW09GA0
[UU09W UL0]
Indoor unit ATNH09GRLE2
[CT09 NR2]
ABNW09GL2A2
[CB09L N22]
Capacity
Cooling Min.~Rated~Max. kW 1.00 ~ 2.50 ~ 2.75 1.10 ~ 2.50 ~ 2.90
Min.~Rated~Max. Btu/h 3,400 ~ 8,500 ~ 9,400 3,800 ~ 8,500 ~ 9,900
Heating Min.~Rated~Max. kW 1.20 ~ 3.00 ~ 3.30 1.20 ~ 3.20 ~ 3.60
Min.~Rated~Max. Btu/h 4,100 ~ 10,200 ~ 11,300 4,100 ~ 10,900 ~ 12,300
Power Input Cooling Rated kW 0.625 0.660
Heating Rated kW 0.800 0.800
Running Current Cooling Rated A 2.70 2.90
Heating Rated A 3.50 3.50
SEER / SCOP Wh / Wh 6.44 / 4.00 6.28 / 4.00
Seasonal Energy Label
(A++ to E Scale) Cooling / Heating - A++ / A+ A++ / A+
Annual Energy Consumption Cooling / Heating kWh 136 / 980 139 / 1,050
Combination
Outdoor unit AUUW09GA0
[UU09W UL0]
AUUW09GA0
[UU09W UL0]
Indoor unit AVNH09GELA2
[CV09 NE2]
AQNH09GALA0
[CQ09 NA0]
Capacity
Cooling Min.~Rated~Max. kW 1.00 ~ 2.50 ~ 2.75 1.30 ~ 2.55 ~ 2.80
Min.~Rated~Max. Btu/h 3,400 ~ 8,500 ~ 9,400 4,400 ~ 8,700 ~ 9,600
Heating Min.~Rated~Max. kW 1.20 ~ 3.00 ~ 3.30 1.36 ~ 3.10 ~ 3.40
Min.~Rated~Max. Btu/h 4,100 ~ 10,200 ~ 11,300 4,600 ~ 10,600 ~ 11,600
Power Input Cooling Rated kW 0.700 0.700
Heating Rated kW 0.830 0.840
Running Current Cooling Rated A 3.10 3.10
Heating Rated A 3.60 3.70
SEER / SCOP Wh / Wh 5.87 / 3.81 5.60 / 3.81
Seasonal Energy Label
(A++ to E Scale) Cooling / Heating - A+ / A A+ / A
Annual Energy Consumption Cooling / Heating kWh 149 / 1,029 159 / 1,029

