Linear SXR-64A User manual

SXR-64A
Supervised Wireless Receiver
and Zone Expander
Installation Instructions
INTRODUCTION
The Model SXR-64A is a 64-channel, 12-zone, supervised wireless receiver/
annunciator designed for use in residential or commercial security systems. Housed
in a rugged metal enclosure, the SXR-64A connects to a hardwired alarm control
panel adding wireless capability to the panel.
The SXR-64A receives signals from a variety of security transmitters then processes,
displays and transfers the signal to the hardwired alarm control panel. Six unique
conditions for each transmitter channel can be shown on the unit’s display. Conditions
such as “Open Portal”, “Transmitter Low Battery”, “Transmitter Tamper” and “First
Alarm In” show the status of each transmitter in the system. Valuable features such
as Alarm Memory and Transmitter Status allow for quick system diagnosis and
troubleshooting.
The receiver’s eight alarm zones and four supervisory zones provide a flexible
interface to the alarm control panel. Any or all of the zones can be used. All of the
solid state zone outputs can be either normally open or normally closed electrical
configuration and can switch up to 100 mA @ 24 VDC.
An easy programming interface using four pushbuttons lets the installer quickly setup
the system. The UP, DOWN, ADVANCE and MEMORY buttons are located inside the
receiver case and are used for transmitter and system programming.
An on-board, high-gain, superheterodyne radio receiver gives the SXR-64A excellent
reception. The MODE indicator shows RF activity. The local whip antenna (supplied)
or remote external antenna (Model EXA-1000) connects to the receiver through a
standard type “F” connector.
The SXR-64A decodes Linear’s SX, S1, and MegaCode™ format transmitters. The
SXR-64A can be used as a direct replacement for Linear’s SS-32, SSR-32, & SXR-64
receivers with an installation bonus of being able to use up to 64 transmitters in the
system.
Power for the SXR-64A is provided from the alarm control panel. To control the alarm
memory, reset tamper and status alert conditions, an armed input on the receiver
connects to an armed output from the control panel.
FEATURES
✶ 64 Programmable Transmitter Channels
✶ 8 Alarm Zones
✶ 4 Supervisory Zones
✶ Rugged Metal Enclosure
✶ Six Condition Displays for Each Transmitter
✶ Alarm Memory with First-Alarm-In
✶ Automatic Supervised Operation
✶ Transmitter Contact State Monitoring
✶ Transmitter Tamper Monitoring
✶ Transmitter Low Battery Monitoring
✶ Transmitter Status Report Monitoring
✶ Easy Installer Programming Interface
✶ High-gain Superheterodyne Receiver
✶ Receiver Automatic Gain Control
✶ Antenna Connector
✶ Decodes 303.875 MHz SX, S1, & MegaCode™ Format Transmitters
✶ Optional Display Blanking while Armed
✶ RF Activity Indicator
✶ Positive or Negative Armed Input
SYSTEM OVERVIEW CONDITION DISPLAYS COMPONENT LOCATIONS
INSTALLATION TIPS MOUNTING UNIT ANTENNA INSTALLATION
(760) 438-7000 • FAX (760) 438-7043
USA & Canada (800) 421-1587 & (800) 392-0123
Toll Free FAX (800) 468-1340
www.linearcorp.com
TERMINAL BLOCK DETAILS TYPICAL CONTROL PANEL CONNECTION S1 FORMAT TRANSMITTER DETAILS
PRINTER’S INSTRUCTIONS:
INSTR,INSTL,SXR-64A - LINEAR P/N: 220822 A - INK: BLACK - MATERIAL: 20 LB. MEAD BOND - SIZE: 11.000” X 17.000” - SCALE: 1-1 - SIDE 1 OF 2
TYPICAL TRANSMITTERS
TX-91 TX-92 TX-94 T-90D TMD-90 TSD-90A
SXR-64A RECEIVER ALARM CONTROL PANEL
UP TO 64 TRANSMITTERS
CAN BE USED
ST-23A LMT-1/303 MPX/303
CONDITIONS FOR ALL TRANSMITTERS
ROTATE ON THE DISPLAY
OPEN PORTAL
ALL TRANSMITTERS WILL CAUSE THIS CONDITION WHEN AN ALARM SIGNAL IS
SENT. THE CONDITION WILL REMAIN UNTIL A RESTORE SIGNAL IS SENT, UNLESS
THE TRANSMITTER IS SET AS "AUTO RESTORE". THE CHANNEL'S ZONE OUTPUT
WILL BE FAULTED WHEN THIS CONDITION IS DISPLAYED.
