Lightsafe_ERLEDBT_Instructions_Rev01
Automatic Self Test Function
The luminaire has an integral automatic self-test function.
When the luminaire is connected to a 230v AC supply the luminaire will perform an automatic test, monthly
and annually. The first monthly test will be performed approximately between 16
th
to 30
th
day and the
annual test will be between 200
th
to 360
th
day from initial power on.
After the first annual test, the test routine will then be scheduled for every 30 days and every 360 day for the
monthly and annual tests. The luminaire will retain the testing schedule for approximately 7 days without a
230v AC supply (the internal battery still has to be connected).
Automatic Daily Test
The luminaire chec s daily if the battery is connected and that AC mains supply is present, if both are present
the GREEN LED will be illuminated. If the battery is not connected or there is an issue with the battery the
LED will flash Red once every three seconds. If there is no 230v AC supply present the LED indicator will be
extinguished and the luminaire will go in to emergency mode.
Monthly /Annual Test
The luminaire performs an automatic 10 minutes duration self-test every month and an annual test for the
full 3 hours duration. During the test the LED will be flashing RED quic ly to indicate the fitting is in test for
the duration of the test, if the test has been completed and satisfactorily then the LED will return to a
constant Green state.
If during the test there is an issue with the light output, then the LED will flash Red twice every three seconds.
If fitting does not complete the required emergency duration then the LED will flash Red three times every
three seconds.
Manual Test
The luminaire has an integral test button on the PCB which has two functions;
1. When the button is pressed once, the schedule of self-test will be reset (i.e. from the 1
st
day
installed).
2. When the button is pressed for three seconds, the fitting will enter a self-test mode for 5 minutes
with the same LED color indication as the monthly/annual test (red flashing quic ly).
LED Indicator Status
Green LED On: AC mains supply and battery connected
LED Off: No AC supply present
Red Flash once every 3 seconds: Issue with the battery during the daily test
Red Flash very quic ly: Luminaire in manual/monthly/annual test mode
Red Flash twice every 3 seconds: Fitting failed test - Issue with the light output during auto-test
Red Flash three every 3 seconds: Fitting failed test – the battery duration was not achieved during auto-test
Failed Test / Reset: After a failed test and the fault has been rectified, the test button will
need to be pressed for 3 seconds to activate a self-test for 5 minutes or
remove the 230v AC supply to reset the fault and LED indicator status
bac to green.
Maintenance
Repairs should only be carried out by suitably qualified person