Lincoln Electric SF4200 User manual

SF4200 Stationary Fan
Register your machine:
www.lincolnelectric.com/register
Authorized Service and Distributor Locator:
www.lincolnelectric.com/locator
IM10410 | Issue Date Jun-19
© Lincoln Global, Inc. All Rights Reserved.
For use with machines having Code Numbers:
K1656-4
Save for future reference
Date Purchased
Code: (ex: 10859)
Serial: (ex: U1060512345)
Operator’s Manual

THANK YOU FOR SELECTING
A QUALITY PRODUCT BY
LINCOLN ELECTRIC.
PLEASE EXAMINE CARTON AND EQUIPMENT FOR
DAMAGE IMMEDIATELY
When this equipment is shipped, title passes to the purchaser
upon receipt by the carrier. Consequently, claims for material
damaged in shipment must be made by the purchaser against the
transportation company at the time the shipment is received.
SAFETY DEPENDS ON YOU
Lincoln arc welding and cutting equipment is designed and built
with safety in mind. However, your overall safety can be increased
by proper installation ... and thoughtful operation on your part.
DO NOT INSTALL, OPERATE OR REPAIR THIS EQUIPMENT
WITHOUT READING THIS MANUAL AND THE SAFETY
PRECAUTIONS CONTAINED THROUGHOUT. And, most importantly,
think before you act and be careful.
This statement appears where the information must be followed
exactly to avoid serious personal injury or loss of life.
This statement appears where the information must be followed
to avoid minor personal injury or damage to this equipment.
KEEP YOUR HEAD OUT OF THE FUMES.
DON’T get too close to the arc.
Use corrective lenses if necessary
to stay a reasonable distance
away from the arc.
READ and obey the Safety Data
Sheet (SDS) and the warning label
that appears on all containers of
welding materials.
USE ENOUGH VENTILATION or
exhaust at the arc, or both, to
keep the fumes and gases from
your breathing zone and the general area.
IN A LARGE ROOM OR OUTDOORS, natural ventilation may be
adequate if you keep your head out of the fumes (See below).
USE NATURAL DRAFTS or fans to keep the fumes away
from your face.
If you develop unusual symptoms, see your supervisor.
Perhaps the welding atmosphere and ventilation system
should be checked.
WEAR CORRECT EYE, EAR &
BODY PROTECTION
PROTECT your eyes and face with welding helmet
properly fitted and with proper grade of filter plate
(See ANSI Z49.1).
PROTECT your body from welding spatter and arc
flash with protective clothing including woolen
clothing, flame-proof apron and gloves, leather
leggings, and high boots.
PROTECT others from splatter, flash, and glare
with protective screens or barriers.
IN SOME AREAS, protection from noise may be appropriate.
BE SURE protective equipment is in good condition.
Also, wear safety glasses in work area
AT ALL TIMES.
SPECIAL SITUATIONS
DO NOT WELD OR CUT containers or materials which previously
had been in contact with hazardous substances unless they are
properly cleaned. This is extremely dangerous.
DO NOT WELD OR CUT painted or plated parts unless special
precautions with ventilation have been taken. They can release
highly toxic fumes or gases.
Additional precautionary measures
PROTECT compressed gas cylinders from excessive heat,
mechanical shocks, and arcs; fasten cylinders so they cannot fall.
BE SURE cylinders are never grounded or part of an
electrical circuit.
REMOVE all potential fire hazards from welding area.
ALWAYS HAVE FIRE FIGHTING EQUIPMENT READY FOR
IMMEDIATE USE AND KNOW HOW TO USE IT.
WARNING
CAUTION
Safety 01 of 04 - 5/16/2018