WHEN THE PANEL IS ARMED, THE FIRST ALARM SIGNAL SENT WILL CAUSE THIS
CONDITION. IF THE CHANNEL IS SET AS "DELAYED", THIS CONDITION WILL OCCUR
AFTER ANY DELAYS IF THE PANEL IS NOT DISARMED. DISPLAY WILL CLEAR THE
NEXT TIME THE PANEL IS RE-ARMED.
FIRST ALARM IN
WHEN THE PANEL IS ARMED, ADDITIONAL ALARM SIGNALS SENT WILL CAUSE THIS
CONDITION. IF THE CHANNEL IS SET AS "DELAYED", THIS CONDITION WILL OCCUR
AFTER ANY DELAYS IF THE PANEL IS NOT DISARMED. DISPLAY WILL CLEAR THE
NEXT TIME THE PANEL IS RE-ARMED.
ADDITIONAL ALARMS IN
ANY TRANSMITTER THAT CAN SEND A LOW BATTERY SIGNAL WILL CAUSE THIS
CONDITION WHEN ITS BATTERY IS LOW. DISPLAY WILL REMAIN UNTIL A SIGNAL
FROM THE SAME TRANSMITTER WITH A GOOD BATTERY IS SENT.
TRANSMITTER LOW BATTERY
ANY TRANSMITTER THAT CAN SEND A TAMPER SIGNAL WILL CAUSE THIS
CONDITION WHEN IT IS TAMPERED. DISPLAY WILL CLEAR THE NEXT TIME THE
PANEL IS ARMED.
TRANSMITTER TAMPER
IF THE RECEIVER DOES NOT RECEIVE STATUS SIGNALS FROM A TRANSMITTER
THAT IS SET AS SUPERVISED, THIS CONDITION WILL BE DISPLAYED. THE RECEIVER
CAN BE SET FOR TWO OR EIGHT HOURS OF MISSING STATUS TRANSMISSIONS
BEFORE THE CONDITION OCCURS. DISPLAY WILL CLEAR THE NEXT TIME THE
PANEL IS ARMED.
TRANSMITTER STATUS ALERT
ANTENNA CONNECTOR
TYPE "F" ANTENNA CONNECTOR FOR
CONNECTION TO LOCAL OR REMOTE
ANTENNA THROUGH RG-59 COAX
MODE LIGHT
TRANSMITTER DISPLAY
CONDITION DISPLAY
MEMORY LIGHT
UP & DOWN BUTTONS
ADVANCE BUTTON
MEMORY BUTTON
TERMINAL BLOCK
LIGHTS WHEN UNIT IS
IN PROGRAM MODE,
FLASHES WHEN RF IS
RECEIVED IN RUN
MODE
SHOWS THE TRANSMITTER'S
CHANNEL NUMBER AND IS USED
DURING PROGRAMMING
WIRING KNOCKOUTS
SHOWS THE TRANSMITTER'S
CONDITION AND IS USED DURING
PROGRAMMING
LIGHTS DURING PROGRAM
MODE TO SHOW WHEN A
TRANSMITTER HAS BEEN
ENTERED OR AN OPTION
HAS BEEN SELECTED,
LIGHTS DURING RUN MODE
WHEN SYSTEM IS ARMED,
BLINKS DURING EXIT DELAY
USED DURING PROGRAMMING
TO SELECT OPTIONS AND
ENTER TRANSMITTERS
USED DURING PROGRAMMING
TO CHANGE ZONE NUMBERS
AND SELECT FUNCTIONS
PRESS EITHER TO ENTER
PROGRAM MODE, UP
INCREASES AND DOWN
DECREASES VALUE DISPLAYED
PRESS TOGETHER TO EXIT
PROGRAM MODE
FOR WIRING CONDUIT
CONNECTION
CONNECTIONS FOR ZONE AND
SUPERVISORY OUTPUTS,
POWER AND ARMED INPUTS
TEST POINTS
AUDIO TEST
POINTS FOR
LISTENING TO
RADIO INPUT
WITH BUTTSET
WRONG!
