3
RUS Данный паспорт доступен для скачивания на сайте www.ltcompany.com в разделе «ПРОДУКЦИЯ»
ENG You are welcome to download the passport in the PRODUCT section on our web-site www.ltcompany.com
KAZ Бұл төлқұжаты сiз www.ltcompany.com сайтынан, «ӨНІМДЕР» бөлімінен жүктеп аласыз
UKR Електронна ве`рсія паспорту доступна на сайті www.ltcompany.com в розділі «ПРОДУКЦІЯ»
3. Safety notice
Installation, cleaning and replacing of the components should be done only with mains power off. Contaminated glass should be cleaned with soft cloth and mild detergent.
ATTENTION! In case of luminaire malfunction it is prohibited to disassemble and repair the luminaire. One should report to manufacturer or specialized luminaire service.
4.1. Transportation, storage, installation, operation and disposal rules
4.1.1. Transportation in manufacturer's package could be done by any mode of transport as long as protection from mechanical damage and precipitation is provided.
4.1.2. The luminaries should be stored in closed, dry and ventilated places with ambient temperature from -25 to +50°С and relative humidity less 80%. Keep away from water.
4.1.3. The luminaire should be used according to «Standard code of customer electrical installations».
4.1.4. Remove mounting bracket by releasing four screws (fig. 1.1).
4.1.5. Place mounting bracket on mounting surface (fig. 1.2). Fasteners kit is not included in delivery set.
4.1.6. Place luminaire on mounting bracket and lock it in appropriate position with screws (fig. 1.3). Maximal tightening torque: for M5 screws - 8Nm, for M8 screws - 16 Nm.
4.1.7. Power cable brought out of casing through cable gland and clamped in it. Connect wires according to cable connector's electrical scheme (fig. 1.4a). Cable connector allows entry of
power cable with outer diameter 7-12 mm.
4.1.8. When needed to connect mains cable inside the luminaire (without cable connector), remove luminaire's cover by releasing screws, put mains cable through cable gland in casing and
clamp it. Attach conductors to terminals according to polarity shown (fig. 1.4b). Cable gland allows entry of power cable with outer diameter 6-10 mm. Replace luminaire's cover back and
tighten the screws. Maximal tightening torque - 6 Nm.
4.1.9. Fasten the luminaire with safety wire if needed. (Fig. 1.5). Safety wire doesn't included in delivery set
4.1.10. The luminaire does not contain harmful materials and substances that require special disposal methods.
4.2. LEADER LED HFD luminaries transportation, storage, installation, operation and disposal rules
4.2.1. Transportation in manufacturer's package could be done by any mode of transport as long as protection from mechanical damage and precipitation is provided.
4.2.2. The luminaries should be stored in closed, dry and ventilated places with ambient temperature from -25 to +50°С and relative humidity less 80%. Keep away from water.
4.2.3. The luminaire should be used according to «Standard code of customer electrical installations».
4.2.4. Remove mounting bracket by releasing four screws (fig. 2.1).
4.2.5. Place mounting bracket on mounting surface (fig. 2.2). Fasteners kit is not included in delivery set.
4.2.6. Place luminaire on mounting bracket and lock it in appropriate position with screws (fig. 2.3). Maximal tightening torque: for M5 screws - 8Nm, for M8 screws - 16 Nm.
4.2.7. Remove luminaire's cover by releasing screws, put 5-wire mains cable through cable gland into the casing and lock it. Cable gland allows entry of power cable with outer diameter 6-10
mm. Connect power wires to terminals according to polarity shown: L, N, PE, DA and DA. (fig. 2.4).
When using DALI control, control wires are connected to terminals block (DA and DA) regardless of polarity. Fix the cover on the luminaire by tightening the screws. Maximal tightening torque -
6 Nm.
4.2.8. Fasten the luminaire with safety wire if needed. (Fig. 2.5). Safety wire doesn't included in delivery set.
4.2.9. The luminaire does not contain harmful materials and substances that require special disposal methods.
5. Acceptance assurance
The luminaire complies with the TOR 3461-006-44919750-13 and recognized ready for operation.
The luminaire is certified.
Manufacture date
Inspector _______________________________________________________________________________________________________________________________________________
Packer _________________________________________________________________________________________________________________________________________________
Manufacturer: LLC "Lighting Technologies IGC"
Manufacturer address: Russia, Ryazan, Magistralnya str., 10а, 390010.
6. Warranty
6.1. The manufacturer shall, at no additional cost to the customer, repair or replace a luminaire that has been found to be defective under normal use through no fault of the customer, subject to
the installation instructions having been followed, during the warranty period.
6.2. The luminaire is a servicable device. When installing the luminaire, free access should be provided for service or repair. The manufacturer is not responsible and will not compensate any
expenses related to construction work, rental vehicles etc in case the repair site is not readily accessible.
6.3. Warranty period - 36 months from date of luminaire delivery.
6.4. Warranty does not apply to color change of painted surfaces and plastic parts during luminaire operation.
6.5. Warranty period of emergency power supply units (supplied with rechargeable battery) and illumination control system components (supplied without luminaires) is 12 (twelve) months from
date of delivery.
6.6. Luminous flux level is at least 70% of the nominal value during the warranty period, CCT value and allowable CCT range - according to GOST R 54350.
6.7. Warranty will cover the entire period, given that assembly, installation and operation of luminaires are handled by specialized technical personnel and according to the luminaire's manual.
6.8. The service life of the luminaires under normal climatic conditions subject to installation and usage instructions is:
8 years –for luminaires with body and/or optical parts (diffuser) made of polymeric materials.
10 years - all other luminaries.
6.9. The manufacturer reserves the right to make modifications to the product that improve its end-user performance. Moreover, the manufacturer is not liable for typographical and other errors
that may have occurred in printing.
Date of sale _____________________________________________________________________________________________________________________________________________
Store stamp