SECTION A:
WARNINGS
CALIFORNIA PROPOSITION 65 WARNINGS
WARNING: Breathing diesel engine exhaust
exposes you to chemicals known to the State
of California to cause cancer and birth defects,
or other reproductive harm.
• Always start and operate the engine in a
well-ventilated area.
• If in an exposed area, vent the exhaust to the outside.
• Do not modify or tamper with the exhaust system.
• Do not idle the engine except as necessary.
For more information go to
www.P65 warnings.ca.gov/diesel
WARNING: This product, when used for welding or
cutting, produces fumes or gases which contain
chemicals known to the State of California to cause
birth defects and, in some cases, cancer. (California
Health & Safety Code § 25249.5 et seq.)
WARNING: Cancer and Reproductive Harm
www.P65warnings.ca.gov
ARC WELDING CAN BE HAZARDOUS. PROTECT
YOURSELF AND OTHERS FROM POSSIBLE SERIOUS
INJURY OR DEATH. KEEP CHILDREN AWAY.
PACEMAKER WEARERS SHOULD CONSULT WITH
THEIR DOCTOR BEFORE OPERATING.
Read and understand the following safety highlights. For
additional safety information, it is strongly recommended
that you purchase a copy of “Safety in Welding & Cutting -
ANSI Standard Z49.1” from the American Welding Society,
P.O. Box 351040, Miami, Florida 33135 or CSA Standard
W117.2-1974. A Free copy of “Arc Welding Safety” booklet
E205 is available from the Lincoln Electric Company,
22801 St. Clair Avenue, Cleveland, Ohio 44117-1199.
BE SURE THAT ALL INSTALLATION, OPERATION,
MAINTENANCE AND REPAIR PROCEDURES ARE
PERFORMED ONLY BY QUALIFIED INDIVIDUALS.
FOR ENGINE POWERED
EQUIPMENT.
1.a. Turn the engine off before troubleshooting
and maintenance work unless the
maintenance work requires it to be running.
1.b. Operate engines in open, well-ventilated areas or vent the engine
exhaust fumes outdoors.
1.c. Do not add the fuel near an open flame welding
arc or when the engine is running. Stop the
engine and allow it to cool before refueling to
prevent spilled fuel from vaporizing on contact
with hot engine parts and igniting. Do not spill fuel when filling
tank. If fuel is spilled, wipe it up and do not start engine until
fumes have been eliminated.
1.d. Keep all equipment safety guards, covers
and devices in position and in good repair.
Keep hands, hair, clothing and tools away
from V-belts, gears, fans and all other
moving parts when starting, operating or
repairing equipment.
1.e. In some cases it may be necessary to remove safety guards to
perform required maintenance. Remove guards only when
necessary and replace them when the maintenance requiring
their removal is complete. Always use the greatest care when
working near moving parts.
1.f. Do not put your hands near the engine fan. Do not attempt to
override the governor or idler by pushing on the throttle control
rods while the engine is running.
1.g. To prevent accidentally starting gasoline engines while turning
the engine or welding generator during maintenance work,
disconnect the spark plug wires, distributor cap or magneto wire
as appropriate.
1.h. To avoid scalding, do not remove the radiator
pressure cap when the engine is hot.
ELECTRIC AND
MAGNETIC FIELDS MAY
BE DANGEROUS
2.a. Electric current flowing through any conductor
causes localized Electric and Magnetic Fields (EMF).
Welding current creates EMF fields around welding cables
and welding machines
2.b. EMF fields may interfere with some pacemakers, and
welders having a pacemaker should consult their physician
before welding.
2.c. Exposure to EMF fields in welding may have other health effects
which are now not known.
2.d. All welders should use the following procedures in order to
minimize exposure to EMF fields from the welding circuit:
2.d.1. Route the electrode and work cables together - Secure
them with tape when possible.
2.d.2. Never coil the electrode lead around your body.
2.d.3. Do not place your body between the electrode and work
cables. If the electrode cable is on your right side, the
work cable should also be on your right side.
2.d.4. Connect the work cable to the workpiece as close as pos-
sible to the area being welded.
2.d.5. Do not work next to welding power source.
SAFETY
Safety 02 of 04 - 5/16/2018

