LG V-NET PLNWKB000 Instruction Manual

P/NO : MFL67842102 www.lg.com
INSTALLATION/USER MANUAL
TYPE : ACP Lonworks (ACP Lonworks Gateway)
MODEL : PLNWKB000, PLNWKB100
• Make sure to read the cautions for safety before installation and use, and use
it correctly.
• It is intended to keep protect the safety of the installer and user and to
prevent the property damage, etc.
• After reading the user manual, please keep it at a place where user can
access any time.
ENGLISH

• Do not cool excessively indoors. This may be harmful for your health and may consume more
electricity.
• Block sunlight with blinds or curtains while you are operating the air conditioner.
• Keep doors or windows closed tightly while you are operating the air conditioner.
• Adjust the direction of the air flow vertically or horizontally to circulate indoor air.
• Speed up the fan to cool or warm indoor air quickly, in a short period of time.
• Open windows regularly for ventilation as the indoor air quality may deteriorate if the air condition-
er is used for many hours.
• Clean the air filter once every 2 weeks. Dust and impurities collected in the air filter may block the
air flow or weaken the cooling / dehumidifying functions.
For your records
Staple your receipt to this page in case you need it to prove the date of purchase or for warranty
purposes. Write the model number and the serial number here:
Model number :
Serial number :
You can find them on a label on the side of each unit.
Dealer’s name :
Date of purchase :
Here are some tips that will help you minimize the power consumption when you use the air
conditioner. You can use your air conditioner more efficiently by referring to the instructions
below:
TIPS FOR SAVING ENERGY
ENGLISH
TIPS FOR SAVING ENERGY
2
NOTE
!
• Lonworks Gateway (Following referred as ACP Lonworks)
ACP Lonworks-Free Volt (PLNWKB000)
ACP Lonworks-AC24V (PLNWKB100)

3
IMPORTANT SAFETY INSTRUCTIONS
READ ALL INSTRUCTIONS BEFORE USING THE APPLIANCE.
Always comply with the following precautions to avoid dangerous situations and ensure peak
performance of your product
WARNING
It can result in serious injury or death when the directions are ignored
CAUTION
It can result in minor injury or product damage when the directions are ignored
WARNING
• Installation or repairs made by unqualified persons can result in hazards to you and others.
• Installation MUST conform with local building codes or, in the absence of local codes, with
the Nation Electrical Code NFPA 70/ANSI C1-1003 or current edition and Canadian Electrical
Code Part1 CSA C.22.1.
• The information contained in the manual is intended for use by a qualified service technician
familiar with safety procedures and equipped with the proper tools and test instruments.
• Failure to carefully read and follow all instructions in this manual can result in equipment mal-
function, property damage, personal injury and/or death.
Installation
• Any question about the product installation should be asked to the service center or the professional
installation agency.
- It may cause fire, electric shock, explosion or injury.
•
Consult the service center or the professional installation agency about reinstalling the installed product.
- It may cause fire, electric shock, explosion or injury.
• Please use the standardized parts.
- It may cause fire, electric shock, explosion, injury, or failure.
• Do not keep or use combustible gas or inflammable material near the product.
- IT may cause fire or electric shock.
• Do not disassemble, repair or modify the product at random.
- It may cause failure of the product.
• Do not install where raindrop can fall.
- It may cause failure of the product.
• Do not install the product at wet place.
- It may cause failure of the product.
• Provided product and adaptor shall only be installed and used inside a building.
- It may cause fire or failure of the product.
*Do not install or use outside.
• Install stably in a place that can endure the weight of the ACP Lonworks.
- If the installation place is not strong enough, the ACP Lonworks may fall and damaged.
•
Make sure to enquire to the specialty store of the product purchase or service center for electric works.
- It may cause fire or electric shock.
• Do not damage the power cord or bend it by force.
- It may cause fire or electric shock.
• You need to use a safely insulated power supply which follows IEC61558-2-6 and NEC Class2
- If you do not follow, It may cause fire, electric shock, explosion or injury.
• Do not connetion 220V power to 24V products
- If you do not follow, It may cause fire, electric shock, explosion or injury.
!
!
!
ENGLISH
IMPORTANT SAFETY INSTRUCTIONS

