LIGHTINC MH-200 HYBRID PRO MKII User manual

1
MANUAL
MH-200 HYBRID PRO MKII
HIGHLY
EFFICIENT LED
DOUBLE
PRISM
IRIS &
FROST

1
THANK YOU FOR PURCHASING OUR PRODUCTS.
Every unit has been thoroughly tested and has been shipped in perfect operating condition. Carefully check the
outer and inner packaging for damage that may have occurred during shipping. If the carton appears to be
damaged, carefully inspect your fixture for any damage and be sure all accessories necessary to operate the
unit have arrived intact. In case damage has been found or parts are missing, please contact the distributor or
your dealer for further instructions. Do not return this unit to your dealer without first contacting them.
1. SAFETY INFORMATION
Before operating this unit, please carefully read this manual and keep for
usage in the future. It is necessary to respect the following rules.
Disposal of the device after its life cycle can damage the environment. Take
it to a recycling company or return it to the authorized dealer.
The products referred to in this manual conform to the guidelines of the
European Community and are therefore marked with the CE logo.
Keep this device away from children and unauthorized users. The dealer is
not liable for damage as a result of ignoring the information in this manual
and incorrect operation.
Before operating this unit, please make sure the housing is in good condition
and ensure pan and tilt can rotate in full range.
0.5M
Ensure that a minimum distance of 0.5 m is maintained between the fixture
and any flammable material.
The device can only function with 100-240v voltage, 50 / 60Hz power. Do not
connect to any other power supply. Disconnect the device from the power
supply before opening it or before maintenance.
Never look directly into the projecting lens when the fixture is switched on.
The light can cause epileptic seizures in light-sensitive people or people with
epilepsy. Extreme caution and compliance with these safety instructions are
required, especially with beam effects.
Do not place or install the device on a surface that is exposed to vibration or
any movement.
-15⁰C + 45⁰C
The device should operate in temperature range -15 °C and + 45 °C. Do not
use the device if the temperature exceeds this range.
The lens shield must be replaced if it is broken. Never use the device if the
shield is not fully closed.
Safety I class device must be earthed.
When the fixture is mounted overhead, the safety rope must be attached to
the correct mounting location on the bottom of the device.
Please note that damage caused by manual changes to the device is not
covered by the warranty.
♲
If possible, recycle all packaging material

2
2. SETTING UP:
Power Supply: Before plugging in your unit, be sure the voltage in your area matches the required voltage for
your fixture. The unit has auto power supply and is workable in 90-250V/50~60Hz.
Connection to the mains: For protection from electric shock, the fixture must be earthed.
Install a suitable plug on the power cord, note that the cores in the power cord are colored according to the
following table. The earth has to be connected!
If you have any doubts about proper installation, consult a qualified electrician.
Core (EU)
Core (US)
Connection
Plug Terminal Marking
Brown
Light blue
Yellow/Green
Black
White
Green
Live
Neutral
Earth
L
N
DMX512 connection:
The fixture is equipped with 3-pin and 5-pin XLR sockets for DMX input and output. The sockets are wired in
parallel.
Only use a shielded twisted-pair cable designed for RS-485 and 3-pin or 5-pin XLR-plugs and connectors in
order to connect the controller with the fixture or one fixture with another.
DMX-output
XLR mounting-sockets (rear view):
DMX-input
XLR mounting-plugs (rear view):
DMX Linking: To ensure proper DMX data transmission when using several DMX fixtures, try to use the
shortest cable path possible. The order in which fixtures are connected in a DMX line does not influence the
DMX addressing. For example; a fixture assigned a DMX address of 1 may be placed anywhere in a DMX line.
When a fixture is assigned a DMX address of 1, the DMX controller knows to send DATA assigned to address 1
to that unit, no matter where it is located in the DMX chain.
Operating Modes: You can use the fixture in 3 ways:
•Auto Mode - The unit will automatically chase through the different colors and built-in programs.
•Slave Mode –The unit will run under slave mode.
•DMX control mode - This function will allow you to control each individual fixture’s traits with a standard DMX
512 controller.
DMX Mode: Operating through a DMX controller gives the user the freedom to create their own programs
tailored to their own individual needs. This function also allows you to use your fixtures as spotlights.
•This function will allow you to control each individual fixture’s traits with a standard DMX 512 controller.
•The fixture uses 16/19 two DMX channels modes to operate. Please see “DMX Values and Functions” for
the DMX traits.
•To run your fixture in DMX mode, plug in the fixture via the XLR connections to any standard DMX controller.
Set your desired DMX address following the setup specifications that comes with your DMX controller.
Touch Buttons:
There are four touch buttons under the LCD display:
Menu, Up, Down, Enter.
Normally, the LED will display the current DMX address
code of the fixture. At this time, press up and down to
choose the function you want.
LED Operation Menu: LED screen with four touch buttons: MENU, UP, DOWN and ENTER.