ELECTRIC SHOCK
CAN KILL.
3.a. The electrode and work (or ground) circuits are
electrically “hot” when the welder is on. Do
not touch these “hot” parts with your bare skin or wet clothing.
Wear dry, hole-free gloves to insulate hands.
3.b. Insulate yourself from work and ground using dry insulation.
Make certain the insulation is large enough to cover your full area
of physical contact with work and ground.
In addition to the normal safety precautions, if
welding must be performed under electrically
hazardous conditions (in damp locations or while
wearing wet clothing; on metal structures such as
floors, gratings or scaffolds; when in cramped
positions such as sitting, kneeling or lying, if there
is a high risk of unavoidable or accidental contact
with the workpiece or ground) use the following
equipment:
• Semiautomatic DC Constant Voltage (Wire) Welder.
• DC Manual (Stick) Welder.
• AC Welder with Reduced Voltage Control.
3.c. In semiautomatic or automatic wire welding, the electrode,
electrode reel, welding head, nozzle or semiautomatic welding
gun are also electrically “hot”.
3.d. Always be sure the work cable makes a good electrical
connection with the metal being welded. The connection should
be as close as possible to the area being welded.
3.e. Ground the work or metal to be welded to a good electrical (earth)
ground.
3.f. Maintain the electrode holder, work clamp, welding cable and
welding machine in good, safe operating condition. Replace
damaged insulation.
3.g. Never dip the electrode in water for cooling.
3.h. Never simultaneously touch electrically “hot” parts of electrode
holders connected to two welders because voltage
between the
two can be the total of the open circuit voltage of both
welders.
3.i. When working above floor level, use a safety belt to protect
yourself from a fall should you get a shock.
3.j. Also see Items 6.c. and 8.
ARC RAYS CAN BURN.
4.a. Use a shield with the proper filter and cover plates to protect your
eyes from sparks and the rays of the arc when welding or
observing open arc welding. Headshield and filter lens should
conform to ANSI Z87. I standards.
4.b. Use suitable clothing made from durable flame-resistant material
to protect your skin and that of your helpers from the arc rays.
4.c. Protect other nearby personnel with suitable, non-flammable
screening and/or warn them not to watch the arc nor expose
themselves to the arc rays or to hot spatter or metal.
FUMES AND GASES
CAN BE DANGEROUS.
5.a. Welding may produce fumes and gases
hazardous to health. Avoid breathing these
fumes and gases. When welding, keep your head out of the fume.
Use enough ventilation and/or exhaust at the arc to keep fumes
and gases away from the breathing zone. When welding
hardfacing (see instructions on container or SDS)
or on lead or cadmium plated steel and other
metals or coatings which produce highly toxic
fumes, keep exposure as low as possible and
within applicable OSHA PEL and ACGIH TLV limits
using local exhaust or mechanical ventilation
unless exposure assessments indicate otherwise.
In confined spaces or in some circumstances,
outdoors, a respirator may also be required.
Additional precautions are also required when
welding
on galvanized steel.
5. b. The operation of welding fume control equipment is affected by
various factors including proper use and positioning of the
equipment, maintenance of the equipment and the specific
welding procedure and application involved. Worker exposure
level should be checked upon installation and periodically
thereafter to be certain it is within applicable OSHA PEL and
ACGIH TLV limits.
5.c. Do not weld in locations near chlorinated hydrocarbon vapors
coming from degreasing, cleaning or spraying operations. The
heat and rays of the arc can react with solvent vapors to form
phosgene, a highly toxic gas, and other irritating products.
5.d. Shielding gases used for arc welding can displace air and
cause
injury or death. Always use enough ventilation, especially in
confined areas, to insure breathing air is safe.
5.e. Read and understand the manufacturer’s instructions for this
equipment and the consumables to be used, including the
Safety Data Sheet (SDS) and follow your employer’s safety
practices. SDS forms are available from your welding
distributor or from the manufacturer.
5.f. Also see item 1.b.
SAFETY
Safety 03 of 04 - 5/16/2018

