manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Lightolier
  6. •
  7. Lighting Equipment
  8. •
  9. Lightolier Calculite C7E170HW User manual

Lightolier Calculite C7E170HW User manual

81539 7
2
6 4 8
Vertical Adjustment:
5/8" (16 mm) to
2 7/8" (73 mm)
2" (50 mm) max.
Ceiling Thickness
7-3/8" (187 mm) Dia.
8-1/2"
(216 mm)
(276 mm
8-5/8" (200 mm) Dia.
10-1/2"
(267 mm)
10-7/8"
(276 mm)
18-5/8" (473 mm)
Top View
(Magnetic Ballast)
8-1/4"
(210 mm)
20" (508 mm) to 30" (762 mm)
9-3/4"
(248 mm)
10-7/8"
(276 mm)
11-1/2"
(292 mm)
Top View
(Electronic Ballast)
9-3/4"
(248 mm)
20" (508 mm) to
30" (762 mm)
11" (280 mm)
(100/150W)
Job Information Type:
Job Name:
Cat. No.:
Lamp(s):
Notes:
Lightolier a Genlyte Thomas Company www.lightolier.com
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
© 2004 Genlyte Thomas Group LLC (Lightolier Division) • A0504
Features
1. Reflector: Clear anodized aluminum, 0.040" (16-ga.). Provides wide
beam distribution. Provides 50° visual cut-off to lamp and lamp image;
self-flange in painted white or aperture-matching polished flange.
Consult factory for other finishes.
2. Socket Housing: Galvanized steel, pre-wired with medium base pulse rated
socket. Snaps onto upper reflector for secure attachment without tools;
unitized construction assures proper lamp alignment to optics for consistent
performance.
3. Mounting Frame: 0.048" (18-ga.) galvanized steel includes pre-installed
mounting bars.
4. Mounting Ring: 0.048" (18-ga.) galvanized steel. Designed for vertical
adjustment from above or below for ceilings from 0" to 2" thick. Center-line
notches allow consistent alignment of multiple fixtures.
5. Retention Springs: Rust resistant springs secure cone in place for quick,
tool-less installation.
6. Frame Vertical Adjustment Mechanism: Vertical adjustment mechanism
accommodates mounting to virtually any ceiling system using pre-installed
mounting bars, or 1/2" EMT tubing (by others). Single locking feature secures
all adjustments. Alignment holes and markings allow fixture to be pre-set
prior to installation.
7. Mounting Bars: 0.048" (18-ga.) Pre-installed, telescoping bars extend to
30" long and lock securely into position. Built-in locking tabs provide positive
attachment to common T-bar systems. Self-centering feature simplifies
installation in 24" O.C. grid systems. Attaches to steel or wood joists
without accessories.
8. Ballast: Electronic 120V or 277V. Magnetic dual voltage (120V & 277V).
Accessible from below for inspection and/or replacement without tools.
9. Junction Box: 0.048" (18-ga.) galvanized steel. UL listed for 8 No. 12 AWG,
90°C through branch circuit conductors; allows inspection from below.
10. Thermal Protector: (Not Shown) Meets NEC and UL requirements. Do not
install insulation above nor within 3" (76mm) of any part of the luminaire.
Electrical
Electronic Ballast: 120V or 277V, 50/60 Hz., encased, high-power factor, T.H.D.