• Do not connect power cord to the control signal connector.
- It may cause fire or explosion.
Operation
• Do not change or extend the power cord with your own discretion.
- It may cause fire or electric shock
• Do not place any heating device near the product.
- It may cause fire.
• Do not use any heating device near the power cord.
- It may cause fire or electric shock.
• Do not let water flow into the product.
- It may cause electric shock or failure.
• Do not put heavy weight on the power cord.
- It may cause fire or electric shock.
• Do not put heavy weight on the product.
- It may cause the failure of the product.
• If the product is flooded, consult the service center or the professional installation agency.
- It may cause fire or electric shock.
• Let the children or the old and the weak be controlled by the guardian to use.
- It may cause accident or failure.
• Do not give any shock to the product.
- Any shock to the product may cause failure.
• Grab the head of the plug of the power cord to pull when disconnecting the plug, and do not touch
the plug with wet hands.
- It may cause fire or to deform the product.
• Do not use the product in certain environments as follows.
- If the product is used in a place with oil, steam, or sulfuric acid gas, performance may be degraded
or product may be damaged.
• Do not press the switch or button with sharp objects.
- It may cause electric shock or failure of the product.
• Please check the operation temperature.
- If the product is used in an environment with the temperature exceeding the operation boundary, it
may cause a severe damage.
Please check the usage temperature boundary in the manual. If there is no specified temperature,
please use the product within the boundary of 0~40°C.
• Do not put a container, etc. with water on the product.
- It may cause fire or electric shock.
• Do not touch the switch with wet hand.
- It may cause electric shock or failure of the product.
• Please read installation and user manual for connection with PC or peripheral devices.
- It may cause fire or failure of the product.
• If a warning window appears on PC, product stops, or it does not work, immediately stop the usage.
- It may cause fire or failure of the product.
• When doing service work or cleaning, please shut off the power to the equipment always.
- It causes the deformation of the product or fire.
CAUTION
Operation
• Do not use strong detergent such as solvent, but a soft cloth.
- It may cause fire or to deform the product.
• Please check the rated capacity of the power.
- It may cause fire or failure of the product.
!
ENGLISH
SAFETY PRECAUTIONS
4

5
TABLE OF CONTENTS
ENGLISH
TABLE OF CONTENTS
2TIPS FOR SAVING ENERGY
3IMPORTANT SAFETY
INSTRUCTIONS
6ACP LONWORKS FUNC-
TIONS AND SPECIFICATION
6 ACP Lonworks Functions
8 ACP Lonworks Components
9 Names of each part of ACP Lonworks
11 ACP Lonworks Hardware Specification
12 Operating ACP Lonworks with
ACCS
12 Review the initial ACCS screen
15 Controlling the Equipments
23 Ventilation Control Screen and unique features
24 AWHP Control Screen and unique features
25 AHU Control Screen and unique features
26 Chiller Control Screen and unique features
27 Setting the schedule
33 Controlling the peak operation ratio
34 Indoor unit priority control method
37 Outdoor unit capacity control method
40 Controlling demand power
41 Indoor unit priority control method
43 Outdoor unit capacity control method
46 Monitoring the equipment status
48 Reviewing the Error Log
51 Reviewing the power (power display interface)
54 Setting the system
63 Indoor unit priority control setting
64 Outdoor unit capacity control setting
68 Additional functions
69 Installing ACP Lonworks
69 Installing ACP Lonworks
70 Check points during the ACP Lonworks instal-
lation
71 Setting the indoor unit address
72 Setting the PI485 and connecting the cable
74 Installing ACP Lonworks and connecting
cables
75 Installing the ACP Lonworks in DIN RAIL
76 Connecting RS-485 cable to the ACP
Lonworks
76 Fixing the ACP Lonworks to the wall
78 Connecting Ethernet cable (LAN cable) to the
ACP Lonworks
79 Connecting LON communication cable(TP/FT-
10) of ACP Lonworks.
80 Before configuring the ACP Lonworks environ-
ment
80 Setting the ACP Lonworks network address
82 Entering into the environment setup mode
83 How to set network address
85 Setting IP address
86 Using dynamic IP using DHCP
87 Checking ACP Lonworks access
89 Selecting Peak or Demand
89 Setting the functions of the ACP Lonworks
89 Before setting the functions of the ACP
Lonworks
91 Selecting ACCS display language
92 Setting whether to use schedule function
94 Setting whether to use the power display
function
95 Setting whether to display error history
96 Setting whether to display cycle information
97 Setting whether to use FireAlarm function
98 Setting whether to use air conditioner 0.5°C
control function
98 Setting whether to use CH6 function
99 Software service function
99 Software update
102 Data backup
104 Data recovery
106 RS-485 data logging
107 Setting the module type of the ACP Lonworks
107 Before setting the module type of the ACP
Lonworks
108 Display the module type setting information
109 Accessing ACP Lonworks
114 Input indoor/outdoor unit and ventilation
equipment information
114 When ACP Lonworks is connected to AC
Manager
115 When ACP Lonworks is not connected to AC
Manager
119 Verifying and checking the ACP Lonworks
installation
121 Connecting with Lonworks BMS
122 NOTES
122 Troubleshooting
126 Guide to Open Source Software
127 Function Block
136 Control/Monitoring Point List
148 Network Variables
Ver 1.0.0

