Life form LF01040U User manual

Hemodialysis Practice Arm
Skin & Vein Replacement Kit
LF01040U
Instruction Manual
Hemodialysis Practice Arm
Skin & Vein Replacement Kit
LF01040U
Instruction Manual
Products by Nasco
Products by Nasco
COPYRIGHT © NASCO 2001 PRINTED IN U.S.A. NP 68-01/RV 1-17
COPYRIGHT © NASCO 2001 PRINTED IN U.S.A. NP 68-01/RV 1-17
Other Available Simulators
Other Available Simulators
LF00698U Adult Injectable Arm (Light)
LF00855U Male Catheterization
LF00856U Female Catheterization
LF00901U Prostate Examination
LF00906U Ostomy Care
LF00929U Surgical Bandaging
LF00957U Enema Administration
LF00958U Pediatric Injectable Arm
LF00961U Intramuscular Injection
LF00984U Breast Examination
LF00995U Arterial Puncture Arm
LF00999U Pediatric Injectable Head
LF01005U First Aid Arm
LF01008U Intradermal Injection Arm
LF01012U Heart Catheterization (TPN)
LF01019U Ear Examination
LF01027U Peritoneal Dialysis
LF01028U Suture Practice Arm
LF01034U Suture Practice Leg
LF01036U Spinal Injection
LF01037U Hemodialysis Practice Arm
LF01038U Episiotomy Suturing Set
LF01042U Suture Kit
LF01062U Pelvic, Normal & Abnormal
LF01063U Stump Bandaging, Upper
LF01064U Stump Bandaging, Lower
LF01069U Cervical Effacement
LF01070U Birthing Station
LF01082U Cricothyrotomy
LF01083U Tracheostomy Care
LF01084U Sigmoidoscopic
Examination
LF01087U
Central Venous Cannulation
LF01095U Blood Pressure Arm
LF01108U Infant Intraosseous Infusion
LF01121U Advanced IV Arm
LF01131U Venipuncture and Injection Arm
LF01139U Advanced IV Hand
LF01142U Auscultation Trainer
LF01143U Testicular Exam
LF01152U Male & Female Catheter
LF01155U Advanced CPR Dog
LF01162U Venatech IV Trainer
LF01174U NG Tube & Trach Skills
LF01184U Venatech IM & Sub Q
LF01193U Special Needs Baby
LF03000U CPARLENE®Series
LF03601U Adult Airway Management
Trainer with Stand
LF03602U Adult Airway Management
Manikin
LF03609U Child Airway Management
Trainer with Stand
LF03616U Child CRiSis™Manikin
LF03617U Deluxe Child CRiSis™
Manikin with Arrhythmia Tutor
LF03620U PALS Update Kit
LF03623U Infant Airway Management
Trainer with Stand
LF03632U Child Intraosseous Infusion/
Femoral Access Leg on a Stand
LF03633U Child Airway Management
Trainer Torso
LF03693U Basic Buddy®CPR Manikin
LF03699U “Airway Larry” Airway
Management Trainer
LF03709U Infant CRiSis™Manikin
LF03720U Baby Buddy™Infant CPR Manikin
LF03750U Bariatric CPR Manikin
LF03770U Chest Tube
LF03953U CRiSis™Manikin, Complete
LF03955U Deluxe CRiSis™Manikin
LF03956U Deluxe “Plus” CRiSis™Manikin
LF03965U Adult CRiSis™Auscultation
Manikin
LF03966U Adult CRiSis™Auscultation
Manikin with ECG Simulator
LF04000U GERi™/KERi™Manikin Series
LF04200U Adult Sternal Intraosseous
Infusion
LF06001U CPR Prompt®Adult/Child
Manikin
LF06012U CPR Prompt®Infant Manikin
LF06200U CPR Prompt®Keychain
Rescue Aid
LF06204U CPR Prompt®Rescue and
Practice Aid
LF00698U Adult Injectable Arm (Light)
LF00855U Male Catheterization
LF00856U Female Catheterization
LF00901U Prostate Examination
LF00906U Ostomy Care
LF00929U Surgical Bandaging
LF00957U Enema Administration
LF00958U Pediatric Injectable Arm
LF00961U Intramuscular Injection
LF00984U Breast Examination
LF00995U Arterial Puncture Arm
LF00999U Pediatric Injectable Head
LF01005U First Aid Arm
LF01008U Intradermal Injection Arm
LF01012U Heart Catheterization (TPN)
LF01019U Ear Examination
LF01027U Peritoneal Dialysis
LF01028U Suture Practice Arm
LF01034U Suture Practice Leg
LF01036U Spinal Injection
LF01037U Hemodialysis Practice Arm
LF01038U Episiotomy Suturing Set
LF01042U Suture Kit
LF01062U Pelvic, Normal & Abnormal
LF01063U Stump Bandaging, Upper
LF01064U Stump Bandaging, Lower
LF01069U Cervical Effacement
LF01070U Birthing Station
LF01082U Cricothyrotomy
LF01083U Tracheostomy Care