<15%, thermally and transient protected, RMI / RFI complies with FCC Part 18
non-consumer equipment, shut-down circuit at end of lamp life, sound rating "A",
-50°F minimum starting temperature, Type 1 outdoor rating.
Electrical (cont.)
Ballast ANSI Code Voltage Max. Amps Input Watts
70W MH M98/M139 120/277 0.67/0.29 78
100W MH M90/M140 120/277 0.90/0.43 110
150W MH M102 120/277 1.40/0.61 167
Magnetic Ballast: 120/277V dual voltage, 60 Hz., encased and potted, HX-HPF
circuit type, high power factor, sound rating "B", -20°F minimum starting
temperature, Type 1 Outdoor rating.
Ballast ANSI Code Voltage Max. Amps Input Watts
70W MH M98/M143 120/277 1.90/0.80 94
100W MH M90/M140 120/277 2.40/1.10 125
150W MH M102 120/277 3.70/1.60 180
Options and Accessories
Auxiliary: Add suffix Ato Frame-In Kit and Reflector Trim. c ”A“.
Emergency Lamp: Add suffix Eto Reflector Trim and Frame-In Kit.
See Spec. Sheet “A/E”.
Slope Ceiling Adapters: See Specification Sheet SCA.
Chicago Plenum: Consult Factory.
Fuse: (Magnetic Ballast): Add suffix F1 or F2 to Frame in Kit (F1=120V, F2=277V).
Labels
UL (Suitable for Damp Locations), CSA, I.B.E.W. For 150W, install fixtures
with minimum spacing: 3 feet from center-to-center of adjacent luminaries; 3
inch from top of luminaire to overhead building member;1 1/2 feet from luminaire
center to side building member.
Ceiling Cutout: 8" (203 mm) Dia.
Reflector Trim Frame-In Kit Lamp (Coated, Ceramic MH)
C7E17OHW CLW Specular Clear, White Painted Flange. C770MHOE1 Electronic 120V C770MHOE2 Electronic 277V 70W E17, ED17, BD17, (Open Rated)
CLP Specular Clear, Matching Flange. C710MHOE1 Electronic 120V C710MHOE2 Electronic 277V 100W E17, ED17, BD17, (Open Rated)
CCDW Comfort Clear Diffuse, White Painted Flange. C715MHOE1 Electronic 120V C715MHOE2 Electronic 277V 150W E17, ED17, BD17, (Open Rated)
CCDP Comfort Clear Diffuse, Matching Flange. C770MHOU Magnetic 120V/277V 70W E17, ED17, BD17, (Open Rated)
CCZW Champagne Bronze, White Painted Flange. C710MHOU Magnetic 120V/277V 100W E17, ED17, BD17, (Open Rated)
CCZP Champagne Bronze, Matching Flange. C715MHOU Magnetic 120V/277V 150W E17, ED17, BD17, Open Rated)
Calculite® HID Downlight C7E170HW
Page 1 of 2 7" Aperture, ED17 (Open Rated), Ceramic Metal Halide, Wide Beam
8
Calculite® HID Downlight C7E170HW
Page 2 of 2 7" Aperture, ED17 (Open Rated), Ceramic Metal Halide, Wide Beam
Lightolier a Genlyte Thomas Company www.lightolier.com
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
© 2004 Genlyte Thomas Group LLC (Lightolier Division) • A0504
Job Information Type:
1,500
750
2,250
3,000
2,500
1,250
3,750
5,000
30°
60°
30°
60°
70W ED17 (ENCLOSED) PHILIPS COATED METAL HALIDE LAMP. LUMEN RATING = 5700 LMS., AROMAT ELECTRONIC BALLAST, CL FINISH REFLECTOR TRIM
ANGLE 0° 45° 90°
0 2517 2517 2517
5 2462 2535 2572
10 2242 2537 2678
15 2201 2705 2823
20 2230 2610 2778
25 2233 2365 2464