6ACP LONWORKS FUNCTIONS AND SPECIFICATION
ENGLISH
ACP Lonworks(ACP Lonworks Gateway) is the central controller that can manage up to 64 equip-
ments in one space individually or as combined.
- In case of air conditioner indoor unit, up to 64 indoor units
- In case of AHU unit, up to 16 units
- In case of Chiller unit, up to 15 units
hIt is required a separate ACP Lonworks for each other product type(air conditioner, AHU or
Chiller). ACP Lonworks can't to connect air conditioner indoor unit, AHU unit or Chiller unit at
the same time.
ACP Lonworks Functions
Major functions of the ACP Lonworks are as follows.
Environment setting function using the ACP Lonworks external buttons
ACP Lonworks can use the external buttons installed outside of the ACP Lonworks to set the fol-
lowing functions.
- Set Network environment (IP address, Net mask, Gateway)
- Set the function to use between Peak/demand function
- Set the language to use in LG ACCS screen
- Set whether to use schedule function
- Set whether to use integrated power function
- Decide whether to use error history display function
- Decide whether to display outdoor freezing cycle related information
- SW upgrade function
- Data backup function
- Data recovery function
- RS-485 communication logging function
- Set CH6 for chiller interface
- Set the module type
PLNWKB000
PLNWKB000
ACP LONWORKS FUNCTIONS AND SPECIFICATION

ACP LONWORKS FUNCTIONS AND SPECIFICATION
ENGLISH
7
Embedded web server function
Without an installation of a separate PC program, when IP address of ACP Lonworks is input in
the address window using Internet Explorer, the central control program in ACP Lonworks web
server is automatically run, and the functions of various contents can be used.
Devices that can interface with ACP Lonworks
- Controlling of up to 64 air conditioner indoor
units
- Monitoring of error and operation status
- Controlling the peak power / demand power
- System setting function
PLNWKB000
P\\X"!
Internet
Explorer
Internet
Device ACP Lonworks
AC Ez O
AC Smart Premium O
AC Manager Plus O
Air Conditioner O
Ventilation O
AWHP O
Fire Alarm O
Chiller O
AHU O

8ACP Lonworks FUNCTIONS AND SPECIFICATION
ENGLISH
ACP Lonworks Components
Inside the packaged box of the ACP Lonworks, there are the components as in the following
drawing. Open the packaged box of the ACP Lonworks, and check if all of the corresponding
components are included.
NOTE
!
• May be different from the image that has been shown and items sold separately parts.
• Power Supply Adaptor and Power Cord are not included in PLNWKB100 (AC24V power use)
PLNWKB000
ACP Lonworks
(ACP Lonworks Gateway) Quick Guide
Power Supply Adaptor
Input: 100~240V
50/60Hz 1.2A
Output: DC 12V
3.33A, 40W MAX
Power Cord
250V AC, 3A
ACP Lonworks
User’s Guide
P/NO : MFL67842102
www.lg.com
INSTALLATION/USER MANUAL
TYPE : ACP Lonworks (ACP Lonworks Gateway)
MODEL : PLNWKB000, PLNWKB100
• Make sure to read the cautions for safety before installation and use, and use
it correctly.
• It is intended to keep protect the safety of the installer and user and to
prevent the property damage, etc.
• After reading the user manual, please keep it at a place where user can
access any time.