LF01084U Sigmoidoscopic
Examination
LF01087U
Central Venous Cannulation
LF01095U Blood Pressure Arm
LF01108U Infant Intraosseous Infusion
LF01121U Advanced IV Arm
LF01131U Venipuncture and Injection Arm
LF01139U Advanced IV Hand
LF01142U Auscultation Trainer
LF01143U Testicular Exam
LF01152U Male & Female Catheter
LF01155U Advanced CPR Dog
LF01162U Venatech IV Trainer
LF01174U NG Tube & Trach Skills
LF01184U Venatech IM & Sub Q
LF01193U Special Needs Baby
LF03000U CPARLENE®Series
LF03601U Adult Airway Management
Trainer with Stand
LF03602U Adult Airway Management
Manikin
LF03609U Child Airway Management
Trainer with Stand
LF03616U Child CRiSis™Manikin
LF03617U Deluxe Child CRiSis™
Manikin with Arrhythmia Tutor
LF03620U PALS Update Kit
LF03623U Infant Airway Management
Trainer with Stand
LF03632U Child Intraosseous Infusion/
Femoral Access Leg on a Stand
LF03633U Child Airway Management
Trainer Torso
LF03693U Basic Buddy®CPR Manikin
LF03699U “Airway Larry” Airway
Management Trainer
LF03709U Infant CRiSis™Manikin
LF03720U Baby Buddy™Infant CPR Manikin
LF03750U Bariatric CPR Manikin
LF03770U Chest Tube
LF03953U CRiSis™Manikin, Complete
LF03955U Deluxe CRiSis™Manikin
LF03956U Deluxe “Plus” CRiSis™Manikin
LF03965U Adult CRiSis™Auscultation
Manikin
LF03966U Adult CRiSis™Auscultation
Manikin with ECG Simulator
LF04000U GERi™/KERi™Manikin Series
LF04200U Adult Sternal Intraosseous
Infusion
LF06001U CPR Prompt®Adult/Child
Manikin
LF06012U CPR Prompt®Infant Manikin
LF06200U CPR Prompt®Keychain
Rescue Aid
LF06204U CPR Prompt®Rescue and
Practice Aid
901 Janesville Avenue, P.O. Box 901
Fort Atkinson, Wisconsin 53538-0901
1.800.558.9595
eNasco.com • E-mail: [email protected]
901 Janesville Avenue, P.O. Box 901
Fort Atkinson, Wisconsin 53538-0901
1.800.558.9595
eNasco.com • E-mail: [email protected]
NP068_01_LF01040.indd 1 1/19/17 8:14 AM
B. As the skin is worked down over
the core, the tubing may slip from
the channel slightly. The tubing
can usually be slipped back into
position after the skin is slid
completely onto the core.
5. Work Fingers into Place
Guide the fingers and thumb carefully
into the proper holes as the skin is
slipped further down on the core. (See
figure 7.) If you encounter resistance,
simply slide the skin back an inch or
two from the fingers and begin again.
6. Draw Skin Tightly over Core
A. After the fingers are positioned
in the hand, slide the skin over
the remainder of the core to
provide a snug fit. (See figure 8.)
B. If air is trapped in the fingers, a
22-gauge needle can be used to
puncture the fingertip and allow
the air to escape.
7. Check Tubing Location
Feel along the tubing channels to be
certain that the tubing is properly
seated. If it has slipped out of its
channel, it can usually be moved
back into position by working it with
your fingers on the outside of the skin.
B. As the skin is worked down over
the core, the tubing may slip from
the channel slightly. The tubing
can usually be slipped back into
position after the skin is slid
completely onto the core.
5. Work Fingers into Place
Guide the fingers and thumb carefully
into the proper holes as the skin is
slipped further down on the core. (See
figure 7.) If you encounter resistance,
simply slide the skin back an inch or
two from the fingers and begin again.
6. Draw Skin Tightly over Core
A. After the fingers are positioned
in the hand, slide the skin over
the remainder of the core to
provide a snug fit. (See figure 8.)
B. If air is trapped in the fingers, a
22-gauge needle can be used to
puncture the fingertip and allow
the air to escape.
7. Check Tubing Location
Feel along the tubing channels to be
certain that the tubing is properly
seated. If it has slipped out of its
channel, it can usually be moved
back into position by working it with