30 1916 2096 2180
35 1322 1698 1886
40 823 1127 1271
45 234 349 480
50 20 20 51
55 5 8 8
60 2 3 3
65 0 1 1
70 0 1 0
75 0 0 0
80 0 0 0
85 0 0 0
90 0 0 0
ZONAL LUMENS AND PERCENTAGES
ZONE LUMENS % LAMP %LUMINAIRE
0-30 2050 35.98 59.89
0-40 3062 53.73 89.44
0-60 3423 60.05 99.96
0-90 3424 60.08 100
40-90 361 6.34 10.56
60-90 1 0.02 0.04
90-180 0 0 0
0-180 3424 60.08 100
LUMINANCE SUMMARY - CD. / SQ. M.
ANGLE 0 Deg. 45 Deg. 90 Deg.
45 11611 17393 23922
55 306 466 466
65 0 71 57
75 0 23 0
85 0 0 0
** EFFICIENCY = 60.1% ** CERTIFIED TEST REPORT NO. 2418FR, DATE: FEB 10, 2004
SC = 1.1 COMPUTED BY LSI PROGRAM **TEST-LITE**
CEILING 80% 70% 50% 30%
WALL 70 50 30 10 50 10 50 10 50 10 0
RCR
0 .72 .72 .72 .72 .70 .70 .67 .67 .64 .64 .60
1 .68 .67 .66 .64 .66 .63 .63 .61 .61 .59 .57
2 .65 .63 .61 .59 .62 .58 .60 .57 .58 .56 .54
3 .62 .59 .56 .54 .58 .54 .57 .53 .55 .52 .50
4 .60 .56 .52 .50 .55 .50 .54 .49 .52 .49 .47
5 .57 .52 .49 .46 .51 .46 .50 .46 .49 .45 .44
6 .54 .49 .46 .43 .48 .43 .48 .43 .47 .42 .41
7 .51 .46 .42 .40 .45 .40 .45 .40 .44 .39 .38
8 .48 .43 .39 .37 .42 .37 .42 .37 .41 .36 .36
9 .46 .40 .36 .34 .40 .34 .39 .34 .39 .34 .33
10 .43 .37 .34 .31 .37 .31 .36 .31 .36 .31 .30
LUMINAIRE INPUT WATTS = 78.0
Coefficients of Utilization
Zonal Cavity Method - Effective Floor Cavity Reflectance = 20%
100W ED17 (ENCLOSED) PHILIPS COATED METAL HALIDE LAMP. LUMEN RATING = 8500 LMS., AROMAT, ELECTRONIC BALLAST, CL FINISH REFLECTOR TRIM
ANGLE 0° 45° 90°
0 4622 4622 4622
5 4767 4575 4529
10 4783 4421 4539
15 4151 4423 4544
20 3703 4033 4286
25 3387 3501 3570
30 3033 3024 3064
35 2201 2273 2443
40 1410 1566 1617
45 501 615 580
50 63 56 62
55 19 19 18
60 10 12 9
65 5 7 5
70 3 3 2
75 1 1 0
80 0 0 0
85 0 0 0
90 0 0 0
ZONAL LUMENS AND PERCENTAGES
ZONE LUMENS % LAMP %LUMINAIRE
0-30 3282 38.62 62.14
0-40 4720 55.54 89.35
0-60 5275 62.07 99.86
0-90 5283 62.15 100
40-90 562 6.62 10.65
60-90 7 0.08 0.14
90-180 0 0 0
0-180 5283 62.15 100
LUMINANCE SUMMARY - CD. / SQ. M.
ANGLE 0 Deg. 45 Deg. 90 Deg.
45 24858 30607 28891
55 1140 1179 1075
65 422 611 376
75 153 153 0
85 0 0 0
** EFFICIENCY = 62.2% ** CERTIFIED TEST REPORT NO. 2267FR , DATE: JUN 23, 2003
SC = 1.1 COMPUTED BY LSI PROGRAM **TEST-LITE**
CEILING 80% 70% 50% 30%
WALL 70 50 30 10 50 10 50 10 50 10 0
RCR
0 .74 .74 .74 .74 .72 .72 .69 .69 .66 .66 .62
1 .71 .69 .68 .67 .68 .66 .65 .64 .63 .62 .59
2 .68 .65 .63 .61 .64 .60 .62 .59 .60 .58 .56
3 .65 .61 .58 .56 .60 .56 .59 .55 .57 .54 .52
4 .62 .58 .55 .52 .57 .52 .56 .51 .55 .51 .49
5 .59 .54 .51 .48 .54 .48 .53 .48 .52 .47 .46
6 .56 .51 .48 .45 .51 .45 .50 .45 .49 .45 .43
7 .53 .48 .45 .42 .48 .42 .47 .42 .46 .41 .40
8 .51 .45 .42 .39 .45 .39 .44 .39 .43 .39 .38
9 .48 .42 .39 .36 .42 .36 .41 .36 .41 .36 .35
10 .45 .40 .36 .34 .39 .34 .39 .33 .38 .33 .32
LUMINAIRE INPUT WATTS = 110
Coefficients of Utilization
Zonal Cavity Method - Effective Floor Cavity Reflectance = 20%
45°

