Lightolier Calculite C12E28VW User manual

Calculite®HID Downlight C12E28VW
Page 1 of 2 12" Aperture, ED28 (Enclosed) Metal Halide, Wide Beam
Job Information Type:
Job Name:
Cat. No.:
Lamp(s):
Notes:
Lightolier a Genlyte Thomas Company www.lightolier.com
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
© 2004 Genlyte Thomas Group LLC (Lightolier Division) • AO5O4
Ceiling Cutout: 12 9/16” (256mm) Dia.
Reflector Trim Frame-In Kit Lamp (Enclosed, Coated)
C12E28VW CLW Specular Clear, White Painted Flange.
CLP Specular Clear, Matching Flange.
CCDW Comfort Clear Diffuse, White Painted Flange.
CCDP Comfort Clear Diffuse, Matching Flange.
CCZW Champagne Bronze, White Painted Flange.
CCZP Champagne Bronze, Matching Flange.
C1217MHPU Magnetic, Pulse Start, 120V/277V 175W ED28, BT28 PS MH
C1225MHPU Magnetic, Pulse Start, 120V/277V 250W ED28, BT28 PS MH
C1232MHPU Magnetic, Pulse Start, 120V/277V 320W ED28, BT28 PS MH
C1240MHPU Magnetic, Pulse Start, 120V/277V 400W ED28, BT28 PS MH
C1217MHU Magnetic, 120V/277V 175W ED28, BT28 MH
C1225MHU Magnetic, 120V/277V 250W ED28, BT28 MH
C1240MHU Magnetic, 120V/277V 400W ED28, BT28 MH
Features
1. Upper Reflector: Clear anodized aluminum, 0.040" (16-ga.). Provides wide
beam optics ideal for general lighting. Also available in narrow beam, see
C12E28VN specification sheet.
2. Aperture Cone: Low brightness with 40° cut-off to lamp. Specular Clear or
Comfort Clear™ Diffuse, or champagne bronze self-flanged in painted white
or aperture-matching polished flange. Consult factory for other finishes.
3. Lamp Shield: High-temperature glass as required by code, captive during
re-lamping.
4. Socket Cup: Heat dissipating, die-cast aluminum, pre-wired with mogul base
porcelain socket with nickel plated screw shell. Postive locking attachment
without tools to reflector assures proper optical alignment of lamp.
5. Mounting Frame: 0.048" (18-ga.) galvanized steel, includes pre-installed
mounting bars.
6. Mounting Ring: 0.048"(18-ga.) galvanized steel. Designed for vertical
adjustment from above or below for ceilings from 0" to 2" thick. Center-line
notches allow consistent alignment of multiple fixtures.
7. Retention Springs: Rust resistant springs secure cone for quick, tool-less
installation.
8. Frame Vertical Adjustment: Vertical adjustment mechanism accommodates
mounting to virtually any ceiling system using mounting bars (provided, or
1/2" EMT tubing (by others). Single locking feature secures all adjustments.
Alignment holes and markings allow fixture to be preset prior to installation.
9. Mounting Bars: 0.048" (18-ga.) pre-installed, telescoping bars extend to 30" long