RIGHT
CENTRALLY LOCATE RECEIVER
OR ANTENNA
TRANSMITTERS AT THE OTHER END OF
HOUSE MIGHT BE TOO FAR AWAY
BASEMENT BASEMENT
RCVR RCVR
RIGHT
WRONG!
LOCATING A RECEIVER OR ANTENNA BELOW
EARTH LEVEL WILL IMPAIR RANGE
MOUNT RECEIVER OR ANTENNA AS HIGH ABOVE
EARTH LEVEL AS POSSIBLE
90% - 100%
OF FULL POWER
65% - 95%
OF FULL POWER
10% - 70%
OF FULL POWER
WALLBOARD AND
WOOD STUDS
CONCRETE WITH STEEL
REINFORCEMENT OR
METAL LATH AND PLASTER
LIGHT CONCRETE
OR BRICK
TX
Concrete
slab
floor
DOOR
TX
Concrete
slab
floor
DOOR
Less
than
3 ft.
above
slab
Min.
3 ft.
RIGHT
WRONG!
TX
Wall
WRONG!
Large
metal
appliance
(refrig.)
CONSTRUCTION
MATERIALS WILL
EFFECT RADIO RANGE
RECEIVER (ANTENNA)
LOCATION EFFECTS
RADIO RANGE
TRANSMITTER
MOUNTING WILL
EFFECT RADIO
RANGE
ATTACH CASE WITH
TWO SCREWS IN
KEYHOLE SLOTS,
THEN SECURE CASE
WITH TWO BOTTOM
SCREWS
7"
5" 5"
USE SCREWS AND ANCHORS TO
MOUNT THE RECEIVER
MOUNTING
PATTERN
USE LOCAL
WHIP ANTENNA
(SUPPLIED)
- OR -
USE THE
MODEL EXA-1000
REMOTE ANTENNA
(OPTIONAL)
CONNECT ANTENNA
COAX DIRECTLY OR
USE UP TO 25 FEET
OF RG-59 COAX AS
AN EXTENSION
1 2 3 4 5 6 7 8 9 1011121314151617181920
ZN1 COM ZN2 ZN3 COM ZN4 ZN5 COM ZN6 ZN7 COM ZN8 LB STS COM TMP TST ARM
SXR-64A TERMINALS
ZONE OUTPUTS
LOW BATTERY OUTPUT
FOR CONNECTION TO ALARM ZONE INPUTS ON THE ALARM
CONTROL PANEL. ZONE OUTPUT WILL ACTIVATE WHEN ANY
TRANSMITTER CHANNEL PROGRAMMED FOR THAT ZONE IS
IN THE FAULTED (ALARM/OPEN) CONDITION ("O" DISPLAYED
ON THE CONDITION DISPLAY).
STATUS OUTPUT
TAMPER OUTPUT
FOR CONNECTION TO A TROUBLE ZONE ON THE ALARM
CONTROL PANEL. OUTPUT WILL ACTIVATE WHEN ANY
TRANSMITTER CHANNEL DISPLAYS A "P" ON THE CONDITION
DISPLAY OR WHEN ANY PROGRAMMING BUTTON IS
PRESSED WHILE THE SYSTEM IS ARMED.
TEST OUTPUT
POWER INPUT
ARMED INPUT
FOR CONNECTION TO THE ALARM
CONTROL PANEL'S ARMED OUTPUT.