2. Specifications
9
Single CAC Outdoor Unit Standard Inverter
Note
1. Due to our policy of innovation some specifications may be changed without notification.
2. Wiring cable size must comply with the applicable local and national codes. And “Electric characteristics” chapter should be considered for electrical
work and design. Especially the power cable and circuit breaker should be selected in accordance with that.
3. Power factor could vary less than ±1% according to the operating conditions.
4. Sound pressure level is measured on the rated condition in the anechoic rooms by ISO 3745 standard.
Sound power levIndoorel is measured on the rated condition in the reverberation rooms by ISO 3741 standard.
Therefore, these values can be increased owing to ambient conditions during operation.
5. Performances are based on the following conditions :
• *Cooling : Indoor Ambient Temp. 27°CDB / 19°CWB, Outdoor Ambient Temp. 35°CDB / 24°CWB
• *Heating : Indoor Ambient Temp. 20°CDB / 15°CWB, Outdoor Ambient Temp. 7°CDB / 6°CWB
• Interconnected Pipe is standard length and difference of Elevation (Outdoor ~ Indoor Unit) is Zero.
6. This product contains Fluorinated greenhouse gases.
Combination
Outdoor unit AUUW12GA0
[UU12W UL0]
AUUW12GA0
[UU12W UL0]
Indoor unit ATNH12GRLE2
[CT12 NR2]
ABNH12GL2A2
[CB12L N22]
Capacity
Cooling Min.~Rated~Max. kW 1.36 ~ 3.40 ~ 3.74 1.40 ~ 3.40 ~ 3.70
Min.~Rated~Max. Btu/h 4,600 ~ 11,600 ~ 12,800 4,800 ~ 11,600 ~ 12,600
Heating Min.~Rated~Max. kW 1.60 ~ 4.00 ~ 4.40 1.60 ~ 4.00 ~ 4.50
Min.~Rated~Max. Btu/h 5,500 ~ 13,600 ~ 15,000 5,500 ~ 13,600 ~ 15,400
Power Input Cooling Rated kW 0.970 0.950
Heating Rated kW 1.150 1.050
Running Current Cooling Rated A 4.30 4.20
Heating Rated A 5.00 4.60
SEER / SCOP Wh / Wh 6.46 / 4.10 6.28 / 4.00
Seasonal Energy Label
(A++ to E Scale) Cooling / Heating - A++ / A+ A++ / A+
Annual Energy Consumption Cooling / Heating kWh 184 / 1,024 189 / 1,050
Combination
Outdoor unit AUUW12GA0
[UU12W UL0]
AUUW12GA0
[UU12W UL0]
Indoor unit AVNH12GELA2
[CV12 NE2]
AQNH12GALA0
[CQ12 NA0]
Capacity
Cooling Min.~Rated~Max. kW 1.32 ~ 3.30 ~ 3.63 1.36 ~ 3.50 ~ 3.74
Min.~Rated~Max. Btu/h 4,500 ~ 11,300 ~ 12,400 4,600 ~ 11,900 ~ 12,800
Heating Min.~Rated~Max. kW 1.52 ~ 3.80 ~ 4.30 1.60 ~ 4.00 ~ 4.40
Min.~Rated~Max. Btu/h 5,200 ~ 13,000 ~ 14,700 5,500 ~ 13,600 ~ 15,000
Power Input Cooling Rated kW 1.030 1.090
Heating Rated kW 1.180 1.210
Running Current Cooling Rated A 4.50 4.80
Heating Rated A 5.10 5.30
SEER / SCOP Wh / Wh 6.28 / 3.81 5.60 / 3.81
Seasonal Energy Label
(A++ to E Scale) Cooling / Heating - A++ / A A+ / A
Annual Energy Consumption Cooling / Heating kWh 184 / 1,029 219 / 1,102