and lock securely into position. Built-in locking tabs provide positive attachment
to common T-bar systems. Self-centering feature simplifies installation in 24"
O.C. grid systems. Attaches to steel or wood joists without accessories.
10. Ballast: Pulse Start
11.Junction Box: 0.059" (16-ga.) galvanized steel. UL listed for 8 No. 12 AWG,
90°C through branch circuit conductors. Allows inspection from below.
12.Thermal Protector: Meets NEC and UL requirements. Do not install
insulation above nor within 3" (76mm) of any part of the luminaire.
Electrical
Magnetic Ballast: 120/277V dual voltage, 60 Hz., encased and potted, CWA or
Super CWA (pulse start) circuit type, high power factor, sound rating “B” (175W
and 250W PS)/sound rating “C” (others), -20°F minimum starting Temperature,
Type 1 Outdoor rating.
Electrical (cont.)
Ballast ANSI Code Voltage Max. Amps Input Watts
175W PS MH M137 120/277 2.20/0.90 205
250W PS MH M138 120/277 2.80/1.20 290
320W PS MH M132 120/277 3.40/1.50 370
400W PS MH M135 120/277 4.10/1.80 465
175W MH M57 120/277 2.00/0.90 205
250W MH M58 120/277 2.60/1.10 290
400W MH M59 120/277 3.90/1.70 460
Options and Accessories
Auxiliary: Add suffix Ato Frame-In Kit and Reflector Trim. See Spec.Sheet ”A“.
Emergency: Add suffix Eto Reflector Trim and Frame-In Kit. See Spec. Sheet “E”.
Slope Ceiling Adapters: See Specification Sheet SCA.
Fuse (magnetic ballast): Add suffix F1 or F2 to Frame in Kit (F1=120V, F2=277V).
Chicago Plenum: Consult Factory.
Labels
UL (Suitable for Damp Locations), CSA, I.B.E.W.
For 320W/400W, install fixtures with minimum spacing: 4 feet from center-to-
center of adjacent luminaries; 3 inch from top of luminaire to overhead building
member; 2 feet from luminaire center to side building member.
320W ED28 PHILIPS MH COATED LAMP, LUMEN RATING = 30100 LMS, ADVANCE BALLAST PULSE START MAGNETIC, CL FINISH TRIM
2,750
5,500
8,250
11,000 30°
60°
ANGLE MEAN CP LUMENS
0 10325
5 10384 994
10 10573
15 10304 2894
20 9659
25 8898 4099
30 7970
35 7756 4746
40 6738
45 4730 3513
50 1945
55 198 526
60 4
65 0 1
70 0
75 0 0
80 0
85 0 0
90 0
ZONAL LUMENS AND PERCENTAGES
ZONE LUMENS % LAMP %LUMINAIRE
0-30 7987 26.54 47.62
0-40 12733 42.3 75.92
0-60 16771 55.72 99.99
0-90 16772 55.72 100
40-90 4039 13.42 24.08
60-90 1 0 0.01
90-180 0 0 0
0-180 16772 55.72 100
LUMINANCE SUMMARY - CD. / SQ. M.
ANGLE MEAN CD/SQ M
45 92020
55 4756
65 0
75 0
85 0
*** EFFICIENCY = 55.7% ** CERTIFIED TEST REPORT NO. 2413FR, DATE: FEB 10, 2004
SC = 1.2 COMPUTED BY LSI PROGRAM **TEST-LITE**
CEILING 80% 70% 50% 30%
WALL 70 50 30 10 50 10 50 10 50 10 0