your fingers on the outside of the skin.
List of Components
• Replacement Skin
• Lace Tie
• Life/form® Lubricant
• Vein Tubing
1. Remove Old Skin and Veins
A. To remove the old skin from the
arm, open the tie at the top end
of the arm. Then, coat the exterior
skin lightly with the lubricant and
strip off the skin so that it will be
inside out when you finish. (See
figures 1 and 2.)
B. Remove the old vein tubing by
pulling the tubing out of the
channel in the arm core.
2. Place New Tubing in Channel
Double the tubing to find the
approximate center and place in
the groove of the core, starting with
the center of the tubing at the center
of the front of the wrist. (See figure 3.)
3. Lubricate Skin
A. Pour the remaining lubricant into
the skin, allowing lubricant to run
down the sides. (See figure 4.)
List of Components
• Replacement Skin
• Lace Tie
• Life/form® Lubricant
• Vein Tubing
1. Remove Old Skin and Veins
A. To remove the old skin from the
arm, open the tie at the top end
of the arm. Then, coat the exterior
skin lightly with the lubricant and
strip off the skin so that it will be
inside out when you finish. (See
figures 1 and 2.)
B. Remove the old vein tubing by
pulling the tubing out of the
channel in the arm core.
2. Place New Tubing in Channel
Double the tubing to find the
approximate center and place in
the groove of the core, starting with
the center of the tubing at the center
of the front of the wrist. (See figure 3.)
3. Lubricate Skin
A. Pour the remaining lubricant into
the skin, allowing lubricant to run
down the sides. (See figure 4.)
Figure 1
Figure 1
Figure 2
Figure 2
Figure 3
Figure 3
Figure 4
Figure 4
Figure 5
Figure 5
Figure 6
Figure 6
Figure 7
Figure 7
Figure 8
Figure 8
Figure 9
Figure 9
Figure 10
Figure 10
B. Squeeze the skin between extend-
ed hands. Work hands back and
forth, up and down the skin to
coat the inside of the skin thor-
oughly. (See figure 5.)
4. Slide Skin On
A. Grasping the skin with both hands,
slide the skin down over the core
until the fingers are approaching
the finger hole. (See figure 6.)
Caution: Work the skin on gently.
Pulling hard on the end of the
skin will stretch the material.
B. Squeeze the skin between extend-
ed hands. Work hands back and
forth, up and down the skin to
coat the inside of the skin thor-
oughly. (See figure 5.)
4. Slide Skin On
A. Grasping the skin with both hands,
slide the skin down over the core
until the fingers are approaching
the finger hole. (See figure 6.)
Caution: Work the skin on gently.
Pulling hard on the end of the
skin will stretch the material.
8. Position Ends of Tubing
Ends of the tubing should emerge
from the center of the end of the
core once the skin is tied. (See
figure 9.)
9. Install Lace Tie and Rinse
A. Thread the lace tie through the
eyelets. (See figure 10.)
B. Pull the skin snugly over the core
and tie the lace to hold the skin in
position. Check at this point to
make sure that the tubing has not
become kinked. Warm water
should be used to rinse any
excess lubricant remaining on the
surface of the skin prior to use.
C. If the skin stretches slightly during
use, it can be tightened by retying
the lace.
8. Position Ends of Tubing
Ends of the tubing should emerge
from the center of the end of the
core once the skin is tied. (See
figure 9.)
9. Install Lace Tie and Rinse
A. Thread the lace tie through the
eyelets. (See figure 10.)
B. Pull the skin snugly over the core
and tie the lace to hold the skin in
position. Check at this point to
make sure that the tubing has not
become kinked. Warm water
should be used to rinse any
excess lubricant remaining on the
surface of the skin prior to use.
C. If the skin stretches slightly during
use, it can be tightened by retying
the lace.
NP068_01_LF01040.indd 2 1/19/17 8:14 AM