ACP LONWORKS FUNCTIONS AND SPECIFICATION
ENGLISH
9
Names of each part of ACP Lonworks
ACP Lonworks is composed as follows.
NOTE
!
• No. 3 and No. 4 may be different for each model.
1
3
PLNWKB000
7
6
8
5
9
11 12 13
10
4
2

10 ACP LONWORKS FUNCTIONS AND SPECIFICATION
ENGLISH
1 Cover
Front cover of the ACP Lonworks
2 RS-232 console port
Reserved communication port
3 Adaptor connection jack
Jack for DC 12V to connect to the power supply adaptor (not supported by PLNWKB100)
4 Power port
AC24V port for power connection (not supported by PLNWKB000)
5 Buttons and LCD
Buttons and LCD to set network environment and to display other information
6 Basic external input/output signal connectors
Connection ports to connect to external input/output signals (DI:2, DO:2)
7 RS-485 communication port
RS-485 communication ports to connect to air conditioner and ventilation equipment (4EA)
8 RS-485, LON communication ports and BMS connection button(SERVICE SWITCH)
RS-485 communication ports(2EA) and LON comunication port(1EA)
BMS connection button(SERVICE SWITCH)
9 Mini USB port
USB to Serial port for software debugging
10 USB port
For software update and data backup
11 Power switch
Switch to turn on or off the power of the ACP Lonworks
12 Ethernet port
Ethernet port to connect to internet and AC Manager
13 SD card slot
For RS-485 communication data backup.
CAUTION
If four times the power connector for the connection, as shown by using the right connec-
tion, but please note that an electric shock.
Use the designated parts must be connected to a power source.
※Connector manufacturers: PHOENIX CONTACT
PartNo: MVSTBR 2,5 / 2-ST-5, 08 2P 5.00MM
!

ACP LONWORKS FUNCTIONS AND SPECIFICATION
ENGLISH
11
ACP Lonworks Hardware Specification
ACP Lonworks hardware specification is as follows.
Category Description
Boundary of usage temperature 0°C~40°C
CPU i.MX515 – 32Bit 800MHz speed
(Option:MPC5668G, 116MHz)
RAM 128MB DDR2 SDRAM * 2EA
ROM 4GB i-NAND Flash
Communication ports
- Ethernet 10 / 100 BASE-T
- USB : USB Host (SW upgrade, data backup)
mini USB Device (Debug)
- RS-485 communication ports 6EA
- Lon communication port 1EA
- SD card slot (RS-485 communication logging)
- RS-232 Console Port (HMI)
External input/output ports - DI, DO
LED 27EA (RS communication status, Ethernet communication
status, power status, operation status)
LCD 20 ×4 Character-LCD (network environment setting and infor-
mation display)
NOTE
!
License policy
This product follows GPL (General Public License) for the use of Embedded Linux.

12 Operating ACP Lonworks with ACCS
ENGLISH
Operating ACP Lonworks with ACCS
LG ACCS is a UI program of web server that can operate ACP Lonworks.
This chapter explains about the function and process to operate ACP Lonworks using LG ACCS.
Review the initial ACCS screen
LG ACCS (Advanced Centralized Control System) is a program that is automatically run when you
access to ACP Lonworks web server. The user can control the ACP Lonworks and the equip-
ments using LG ACCS and monitor various status information.
When you access LG ACCS, the following LG ACCS program is executed.
1
2