WELDING AND CUTTING
SPARKS CAN CAUSE
FIRE OR EXPLOSION.
6.a. Remove fire hazards from the welding area. If
this is not possible, cover them to prevent the welding sparks
from starting a fire. Remember that welding sparks and hot
materials from welding can easily go through small cracks and
openings to adjacent areas. Avoid welding near hydraulic lines.
Have a fire extinguisher readily available.
6.b. Where compressed gases are to be used at the job site, special
precautions should be used to prevent hazardous situations.
Refer to “Safety in Welding and Cutting” (ANSI Standard Z49.1)
and the operating information for the equipment being used.
6.c. When not welding, make certain no part of the electrode circuit is
touching the work or ground. Accidental contact can cause
overheating and create a fire hazard.
6.d. Do not heat, cut or weld tanks, drums or containers until the
proper steps have been taken to insure that such procedures
will not cause flammable or toxic vapors from substances inside.
They can cause an explosion even though they have been
“cleaned”. For information, purchase “Recommended Safe
Practices for the Preparation for Welding and Cutting of
Containers and Piping That Have Held Hazardous Substances”,
AWS F4.1 from the American Welding Society
(see address above).
6.e. Vent hollow castings or containers before heating, cutting or
welding. They may explode.
6.f. Sparks and spatter are thrown from the welding arc. Wear oil free
protective garments such as leather gloves, heavy shirt, cuffless
trousers, high shoes and a cap over your hair. Wear ear plugs
when welding out of position or in confined places. Always wear
safety glasses with side shields when in a welding area.
6.g. Connect the work cable to the work as close to the welding area
as practical. Work cables connected to the building framework or
other locations away from the welding area increase the
possibility of the welding current passing through lifting chains,
crane cables or other alternate circuits. This can create fire
hazards or overheat lifting chains or cables until they fail.
6.h. Also see item 1.c.
6.I. Read and follow NFPA 51B “Standard for Fire Prevention During
Welding, Cutting and Other Hot Work”, available from NFPA, 1
Batterymarch Park, PO box 9101, Quincy, MA 022690-9101.
6.j. Do not use a welding power source for pipe thawing.
CYLINDER MAY EXPLODE IF
DAMAGED.
7.a. Use only compressed gas cylinders containing
the correct shielding gas for the process used
and properly operating regulators designed for
the gas and pressure used. All hoses, fittings,
etc. should be suitable for the application and
maintained in good condition.
7.b. Always keep cylinders in an upright position securely chained to
an undercarriage or fixed support.
7.c. Cylinders should be located:
• Away from areas where they may be struck or subjected
to physical damage.
• A safe distance from arc welding or cutting operations
and any other source of heat, sparks, or flame.
7.d. Never allow the electrode, electrode holder or any other
electrically “hot” parts to touch a cylinder.
7.e. Keep your head and face away from the cylinder valve outlet
when opening the cylinder valve.
7.f. Valve protection caps should always be in place and hand tight
except when the cylinder is in use or connected for use.
7.g. Read and follow the instructions on compressed gas cylinders,
associated equipment, and CGA publication P-l, “Precautions for
Safe Handling of Compressed Gases in Cylinders,” available from
the Compressed Gas Association, 14501 George Carter Way
Chantilly, VA 20151.
FOR ELECTRICALLY
POWERED EQUIPMENT.
8.a. Turn off input power using the disconnect
switch at the fuse box before working on
the equipment.
8.b. Install equipment in accordance with the U.S. National Electrical
Code, all local codes and the manufacturer’s recommendations.
8.c. Ground the equipment in accordance with the U.S. National
Electrical Code and the manufacturer’s recommendations.
Refer to
http://www.lincolnelectric.com/safety
for additional safety information.
SAFETY
Safety 04 of 04 - 5/16/2018

TABLE OF CONTENTS
SF4200 STATIONARY FAN
TABLE OF CONTENTS
Page
General Description.......................................................................................................1
Required Accessories for Input Power........................................................................1
Technical Specifications...............................................................................................1
Installation......................................................................................................................2
Operation Instructions ..................................................................................................4
Routine Maintenance.....................................................................................................4
Troubleshooting Guide .................................................................................................5
Wiring Diagrams ............................................................................................................6
PARTS LIST ...............................................................................................................PARTS.LINCOLNELECTRIC.COM
CONTENT/DETAILS MAY BE CHANGED OR UPDATED WITHOUT NOTICE. FOR MOST CURRENT INSTRUCTION MANUALS, GO
TO PARTS.LINCOLNELECTRIC.COM.....................................................................................................

INSTALLATIONSF4200 STATIONARY FAN
GENERAL DESCRIPTION
The K1656-4 SF4200 Stationary Fan provides low vacuum, high
volume airflow for fume extraction applications. It is intended for use
with a LFA 3.1 or LFA 4.1 flexible extraction arm mounted on an
Extension Crane (7 or 14 ft.).
Extracted welding fume can be filtered through a wall-mounted
filtration unit such as the Statiflex®200-M or Statiflex 400-MS.
Operation of the SF4200 Stationary Fan is controlled using the
Starter/Overload Switch or the Lamp Kit with Arc Sensor. The
Starter/Overload Switch allows the operator to manually turn the
SF4200 Stationary Fan on and off and protects the fan motor against
overcurrent. The Lamp Kit with Arc Sensor includes a lamp for
illuminating the work piece, hood-mounted on/off switches for the
lamp and extraction fan, motor overload protection, and an arc sensor
for automatic operation of the extraction fan.
REquiREd ACCESSORiES:
When used with a Statiflex 200-M Filtration Unit:
K1494-10 Starter/Overload Switch
OR
K1669-10 Lamp Kit with Arc Sensor
When used with a Statiflex 400-MS Filtration
Unit:
K1669-10 Lamp Kit with Arc Sensor
TECHNICAL
SPECIFICATIONS
NOTE: Technical specifications are subject to change without prior notice.
Specifications and guarantees are valid only when specified spare parts
and filters are used.
FIGURE 1 – DIMENSIONS
6.69 in.
(170.00mm)
0.28 in.
(7.00mm)
4.59 in.
(116.50mm)
12.99 in.
(330.00mm)
11.81 in.
(300.00mm)
5.98 in.
(152.00mm)
15.16 in.
(385.00 mm)
25.22 in.
(640.50mm)
GENERAL
PRODUCT NUMBER K1656-4
INPUT POWER 230V, 3Ph, 60Hz
RATED CURRENT DRAW 6.8A
HORSEPOWER 2HP (1.5 kW)
SOUND LEVEL 72 dB(A)
WEIGHT 119 lbs. (54 kg)
AMBIENT CONDITIONS
MINIMUM TEMPERATURE 41ºF (5ºC)
MAXIMUM TEMPERATURE 140ºF (60ºC)
MAXIMUM RELATIVE HUMIDITY 80%
1