Single CAC Outdoor Unit
2. Specifications
10
Standard Inverter
Note
1. Due to our policy of innovation some specifications may be changed without notification.
2. Wiring cable size must comply with the applicable local and national codes. And “Electric characteristics” chapter should be considered for electrical
work and design. Especially the power cable and circuit breaker should be selected in accordance with that.
3. Power factor could vary less than ±1% according to the operating conditions.
4. Sound pressure level is measured on the rated condition in the anechoic rooms by ISO 3745 standard.
Sound power levIndoorel is measured on the rated condition in the reverberation rooms by ISO 3741 standard.
Therefore, these values can be increased owing to ambient conditions during operation.
5. Performances are based on the following conditions :
• *Cooling : Indoor Ambient Temp. 27°CDB / 19°CWB, Outdoor Ambient Temp. 35°CDB / 24°CWB
• *Heating : Indoor Ambient Temp. 20°CDB / 15°CWB, Outdoor Ambient Temp. 7°CDB / 6°CWB
• Interconnected Pipe is standard length and difference of Elevation (Outdoor ~ Indoor Unit) is Zero.
6. This product contains Fluorinated greenhouse gases.
Combination
Outdoor unit AUUW18GAE
[UU18W UE4]
AUUW18GAE
[UU18W UE4]
Indoor unit ATNW18GQLA0
[CT18 NQ4]
ABNW18GM1A0
[CM18 N14]
Capacity
Cooling Min.~Rated~Max. kW 2.00 ~ 5.00 ~ 5.50 1.80 ~ 5.00 ~ 6.00
Min.~Rated~Max. Btu/h 6,800 ~ 17,100 ~ 18,700 6,100 ~ 17,100 ~ 20,500
Heating Min.~Rated~Max. kW 2.20 ~ 5.80 ~ 6.80 2.20 ~ 6.00 ~ 7.20
Min.~Rated~Max. Btu/h 7,500 ~ 19,800 ~ 23,200 7,500 ~ 20,500 ~ 24,600
Power Input Cooling Rated kW 1.56 1.46
Heating Rated kW 1.66 1.66
Running Current Cooling Rated A 7.10 6.50
Heating Rated A 7.50 7.60
SEER / SCOP Wh / Wh 6.10 / 4.25 6.10 / 4.15
Seasonal Energy Label
(A++ to E Scale) Cooling / Heating - A++ / A+ A++ / A+
Annual Energy Consumption Cooling / Heating kWh 287 / 1,351 287 / 1,383
Combination
Outdoor unit AUUW18GAE
[UU18W UE4]
Indoor unit ABNH18GL2A2
[CB18 N22]
Capacity
Cooling Min.~Rated~Max. kW 2.00 ~ 5.00 ~ 6.00
Min.~Rated~Max. Btu/h 6,800 ~ 17,100 ~ 20,500
Heating Min.~Rated~Max. kW 2.20 ~ 6.00 ~ 7.20
Min.~Rated~Max. Btu/h 7,500 ~ 20,500 ~ 24,600
Power Input Cooling Rated kW 1.55
Heating Rated kW 1.50
Running Current Cooling Rated A 6.80
Heating Rated A 8.40
SEER / SCOP Wh / Wh 6.10 / 3.95
Seasonal Energy Label
(A++ to E Scale) Cooling / Heating - A++ / A
Annual Energy Consumption Cooling / Heating kWh 287 / 1,418
Combination
Outdoor unit AUUW18GAE
[UU18W UE4]
AUUW18GAE
[UU18W UE4]
Indoor unit UVNH18GJLA2
[CV18 NJ2]
AQNH18GALA0
[CQ18 NA0]
Capacity
Cooling Min.~Rated~Max. kW 1.92 ~ 5.00 ~ 5.80 2.20 ~ 5.00 ~ 5.60
Min.~Rated~Max. Btu/h 6,500 ~ 17,100 ~ 19,800 7,500 ~ 17,100 ~ 19,100
Heating Min.~Rated~Max. kW 2.00 ~ 5.20 ~ 6.00 2.20 ~ 4.80 ~ 5.80
Min.~Rated~Max. Btu/h 6,800 ~ 17,700 ~ 20,500 7,500 ~ 16,400 ~ 19,800
Power Input Cooling Rated kW 1.46 1.55
Heating Rated kW 1.53 1.50
Running Current Cooling Rated A 6.70 7.00
Heating Rated A 6.90 6.90
SEER / SCOP Wh / Wh 6.10 / 4.15 6.20 / 3.81
Seasonal Energy Label
(A++ to E Scale) Cooling / Heating - A++ / A+ A++ / A
Annual Energy Consumption Cooling / Heating kWh 287 / 1,349 282 / 1,396

