Linear DR2 Administrator guide

INSTR,CODE SET,DR2B RCVR
Linear P/N: 200867 B
Size: 8.500" x 11.000"
Material: 20 Lb. Mead Bond
Ink: Black
Scale: 1-1
DR2
DIGITAL
RECEIVER
Code Setting
Instructions
(800) 421-1587 •www.linearcorp.com
DESCRIPTION: The Delta-3 DR-2 digital receiver is a two-channel
wireless radio control designed for use with automatic garage/gate
operators and access control systems. The receiver can be
activated by any of the Delta-3 format transmitters. Receivers
must be mounted at least 8 feet apart.
The Delta-3 radio format provides 256 different digital codes. The
codes are set using the 8-position coding switches in the units.
✶
CAUTION: All transmitters and receivers should be
recoded by the installer prior to operation.
In order to avoid the possibility of duplicating codes in adjacent
systems, factory set codes should not be used. In addition, among
the valid codes available, four others should not be used. These
include: all keys set ON or OFF and keys set alternating ON/OFF.
Activate each transmitter to test the equipment.
☞WARNING! BE SURE DOOR OR GATE
AREAS ARE CLEAR OF OBSTRUCTIONS
STEP 1
Locate coding switch.
Locate the digital coding switch
which is recessed in the center of the back of the receiver case.
Note that the coding switch has eight keys. The keys are numbered
1 through 8. Key No. 1 is not used for coding the receiver; its
function is permanently wired on the circuit board.
STEP 2
Code the receiver.
Pick any combination of ON/ OFF
codes and set them on switch keys 2 through 8. Ignore Key 1. The
ON position is when the top of the switch is down. The OFF position
is when the top of the switch is up and the bottom is down. The
code set on Keys 2 through 8 on the receiver must now be matched
by all transmitters used in the system.
STEP 3
Code the transmitters.
Remove the battery access door
located on the back of the transmitter case to set transmitter
codes. Keys 2 through 8 must match keys 2 through 8 on the
receiver. To access channel #1, set key #1 to ON. To access
channel #2, set key #1 to OFF. Refer to transmitter code set
instructions to code multi-button transmitters.
STEP 4A
Connecting receiver (using transformer power).
A
Model 524 transformer can be used to power the receiver when
connecting receiver to any operator. Connect as shown, then plug
the transformer into a convenient (unswitched) 110 VAC outlet.
STEP 4B
Connecting receiver (using operator power).
Connect the receiver to the garage door or gate operator as shown
in the diagram. Power will be supplied from the operator. CAUTION:
All transmitters and receivers should be recoded
by the installer prior to operation
When Linearʼs digital transmitters and receivers
leave the factory, they are set to predetermined
codes — a separate code for each model.
It is not advisable to set a code with all keys ON,
OFF, or alternating ON and OFF, because these
codes are too easy to duplicate.
LINEAR LIMITED WARRANTY
This product is warranted to the consumer against defects in material and workmanship for one year from the
date of purchase. This warranty applies to first retail buyers of new devices. Warrantor will repair, or at its option,
replace, any device it finds that requires service under this warranty, and will return the repaired or replaced
device to the consumer at the warrantorʼs cost. For warranty service and shipping instructions contact warrantor
at the address shown below. Devices must be sent to warrantor for service at ownerʼs expense. The remedies
provided by this warranty are exclusive. Implied warranties under state law are to the one year period of this
written warranty. Some states do not allow limitations on how long an implied warranty lasts, so the above
limitation may not apply to you. In order to be protected by this warranty, save your proof of purchase and send
copy with equipment should repair be required. This warranty gives you specific legal rights, and you may also
have other rights which vary from state to state.
All products returned for warranty service require a Return Product Authorization Number (RPA#).
Contact Linear Technical Services at 1-800-421-1587 for an RPA# and other important details.
IMPORTANT !!!
Linear radio controls provide a reliable communications link and fill an important need in portable wireless
signaling. However, there are some limitations which must be observed.
✶For U.S. installations only: The radios are required to comply with FCC Rules and Regulations as Part 15
devices. As such, they have limited transmitter power and therefore limited range.
✶A receiver cannot respond to more than one transmitted signal at a time and may be blocked by radio signals
that occur on or near their operating frequencies, regardless of code settings.
✶Changes or modifications to the device may void FCC compliance.
✶Infrequently used radio links should be tested regularly to protect against undetected interference or fault.
✶A general knowledge of radio and its vagaries should be gained prior to acting as a wholesale distributor or
dealer, and these facts should be communicated to the ultimate users.
This device complies with FCC Rules Part 15 and IC Canada Rules and Regulations. Operation is subject to
the following two conditions: (1) This device may not cause harmful interference and (2) this device must accept
any interference received, including interference that may cause undesired operation.
Copyright © 1999 Linear Corporation 200867 B
DR2
SWITCHES IN
RECEIVER
THIS SWITCH
HAS 2, 3 & 6 ON
24 V RELAY RADIO
PWR
1 2 3 4 5 6 7 8
O
N
O
F
F
SET KEYS 2-8 TO CREATE RECEIVER CODE
DO NOT SET
KEY #1
OPEN
MATCH
2-8
KEY #1 ON KEY #1 OFF
TRIGGERS CH. 1 TRIGGERS CH. 2
TRANSMITTER
#1
TRANSMITTER
#2
MATCH
2-8
1 (-)
2 Relay
MANUAL
PUSHBUTTON
3 (+)
2 Relay
1
COM
2
RELAY
3
24 VAC
SILVER
COMMON
COPPER
N/O
RED
N/C
MANUAL
PUSHBUTTON
OPERATOR #1 OPERATOR #2
1 (-)
3 (+)
1
COM
2
RELAY
3
24 VAC
SILVER
COMMON
COPPER
N/O
RED
N/C
3 (+)
1 (-)
2 Relay
MANUAL
PUSHBUTTON
OPERATOR #2
MANUAL
PUSHBUTTON
3 (+)
1 (-)
2 Relay
OPERATOR #1
For more information:
www.devancocanada.com
or call toll free at 855-931-3334
HOW TO ORDER REPAIR PARTS
DEVANCO CANADA
19192 HAY ROAD, UNIT Q
SUMMERSTOWN, ON K0C 2E0
TOLL FREE: 855-931-3334
www.devancocanada.com
WHEN ORDERING REPAIR PARTS
PLEASE SUPPLY THE FOLLOWING INFORMATION:
3PART NUMBER
3DESCRIPTION
3MODEL NUMBER