THE ARMED INPUT CAN BE SET FOR
ARMED-POSITIVE OR
ARMED-NEGATIVE POLARITY.
NOTES:
1. ALL COM TERMINALS ARE COMMON GROUND
AND CONNECTED TOGETHER.
2. ALL OUTPUTS CAN BE PROGRAMMED FOR NORMALLY
OPEN OR NORMALLY CLOSED OPERATION. EACH OUTPUT
RETURNS TO ANY COM TERMINAL.
3. EACH OUTPUT CAN SWITCH UP TO 100 mA @ 24 VDC
MAXIMUM.
FOR CONNECTION TO A TEST ZONE ON THE ALARM
CONTROL PANEL. OUTPUT WILL ACTIVATE WHEN ANY
TRANSMITTER THAT CAN SEND A TEST SIGNAL HAS ITS
TEST BUTTON PRESSED.
FOR CONNECTION TO A TROUBLE ZONE ON THE ALARM
CONTROL PANEL. OUTPUT WILL ACTIVATE WHEN ANY
TRANSMITTER CHANNEL DISPLAYS AN "S" ON THE
CONDITION DISPLAY.
FOR CONNECTION TO A TROUBLE ZONE ON THE ALARM
CONTROL PANEL. OUTPUT WILL ACTIVATE WHEN ANY
TRANSMITTER CHANNEL DISPLAYS AN "L" ON THE
CONDITION DISPLAY.
FOR CONNECTION TO THE ALARM
CONTROL PANEL'S AUXILIARY
POWER OUTPUT. POWER INPUT
CAN BE FROM 11-16 VDC ONLY
1 2 3 4 5 6 7 8 9 1011121314151617181920
ZN1 COM ZN2 ZN3 COM ZN4 ZN5 COM ZN6 ZN7 COM ZN8 LB STS COM TMP TST ARM
SXR-64A TERMINALS
END-OF-LINE
RESISTORS
ALARM CONTROL PANEL
8
ZONE 1
COMMON
ZONE 2
ZONE 3
ZONE 4
ZONE 5
ZONE 6
ZONE 7
ZONE 8
COMMON
COMMON
COMMON
AUXILIARY
POWER
ARMED
OUTPUT
OUTPUTS PROGRAMMED
FOR NORMALLY OPEN
CHANNEL
SWITCH
SYSTEM
SWITCH
SET CHANNEL AND
SYSTEM SWITCH TO
ANY UNIQUE CODE
EACH S1 FORMAT
TRANSMITTER MUST
BE SET TO A DIFFERENT
CODE
MODEL ST
MODEL ST-1
CHANNEL
SWITCH
SYSTEM
SWITCH
MODEL 50S40A
WHEN UPGRADING AN SS-32,
SSR-32, OR SXR-64 INSTALLATION,
THE TRANSMITTER SWITCH
SETTINGS CAN REMAIN THE SAME
ST-1 & 50S40A NOTE: SET SXR-64A TRANSMITTER OPTION "A"
TO "ON" FOR THE CHANNEL THE TRANSMITTER IS PROGRAMMED TO.
OTHERWISE, THE LONG ALARM AND RESTORE
TRANSMISSIONS WILL CAUSE A DOUBLE ZONE CLOSURE
SYSTEM
SWITCH
CHANNEL
SWITCH
MODEL ST-23A
ST-23A NOTE: SET
SYSTEM SWITCH #1
TO OFF
STATUS
JUMPER
RESTORE
JUMPER
CUT ST-1 JUMPERS
TO ENABLE STATUS
& RESTORE SIGNALS
CHANNEL
SWITCH
SYSTEM
SWITCH

Copyright © 2003 Linear Corporation 220822 A
ERASING SINGLE-CHANNEL TRANSMITTERS ERASING MULTI-BUTTON TRANSMITTERS SETTING RECEIVER OPTIONS
TRANSMITTER COUNT VERIFYING TRANSMITTERS SYSTEM TESTING
HOOKUP: MOOSE Z1100 & CADDX RANGER 9000 HOOKUP: C&K 236 & NAPCO MA1000 LINEAR LIMITED WARRANTY
This Linear product is warranted against defects in material and workmanship for twelve (12)
months. The Warranty Expiration Date is labeled on the product. This warranty extends only
to wholesale customers who buy direct from Linear or through Linear’s normal distribution
channels. Linear does not warrant this product to consumers. Consumers should inquire from
their selling dealer as to the nature of the dealer’s warranty, if any. There are no obligations or
liabilities on the part of Linear Corporation for consequential damages arising out of or in
connection with use or performance of this product or other indirect damages with respect
to loss of property, revenue, or profit, or cost of removal, installation, or reinstallation.