2. Specifications
11
Single CAC Outdoor Unit Standard Inverter
Note
1. Due to our policy of innovation some specifications may be changed without notification.
2. Wiring cable size must comply with the applicable local and national codes. And “Electric characteristics” chapter should be considered for electrical
work and design. Especially the power cable and circuit breaker should be selected in accordance with that.
3. Power factor could vary less than ±1% according to the operating conditions.
4. Sound pressure level is measured on the rated condition in the anechoic rooms by ISO 3745 standard.
Sound power levIndoorel is measured on the rated condition in the reverberation rooms by ISO 3741 standard.
Therefore, these values can be increased owing to ambient conditions during operation.
5. Performances are based on the following conditions :
• *Cooling : Indoor Ambient Temp. 27°CDB / 19°CWB, Outdoor Ambient Temp. 35°CDB / 24°CWB
• *Heating : Indoor Ambient Temp. 20°CDB / 15°CWB, Outdoor Ambient Temp. 7°CDB / 6°CWB
• Interconnected Pipe is standard length and difference of Elevation (Outdoor ~ Indoor Unit) is Zero.
6. This product contains Fluorinated greenhouse gases.
Combination
Outdoor unit AUUW24GAE
[UU24W U44]
AUUW24GAE
[UU24W U44]
Indoor unit ATNW24GPLA0
[CT24 NP4]
ABNW24GM1A0
[CM24 N14]
Capacity
Cooling Min.~Rated~Max. kW 2.84 ~ 6.80 ~ 7.80 2.80 ~ 6.80 ~ 7.48
Min.~Rated~Max. Btu/h 9,700 ~ 23,200 ~ 26,600 9,500 ~ 23,200 ~ 25,500
Heating Min.~Rated~Max. kW 3.20 ~ 8.00 ~ 8.80 3.20 ~ 7.50 ~ 8.25
Min.~Rated~Max. Btu/h 10,900 ~ 27,300 ~ 30,000 10,900 ~ 25,600 ~ 28,100
Power Input Cooling Rated kW 2.00 2.07
Heating Rated kW 2.22 2.34
Running Current Cooling Rated A 8.90 9.10
Heating Rated A 9.70 10.30
SEER / SCOP Wh / Wh 6.80 / 4.20 6.10 / 3.90
Seasonal Energy Label
(A++ to E Scale) Cooling / Heating - A++ / A+ A++ / A
Annual Energy Consumption Cooling / Heating kWh 350 / 2,110 390 / 2,154
Combination
Outdoor unit AUUW24GAE
[UU24W U44]
AUUW24GAE
[UU24W U44]
Indoor unit ABNH24GL3A2
[CB24L N32]
UVNH24GJLA2
[CV24 NJ2]
Capacity
Cooling Min.~Rated~Max. kW 4.00 ~ 7.10 ~ 7.70 2.80 ~ 6.80 ~ 7.48
Min.~Rated~Max. Btu/h 13,600 ~ 24,200 ~ 26,300 9,500 ~ 23,200 ~ 25,500
Heating Min.~Rated~Max. kW 2.00 ~ 7.50 ~ 8.25 3.08 ~ 7.50 ~ 8.25
Min.~Rated~Max. Btu/h 6,800 ~ 25,600 ~ 28,100 10,500 ~ 25,600 ~ 28,100
Power Input Cooling Rated kW 2.36 2.25
Heating Rated kW 2.05 2.45
Running Current Cooling Rated A 10.4 9.90
Heating Rated A 9.00 10.8
SEER / SCOP Wh / Wh 5.60 / 3.90 5.80 / 3.90
Seasonal Energy Label
(A++ to E Scale) Cooling / Heating - A+ / A A+ / A
Annual Energy Consumption Cooling / Heating kWh 444 / 2,082 410 / 2,154

