manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. luceco
  6. •
  7. Lighting Equipment
  8. •
  9. luceco TITAN HIGHBAY EMERGENCY Manual

luceco TITAN HIGHBAY EMERGENCY Manual

1
3
2
4
TITAN HIGHBAY EMERGENCY
PART CODE: LHBT27B22E12040-01 / LHBT27B22E9040-01 / LHBT27B22E6040-01 /
LHBT33B29E12040-01 / LHBT33B29E9040-01 / LHBT33B29E6040-01
This Luminaire contains a light source of Class <D>
LHBT.VK.09.2022
IP65
RATED
50,000
HOURS
5
WARRANTY
year
standard
8mm EXPANSION SCREW HOLES
CEILING
MONTAGE ET INSTALLATION
• Assurez-vous que le courant électrique soit
coupé avant installation
• Le luminaire peut être utilisé en situation extérieure
ou intérieure
• Voltage AC 220-240V, Fréquence 50/60Hz
• Assurez-vous que le support de l'accessoire peut
correspondre au poids du luminaire
• Pour assurer la durée de vie du luminaire, ne pas installer
le produit autour de vapeur surchauffée et de gaz corrosif
MONTAJE E INSTALACIÓN
• Asegúrese de cortar energía antes de la instalación
• Las lámparas se pueden utilizar en exteriores
o en interiores
• El voltaje es AC 220-240V, la frecuencia es 50 / 60Hz
• Asegúrese de que el soporte de carga del accesorio puede
igualar el peso de la lámpara
• Para garantizar la vida de la lámpara, no instale lámparas
alrededor, o vapor sobrecalentado y gases corrosivos
MONTAGGIO E INSTALLAZIONE
• Assicurarsi che l'alimentazione sia tagliata prima
dell'installazione
• Le lampade possono essere utilizzate all'aperto o in interni
• La tensione è AC 220-240V, la frequenza è 50 / 60Hz
• Assicurarsi che la staffa di ricarica dell'accessorio possa
corrispondere al peso della lampada
• Per garantire la durata della lampada, noninstallare le
lampade in ambienti con vapore surriscaldato e gas corrosivi
ASSEMBLY AND INSTALLATION
• Make sure the power cut-off before installation
• The lamps can be used in outdoor or indoor situation
• Voltage is AC 220-240V, Frecuency is 50/60Hz
• Make sure the load-bearing of accesory can match
the weight of lamp
• To make sure the lifespan of lamps, do not install the
lamps around superheated steam and corrosive gases
ZUSAMMENBAU UND INSTALLATION
• Unterbrechen Sie die Stromversorgung, bevor
Sie mit der Montage beginnen
• Die Leuchte kann im Innen- und Außenbereich verwendet werden
• Für die Verwendung mit einer Netzspannung von 220-240V
AC – 50/60Hz
• Stellen Sie sicher, dass die Belastbarkeit des verwendeten
Monagematerials zum Gewicht der Leuchte passt
• Um sicherzustellen, dass die angegebene Lebensdauer
erreicht wird, setzen Sie die Leuchte weder heißem Dampf
noch ätzenden Gasen aus
EN DE
ES IT
FR
Installation & Operating Instructions
Tech Help Line
UK - 0330 0249 279
Non UK - +44 (0)1952 238 100
Supplied by LUCECO
Stafford Park 1, Telford, Shropshire,
England, TF3 3BD
Visit our website at www.luceco.com
Servicio de asistencia telefónica
UK - 0330 0249 279
Non UK - +34 93 829 55 74
Visite nuestra web en www.luceco.com
(EU) Luceco SE
C/ Bobinadora 1-5
08302 MatarόSpain
7 8
5 6
LHBT.VK.09.2022
0
I
I
0
0
I
I
0
Blue
Brown
Wall Switch
Black
Grey
AC-N
AC-L
EMERGENCY
PACK
Switch Button
Press down the switch button to connect the battery
Press again the switch button to disconnect the battery
6-7WEmergency power 180 minutes
Discharge time
Li-ion >24Hrs
Battery Recharge Time
Operating Temperature: -0°C~+45°C Warranty Years: 2 Years
Emergency Output: >1000lm
30mm
22mm
8mm
Test Button (green light)
Permanently green: No fault and battery is charged
2S 2S 2S 2S 2S 2S 2S
Green light flashing slowly (bright 2S, dark 2S)
No mains and battery is discharged
Green light flashing quickly: Emergency pack fault
Dark:
1.Switch button off
2.Dead battery
3.Cable wiring to battery faulty
Installation & Operating Instructions
Tech Help Line
UK - 0330 0249 279
Non UK - +44 (0)1952 238 100
Supplied by LUCECO
Stafford Park 1, Telford, Shropshire,
England, TF3 3BD
Visit our website at www.luceco.com
Servicio de asistencia telefónica
UK - 0330 0249 279
Non UK - +34 93 829 55 74
Visite nuestra web en www.luceco.com
(EU) Luceco SE
C/ Bobinadora 1-5
08302 MatarόSpain
LHBT.VK.09.2022
ROUTINE TEST RECORD
First Year Second Year Third Year Fourth Year Fifth Year
Month Test Signed Date Signed Date Signed Date Signed Date Signed Date
1 Function
2 Function
3 Function
4 Function
5 Function
6 Function
7 Function
8 Function
9 Function
10 Function
11 Function
12 Function
LHBT Emergency Lighting
Titan Highbay Emergency
RECOMMENDED
ROUTINE PROCEDURE
The following test isdesigned to
ensure the continued protection
of your premises and occupants.
Because of the possibility of a
failure of the normal lighting supply
occurring shortly after a period of
testing, all tests should, whenever
possible, be undertaken at timesof
least risk, e.g. during daylight hours.
ONCE A DAY
Visual inspection of battery
charge LED.
ONCE A MONTH
Each unit should be eneregized
from its battery for about 30
seconds by simulation of a failure
of the normal lighting supply to
ensure the lamp operates in the
emergency condition.
TWICE A YEAR
Each unit should be energized
from it’s battery for a continuous
period of at least one hour.
AFTER THREE YEARS
& EACH SUBSEQUENT YEAR
All units with specifieddurations
in excess of 1 hour should be
energized for their full rating period.
Installation & Operating Instructions
Tech Help Line
UK - 0330 0249 279
Non UK - +44 (0)1952 238 100
Supplied by LUCECO
Stafford Park 1, Telford, Shropshire,
England, TF3 3BD
Visit our website at www.luceco.com
Servicio de asistencia telefónica
UK - 0330 0249 279
Non UK - +34 93 829 55 74
Visite nuestra web en www.luceco.com
(EU) Luceco SE
C/ Bobinadora 1-5
08302 MatarόSpain