All implied warranties, including implied warranties for merchantability and implied warranties
for fitness, are valid only until Warranty Expiration Date as labeled on the product. This Linear
Corporation Warranty is in lieu of all other warranties express or implied.
All products returned for warranty service require a Return Product Authorization Number (RPA#).
Contact Linear Technical Services at 1-800-421-1587 for an RPA# and other important details.
IMPORTANT !!!
Linear radio controls provide a reliable communications link and fill an important need in portable
wireless signalling. However, there are some limitations which must be observed.
✶ For U.S. installations only: The radios are required to comply with FCC Rules and Regulations
as Part 15 devices. As such, they have limited transmitter power and therefore limited range.
✶ A receiver cannot respond to more than one transmitted signal at a time and may be blocked
by radio signals that occur on or near their operating frequencies, regardless of code
settings.
✶ Changes or modifications to the device may void FCC compliance.
✶ Infrequently used radio links should be tested regularly to protect against undetected
interference or fault.
✶ A general knowledge of radio and its vagaries should be gained prior to acting as a wholesale
distributor or dealer, and these facts should be communicated to the ultimate users.
ENTERING SINGLE-CHANNEL TRANSMITTERS ENTERING MULTI-BUTTON TRANSMITTERS SETTING TRANSMITTER OPTIONS
PRINTER’S INSTRUCTIONS:
INSTR,INSTL,SXR-64A - LINEAR P/N: 220822 A - INK: BLACK - MATERIAL: 20 LB. MEAD BOND - SIZE: 11.000” X 17.000” - SCALE: 1-1 - SIDE 2 OF 2
OR
RECEIVER CHANNEL NUMBER (64 SHOWN)
ZONE NUMBER (1 SHOWN)
MEMORY LIGHT WILL BE OFF IF THE RECEIVER
CHANNEL IS VACANT (ONLY A VACANT RECEIVER
CHANNEL CAN ACCEPT A TRANSMITTER)
PRESS [MEMORY]
MEMORY LIGHT WILL BLINK, SHOWING THAT THE
RECEIVER IS READY TO ACCEPT A TRANSMITTER
ACTIVATE THE TRANSMITTER
THE MEMORY LIGHT WILL GO ON, SHOWING
THAT THE TRANSMITTER WAS ENTERED AND
THE RECEIVER'S DISPLAYED CHANNEL IS OCCUPIED
WITH THE PANEL DISARMED, PRESS [UP] OR [DOWN]
UNTIL THE DESIRED RECEIVER CHANNEL
NUMBER (1-64) IS DISPLAYED
CHANNEL ZONE
CHANNEL ZONE
PRESS [ADVANCE] TO SELECT THE OUTPUT ZONE