Operating ACP Lonworks with ACCS
ENGLISH
13
1Menu selection button
You can select the corresponding menu from the menu selection button to perform the functions
such as control and monitoring, etc.
ACP Lonworks has the following 9 menus.
Category Description
It can perform the functions of operation status change, lock all, lock tem-
perature, etc. of the equipments connected to the ACP Lonworks.
It can start or stop the equipments connected to the ACP Lonworks
according to preset schedule.
It can set the operation ratio of the entire air conditioner to set the peak
operation ratio to prevent the operation ratio of the air conditioner from
exceeding the set value.
It can use AC Manager to use peak control function.
It can monitor the operation status and error status of the equipments con-
nected to the ACP Lonworks.
It can review the error history occurred in the equipments connected to
the ACP Lonworks.
It can review the power usage used by the equipments connected to the
ACP Lonworks.
It can register, change, or delete the information of the equipments con-
nected to the ACP Lonworks.
It can see the cycle information, etc. of the outdoor unit connected to the
ACP Lonworks. (only if maintenance contract is made with a maintenance
company) Or, you can use the additional functions developed in the future.

14 Operating ACP Lonworks with ACCS
ENGLISH
2Peak operation ratio control, network status display window
The running status of peak operation ratio control mode and the air status of the network are dis-
played with the following icons.
Category Icon Description
Peak operation ratio
It is displayed when it is in peak operation ratio control mode.
It is displayed when peak operation ratio control mode is turned
off.
Network connection status
It is displayed when error occurs during network connection.
It is displayed when it is properly connected to the network and
operating.
It is displayed when it is trying to connect to the network.

Operating ACP Lonworks with ACCS
ENGLISH
15
Controlling the Equipments
You can use LG ACCS to control the functions such as equipment grouping and selection, opera-
tion mode, air flow, air direction, lock, temperature adjustment and stop, etc. (Detail control
menu is different for each equipment.)
LG ACCS control functions have the following advantages.
- With the central control type, you can manage all of the installed equipments using the comput-
er screen.
- Operation and monitoring can be easily done.
- It can be integrated and managed through group setting.
Click ‘Control Group Air Conditioner’ menu at the top of LG ACCS to control the air conditioner.
(This manual explains the air conditioner control as an example, and will explain only the unique
features for other products.)
1
2 3

16 Operating ACP Lonworks with ACCS
ENGLISH
1Air conditioner operation status window
In the air conditioner operation status window, operation status, operation mode, temperature of
the space where the indoor unit is currently installed, and desired temperature of individual air
conditioner are displayed.
Group name & Operation status lamp
At the top of the air conditioner operation status window, the name of the selected group and
the status of individual air conditioner are displayed with the lamps.
The operation status of maximum of 16 air conditioners is displayed in one screen.
Lamp indicates the status of the air conditioner with the color of the lamp. The status of the air
conditioner according to each color is as follows.
Lamp color Status Description
(Green) On It indicates that the air conditioner is operating normally.
(Gray) Off It indicates that the air conditioner is stopped.

Operating ACP Lonworks with ACCS
ENGLISH
17
Mode
In Mode, when the air conditioner is currently in operation, the mode operation is displayed with
an icon.
The operation modes displayed on the screen are as follows.
Room Temp & Set Temp
In the Room Temp, the temperature of the space where the air conditioner is currently installed
is displayed.
But, if the error indicator lamp is on, the number of the current temperature indicates the error
code, not the temperature.
The desired set in the air conditioner is displayed in the Set Temp. The Set Temp is not displayed
during wind only or dehumidification operation, or in an error state. For ventilation equipment,
Set Temp or Room Temp is not displayed. But, the Set Temp is displayed when the direct cool-
ing type ventilation is set as the master.
Type Icon Description
Normal
Operation
State
It is displayed when the air conditioner is currently in cooling operation.
It is displayed when the air conditioner is currently in dehumidification
operation.
It is displayed when the air conditioner is currently in wind only operation.
It is displayed when the air conditioner is currently in heating operation.
It is displayed when the air conditioner is currently in peak operation ratio
control state.
It is displayed when the air conditioner is currently in A/I operation.
A/I(Artificial Intelligence) operation is the automatic operation function for
the air conditioner sets the operation mode and air flow by itself according
to the indoor temperature.
Error State
It is displayed when an error occurred currently to the air conditioner.
It is displayed when an error occurred currently due to the network.