3
LCD display operation:
Address 001-512
Display
Show Reve Revl
Natu
Language Chinese
English
Backlight
01MIN
05MIN
08MIN
Ligh
MenuBack
01MIN
05MIN
08MIN
BackFlah Off
Open
Return
Feature
XY Setup
X Reverse Open
Off
Y Reverse Open
Off
XY Speed Norm
X Angle 540
XY Fback Open
Off
Return
Shortout Open
Off
ChanMode Stan
Smal
ReceMode Auto
DMX
RunMode
Auto
Slve
Off
Sigclear Open
Off
DMX Reset Open
Off
Return

4
Infosee
WorkHour 0001
Times 0001
LampTemp 00
Version HM02
Sparetim Most
Sparecut Most
Return
Control
Channel 000-255
Channel 01
Channel 02
Channel 03
Return
AssiTool
Factory
Defaults
Redress
Pan 000-255
Tilt 000-255
Fixed-Gobo 000-255
Rot-Gobo 000-255
Color 000-255
Focus 000-255
Zoom 000-255
Dimmer 000-255
Prism 1 000-255
Prism 2 000-255
Frost 000-255
Iris 000-255
Return
Built-in
Checksum Verify01-10
000-255
Return
ChanLeve
Channel 000-225
Channel 01
Channel 02
Channel 03
Return
Reset Annu
Exec
Exit Menu

5
3. DMX CHART:
Standard
Mode
Reduced Mode
DMX Value
Function
1
1
0~255
Pan 0~540
2
*
0~255
Pan Fine 16bit
3
2
0~255
Tilt 0~230
4
*
0~255
Tilt Fine 16bit
5
*
0~255
Pan/Tilt Speed Fast-Slow
6
3
0~255
Dimmer
7
4
Strobe
0-2
Open
3~103
Strobe slow-fast
104~107
Open
108~207
Pulse Strobe 1 Slow to Fast
208~212
Open
213~238
Pulse Strobe 2 Slow to Fast
239~251
Random Strobe 2 Slow to Fast
252~255
Open
8
5
Color Wheel
0~128
Index
129~131
Red
132~135
Yellow
136~138
Blue
139~142
Magenta
143~146
Cyan
147~150
Pink
151~154
Green
155~158
Orange
159~207
Forward Fast-Slow
208~255
Backward Slow-Fast
9
6
Static Gobo Wheel
0~7
Open
8~15
Gobo 1
16~23
Gobo 2
24~31
Gobo 3
32~39
Gobo 4
40~47
Gobo 5
48~55
Gobo 6
56~63
Gobo 7
64~70
Gobo 7 shake Fast - slow
71~77
Gobo 6 shake Fast - slow
78~84
Gobo 5 shake Fast - slow
85~91
Gobo 4 shake Fast - slow
92~99
Gobo 3 shake Fast - slow
100~107
Gobo 2 shake Fast - slow
108~114
Gobo 1 shake Fast - slow
115~185
Forward Fast-Slow
186~255
Backward Slow-Fast