NUMBER (1-8) FOR THE DISPLAYED
RECEIVER CHANNEL NUMBER
RECEIVER CHANNEL NUMBER (64 SHOWN)
ZONE NUMBER (3 SHOWN)
NOTE: ARMING THE CONTROL PANEL ANYTIME
DURING PROGRAMMING WILL CAUSE THE SXR-64A TO
EXIT PROGRAM MODE AND RETURN TO RUN MODE
OR
RECEIVER CHANNEL NUMBER (64 SHOWN)
IGNORE ZONE NUMBER (3 SHOWN)
MEMORY LIGHT WILL BE ON, SHOWING THAT THE
RECEIVER CHANNEL IS OCCUPIED
PRESS [MEMORY]
MEMORY LIGHT WILL BLINK, SHOWING THAT THE
RECEIVER IS READY TO ERASE A TRANSMITTER
FROM THE DISPLAYED RECEIVER CHANNEL
PRESS [MEMORY] AGAIN
MEMORY LIGHT WILL GO OFF, SHOWING
THAT THE TRANSMITTER HAS BEEN ERASED
AND THAT THE RECEIVER'S CHANNEL IS VACANT
WITH THE PANEL DISARMED, PRESS [UP] OR [DOWN]
TO DISPLAY THE RECEIVER CHANNEL NUMBER WITH
THE SINGLE-CHANNEL TRANSMITTER TO ERASE
CHANNEL ZONE
OR
WITH THE PANEL DISARMED,
PRESS [UP] OR [DOWN] UNTIL "Fn" IS DISPLAYED
("Fn" IS BETWEEN "1" AND "64")
"Fn" DISPLAYED (RECEIVER OPTIONS FUNCTIONS)
PRESS [ADVANCE] UNTIL THE DESIRED FUNCTION
LETTER (1-d) IS DISPLAYED
CONFIGURATION OPTION DISPLAYED
(FUNCTION "b" SHOWN)
Fn # MEMORY LIGHT
OFF
MEMORY LIGHT
ON
ARMED WHEN
ARM=GROUND
ARMED WHEN
ARM=VOLTAGE
TBD
TBD
DISPLAY BLANK
WHEN ARMED
DISPLAY ON AT
ALL TIMES
STATUS ALERTS
AFTER 2 HOURS
STATUS ALERTS
AFTER 8 HOURS
OUTPUTS
NORM. CLOSED
OUTPUTS
NORMALLY OPEN
ONE OF THE
OTHER DELAYS
ENTRY DELAY
0 SECONDS
ENTRY DELAY
20 SECONDS
ONE OF THE
OTHER DELAYS
Fn # MEMORY LIGHT
OFF
MEMORY LIGHT
ON
ONE OF THE
OTHER DELAYS
ENTRY DELAY
40 SECONDS
ONE OF THE
OTHER DELAYS
ENTRY DELAY
60 SECONDS
EXIT DELAY
0 SECONDS
ONE OF THE
OTHER DELAYS
EXIT DELAY
20 SECONDS
EXIT DELAY
40 SECONDS
EXIT DELAY
60 SECONDS
ONE OF THE
OTHER DELAYS
ONE OF THE
OTHER DELAYS
ONE OF THE
OTHER DELAYS
SET EXIT AND ENTRY DELAYS A LITTLE LONGER
THAN THE CONTROL PANEL'S DELAYS
FUNCTION
FUNCTION OPTION
FOLLOW THE TABLE AND USE THE [MEMORY] BUTTON
AND MEMORY LIGHT TO SELECT FUNCTION OPTIONS
FACTORY DEFAULT SETTINGS
★
★
★
★
★
★
★
★
★
★
★
★
★
★
OR
WITH THE PANEL DISARMED, PRESS [UP] OR [DOWN]
UNTIL THE DESIRED RECEIVER CHANNEL NUMBER
FOR THE MULTI-BUTTON TRANSMITTER IS DISPLAYED
RECEIVER CHANNEL NUMBER (40 SHOWN)
ZONE NUMBER (1 SHOWN)
PRESS [ADVANCE] UNTIL THE DESIRED OUTPUT
ZONE NUMBER (1-8) FOR A TRANSMITTER BUTTON
IS DISPLAYED
RECEIVER CHANNEL NUMBER (40 SHOWN)