18Operating ACP Lonworks with ACCS
ENGLISH
2 Air conditioner group and air conditioner selection window
In the air conditioner group and air conditioner selection window, the list of air conditioner groups
and the air conditioners set in the system is displayed.
Also, you can select an air conditioner group or air conditioner for air conditioner control.
List of air conditioner groups and list of air conditioners
In 'group', the list of air conditioner group set in the ACP Lonworks is displayed. If you select a
particular air conditioner group, the list of the air conditioners that belong to the corresponding air
conditioner group is displayed in ‘air conditioner’ on the right.
If you click the air conditioner group to select from the list, the corresponding group is selected,
and if you click again, the selection of the corresponding group is cancelled. Also, if you click
several groups, you can select several groups at the same time.
In 'air conditioner', the list of the air conditioners that belong to the particular air conditioner
group in the ACP Lonworks is displayed.
To select several air conditioners, drag with the mouse or select an air conditioner while pressing
down ctrl key, or you can select using shift key.

Operating ACP Lonworks with ACCS
ENGLISH
19
3 Control & Monitoring Window
It displays the air conditioner control setting selected from the list of the air conditioner group and
the air conditioner list to control.
Mode
The operation method of the air conditioner can be set at the mode. The modes to set are as fol-
lows:
Icon Description
It operates the cooling operation. The cooling operation can set the desired temper-
ature to 18°C ~ 30°C
Note: Setting the set temp
Because too much cooling is harmful for health, set the suitable desired temperature.
About 5°C is better for the difference between the indoor temperature and the outdoor tem-
perature. If the set temp is higher than the indoor temperature during the cooling operation,
it does not operate the cooling operation, but the wind only operation.
It drives the heating operation. The heating operation can set the desired tempera-
ture to 18°C ~ 30°C
Note: Setting the set temp
The excessive heating is harmful for the health, so set the suitable desired temperature.
About 5°C is better for the difference between the indoor temperature and the outdoor tem-
perature. If the set temp is lower than the indoor temperature during the heating operation,
it does not operate the heating operation, but the ventilation.
The dry eliminates moisture. It can effectively eliminate moisture during the rainy
season or at the high humidity condition. When it is selected, the desired tempera-
ture cannot be set.
It circulates the fresh air. The ventilation only may be used in Spring and Autumn.
When it is selected, the desired temperature cannot be set.
AI operation automatically maintains the indoor temperature at its optimal state
according to the indoor temperature.

20 Operating ACP Lonworks with ACCS
ENGLISH
Fan Speed
It controls the air flow. The types of air flow to set are as follows:
Air flow Description
It sets to ventilate with a small of air flow.
It sets to ventilate at the medium level of air flow.
It sets to ventilate at the high level of air flow.
It sets to automatically ventilate at the suitable level of air flow for the environment
with the indoor unit installed.
It sets to ventilate with the maximum air flow.
(It only appears when ventilation product is selected.)
Auto Swing
It sets the air direction of the current air conditioner to Up & down or Left & right.
Icon Description
It executes the air direction operation of the air conditioner.
It stops the air direction operation of the air conditioner.
Other manuals for V-NET PLNWKB000
1
This manual suits for next models
1
Table of contents
Other LG Gateway manuals

LG
LG BNU-BAC Operating instructions

LG
LG BNU-LW User manual

LG
LG REGX-XOXXA User manual

LG
LG PSNFP14A0 User manual

LG
LG PWFMDB200 User manual

LG
LG PWFMDB200 User manual

LG
LG PDRYCB500 User manual

LG
LG BECON HVAC BACnet PQNFB17C1 User manual

LG
LG BACnet Touch Operating instructions

LG
LG 9GW97185D6 User manual
Popular Gateway manuals by other brands

Riello UPS
Riello UPS MULTICOM 411 quick start

Grandstream Networks
Grandstream Networks BroadWorks BroadSoft GXW-400X user manual

Awilco multiplex
Awilco multiplex IP-EFOY-GATEWAY Technical overview

Xtrend
Xtrend ET5000 user manual

RTA
RTA 460PSWI-NNA1 Product user guide

TIS
TIS TIS-KNX-PORT installation manual