2
INSTALLATIONSF4200 STATIONARY FAN
INSTALLATION
For information on installation of fume
extraction arm(s) and filtration unit, refer to the
corresponding manuals.
Use adequate mounting hardware for
installing the SF4200, corresponding with the
type of wall. Be aware, the weight of the unit
when unpacked is approx. 119 lbs (54 kg).
NOTE: In the standard configuration of the Statiflex 200-M(/HE)
Single Arm system, the filter unit is positioned on the right side of
the fan. However, it may be mounted on either side, as long as the
connection hose reaches from the outlet of the fan to the inlet of
the Statiflex 200-M(/HE).
The installer is responsible for following Federal, State and
Local safety codes and regulations.
Before drilling, verify locations of existing gas, water, or
electrical conduits.
ELECTRIC SHOCK can kill.
• Do not touch electrically live parts such as
internal wiring.
• Turn the input power off at the fuse box
before working on this equipment.
• Have a qualified person install and service this
equipment.
MOVING PARTS can injure.
• Do not operate with covers open or filter
removed.
• Keep away from moving parts.
Only qualified personnel should install, use or
service this equipment.
WARNING
ATTENTION

3
INSTALLATIONSF4200 STATIONARY FAN
COmpONENTS
SF4200 unit consists of the following main components
(see Figure 2):
A. Fan
B. Inlet
C. Outlet
D. Screws for mounting inlet
and outlet to fan
iNSTALLATiON STEpS:
1. Mount the SF4200 unit to the wall. Position the unit considering
the location and space requirements for the filtration unit and
extraction arm. Use appropriate screws / anchor bolts to secure
the unit based on the type of wall. (Hardware not included with
SF4200 unit)
2. Mount the inlet and outlet to SF4200 with the screws provided
3. Slide the 8 in. diameter connection hose over the outlet and
secure with 8 in. diameter hose clamp (items supplied with
Statiflex Unit)
4. Route lamp / arc sensor cable (refer the lamp / arc sensor
manual) through the inlet part and out through the grommet on
the inlet part.
5. Slide the 8 in. diameter connection hose over the inlet and
secure with 8 in. diameter hose clamp (items supplied with
extension crane / extraction arm)
6. Complete the required electrical connections to the fan motor
and control(s) based on the wiring diagram. Refer to the last
section of the manual.
C
A
B
Statiex 200-M8 in. diameter
connection hose
(supplied with
Statiex unit)
Extension Crane
FIGURE 2

4
OPERATION
OPERATING
INSTRUCTIONS
When used with a wall-mounted starter/overload switch:
• Press the green button on the starter/overload switch
to turn on the SF4200 fan.
• Position hood of extraction arm within 10-15 inches
(250-400 mm) of the arc.
• Press the red button to turn off the SF4200 fan.
When used with a Lamp/Arc Sensor Kit:
Manual fan operation-
• The 0/1 switch on the extraction arm hood manually
operates the SF4200 Fan. Move the switch to the 1 (on)
position to turn on the fan.
• Position hood of extraction arm within 10-15 inches
(250-400 mm) of the arc.
• Move the switch to the 0 (off) position to turn off the
SF4200 fan.
Automatic fan operation-
• Leave the 0/1 switch in the 0 (off) position.
• Position hood of extraction arm within 10-15 inches
(250-400 mm) of the arc.
• The arc sensor will automatically switch the fan on
when it senses an arc.
• When the arc is extinguished, the fan will run for
approximately 50 seconds before turning off.
• The switch on the hood with a lamp symbol operates
the work lamp in the hood. It operates independently of
the arc sensor.
ROUTINE
MAINTENANCE
Every 12 months, have a qualified technician check the blower fan
and housing for encrusted particles and clean if necessary. Check the
sealing material of the extraction fan and replace if necessary.
Routine Maintenance for other components in the system such as
extraction arms, extension cranes, and filtration units is provided in
the manuals for those components.
SF4200 STATIONARY FAN