Other Lightolier Lighting Equipment manuals

Lightolier FW01 User manual

Lightolier

Lightolier FW01 User manual

Lightolier Lytespan 23S20BT User manual

Lightolier

Lightolier Lytespan 23S20BT User manual

Lightolier Calculite C6T6W User manual

Lightolier

Lightolier Calculite C6T6W User manual

Lightolier Aleron A-8 User manual

Lightolier

Lightolier Aleron A-8 User manual

Lightolier Lighting Systems Baselyte-BSL24 User manual

Lightolier

Lightolier Lighting Systems Baselyte-BSL24 User manual

Lightolier Lytespan 9220 User manual

Lightolier

Lightolier Lytespan 9220 User manual

Lightolier Wal-Master WMRL124120SB User manual

Lightolier

Lightolier Wal-Master WMRL124120SB User manual

Lightolier Calculite ProSpec PB4A1175 User manual

Lightolier

Lightolier Calculite ProSpec PB4A1175 User manual

Lightolier Lytecaster 2003R User manual

Lightolier

Lightolier Lytecaster 2003R User manual

Lightolier LFK3 User manual

Lightolier

Lightolier LFK3 User manual

Lightolier CD7-1 User manual

Lightolier

Lightolier CD7-1 User manual

Lightolier Lighting Systems Baselyte-BSL16 User manual

Lightolier

Lightolier Lighting Systems Baselyte-BSL16 User manual

Lightolier LFK4 User manual

Lightolier

Lightolier LFK4 User manual

Lightolier Calculite C4T4A-MHT4RF User manual

Lightolier

Lightolier Calculite C4T4A-MHT4RF User manual

Lightolier CD7-5 User manual

Lightolier

Lightolier CD7-5 User manual

Lightolier Lytecaster 2000LV User manual

Lightolier

Lightolier Lytecaster 2000LV User manual

Lightolier TRACK COUPLE Instructions for use

Lightolier

Lightolier TRACK COUPLE Instructions for use

Lightolier CTS3-14 User manual

Lightolier

Lightolier CTS3-14 User manual

Lightolier Lytecel Linear LL4MF8LR154 User manual

Lightolier

Lightolier Lytecel Linear LL4MF8LR154 User manual

Lightolier Lytespan 8277 User manual

Lightolier

Lightolier Lytespan 8277 User manual

Lightolier PLA2G9LP32U User manual

Lightolier

Lightolier PLA2G9LP32U User manual

Lightolier FA01 User manual

Lightolier

Lightolier FA01 User manual

Lightolier Lytecaster 1001H User manual

Lightolier

Lightolier Lytecaster 1001H User manual

Lightolier Lytespan 23F20T4 User manual

Lightolier

Lightolier Lytespan 23F20T4 User manual

Popular Lighting Equipment manuals by other brands

PASCO WA-9897 instruction sheet

PASCO

PASCO WA-9897 instruction sheet

Bowens EQUIPE HEAD Operating instrctions

Bowens

Bowens EQUIPE HEAD Operating instrctions

Lampo IP66 user manual

Lampo

Lampo IP66 user manual

Vision & Control DL30x30-R633/UDC/-a Instructions for use

Vision & Control

Vision & Control DL30x30-R633/UDC/-a Instructions for use

recharge health FlexBeam Instructions for use

recharge health

recharge health FlexBeam Instructions for use

Velleman HQ POWER HQPL10001 user manual

Velleman

Velleman HQ POWER HQPL10001 user manual

Iluminarc Ilumipod 18g2 IP Optic RGB user manual

Iluminarc

Iluminarc Ilumipod 18g2 IP Optic RGB user manual

ACME LED-SC252 user guide

ACME

ACME LED-SC252 user guide

Blizzard Lighting mikrokassette manual

Blizzard Lighting

Blizzard Lighting mikrokassette manual

luminii Matrix Plus MP-DO-DW-22K-60K installation instructions

luminii

luminii Matrix Plus MP-DO-DW-22K-60K installation instructions

Videotec GEKO IRH instruction manual

Videotec

Videotec GEKO IRH instruction manual

DTS XR1200 WASH Fresnel user manual

DTS

DTS XR1200 WASH Fresnel user manual

Party Light & Sound PARTY-PAR-ASTRO user manual

Party Light & Sound

Party Light & Sound PARTY-PAR-ASTRO user manual

Venue Lighting Effects LED PAR64 user manual

Venue Lighting Effects

Venue Lighting Effects LED PAR64 user manual

ETC Sensor IQ DALI Control Option Card installation guide

ETC

ETC Sensor IQ DALI Control Option Card installation guide

EuroLite LED PLL-480 user manual

EuroLite

EuroLite LED PLL-480 user manual

EFFILUX effiLase V3 user manual

EFFILUX

EFFILUX effiLase V3 user manual

luceco TITAN HIGHBAY EMERGENCY Installation & operating instructions

luceco

luceco TITAN HIGHBAY EMERGENCY Installation & operating instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.