RCR0 .66 .66 .66 .66 .65 .65 .62 .62 .59 .59 .56
1 .63 .62 .60 .59 .60 .58 .58 .56 .56 .54 .52
2 .60 .57 .55 .53 .56 .52 .54 .51 .53 .50 .48
3 .57 .53 .50 .48 .52 .48 .51 .47 .50 .46 .45
4 .54 .49 .46 .44 .49 .43 .48 .43 .46 .43 .41
5 .51 .46 .42 .40 .45 .40 .44 .39 .43 .39 .38
6 .48 .42 .39 .36 .42 .36 .41 .36 .40 .36 .35
7 .45 .39 .35 .33 .39 .33 .38 .33 .37 .32 .31
8 .42 .36 .32 .30 .35 .30 .35 .30 .34 .29 .28
9 .39 .33 .29 .27 .33 .27 .32 .27 .32 .26 .26
10 .36 .30 .27 .24 .30 .24 .29 .24 .29 .24 .23
LUMINAIRE INPUT WATTS = 370.0
Coefficients of Utilization
Zonal Cavity Method - Effective Floor Cavity Reflectance = 20%
400W ED28 G.E. MH COATED LAMP. LUMEN RATING = 35000 LMS, ADVANCE MAGNETIC BALLAST, CL FINISH TRIM
5,000
10,000
15,000
20,000 30°
60°
ANGLE MEAN CP LUMENS
0 14097
5 14418 1399
10 15675
15 15612 4282
20 13529
25 11653 5440
30 10175
35 10432 6250
40 8760
45 6008 4499
50 2461
55 137 614
60 0
65 0 0
70 0
75 0 0
80 0
85 0 0
90 0
ZONAL LUMENS AND PERCENTAGES
ZONE LUMENS % LAMP %LUMINAIRE
0-30 11120 31.77 49.46
0-40 17370 49.63 77.26
0-60 22483 64.24 100
0-90 22483 64.24 100
40-90 5112 14.61 22.74
60-90 0 0 0
90-180 0 0 0
0-180 22483 64.24 100
LUMINANCE SUMMARY - CD. / SQ. M.
ANGLE MEAN CD/SQ M
45 207807
5 5858
65 0
75 0
85 0
** EFFICIENCY = 64.2% ** CERTIFIED TEST REPORT NO. 2521FR, DATE: MAR 14, 2004
SC = 1.1 COMPUTED BY LSI PROGRAM **TEST-LITE**
CEILING 80% 70% 50% 30%
WALL 70 50 30 10 50 10 50 10 50 10 0
RCR0 .76 .76 .76 .76 .75 .75 .71 .71 .68 .68 .64
1 .73 .71 .69 .68 .70 .67 .67 .65 .65 .63 .60
2 .69 .66 .64 .61 .65 .61 .63 .59 .61 .58 .56
3 .66 .61 .58 .56 .61 .55 .59 .54 .57 .54 .52
4 .62 .57 .54 .51 .57 .51 .55 .50 .54 .50 .48
5 .59 .53 .49 .46 .53 .46 .51 .46 .50 .45 .44
6 .55 .49 .45 .43 .49 .42 .48 .42 .47 .42 .41
7 .52 .46 .42 .39 .45 .38 .44 .38 .43 .38 .37
8 .49 .42 .38 .35 .42 .35 .41 .35 .40 .35 .34
9 .46 .39 .35 .32 .38 .32 .38 .32 .37 .31 .30
10 .43 .36 .32 .29 .35 .29 .35 .29 .34 .28 .27
LUMINAIRE INPUT WATTS = 460
Coefficients of Utilization
Zonal Cavity Method - Effective Floor Cavity Reflectance = 20%
Calculite®HID Downlight C12E28VW
Page 1 of 2 12" Aperture, ED28 (Enclosed) Metal Halide, Wide Beam
Lightolier a Genlyte Thomas Company www.lightolier.com
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
© 2004 Genlyte Thomas Group LLC (Lightolier Division) • AO5O4
Job Information Type:
175W ED28 G.E. MH COATED LAMP, LUMEN RATING = 12900 LMS, ADVANCE MAGNETIC BALLAST, CL FINISH TRIM
1,375
2,750
4,125
5,500 30°
60°
ANGLE MEAN CP LUMENS
0 5034
5 5057 489
10 5362
15 5266 1459
20 4701
25 4237 1967
30 3820
35 3715 2249
40 3070
45 2096 1574