5
TROUBLESHOOTING
SF4200 STATIONARY FAN
If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your
Lincoln Authorized Service Facility for technical troubleshooting assistance before you proceed.
WWW.LINCOLNELECTRIC.COM/LOCATOR
Service and Repair should only be performed by Lincoln Electric Factory Trained Personnel. Unauthorized repairs performed on
this equipment may result in danger to the technician and machine operator and will invalidate your factory warranty. For your
safety and to avoid ELECTRICAL SHOCK, please observe all safety notes and precautions detailed throughout this manual.
PROBLEMS / SYMPTOM(S) POSSIBLE CAUSE(S) RECOMMENDED COURSE(S) OF ACTION
MOTOR DOES NOT START. No input power. Verify 230VAC/60Hz, 3ph input power at the fan
Input cord maybe damaged. Check the integrity of the input cord
Loose Contacts Check the contacts.
Starter/overload switch
damaged or defective.
Contact Lincoln Authorized Service Facility
Motor maybe damaged or
defective.
Contact Lincoln Authorized Service Facility
MOTOR HUMS, BUT NO
SUCTION.
Motor capacitor defective or not
connected.
Contact Lincoln Authorized Service Facility
MOTOR STOPS
AUTOMATICALLY
Motor overload protection
activated.
Let the machine cool down for a few minutes.
Motor defective or damaged Contact Lincoln Authorized Service Facility
POOR SUCTION. Leakage. Check hose connections and integrity.
Outlet grid blocked. Remove obstructions from outlet grid.
Air path in arm blocked. Remove obstructions from arm.
Filter blocked (check
Maintenance Indicator).
Replace filter.
Spark arrester blocked. Clean the spark arrester.
Blower fan blocked. Clean excess fume or spatter from fan.
Fan seal damaged. Check or replace sealing material of fan.
DUST OR SMOKE COMING OUT
OF OUTLET.
Filter damaged, or not seated
correctly.
Replace the filter or reseat it.
VIBRATIONS IN THE FAN. Imbalance in the fan. Clean excess dirt from fan.
TROUBLESHOOTING GUIDE

6
DIAGRAMS
SF4200 STATIONARY FAN
WIRING DIAGRAM FOR SF4200 FAN WITH K1494-10 STARTER/OVERLOAD SWITCH
Sales and Service through Subsidiaries and Distributors Worldwide
Cleveland, Ohio 44117-1199 U.S.A.
THE LINCOLN ELECTRIC COMPANY
World's Leader in Welding and Cutting Products
FC7900020910PRINT
B
1
2
ITEM DESCRIPTION QTY
1MANUAL STARTER SWITCH 1
2OVERLOAD HEATER 3
MOTOR STARTER (HEAVY DUTY) SF4200, 230V, 3~, 60Hz, 2HP
3 CORE 16AWG CABLE
3 CORE MIN 16AWG CABLE
FAN MOTOR
2HP
230V 3
ø
60 Hz
MOTOR
W1
L1 L2 L3
START
STOP
46 46 46
WWW
T1 T2 T3
230V 60 Hz 3
ø
I/P POWER
W3
W2V2
U2
U3
U1
V3
V1
NOTES:
N A. USE MOTOR TERMINAL CONFIGURATION PRINTED ON THE
NAMEPLATE BASED ON INPUT VOLTAGE
N B. ENSURE RIGHT FAN ROTATION DIRECTION AS MAKE ON
THE FAN BY SWAPPING ANY TWO-PHASE LEADS.
N C. FOLLOW NATIONAL AND/OR LOCAL ELECTRICAL CODES/STANDARDS
FOR CONNECTING MOTOR WIRING INCLUDING GROUND
N D. DISCONNECTING MEANS AND BRANCH CIRCUIT PROTECTION SHALL BE
PROVIDED BY THE INSTALLER

