LG Pra.L BLL1 User manual

Please read this manual carefully before operating
your set and retain it for future reference.
www.lg.com
OWNER’S MANUAL
Total Lift Up
Care
MODEL
BLL1
Copyright © 2019 LG ElectronicsInc. All Rights Reserved.
1906_Rev01
MFL71422320

Table of Contents
1 Skin Safety
Information. . . . . . . . . .3
Recommendations for safe use
of the product. . . . . . . . . . . . . . . . . 3
2 Setting up. . . . . . . . . .12
Unique features . . . . . . . . . . . . . .12
Notification. . . . . . . . . . . . . . . . . . .13
Parts . . . . . . . . . . . . . . . . . . . . . . . . .14
Unit description . . . . . . . . . . . . . .15
3 Operation . . . . . . . . . .17
Total Care Mode
. . . . . . . . . . . . . .17
Tightening mode
. . . . . . . . . . . . .23
Lifting mode
. . . . . . . . . . . . . . . . .25
Charging the battery
. . . . . . . . .27
Charging. . . . . . . . . . . . . . . . . . . .27
Checking the charging status
. . . . . . . . . . . . . . . . . . . . . . . . . .29
Checking battery status. . . .30
How to use the unit . . . . . . . . . .31
Changing Care mode. . . . . . .31
Changing Level . . . . . . . . . . . . .33
Voice Assistance Setting . . .34
Language Setting . . . . . . . . . .34
4 Troubleshooting . . . . .35
Troubleshooting . . . . . . . . . . . . . .35
5 Appendix. . . . . . . . . . .37
Specifications . . . . . . . . . . . . . . . .37
Maintenance . . . . . . . . . . . . . . . . .38
Handling the Unit . . . . . . . . . .38
6 Precautions for use . .39
Safety Information . . . . . . . . . . .39

Skin Safety Information 3
1 Skin Safety Information
Recommendations for safe use of the product
yDo not use this device during
the last two months if your
skin is recovering due to skin
related procedures, cosmetic
surgery, or procedures for
hair loss. Please use it after
consultation with a specialist.
yDevice to be used as a facial
treatments only, it is not
recommended for use on
body.
yDo not use the device on
mucous membranes including
oral cavity. Do not place this
device directly on your ear.
yWhen using this unit on the
neck, avoid the part of the
neck where the thyroid is
located.

Skin Safety Information4
yPlease use the device after consultation with a specialist surely.
-Cardiovascular disease
-Endocrine abnormality
-Sensory nervous system
abnormality
-Skin disease
-Ophthalmology and surgery
(LASIK, LASEK, etc.)
-Infectious disease
-A person with epileptic
symptoms
-A person taking hormone
imbalance medication
-If you have other illnesses, name
of a diseases, or abnormalities in
your body
-Undergoing dermatology
related treatment or having skin
problems
-Allergies, acne, skin infections,
skin related procedures, cosmetic
surgery, procedures for hair loss
-In case of skin disease or skin
irritation
-In case of implanted an
electronic devices such as cardiac
pacemakers or wear to metal
prosthetics
yDepending on individual skin condition, the device may cause a
variety of skin irritations.
If such irritation persists, please reduce the number of uses.

Skin Safety Information 5
yDevice use not
recommended
for pregnant,
menstruating or
lactating women.
(Unstable hormonal
balance may cause
temporary skin
issues.)
yDo not allow people
to use who can not
clearly express their
own will, including
infants.
yPeople with
photosensitivity such
as sunlight allergy, do
not use.

Skin Safety Information6
yDo not use this unit
immediately after
shaving.
yDo not use this
unit while driving or
walking.
yDo not use the
head with the head
stopped at one place,
but please use it
according to the guide
of this manual.

Skin Safety Information 7
yPlease follow
recommended hours
of use when long time
use because there is
a possibility of a low-
temperature burn.
yDo not make direct
eye contact with LED
light while device is in
operation. Excessive
exposure to LED
light can cause eye
damage.
yBefore use, please
remove the precious
metal parts that this
unit touches.

Skin Safety Information8
yDo not use the device
for purposes other
than those set out in
this guide.

Skin Safety Information 9
Q&A
“ What kind of cosmetics should I use?”
Q1
Please use water-soluble products such as water gel (cream) or
ultrasonic wave gel for your skin.
Please pay attention to using cosmetics that contain the following
ingredients as it may reduce the effect: denatured alcohol, sunscreen,
retinol, oil

Skin Safety Information10
“ How can I know if this unit is t for my
skin? ”
Q2
Before using it on your face, it is recommended to test the water gel
you are wearing with the unit on inside your arm.

Skin Safety Information 11
“ What should I do if I feel dry? ”
Q3
- Please reduce the frequency of use
in a week.
- It is recommended to use moisturizing
cream or mask pack for moisturizing
immediately after use.
- If you are taking medication, consult
your health care professional before
using this medicine to induce skin
dryness.