Single CAC Outdoor Unit
2. Specifications
12
Standard Inverter
Note
1. Due to our policy of innovation some specifications may be changed without notification.
2. Wiring cable size must comply with the applicable local and national codes. And “Electric characteristics” chapter should be considered for electrical
work and design. Especially the power cable and circuit breaker should be selected in accordance with that.
3. Power factor could vary less than ±1% according to the operating conditions.
4. Sound pressure level is measured on the rated condition in the anechoic rooms by ISO 3745 standard.
Sound power levIndoorel is measured on the rated condition in the reverberation rooms by ISO 3741 standard.
Therefore, these values can be increased owing to ambient conditions during operation.
5. Performances are based on the following conditions :
• *Cooling : Indoor Ambient Temp. 27°CDB / 19°CWB, Outdoor Ambient Temp. 35°CDB / 24°CWB
• *Heating : Indoor Ambient Temp. 20°CDB / 15°CWB, Outdoor Ambient Temp. 7°CDB / 6°CWB
• Interconnected Pipe is standard length and difference of Elevation (Outdoor ~ Indoor Unit) is Zero.
6. This product contains Fluorinated greenhouse gases.
Combination
Outdoor unit AUUW30GAE
[UU30W U44]
AUUW30GAE
[UU30W U44]
Indoor unit ATNW30GPLA0
[UT30 NP4]
ABNW30GM1A0
[UM30 N14]
Capacity
Cooling Min.~Rated~Max. kW 3.20 ~ 8.00 ~ 8.80 3.20 ~ 7.80 ~ 8.80
Min.~Rated~Max. Btu/h 10,900 ~ 27,300 ~ 30,000 10,900 ~ 26,600 ~ 30,000
Heating Min.~Rated~Max. kW 3.60 ~ 9.00 ~ 9.90 3.60 ~ 9.00 ~ 9.90
Min.~Rated~Max. Btu/h 12,300 ~ 30,700 ~ 33,800 12,300 ~ 30,700 ~ 33,800
Power Input Cooling Rated kW 2.49 2.41
Heating Rated kW 2.72 2.62
Running Current Cooling Rated A 10.80 10.10
Heating Rated A 11.80 10.70
SEER / SCOP Wh / Wh 6.30 / 4.00 6.10 / 4.00
Seasonal Energy Label
(A++ to E Scale) Cooling / Heating - A++ / A+ A++ / A+
Annual Energy Consumption Cooling / Heating kWh 444 / 2,380 448 / 2,275
Combination
Outdoor unit AUUW30GAE
[UU30W U44]
AUUW30GAE
[UU30W U44]
Indoor unit UVNH30GJLA2
[UV30 NJ2]
AJNW30GVLA0
[UJ30 NV2]
Capacity
Cooling Min.~Rated~Max. kW 3.04 ~ 7.60 ~ 8.40 3.50 ~ 7.80 ~ 8.50
Min.~Rated~Max. Btu/h 10,400 ~ 25,900 ~ 28,600 11,900 ~ 26,600 ~ 29,000
Heating Min.~Rated~Max. kW 3.36 ~ 8.20 ~ 9.24 4.00 ~ 8.40 ~ 9.20
Min.~Rated~Max. Btu/h 11,500 ~ 28,000 ~ 31,500 13,600 ~ 28,700 ~ 31,400
Power Input Cooling Rated kW 2.52 2.29
Heating Rated kW 2.72 2.46
Running Current Cooling Rated A 11.00 10.00
Heating Rated A 11.80 10.70
SEER / SCOP Wh / Wh 5.61 / 3.90 6.11 / 3.91
Seasonal Energy Label
(A++ to E Scale) Cooling / Heating - A+ / A A++ / A
Annual Energy Consumption Cooling / Heating kWh 474 / 2,262 448 / 2,262