B. As the skin is worked down over
the core, the tubing may slip from
the channel slightly. The tubing
can usually be slipped back into
position after the skin is slid
completely onto the core.
5. Work Fingers into Place
Guide the fingers and thumb carefully
into the proper holes as the skin is
slipped further down on the core. (See
figure 7.) If you encounter resistance,
simply slide the skin back an inch or
two from the fingers and begin again.
6. Draw Skin Tightly over Core
A. After the fingers are positioned
in the hand, slide the skin over
the remainder of the core to
provide a snug fit. (See figure 8.)
B. If air is trapped in the fingers, a
22-gauge needle can be used to
puncture the fingertip and allow
the air to escape.
7. Check Tubing Location
Feel along the tubing channels to be
certain that the tubing is properly
seated. If it has slipped out of its
channel, it can usually be moved
back into position by working it with
your fingers on the outside of the skin.
B. As the skin is worked down over
the core, the tubing may slip from
the channel slightly. The tubing
can usually be slipped back into
position after the skin is slid
completely onto the core.
5. Work Fingers into Place
Guide the fingers and thumb carefully
into the proper holes as the skin is
slipped further down on the core. (See
figure 7.) If you encounter resistance,
simply slide the skin back an inch or
two from the fingers and begin again.
6. Draw Skin Tightly over Core
A. After the fingers are positioned
in the hand, slide the skin over
the remainder of the core to
provide a snug fit. (See figure 8.)
B. If air is trapped in the fingers, a
22-gauge needle can be used to
puncture the fingertip and allow
the air to escape.
7. Check Tubing Location
Feel along the tubing channels to be
certain that the tubing is properly
seated. If it has slipped out of its
channel, it can usually be moved
back into position by working it with
your fingers on the outside of the skin.
List of Components
• Replacement Skin
• Lace Tie
• Life/form® Lubricant
• Vein Tubing
1. Remove Old Skin and Veins
A. To remove the old skin from the
arm, open the tie at the top end
of the arm. Then, coat the exterior
skin lightly with the lubricant and
strip off the skin so that it will be
inside out when you finish. (See
figures 1 and 2.)
B. Remove the old vein tubing by
pulling the tubing out of the
channel in the arm core.
2. Place New Tubing in Channel
Double the tubing to find the
approximate center and place in
the groove of the core, starting with
the center of the tubing at the center
of the front of the wrist. (See figure 3.)
3. Lubricate Skin
A. Pour the remaining lubricant into
the skin, allowing lubricant to run
down the sides. (See figure 4.)
List of Components
• Replacement Skin
• Lace Tie
• Life/form® Lubricant
• Vein Tubing
1. Remove Old Skin and Veins
A. To remove the old skin from the
arm, open the tie at the top end
of the arm. Then, coat the exterior
skin lightly with the lubricant and
strip off the skin so that it will be
inside out when you finish. (See
figures 1 and 2.)
B. Remove the old vein tubing by
pulling the tubing out of the
channel in the arm core.
2. Place New Tubing in Channel
Double the tubing to find the
approximate center and place in
the groove of the core, starting with
the center of the tubing at the center
of the front of the wrist. (See figure 3.)
3. Lubricate Skin
A. Pour the remaining lubricant into
the skin, allowing lubricant to run
down the sides. (See figure 4.)
Figure 1
Figure 1
Figure 2
Figure 2
Figure 3
Figure 3
Figure 4
Figure 4
Figure 5
Figure 5
Figure 6
Figure 6
Figure 7
Figure 7
Figure 8
Figure 8
Figure 9
Figure 9
Figure 10
Figure 10
B. Squeeze the skin between extend-
ed hands. Work hands back and