Setting up12
Unique features
Complex elasticity management
yTotal Care Mode (Tightening + Lifting mode Complex
management)
- To perform tightening and lifting effect by managing high
frequency, RED LED and micro current step by step
yTightening mode
- The thermal energy of the high frequency current (deep heat
effect) and the wavelength of the RED LED are transmitted to
the skin to help improve elasticity.
yLifting mode
- Micro currents stimulate skin tissue and muscles to lift the face.
Skin contact safety material and Head protection cap
- The head (skin contact area) is used with medical material which is
safe for skin.
- The Head protection cap protects the head part, enabling clean
storage management.
Easy to use
-As voice guidance, guide how to care easily during use.
-This product is a wireless product with USB charging method and
can be used during charging.
2 Setting up

Setting up 13
Notification
Symbols used in this manual
, Note
Indicates special notes and operating features.
> Caution
Indicates cautions for preventing possible damages from abuse.

Setting up14
Parts
Head
protection cap
Charging cradle
Unit Charging adapter USB cable
(C Type)
Pouch Owner’s manual /
Quick start guide

Setting up 15
1(POWER)
Head
Battery status LED
Front
LEVEL LED
LEVEL Button
Unit description
Unit

Setting up16
Bottom
USB port
(For
charging)
USB port
(For
charging)
Charging
pins
Charging
pins
Charging cradle
Speaker

Operation 17
Total Care Mode
The total care mode consists of the tightening mode and the lifting
mode.
Tightening mode helps to improve elasticity in skin dermis. Lifting
mode stimulates skin tissue and muscles to help face lifting.
The total care mode works for a total of 18 minutes, 6 minutes per
session, to care for three areas at once.
Recommended usage period
Recommend product use is twice a week.
Using more than two times continuously on the same area of the face
may cause a burning sensation on skin.
Using product
Recommend using water-soluble products such as water gel (cream)
or ultrasonic wave gel for your skin.
Main functions
Tightening mode operates with high frequency and RED LED.
Lifting mode operates with micro current. Vibration periodically
sounds for purposes of notication during operating Lifting mode.
Sound effect sounds every 5 seconds during operation. Massage
while slowly pulling up until you hear a sound effect.
If you set the voice guidance function to mute, the unit doesn’t
provide voice guidance and sound effect guide.
, Note
3 Operation

Operation18
How to use
Please follow the steps below for care.
1. Please start elasticity management after remove makeup and
wash the face
2. After cleansing, please use this appliance with plenty of water gel
on the area of your face or device head to be used. If you do not
apply enough water gel, you may feel skin irritation such as
stinging.
3. Press the 1(Power) button to turn on the power, then check the
total care mode.
To change to total care mode, press and hold the LEVEL button
for about 5 seconds to cycle through each mode in case of
operating Tightening or Lifting mode.

Operation 19
4. Massage the first care area from bottom to top where you want
care.
Care Areas :
Forehead / Cheeks / Chin / Neck
>When using the device on the neck, do not use on Adam’s apple
where the thyroid gland is located. Thyroid patients must consult
with your doctor before use.
yTightening mode operates for 3 minutes.
Massage while slowly pulling up
according to the direction of the arrow in
the picture until you hear a sound effect.
- The device produces a sound effect
every 5 seconds.
yTightening mode is switched to the lifting mode with voice
guidance after operating tightening mode for 3 minutes. Massage
the same area for 3 minutes in the same way.
yIf you set the voice guidance function to guide off (Mute), no
voice guidance or sound effect is provided.
yVibration periodically sounds for purposes of notication
during operating Lifting mode.
, Note

Operation20
5. Massage the second care area from bottom to top where you
want care.
Care Areas :
Forehead / Cheeks / Chin / Neck
>When using the device on the neck, do not use on Adam’s apple
where the thyroid gland is located. Thyroid patients must consult
with your doctor before use.
yTightening mode operates for 3 minutes.
Massage while slowly pulling up
according to the direction of the arrow in
the picture until you hear a sound effect.
- The device produces a sound effect
every 5 seconds.
yTightening mode is switched to the lifting mode with voice
guidance after operating tightening mode for 3 minutes. Massage
the same area for 3 minutes in the same way.
yIf you set the voice guidance function to guide off (Mute), no
voice guidance or sound effect is provided.
yVibration periodically sounds for purposes of notication
during operating Lifting mode.
, Note
Other manuals for Pra.L BLL1
1
Table of contents
Other LG Personal Care Product manuals
Popular Personal Care Product manuals by other brands

evo Medical Solutions
evo Medical Solutions Aeroneb GO 7010 quick start guide

drybar
drybar The Single Shot 900-2840-4 Operating instructions & safety guide

Carmen
Carmen Brilliance Ion Pro manual

Sleep Shepherd
Sleep Shepherd Blue user manual

mychway
mychway MS-54D1S user manual

Juzo
Juzo 9662 Instructions for use