7
DIAGRAMS
SF4200 STATIONARY FAN
Sales and Service through Subsidiaries and Distributors Worldwide
Cleveland, Ohio 44117-1199 U.S.A.
THE LINCOLN ELECTRIC COMPANY
World's Leader in Welding and Cutting Products
S31225-22PRINT
B
NOTES:
N A. MOUNTING ON DIN RAIL
N B. FIELD WIRING FOR POWER CIRCUIT SHALL USE
UL RATED 4C MIN 16AWG CABLE WITH OUTER DIA
BETWEEN 0.27 TO 0.51 (7MM TO 13MM)
N C. 201, 202, 208 & GND SHALL BE BLACK AND 14AWG
N D. 207, 204, 209, 203 SHALL BE MIN 18AWG
N E. USE MOTOR TERMINAL CONFIGURATION AS PER INDICATED
ON THE MOTOR NAMEPLATE BASED ON INPUT VOLTAGE
N F. ENSURE RIGHT FAN ROTATION DIRECTION AS MAKE
ON THE FAN BY SWAPPING ANY TWO PHASE LEADS
230 VAC, 3~
230V
2A
1A1A CC
OL
A2 FAN ON/OFF
N
24V
FAN MANUAL
ON/OFF
ARC
SENSOR
FLOOD
LIGHT
C
OL
SET TO 6.3A
FAN
MOTOR
AC
S1
S2
S3
GND
SCHEMATICS
B
24V 24V
6
10
2
1345
CONTROL BOX
ACONNECT GND
TO TERMINAL
B
204B
L1 L2 L3 A1
13
CONTACTOR
OVERLOAD
RELAY
SET AT 6.3A
T1 T2 T3 A2
TRANSFORMER
N24V
2A
G
WH
BK RD
ARC SENSOR
WH
BL
RD
BK
BK
WH
YE/GN
MOTOR
GND
FAN MOTOR
S1
S2
S3
2HP, 230VAC, 3~, 60Hz
201
202
202
201
207
206
NA
204A 203
209 203
207
204A
204B
WIRING
4 CORE 16AWG CABLE
3 CORE
20AWG
CABLE
C
GND
209
ABC
BK RD
T1
123 4 5
610
NB
NB
DISCONNECTING MEANS AND BRANCH CIRCUIT
PROTECTION SHALL BE PROVIDED BY THE INSTALLER
208
BK BK
BK
BK
BK
WH
RD
RD
U1
V1
W1
U3
V3
W3
U2
V2
W2
MOTOR LAMP CONTROLLER SF4200, 230V, 3~, 60Hz, 2HP
NE
WIRING DIAGRAM FOR SF4200 FAN WITH MOTOR LAMP CONTROLLER

i
L - - - - - - -
Ps
--------------- ____
_____
_____
____
3
4
90
80
0
Flow rate:
Rpm limits
Conditions
[m]
20 [0C]
1,204 kg/m
--------------- ____
_____
_____
____
9
C
M
In(
G)
DIAGRAMS
SF4200 STATIONARY FAN

THIS PAGE INTENTIONALLY LEFT BLANK.

THIS PAGE INTENTIONALLY LEFT BLANK.

THIS PAGE INTENTIONALLY LEFT BLANK.

WARNIN
AVISO DE
PRECAUCION
ATTENTION
WARNUN
ATENÇÃO
Spanish
French
erman
Portuguese
Japanese
Chinese
Korean
Arabic
READ AND UNDERSTAND THE MANUFACTURER’S INSTRUCTION FOR THIS EQUIPMENT AND THE CONSUMABLES TO BE
USED AND FOLLOW OUR EMPLO ER’S SAFET PRACTICES.
SE RECOMIENDA LEER ENTENDER LAS INSTRUCCIONES DEL FABRICANTE PARA EL USO DE ESTE EQUIPO LOS
CONSUMIBLES QUE VA A UTILIZAR, SIGA LAS MEDIDAS DE SEGURIDAD DE SU SUPERVISOR.
LISEZ ET COMPRENEZ LES INSTRUCTIONS DU FABRICANT EN CE QUI REGARDE CET EQUIPMENT ET LES PRODUITS A
ETRE EMPLO ES ET SUIVEZ LES PROCEDURES DE SECURITE DE VOTRE EMPLO EUR.
LESEN SIE UND BEFOLGEN SIE DIE BETRIEBSANLEITUNG DER ANLAGE UND DEN ELEKTRODENEINSATZ DES HER-
STELLERS. DIE UNFALLVERHÜTUNGSVORSCHRIFTEN DES ARBEITGEBERS SIND EBENFALLS ZU BEACHTEN.
lDo not touch electrically live parts or
electrode with skin or wet clothing.
l Insulate yourself from work and
ground.
lNo toque las partes o los electrodos
bajo carga con la piel o ropa moja-
da.
l Aislese del trabajo y de la tierra.
l Ne laissez ni la peau ni des vête-
ments mouillés entrer en contact
avec des pièces sous tension.
l Isolez-vous du travail et de la terre.
l Berühren Sie keine stromführenden
Teile oder Elektroden mit Ihrem
Körper oder feuchter Kleidung!
l Isolieren Sie sich von den
Elektroden und dem Erdboden!
l Não toque partes elétricas e elec-
trodos com a pele ou roupa molha-
da.
l Isole-se da peça e terra.
lKeep flammable materials away.
l Mantenga el material combustible
fuera del área de trabajo.
l Gardez à l’écart de tout matériel
inflammable.
l Entfernen Sie brennbarres Material!
l Mantenha inflamáveis bem guarda-
dos.
lWear eye, ear and body protection.
l Protéjase los ojos, los oídos y el
cuerpo.
l Protégez vos yeux, vos oreilles et
votre corps.
l Tragen Sie Augen-, Ohren- und Kör-
perschutz!
l Use proteção para a vista, ouvido e
corpo.

