English 13 English
Parameters and functions description:
Preflow Time – time that shielding gas flows
after the torch trigger was pressed before prior
to wire feeding.
Regulation range: from 0 seconds (OFF) to
25 seconds.
Default settings for non-synergic mode: 0,2s.
Default settings for synergic mode: AUTO mode.
Postflow Time – time that shielding gas flows
after the welding stopped.
Regulation range: from 0 seconds (OFF)
to 25 seconds.
Default settings for non-synergic mode: 0,5s.
Default settings for synergic mode: AUTO mode.
Burnback Time - amount of time that the
welding is continued after the wire stops
feeding. It prevents the wire from sticking in
the puddle and prepares the end of the wire for the next
arc ignition.
Regulation range: from OFF to 0,25 seconds.
Default settings for non-synergic mode: 0,07s.
Default settings for synergic mode: AUTO mode.
Spot Welding Settings – sets the total
welding time even if the torch trigger is still
pressed. This function does not work in 4-Step
Trigger Mode.
Regulation range: from 0 second (OFF) to
120 seconds.
Default settings for non-synergic mode: OFF.
Default settings for synergic mode: OFF.
WARNING
Spot Timer has no effect in 4-Step Trigger Mode.
Run-in WFS – sets the wire feed speed from
the time the torch trigger is pressed until an
arc is established.
Regulation range: from minimum to 150 in/min (factory
default is set at Auto mode).
Default settings for non-synergic mode: OFF.
Default settings for synergic mode: AUTO mode.
Start Procedure – controls the WFS (or value
in ampere units) and Volts (or Trim) for a
specified time at the beginning of welding.
During the start time, the machine will ramp up or down
from the Start Procedure to the preset Welding
Procedure.
Adjust time range: from 0 seconds (OFF) to
10 seconds.
Default settings for non-synergic mode: OFF.
Default settings for synergic mode: AUTO mode.
Crater Procedure – controls the WFS (or
value in ampere units) and Volts (or Trim) for a
specified time at the end of the welding after
the trigger was released. During the crater time, the
machine will ramp up or down from the Weld Procedure to
the Crater Procedure.
Adjust time range: from 0 seconds (OFF) to
10 seconds.
Default settings for non-synergic mode: OFF.
Default settings for synergic mode: OFF.
MECHAPULSE™ - is available for all synergy
modes and produces very high quality welds
with rippled seam appearance. This effect is
achieved by combining two operating points,
two different wire feed speeds related to different arc
welding power.
Table 7 MECHAPULSE™ Parameters
Symbol Description
Frequency
Offset
TUNE1
TUNE2
A/B Procedure – enables quick weld
procedure change. The sequence changes
may occur between:
Two different welding programs.
Different settings for the same program.
Recall from the User Memory - recall the
stored programs from the user Memory. To
recall the Welding Program from the User
Memory:
Note: Before using, the Welding Program had to be
assigned to the user memory
Add the ʺLoadʺicon to the Welding Parameters Bar.
Use the Right Control [21] to highlight the ʺLoadʺ
memory icon.
Press the Right Control [21] to confirm – the ʺLoadʺ
memory menu is shown on the display.
Use the Right Control [21] to highlight the Memory
number from which Welding Program will be recall.
Confirm the selection – press the right button [21].
Save to the User Memory - Store the welding
programs with their parameters to one of the
fifty user memories. To save in memory:
Add icon „Save to the User Memoryʺto Welding
Parameters Bar.
Use the Right Control [21] to highlight the icon ʺSave
to the User Memoryʺ.
Figure 20