Job Information Type:
Lytecaster®Performance Recessed CFL Downlighting 2001L
Page 2 of 2 3 ¾" Aperture Vertical Wet Location, Compact Fluorescent, Performance Series,
Reflector Trim
18W TRIPLE TUBE LAMP, LUMEN RATING = 1200 LMS, ELECTRONIC BALLAST, CL FINISH TRIM WITH FRESNEL LENS
18W TRIPLE TUBE LAMP, LUMEN RATING = 1200 LMS, ELECTRONIC BALLAST, CL FINISH TRIM WITH OPAL LENS
18W TRIPLE TUBE LAMP, LUMEN RATING = 1200 LMS, ELECTRONIC BALLAST, CL FINISH TRIM WITH CLEAR LENS
COEFFICIENTS OF UTILIZATION
Ceiling 80% 70% 50% 30%
Wall 70 50 30 10 50 10 50 10 50 10 0
RCR Zonal Cavity Method - Effective Floor Reflectance = 20%
Room Cavity Ratio
0 36 36 36 36 35 35 34 34 32 32 30
1 34 33 32 31 32 31 31 30 30 29 27
2 32 30 28 27 29 26 28 27 26 27 24
3 29 27 25 23 26 23 26 23 25 22 21
4 27 24 22 20 24 20 23 20 22 20 19
5 25 22 20 18 22 18 21 18 20 17 17
6 24 20 18 16 20 16 19 16 19 16 15
7 22 18 16 14 18 14 18 14 17 14 13
8 20 17 14 13 17 13 16 13 16 13 12
9 19 15 13 12 15 12 15 11 15 11 11
10 18 14 12 11 14 10 14 10 14 10 10
Determined In Accordance With Current IES Published Procedures
Luminaire Input Watts = 22.0
50
100
150
200
60˚
30˚
SC = 1.6
CERTIFIED TEST REPORT NO. 3349FR
COMPUTED BY LSI PROGRAM
**TEST-LITE**
ZONAL LUMENS AND PERCENTAGES
Zone Lumens %Lamp %Fixt
0-30 139.25 11.6 38.1
0-40 232.59 19.4 63.6
0-60 353.98 29.5 96.8
0-90 365.87 30.5 100
90-120 0 0 0
90-130 0 0 0
90-150 0 0 0
90-180 0 0 0
0-180 365.87 30.5 100
** Efficiency = 30.5%**
ZONAL LUMEN SUMMARY
Zone Lumens
0-10 13.37
10-20 46.72
20-30 79.16
30-40 93.34
40-50 79.65
50-60 41.74
60-70 10.17
70-80 1.58
80-90 .14
90-100 0
100-110 0
110-120 0
120-130 0
130-140 0
140-150 0
150-160 0
160-170 0
170-180 0
CANDLEPOWER SUMMARY
Angle 0˚ CP
0 129
5 135
10 150
15 165
20 173
25 172
30 165
35 150
40 131
45 104
50 74
55 46
60 24
65 8
70 3
75 1
80 1
85 0
90 0
COEFFICIENTS OF UTILIZATION
Ceiling 80% 70% 50% 30%
Wall 70 50 30 10 50 10 50 10 50 10 0
RCR Zonal Cavity Method - Effective Floor Reflectance = 20%
Room Cavity Ratio
0 35 35 35 35 34 34 33 33 31 31 30
1 33 32 31 30 31 30 29 28 27 27 26
2 31 29 27 26 28 25 27 25 26 24 23
3 28 26 24 22 25 22 24 22 24 21 20
4 26 23 21 19 23 19 22 19 21 19 18
5 24 21 19 17 21 17 20 17 20 17 16
6 23 19 17 15 19 15 18 15 18 15 14
7 21 17 15 13 17 13 17 13 16 13 13
8 20 16 14 12 16 12 13 15 13 12 11
9 18 15 12 11 15 11 14 11 14 11 10
10 17 14 11 10 13 10 13 10 13 10 9
Determined In Accordance With Current IES Published Procedures
Luminaire Input Watts = 22.0
50
100
150
200
60˚
30˚
SC = 1.4
CERTIFIED TEST REPORT NO. 3348FR
COMPUTED BY LSI PROGRAM
**TEST-LITE**
ZONAL LUMENS AND PERCENTAGES
Zone Lumens %Lamp %Fixt
0-30 131.6 11 37
0-40 217.11 18.1 61.1
0-60 333.76 27.8 93.9
0-90 355.26 29.6 100
90-120 0 0 0
90-130 0 0 0
90-150 0 0 0
90-180 0 0 0
0-180 355.26 29.6 100
** Efficiency = 29.6%**
ZONAL LUMEN SUMMARY
Zone Lumens
0-10 14.54
10-20 44.62
20-30 72.45
30-40 85.51
40-50 73.84
50-60 42.8
60-70 16.63
70-80 4.73
80-90 .14
90-100 0
100-110 0
110-120 0
120-130 0
130-140 0
140-150 0
150-160 0
160-170 0
170-180 0
CANDLEPOWER SUMMARY
Angle 0˚ CP
0 151
5 152
10 154
15 157
20 159
25 158
30 151
35 138
40 119
45 97
50 71
55 47
60 28
65 16
70 9
75 4
80 1
85 0
90 0
50
100
150
200
60˚
30˚
SC = 1.1
CERTIFIED TEST REPORT NO. 3350FR
COMPUTED BY LSI PROGRAM
**TEST-LITE**
COEFFICIENTS OF UTILIZATION
Ceiling 80% 70% 50% 30%
Wall 70 50 30 10 50 10 50 10 50 10 0
RCR Zonal Cavity Method - Effective Floor Reflectance = 20%
Room Cavity Ratio
0 31 31 31 31 30 30 29 29 28 28 26
1 29 28 27 26 27 26 26 25 25 24 23
2 27 25 23 22 24 22 23 21 23 21 20
3 24 22 20 19 22 19 21 18 20 18 17
4 23 20 18 16 20 16 19 16 18 16 15
5 21 18 16 14 18 14 17 14 17 14 13
6 19 6 14 13 16 13 16 12 15 12 12
7 18 15 13 11 15 11 14 11 14 11 11
8 17 14 12 10 13 10 13 10 13 10 9
9 16 13 11 9 12 9 12 9 12 9 9
10 15 12 10 8 12 8 11 8 11 8 8
Determined In Accordance With Current IES Published Procedures
Luminaire Input Watts = 22.0
ZONAL LUMENS AND PERCENTAGES
Zone Lumens %Lamp %Fixt
0-30 111.65 9.3 35.8
0-40 175.81 14.7 56.4
0-60 279.09 23.3 89.6
0-90 311.48 26 100
90-120 0 0 0
90-130 0 0 0
90-150 0 0 0
90-180 0 0 0
0-180 311.48 26 100
** Efficiency = 26%**
ZONAL LUMEN SUMMARY
Zone Lumens
0-10 14.23
10-20 39.88
20-30 57.54
30-40 64.16
40-50 58.87
50-60 44.41
60-70 25.17
70-80 7.09
80-90 .14
90-100 0
100-110 0
110-120 0
120-130 0
130-140 0
140-150 0
150-160 0
160-170 0
170-180 0
CANDLEPOWER SUMMARY
Angle 0˚ CP
0 151
5 150
10 147
15 142
20 134
25 125
30 115
35 103
40 90
45 76
50 63
55 50
60 37
65 25
70 15
75 6
80 1
85 0
90 0