50 866
55 85 233
60 2
65 0 1
70 0
75 0 0
80 0
85 0
90 0
ZONAL LUMENS AND PERCENTAGES
ZONE LUMENS % LAMP %LUMINAIRE
0-30 3915 30.35 49.12
0-40 6164 47.79 77.33
0-60 7970 61.79 99.99
0-90 7971 61.79 100
40-90 1807 14.01 22.67
60-90 0 0 0.01
90-180 0 0 0
0-180 7971 61.79 100
LUMINANCE SUMMARY - CD. / SQ. M.
ANGLE MEAN CD/SQ M
45 72490
55 3628
65 0
75 0
50
* ** EFFICIENCY = 61.8% ** CERTIFIED TEST REPORT NO. 2505FR, DATE: MAR 14, 2004
SC = 1.1 COMPUTED BY LSI PROGRAM **TEST-LITE**
CEILING 80% 70% 50% 30%
WALL 70 50 30 10 50 10 50 10 50 10 0
RCR0 .74 .74 .74 .74 .72 .72 .69 .69 .66 .66 .62
1 .70 .68 .67 .65 .67 .64 .64 .62 .62 .60 .58
2 .67 .64 .61 .59 .63 .58 .60 .57 .59 .56 .54
3 .63 .59 .56 .53 .58 .53 .57 .52 .55 .51 .50
4 .60 .55 .52 .49 .54 .49 .53 .48 .52 .48 .46
5 .56 .51 .47 .45 .50 .44 .49 .44 .48 .44 .42
6 .53 .47 .44 .41 .47 .41 .46 .40 .45 .40 .39
7 .50 .44 .40 .37 .43 .37 .42 .37 .42 .36 .35
8 .47 .40 .36 .34 .40 .33 .39 .33 .39 .33 .32
9 .44 .37 .33 .30 .37 .30 .36 .30 .36 .30 .29
10 .41 .34 .30 .27 .34 .27 .33 .27 .33 .27 .26
LUMINAIRE INPUT WATTS = 205.0
Coefficients of Utilization
Zonal Cavity Method - Effective Floor Cavity Reflectance = 20%
250W ED28 PHILIPS MH COATED LAMP, LUMEN RATING = 19475 LMS, UNIVERSAL MAGNETIC BALLAST, CL FINISH TRIM
2,125
4,250
6,375
8,500 30°
60°
ANGLE MEAN CP LUMENS
0 8217
5 8229 788
10 8325
15 8132 2277
20 7546
25 6737 3109
30 5850
35 5457 3333
40 4459
45 3040 2289
50 1286
55 130 348
60 4
65 0 1
70 0
75 0 0
80 0
85 0 0
90 0
ZONAL LUMENS AND PERCENTAGES
ZONE LUMENS % LAMP %LUMINAIRE
0-30 6174 31.7 50.84
0-40 9507 48.82 78.28
0-60 12143 62.36 99.99
0-90 12144 62.36 100
40-90 2637 13.54 21.72
60-90 0 0 0.01
90-180 0 0 0
0-180 12144 62.36 100
LUMINANCE SUMMARY - CD. / SQ. M.
ANGLE MEAN CD/SQ M
45 105132
55 5546
65 0
75 0
85 0
** EFFICIENCY = 62.4% ** CERTIFIED TEST REPORT NO. 2508FR, DATE: MAR 14, 2004
SC = 1.1 COMPUTED BY LSI PROGRAM **TEST-LITE*
CEILING 80% 70% 50% 30%
WALL 70 50 30 10 50 10 50 10 50 10 0
RCR0 .74 .74 .74 .74 .73 .73 .69 .69 .66 .66 .62
1 .71 .69 .67 .66 .68 .65 .65 .63 .63 .61 .58
2 .67 .64 .62 .60 .63 .59 .61 .58 .59 .57 .54
3 .64 .60 .57 .54 .59 .54 .57 .53 .56 .52 .50
4 .61 .56 .52 .50 .55 .49 .54 .49 .53 .48 .47
5 .57 .52 .48 .45 .51 .45 .50 .45 .49 .44 .43
6 .54 .48 .44 .42 .48 .42 .47 .41 .46 .41 .40
7 .51 .45 .41 .38 .44 .38 .43 .38 .43 .37 .36
8 .48 .41 .37 .35 .41 .34 .40 .34 .40 .34 .33
9 .45 .38 .34 .31 .38 .31 .37 .31 .37 .31 .30
10 .42 .35 .31 .28 .35 .28 .34 .28 .34 .28 .27
LUMINAIRE INPUT WATTS = 290.0
Coefficients of Utilization
Zonal Cavity Method - Effective Floor Cavity Reflectance = 20%