forth, up and down the skin to
coat the inside of the skin thor-
oughly. (See figure 5.)
4. Slide Skin On
A. Grasping the skin with both hands,
slide the skin down over the core
until the fingers are approaching
the finger hole. (See figure 6.)
Caution: Work the skin on gently.
Pulling hard on the end of the
skin will stretch the material.
B. Squeeze the skin between extend-
ed hands. Work hands back and
forth, up and down the skin to
coat the inside of the skin thor-
oughly. (See figure 5.)
4. Slide Skin On
A. Grasping the skin with both hands,
slide the skin down over the core
until the fingers are approaching
the finger hole. (See figure 6.)
Caution: Work the skin on gently.
Pulling hard on the end of the
skin will stretch the material.
8. Position Ends of Tubing
Ends of the tubing should emerge
from the center of the end of the
core once the skin is tied. (See
figure 9.)
9. Install Lace Tie and Rinse
A. Thread the lace tie through the
eyelets. (See figure 10.)
B. Pull the skin snugly over the core
and tie the lace to hold the skin in
position. Check at this point to
make sure that the tubing has not
become kinked. Warm water
should be used to rinse any
excess lubricant remaining on the
surface of the skin prior to use.
C. If the skin stretches slightly during
use, it can be tightened by retying
the lace.
8. Position Ends of Tubing
Ends of the tubing should emerge
from the center of the end of the
core once the skin is tied. (See
figure 9.)
9. Install Lace Tie and Rinse
A. Thread the lace tie through the
eyelets. (See figure 10.)
B. Pull the skin snugly over the core
and tie the lace to hold the skin in
position. Check at this point to
make sure that the tubing has not
become kinked. Warm water
should be used to rinse any
excess lubricant remaining on the
surface of the skin prior to use.
C. If the skin stretches slightly during
use, it can be tightened by retying
the lace.
NP068_01_LF01040.indd 2 1/19/17 8:14 AM
Hemodialysis Practice Arm
Skin & Vein Replacement Kit
LF01040U
Instruction Manual
Hemodialysis Practice Arm
Skin & Vein Replacement Kit
LF01040U
Instruction Manual
Products by Nasco
Products by Nasco
COPYRIGHT © NASCO 2001 PRINTED IN U.S.A. NP 68-01/RV 1-17
COPYRIGHT © NASCO 2001 PRINTED IN U.S.A. NP 68-01/RV 1-17
Other Available Simulators
Other Available Simulators
LF00698U Adult Injectable Arm (Light)
LF00855U Male Catheterization
LF00856U Female Catheterization
LF00901U Prostate Examination
LF00906U Ostomy Care
LF00929U Surgical Bandaging
LF00957U Enema Administration
LF00958U Pediatric Injectable Arm
LF00961U Intramuscular Injection
LF00984U Breast Examination
LF00995U Arterial Puncture Arm
LF00999U Pediatric Injectable Head
LF01005U First Aid Arm
LF01008U Intradermal Injection Arm
LF01012U Heart Catheterization (TPN)
LF01019U Ear Examination
LF01027U Peritoneal Dialysis
LF01028U Suture Practice Arm
LF01034U Suture Practice Leg
LF01036U Spinal Injection
LF01037U Hemodialysis Practice Arm
LF01038U Episiotomy Suturing Set
LF01042U Suture Kit
LF01062U Pelvic, Normal & Abnormal
LF01063U Stump Bandaging, Upper
LF01064U Stump Bandaging, Lower
LF01069U Cervical Effacement
LF01070U Birthing Station
LF01082U Cricothyrotomy
LF01083U Tracheostomy Care
LF01084U Sigmoidoscopic
Examination
LF01087U
Central Venous Cannulation
LF01095U Blood Pressure Arm
LF01108U Infant Intraosseous Infusion
LF01121U Advanced IV Arm
LF01131U Venipuncture and Injection Arm
LF01139U Advanced IV Hand
LF01142U Auscultation Trainer
LF01143U Testicular Exam
LF01152U Male & Female Catheter
LF01155U Advanced CPR Dog
LF01162U Venatech IV Trainer
LF01174U NG Tube & Trach Skills
LF01184U Venatech IM & Sub Q
LF01193U Special Needs Baby
LF03000U CPARLENE®Series
LF03601U Adult Airway Management
Trainer with Stand