This manual suits for next models

6

Other luceco Lighting Equipment manuals

luceco UTF6WD2W Manual

luceco

luceco UTF6WD2W Manual

luceco UTF6WCCT Manual

luceco

luceco UTF6WCCT Manual

luceco LED3EP80 Manual

luceco

luceco LED3EP80 Manual

luceco LBM290W11E40 Manual

luceco

luceco LBM290W11E40 Manual

luceco Ceres Series Manual

luceco

luceco Ceres Series Manual

luceco LAC12P22S40 Manual

luceco

luceco LAC12P22S40 Manual

luceco LXB12W Series Manual

luceco

luceco LXB12W Series Manual

luceco LED Fire Rated Downlight Manual

luceco

luceco LED Fire Rated Downlight Manual

Popular Lighting Equipment manuals by other brands

Future light PHW-250 Pro-Head-Wash user manual

Future light

Future light PHW-250 Pro-Head-Wash user manual

IKEA tradfri manual

IKEA

IKEA tradfri manual

Champlain ACM-197 manual

Champlain

Champlain ACM-197 manual

Command Light SHADOW Series user guide

Command Light

Command Light SHADOW Series user guide

hernest H300017 user manual

hernest

hernest H300017 user manual

Eurofase Lighting 34125 instruction manual

Eurofase Lighting

Eurofase Lighting 34125 instruction manual

Lumineux Avon PRO 4CCT installation instructions

Lumineux

Lumineux Avon PRO 4CCT installation instructions

Zumtobel SUPER-P Series Instructions for mounting

Zumtobel

Zumtobel SUPER-P Series Instructions for mounting

Ryobi R18ALF manual

Ryobi

Ryobi R18ALF manual

Avanto Lifestyle CHEST LIGHT PRO instructions

Avanto Lifestyle

Avanto Lifestyle CHEST LIGHT PRO instructions

Soundoff Signal MPower EMPR10004-WW instructions

Soundoff Signal

Soundoff Signal MPower EMPR10004-WW instructions

LED World FA-SV4713-108-24-RGB Important instructions

LED World

LED World FA-SV4713-108-24-RGB Important instructions

Ikan LSC-001 quick start guide

Ikan

Ikan LSC-001 quick start guide

Vision & Control LDLF30x420-IR850/24V/-a Instructions for use

Vision & Control

Vision & Control LDLF30x420-IR850/24V/-a Instructions for use

Lightolier XA432 specification

Lightolier

Lightolier XA432 specification

Heitronic 37234 manual

Heitronic

Heitronic 37234 manual

City Theatrical AUTOYOKE user manual

City Theatrical

City Theatrical AUTOYOKE user manual

Maretti SALERNO DOWNLIGHTER 10.6370 Series instruction manual

Maretti

Maretti SALERNO DOWNLIGHTER 10.6370 Series instruction manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.