Other Lightolier Light Fixture manuals

Lightolier Lytecaster 1185 User manual

Lightolier

Lightolier Lytecaster 1185 User manual

Lightolier Lytespan 6276B User manual

Lightolier

Lightolier Lytespan 6276B User manual

Lightolier Calculite ProSpec PA2A1175 User manual

Lightolier

Lightolier Calculite ProSpec PA2A1175 User manual

Lightolier Walmaster WMRL244120SB User manual

Lightolier

Lightolier Walmaster WMRL244120SB User manual

Lightolier Lytecaster 2022 User manual

Lightolier

Lightolier Lytecaster 2022 User manual

Lightolier SOF-TECH Instructions for use

Lightolier

Lightolier SOF-TECH Instructions for use

Lightolier Calculite P7006 User manual

Lightolier

Lightolier Calculite P7006 User manual

Lightolier WES SERIES 2X4 User manual

Lightolier

Lightolier WES SERIES 2X4 User manual

Lightolier 48339ALU User manual

Lightolier

Lightolier 48339ALU User manual

Lightolier Helios 5410 Guide

Lightolier

Lightolier Helios 5410 Guide

Lightolier ProSpec 26230 User manual

Lightolier

Lightolier ProSpec 26230 User manual

Lightolier Calculite 7026AO User manual

Lightolier

Lightolier Calculite 7026AO User manual

Lightolier Lytecaster 300XTC User manual

Lightolier

Lightolier Lytecaster 300XTC User manual

Lightolier Calculite C4T4GA-MHT4RS User manual

Lightolier

Lightolier Calculite C4T4GA-MHT4RS User manual

Lightolier Calculite C4P20GA User manual

Lightolier

Lightolier Calculite C4P20GA User manual

Lightolier SM T5 Strip User manual

Lightolier

Lightolier SM T5 Strip User manual

Lightolier ProSpec 26800 User manual

Lightolier

Lightolier ProSpec 26800 User manual

Lightolier Lytecaster 1101FEL User manual

Lightolier

Lightolier Lytecaster 1101FEL User manual

Lightolier Decorative Arco 4833 User manual

Lightolier

Lightolier Decorative Arco 4833 User manual

Lightolier Lytespan 6282 User manual

Lightolier

Lightolier Lytespan 6282 User manual

Lightolier QHE2GPFOP228 User manual

Lightolier

Lightolier QHE2GPFOP228 User manual

Lightolier Lytespan 83ED17S User manual

Lightolier

Lightolier Lytespan 83ED17S User manual

Lightolier ProSpec Track system Instructions for use

Lightolier

Lightolier ProSpec Track system Instructions for use

Lightolier ProSpec 26056 User manual

Lightolier

Lightolier ProSpec 26056 User manual

Popular Light Fixture manuals by other brands

Clevertronics Trade EBS4N-LI Installation & maintenance instructions

Clevertronics

Clevertronics Trade EBS4N-LI Installation & maintenance instructions

Techly Led lamp Series user manual

Techly

Techly Led lamp Series user manual

Pro-Elec PEL00782 quick start guide

Pro-Elec

Pro-Elec PEL00782 quick start guide

BARRON Exitronix NY900U Series installation instructions

BARRON

BARRON Exitronix NY900U Series installation instructions

Eaton NFFLD-S installation instructions

Eaton

Eaton NFFLD-S installation instructions

Larson Electronics WAL-C-4XM instruction manual

Larson Electronics

Larson Electronics WAL-C-4XM instruction manual

Cooper Lighting Halo LZR311 Specification sheet

Cooper Lighting

Cooper Lighting Halo LZR311 Specification sheet

Larson Electronics GL-3 Series instruction manual

Larson Electronics

Larson Electronics GL-3 Series instruction manual

Halco ProLED Vapor Tight Series installation guide

Halco

Halco ProLED Vapor Tight Series installation guide

Cooper Lighting LUMARK M4 manual

Cooper Lighting

Cooper Lighting LUMARK M4 manual

Westinghouse W-042 owner's manual

Westinghouse

Westinghouse W-042 owner's manual

IKEA SOLVINDEN M1402-2 manual

IKEA

IKEA SOLVINDEN M1402-2 manual

Emos ZV1111 manual

Emos

Emos ZV1111 manual

GY-HITEC HM-SW30 user manual

GY-HITEC

GY-HITEC HM-SW30 user manual

Chauvet CH-BOB Jr. user guide

Chauvet

Chauvet CH-BOB Jr. user guide

RAB SLIM 57 installation instructions

RAB

RAB SLIM 57 installation instructions

Philips Lytespan 8108 specification

Philips

Philips Lytespan 8108 specification

Chauvet SlimPAR 64 RGBA user manual

Chauvet

Chauvet SlimPAR 64 RGBA user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.