LF03602U Adult Airway Management
Manikin
LF03609U Child Airway Management
Trainer with Stand
LF03616U Child CRiSis™Manikin
LF03617U Deluxe Child CRiSis™
Manikin with Arrhythmia Tutor
LF03620U PALS Update Kit
LF03623U Infant Airway Management
Trainer with Stand
LF03632U Child Intraosseous Infusion/
Femoral Access Leg on a Stand
LF03633U Child Airway Management
Trainer Torso
LF03693U Basic Buddy®CPR Manikin
LF03699U “Airway Larry” Airway
Management Trainer
LF03709U Infant CRiSis™Manikin
LF03720U Baby Buddy™Infant CPR Manikin
LF03750U Bariatric CPR Manikin
LF03770U Chest Tube
LF03953U CRiSis™Manikin, Complete
LF03955U Deluxe CRiSis™Manikin
LF03956U Deluxe “Plus” CRiSis™Manikin
LF03965U Adult CRiSis™Auscultation
Manikin
LF03966U Adult CRiSis™Auscultation
Manikin with ECG Simulator
LF04000U GERi™/KERi™Manikin Series
LF04200U Adult Sternal Intraosseous
Infusion
LF06001U CPR Prompt®Adult/Child
Manikin
LF06012U CPR Prompt®Infant Manikin
LF06200U CPR Prompt®Keychain
Rescue Aid
LF06204U CPR Prompt®Rescue and
Practice Aid
LF00698U Adult Injectable Arm (Light)
LF00855U Male Catheterization
LF00856U Female Catheterization
LF00901U Prostate Examination
LF00906U Ostomy Care
LF00929U Surgical Bandaging
LF00957U Enema Administration
LF00958U Pediatric Injectable Arm
LF00961U Intramuscular Injection
LF00984U Breast Examination
LF00995U Arterial Puncture Arm
LF00999U Pediatric Injectable Head
LF01005U First Aid Arm
LF01008U Intradermal Injection Arm
LF01012U Heart Catheterization (TPN)
LF01019U Ear Examination
LF01027U Peritoneal Dialysis
LF01028U Suture Practice Arm
LF01034U Suture Practice Leg
LF01036U Spinal Injection
LF01037U Hemodialysis Practice Arm
LF01038U Episiotomy Suturing Set
LF01042U Suture Kit
LF01062U Pelvic, Normal & Abnormal
LF01063U Stump Bandaging, Upper
LF01064U Stump Bandaging, Lower
LF01069U Cervical Effacement
LF01070U Birthing Station
LF01082U Cricothyrotomy
LF01083U Tracheostomy Care
LF01084U Sigmoidoscopic
Examination
LF01087U
Central Venous Cannulation
LF01095U Blood Pressure Arm
LF01108U Infant Intraosseous Infusion
LF01121U Advanced IV Arm
LF01131U Venipuncture and Injection Arm
LF01139U Advanced IV Hand
LF01142U Auscultation Trainer
LF01143U Testicular Exam
LF01152U Male & Female Catheter
LF01155U Advanced CPR Dog
LF01162U Venatech IV Trainer
LF01174U NG Tube & Trach Skills
LF01184U Venatech IM & Sub Q
LF01193U Special Needs Baby
LF03000U CPARLENE®Series
LF03601U Adult Airway Management
Trainer with Stand
LF03602U Adult Airway Management
Manikin
LF03609U Child Airway Management
Trainer with Stand
LF03616U Child CRiSis™Manikin
LF03617U Deluxe Child CRiSis™
Manikin with Arrhythmia Tutor
LF03620U PALS Update Kit
LF03623U Infant Airway Management
Trainer with Stand
LF03632U Child Intraosseous Infusion/
Femoral Access Leg on a Stand
LF03633U Child Airway Management
Trainer Torso
LF03693U Basic Buddy®CPR Manikin
LF03699U “Airway Larry” Airway
Management Trainer
LF03709U Infant CRiSis™Manikin
LF03720U Baby Buddy™Infant CPR Manikin
LF03750U Bariatric CPR Manikin
LF03770U Chest Tube
LF03953U CRiSis™Manikin, Complete
LF03955U Deluxe CRiSis™Manikin
LF03956U Deluxe “Plus” CRiSis™Manikin
LF03965U Adult CRiSis™Auscultation
Manikin
LF03966U Adult CRiSis™Auscultation
Manikin with ECG Simulator
LF04000U GERi™/KERi™Manikin Series
LF04200U Adult Sternal Intraosseous
Infusion
LF06001U CPR Prompt®Adult/Child
Manikin
LF06012U CPR Prompt®Infant Manikin
LF06200U CPR Prompt®Keychain
Rescue Aid
LF06204U CPR Prompt®Rescue and
Practice Aid
901 Janesville Avenue, P.O. Box 901
Fort Atkinson, Wisconsin 53538-0901
1.800.558.9595
eNasco.com • E-mail: [email protected]
901 Janesville Avenue, P.O. Box 901
Fort Atkinson, Wisconsin 53538-0901
1.800.558.9595
eNasco.com • E-mail: [email protected]
NP068_01_LF01040.indd 1 1/19/17 8:14 AM