6
10
7
Rotation Gobo Wheel
0~7
Open
8~15
Gobo 1
16~23
Gobo 2
24~31
Gobo 3
32~39
Gobo 4
40~47
Gobo 5
48~55
Gobo 6
56~63
Gobo 7
64~70
Gobo 7 shake Fast - slow
71~77
Gobo 6 shake Fast - slow
78~84
Gobo 5 shake Fast - slow
85~91
Gobo 4 shake Fast - slow
92~99
Gobo 3 shake Fast - slow
100~107
Gobo 2 shake Fast - slow
108~114
Gobo 1 shake Fast - slow
115~185
Forward Fast-Slow
186~255
Backward Slow-Fast
11
8
Gobo Rotation
0~127
Gobo index
128~187
Gobo Forward Rotation(Fast-Slow)
188~194
Stop
195~255
Gobo Backward Rotation(Slow-Fast)
12
9
0~128
Iris Index
129~255
Iris Pulse
13
10
0~127
NO
128~255
Frost
14
11
Prism
0~10
Open
11~128
Prism 1 8 faced
129~255
Prism 2 6 linear
15
12
Prism1 Rotation
0~128
Prism 1 index
129~187
Prism 1 Backward Rotation Fast-Slow
188~255
Prism 1 Forward Rotation Slow-Fast
16
13
Prism2 Rotation
0~128
Prism 2 index
129~187
Prism 2 Backward Rotation Slow-Fast
188~255
Prism 2 Forward Rotation Slow-Fast
17
14
0~255
Zoom
18
15
0~255
Focus
19
16
0~127
NO
128~255
All-Reset
*BASED ON VERSION HM02

7
4. RIGGING THE FIXTURE
Caution:
•Fixture may cause severe damage when falling down. If you have doubts concerning the safety of a possible
installation, do not install the moving head.
•Before rigging make sure that the installation area can hold a minimum point load of 10 times the fixtures
weight.
•When installing the device, make sure there is no highly inflammable material (decoration material etc.) in a
distance of 1.0 m.
•Use an appropriate clamp to rig the fixture on the truss.
•Follow the instructions mentioned at the bottom of the base.
•Make sure that the device is fixed properly. Ensure that the structure (truss) to which you are attaching the
fixtures is secure.
Securing the fixture via one safety wire Securing the fixture via two safety wires
5. FEATURES
•Multi-Colors + gobo’s
•Color strobe
•Electronic Dimming 0-100%
•DMX-512 protocol
•Master/Slave synchronization
•LCD operation menu with function buttons
•Daisy Chain units together in DMX Mode

8
6. TECHNICAL SPECIFICATIONS
Electrical
•Power supply: Electronic auto-ranging
•Input voltage range: 90-250V, 50/60Hz
•Fuse: 5 A@220V
•Power consumption: 300W@230V
Optic
•Light source: LumiEngin 1piece *200W
White LED
•LED lifespan: 6,0000 hours
•Dimmer: Smooth dimmer from 0-100%
•Fixed gobo wheel: 7 gobos + open
•Rotating gobo wheel: 7 gobos + open
•Color wheel: 8 colors + open
•6 linear + 8-facet dual prisms
•Focus, Frost & Iris
Motorized
•Pan/Tilt
•Pan movement range: 540°
•Tilt movement range: 270°
•16 bit movement resolution
•Automatic Pan/Tilt position correction
•Pan movement 0°-540°at max Speed: 2.2 sec.
•Tilt movement 0°-270°at max Speed: 1.2 sec.
LCD operation
•Built-in demo sequences
•Silent cooling fans
•Strong three-phase motors
•Stand-alone operation
•Supported protocols: DMX512
•2 DMX modes (19/16 control channels)
Connection
•DMX data in/out: Locking 3-pin and 5-pin XLR
•AC power input: 1.5m power cord with plug
Rigging
•Mounting points: 2 pairs of 1/4-turn locks
•Mounting horizontally or vertically via 2 Omega
brackets
Temperatures
•Maximum ambient temperature: 45⁰C
•Maximum housing temperature: 75⁰C
•Total heat dissipation: 1200 BTU/h (calculated)
Dimensions
•Net dimensions: 380(L) x 247(W) x 550(H) mm
•Weight (net): 22kg

ALL SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE
BSL B.V.|SPAARPOT 19 |5667 KV GELDROP |THE NETHERLANDS
+31 (0)40 750 24 95
WWW.BSL-LIGHTING.COM |WWW.LIGHT-INC.EU
Table of contents
Other LIGHTINC Lighting Equipment manuals
Popular Lighting Equipment manuals by other brands

Atlantis
Atlantis STUDIOLIVEMAX BXYOUTUB02 user manual

Beghelli
Beghelli PACO-T20 instructions

Kaiser Fototechnik
Kaiser Fototechnik RB 520 AS operating instructions

LITESHEET
LITESHEET BriteCor AC Direct BHLB Series installation manual

Instarter
Instarter 23125 instruction manual

Cembre
Cembre CBL05-W Operation and maintenance manual