WARNIN
AVISO DE
PRECAUCION
ATTENTION
WARNUN
ATENÇÃO
Spanish
French
erman
Portuguese
Japanese
Chinese
Korean
Arabic
LEIA E COMPREENDA AS INSTRUÇÕES DO FABRICANTE PARA ESTE EQUIPAMENTO E AS PARTES DE USO, E SIGA AS
PRÁTICAS DE SEGURANÇA DO EMPREGADOR.
l Keep your head out of fumes.
l Use ventilation or exhaust to
remove fumes from breathing zone.
l Los humos fuera de la zona de res-
piración.
l Mantenga la cabeza fuera de los
humos. Utilice ventilación o
aspiración para gases.
l Gardez la tête à l’écart des fumées.
l Utilisez un ventilateur ou un aspira-
teur pour ôter les fumées des zones
de travail.
l Vermeiden Sie das Einatmen von
Schweibrauch!
l Sorgen Sie für gute Be- und
Entlüftung des Arbeitsplatzes!
l Mantenha seu rosto da fumaça.
l Use ventilação e exhaustão para
remover fumo da zona respiratória.
l Turn power off before servicing.
l Desconectar el cable de ali-
mentación de poder de la máquina
antes de iniciar cualquier servicio.
l Débranchez le courant avant l’entre-
tien.
l Strom vor Wartungsarbeiten
abschalten! (Netzstrom völlig öff-
nen; Maschine anhalten!)
l Não opere com as tampas removidas.
l Desligue a corrente antes de fazer
serviço.
l Não toque as partes elétricas nuas.
l Do not operate with panel open or
guards off.
l No operar con panel abierto o
guardas quitadas.
l N’opérez pas avec les panneaux
ouverts ou avec les dispositifs de
protection enlevés.
l Anlage nie ohne Schutzgehäuse
oder Innenschutzverkleidung in
Betrieb setzen!
l Mantenha-se afastado das partes
moventes.
l Não opere com os paineis abertos
ou guardas removidas.

CuSTOmER ASSiSTANCE pOLiCY
The business of The Lincoln Electric Company is manufacturing and
selling high quality welding equipment, consumables, and cutting
equipment. Our challenge is to meet the needs of our customers and
to exceed their expectations. On occasion, purchasers may ask
Lincoln Electric for advice or information about their use of our
products. We respond to our customers based on the best information
in our possession at that time. Lincoln Electric is not in a position to
warrant or guarantee such advice, and assumes no liability, with
respect to such information or advice. We expressly disclaim any
warranty of any kind, including any warranty of fitness for any
customer’s particular purpose, with respect to such information or
advice. As a matter of practical consideration, we also cannot assume
any responsibility for updating or correcting any such information or
advice once it has been given, nor does the provision of information
or advice create, expand or alter any warranty with respect to the sale
of our products.
Lincoln Electric is a responsive manufacturer, but the selection and
use of specific products sold by Lincoln Electric is solely within the
control of, and remains the sole responsibility of the customer. Many
variables beyond the control of Lincoln Electric affect the results
obtained in applying these types of fabrication methods and service
requirements.
Subject to Change – This information is accurate to the best of our
knowledge at the time of printing. Please refer to
www.lincolnelectric.com for any updated information.
Table of contents
Other Lincoln Electric Fan manuals
Popular Fan manuals by other brands

Daikin
Daikin C-Series installation manual

Matsui
Matsui MTF3613RE instruction manual

BLAUBERG Ventilatoren
BLAUBERG Ventilatoren Box-D Series Operation manual

Shop fox
Shop fox W1690 owner's manual

Milcor
Milcor Big Smoky Installation and maintenance instructions

Applica
Applica WDF1200 Series Use and care book