Other Life form Science Education Product manuals

Life form LF03699U User manual

Life form

Life form LF03699U User manual

Life form LF01027U User manual

Life form

Life form LF01027U User manual

Life form LF01027U User manual

Life form

Life form LF01027U User manual

Life form Venatech IV LF01162U User manual

Life form

Life form Venatech IV LF01162U User manual

Life form LF03611U User manual

Life form

Life form LF03611U User manual

Popular Science Education Product manuals by other brands

Levenhuk LabZZ Tellurion user manual

Levenhuk

Levenhuk LabZZ Tellurion user manual

BT BT-CSIS user guide

BT

BT BT-CSIS user guide

3B SCIENTIFIC PHYSICS U11394 instruction manual

3B SCIENTIFIC PHYSICS

3B SCIENTIFIC PHYSICS U11394 instruction manual

Oregon Scientific SmartGlobe Starry SG101R user manual

Oregon Scientific

Oregon Scientific SmartGlobe Starry SG101R user manual

3D Molecular Designs ENZYMES IN ACTION KIT 1-Group Set manual

3D Molecular Designs

3D Molecular Designs ENZYMES IN ACTION KIT 1-Group Set manual

Elecrow Crowtail Starter Kit user guide

Elecrow

Elecrow Crowtail Starter Kit user guide

KOKEN LM-109M instruction manual

KOKEN

KOKEN LM-109M instruction manual

WATSON INDUSTRIES VSG-E469 owner's manual

WATSON INDUSTRIES

WATSON INDUSTRIES VSG-E469 owner's manual

Utopia 360 4D+ Dinosaur Experience user manual

Utopia 360

Utopia 360 4D+ Dinosaur Experience user manual

3B SCIENTIFIC PHYSICS 1017735 instruction manual

3B SCIENTIFIC PHYSICS

3B SCIENTIFIC PHYSICS 1017735 instruction manual

Ambu Man manual

Ambu

Ambu Man manual

KOKEN LM-094B instruction manual

KOKEN

KOKEN LM-094B instruction manual

Alga Science MOTIONSENSOR manual

Alga Science

Alga Science MOTIONSENSOR manual

DF ROBOT Light Chaser manual

DF ROBOT

DF ROBOT Light Chaser manual

Reality Works Horse Hoof Model quick start guide

Reality Works

Reality Works Horse Hoof Model quick start guide

InVento Star Coaster instruction manual

InVento

InVento Star Coaster instruction manual

Reality Works Small Dog Model quick start guide

Reality Works

Reality Works Small Dog Model quick start guide

Green Power IET FORMULA GOBLIN G2 manual

Green Power

Green Power IET FORMULA GOBLIN G2 manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.