Other Linear Receiver manuals

Linear GRD User manual

Linear

Linear GRD User manual

Linear D-2C Administrator guide

Linear

Linear D-2C Administrator guide

Linear Multi-Code 1099 User manual

Linear

Linear Multi-Code 1099 User manual

Linear SXR-64A User manual

Linear

Linear SXR-64A User manual

Linear MEGACODE MDR User manual

Linear

Linear MEGACODE MDR User manual

Linear AM-RGR User manual

Linear

Linear AM-RGR User manual

Linear MEGACODE MDR-U User manual

Linear

Linear MEGACODE MDR-U User manual

Linear MULTI-CODE 1099-31 User manual

Linear

Linear MULTI-CODE 1099-31 User manual

Linear DXR-702 User manual

Linear

Linear DXR-702 User manual

Linear DR4-12 User instructions

Linear

Linear DR4-12 User instructions

Linear COM3000 User manual

Linear

Linear COM3000 User manual

Linear DXR-701 User manual

Linear

Linear DXR-701 User manual

Linear 831 Series User manual

Linear

Linear 831 Series User manual

Linear DXSR-1504 User manual

Linear

Linear DXSR-1504 User manual

Linear DR2 User instructions

Linear

Linear DR2 User instructions

Linear 831-J User manual

Linear

Linear 831-J User manual

Linear MegaCode MGR-2 User manual

Linear

Linear MegaCode MGR-2 User manual

Linear XR-D User manual

Linear

Linear XR-D User manual

Linear Access Pro AP-1 User manual

Linear

Linear Access Pro AP-1 User manual

Linear DXSR-1504/EC User manual

Linear

Linear DXSR-1504/EC User manual

Linear MVP User manual

Linear

Linear MVP User manual

Linear XR-16 User manual

Linear

Linear XR-16 User manual

Linear XR-4 User manual

Linear

Linear XR-4 User manual

Linear Delta 3 User manual

Linear

Linear Delta 3 User manual

Popular Receiver manuals by other brands

Champion instruments PRO quick start guide

Champion instruments

Champion instruments PRO quick start guide

Peavey PRO COMM PCX-V12 operating manual

Peavey

Peavey PRO COMM PCX-V12 operating manual

Iluv i168 instruction manual

Iluv

Iluv i168 instruction manual

TANDBERG TT1282 user guide

TANDBERG

TANDBERG TT1282 user guide

Kathrein UFS 710si operating manual

Kathrein

Kathrein UFS 710si operating manual

Retro-Bit SEGA Saturn user manual

Retro-Bit

Retro-Bit SEGA Saturn user manual

Denon AVR-3310CI Product sheet

Denon

Denon AVR-3310CI Product sheet

Panasonic RF-B11 operating instructions

Panasonic

Panasonic RF-B11 operating instructions

Hallicrafters S-38C Operating and service instructions

Hallicrafters

Hallicrafters S-38C Operating and service instructions

Denon AVR-S920W quick start guide

Denon

Denon AVR-S920W quick start guide

TechniSat TECHNISTAR S6 Quick start manual

TechniSat

TechniSat TECHNISTAR S6 Quick start manual

TELECO AUTOMATION TRRCL868A60 quick start guide

TELECO AUTOMATION

TELECO AUTOMATION TRRCL868A60 quick start guide

Maxview MXL020HD operating manual

Maxview

Maxview MXL020HD operating manual

Cardio Theater On-LineWireless Digital Transmitter Installation and instruction manual

Cardio Theater

Cardio Theater On-LineWireless Digital Transmitter Installation and instruction manual

Metronic ECO Zapbox instruction manual

Metronic

Metronic ECO Zapbox instruction manual

Bpt mitho+ Technical manual

Bpt

Bpt mitho+ Technical manual

Sennheiser EK 1013-6 manual

Sennheiser

Sennheiser EK 1013-6 manual

Integra DTR-5 instruction manual

Integra

Integra DTR-5 instruction manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.