2. Specifications
13
Single CAC Outdoor Unit Standard Inverter
Note
1. Due to our policy of innovation some specifications may be changed without notification.
2. Wiring cable size must comply with the applicable local and national codes. And “Electric characteristics” chapter should be considered for electrical
work and design. Especially the power cable and circuit breaker should be selected in accordance with that.
3. Power factor could vary less than ±1% according to the operating conditions.
4. Sound pressure level is measured on the rated condition in the anechoic rooms by ISO 3745 standard.
Sound power levIndoorel is measured on the rated condition in the reverberation rooms by ISO 3741 standard.
Therefore, these values can be increased owing to ambient conditions during operation.
5. Performances are based on the following conditions :
• *Cooling : Indoor Ambient Temp. 27°CDB / 19°CWB, Outdoor Ambient Temp. 35°CDB / 24°CWB
• *Heating : Indoor Ambient Temp. 20°CDB / 15°CWB, Outdoor Ambient Temp. 7°CDB / 6°CWB
• Interconnected Pipe is standard length and difference of Elevation (Outdoor ~ Indoor Unit) is Zero.
6. This product contains Fluorinated greenhouse gases.
Combination
Outdoor unit AUUW366D2
[UU36W UO2]
AUUW366D2
[UU36W UO2]
Indoor unit ATNH36GNLE2
[UT36 NN2]
ABNW36GM2A0
[UM36 N24]
Capacity
Cooling Min.~Rated~Max. kW 4.00 ~ 10.0 ~ 11.0 4.00 ~ 10.0 ~ 11.0
Min.~Rated~Max. Btu/h 13,600 ~ 34,100 ~ 37,500 13,600 ~ 34,100 ~ 37,500
Heating Min.~Rated~Max. kW 4.40 ~ 11.0 ~ 12.1 4.50 ~ 11.2 ~ 12.3
Min.~Rated~Max. Btu/h 15,000 ~ 37,500 ~ 41,300 15,400 ~ 38,200 ~ 42,000
Power Input Cooling Rated kW 2.82 3.12
Heating Rated kW 3.09 3.19
Running Current Cooling Rated A 12.30 13.60
Heating Rated A 13.40 13.90
SEER / SCOP Wh / Wh 5.41 / 3.81 5.11 / 3.81
Seasonal Energy Label
(A++ to E Scale) Cooling / Heating - A / A A / A
Annual Energy Consumption Cooling / Heating kWh 648 / 2,800 685 / 2,866
Combination
Outdoor unit AUUW366D2
[UU36W UO2]
AUUW366D2
[UU36W UO2]
Indoor unit UVNH36GKLA2
[UV36 NK2]
AJNW36GVLA1
[UJ36 NV3]
Capacity
Cooling Min.~Rated~Max. kW 3.80 ~ 9.50 ~ 10.5 4.00 ~ 9.50 ~ 10.50
Min.~Rated~Max. Btu/h 13,000 ~ 32,400 ~ 35,800 13,600 ~ 32,400 ~ 35,800
Heating Min.~Rated~Max. kW 4.20 ~ 10.5 ~ 11.6 4.40 ~ 10.50 ~ 11.50
Min.~Rated~Max. Btu/h 14,300 ~ 35,800 ~ 39,600 15,000 ~ 35,800 ~ 39,200
Power Input Cooling Rated kW 2.78 2.79
Heating Rated kW 3.08 3.27
Running Current Cooling Rated A 12.10 12.10
Heating Rated A 13.40 13.40
SEER / SCOP Wh / Wh 5.11 / 3.81 5.41 / 3.81
Seasonal Energy Label
(A++ to E Scale) Cooling / Heating - A / A A / A
Annual Energy Consumption Cooling / Heating kWh 652 / 2,800 615 / 2,505
This manual suits for next models
36
Table of contents
Other LG Air Conditioner manuals

LG
LG CEILING CONCEALED DUCT User manual

LG
LG W122CA TSC4 User manual

LG
LG Multi V miniARUN Series User manual

LG
LG LSNC1264DM1 User manual

LG
LG LZ-H050GXH0 User manual

LG
LG ZBNQ09GL1A0 Product guide

LG
LG LPC483TAO User manual

LG
LG VP182CR NKM3 User manual

LG
LG LP6011ER User manual

LG
LG ARUB076BT2 User manual
Popular Air Conditioner manuals by other brands

Gree
Gree GWH09AB-D3DNA1D/I Service manual

Bard
Bard THE WALL-MOUNT WA3S3-A installation instructions

Daikin
Daikin FAQ71CVEB installation manual

Daikin
Daikin Super Multi NX 3MKS50E3V1B Service manual

dirna Bergstrom
dirna Bergstrom bycool green Series Troubleshooting

Frigidaire
Frigidaire FFRE153WA1 Use & care guide