ZONE NUMBER (5 SHOWN)
CHANNEL
ZONE
CHANNEL
ZONE
MEMORY LIGHT WILL GO ON, SHOWING THAT THE
BUTTON WAS PROGRAMMED
PRESS [MEMORY]
MEMORY LIGHT WILL BLINK, SHOWING THAT THE
RECEIVER IS READY TO ACCEPT THE TRANSMITTER
BUTTON
PRESS THE DESIRED TRANSMITTER BUTTON (TO
CREATE A DOUBLE-BUTTON LOCKOUT TRANSMITTER,
PRESS TWO BUTTONS AT THE SAME TIME)
REPEAT ZONE SELECTION TO PROGRAM ADDITIONAL
BUTTONS ON THE TRANSMITTER
NOTE: EACH MULTI-BUTTON TRANSMITTER USES ONE RECEIVER
CHANNEL AND A DIFFERENT OUTPUT ZONE FOR EACH BUTTTON
MEMORY LIGHT WILL BE OFF IF THE RECEIVER
CHANNEL IS VACANT (ONLY A VACANT RECEIVER
CHANNEL CAN ACCEPT A TRANSMITTER)
OR
RECEIVER CHANNEL NUMBER (40 SHOWN)
ZONE NUMBER (5 SHOWN)
(THE FIRST ZONE NUMBER ENTERED FOR THE
MULTI-BUTTON TRANSMITTER IS DISPLAYED)
MEMORY LIGHT WILL BE ON, SHOWING THAT THE
RECEIVER CHANNEL IS OCCUPIED WITH A
TRANSMITTER BUTTON LINKED TO THAT ZONE
PRESS [MEMORY]
MEMORY LIGHT WILL BLINK, SHOWING THAT THE
RECEIVER IS READY TO ERASE THE TRANSMITTER
BUTTON FROM THE RECEIVER'S CHANNEL AND ZONE
PRESS [MEMORY] AGAIN
MEMORY LIGHT WILL GO OFF, SHOWING THAT THE
TRANSMITTER BUTTON HAS BEEN ERASED
WITH THE PANEL DISARMED, PRESS [UP] OR [DOWN]
TO DISPLAY THE RECEIVER CHANNEL NUMBER WITH
THE MULTI-BUTTON TRANSMITTER TO ERASE
CHANNEL ZONE
PRESS [ADVANCE] UNITL THE NEXT ZONE NUMBER
USED WITH THE SAME MULTI-BUTTON TRANSMITTER
IS DISPLAYED
CHANNEL ZONE
RECEIVER CHANNEL NUMBER (40 SHOWN)
ZONE NUMBER (6 SHOWN)
REPEAT TO ERASE ANY ADDITIONAL BUTTONS THAT
WERE ENTERED FOR THAT TRANSMITTER
OR
RECEIVER CHANNEL NUMBER (64 SHOWN)
ZONE NUMBER (8 SHOWN)
(FOR MULTI-BUTTON TRANSMITTERS, THE FIRST ZONE
NUMBER ENTERED IS DISPLAYED)
PRESS [ADVANCE] UNTIL THE DESIRED OPTION
LETTER (A-d) IS DISPLAYED
(LETTERS ARE DISPLAYED BETWEEN "8" AND "1")
FOLLOW THE TABLE BELOW AND USE THE [MEMORY]
BUTTON AND MEMORY LIGHT TO SELECT OPTIONS
CONFIGURATION OPTION DISPLAYED
(CHANNEL 64, OPTION "b" SHOWN)
OPTION MEMORY LIGHT
OFF
MEMORY LIGHT
ON
AUTO-RESTORE TX
(PIR & PORTABLES)
SELF-RESTORE TX
(DOORS & WINDOWS)
NO TX STATUS
REPORTS
TX MAKES STATUS
REPORTS
TX USES ENTRY &
EXIT DELAYS
TRANSMITTER
IS INSTANT
UNARMED ALARM
MEMORY FOR TX
ALARM MEMORY
ONLY WHEN ARMED
CHANNEL
ZONE
CHANNEL
OPTION
WITH THE PANEL DISARMED, PRESS [UP] OR
[DOWN] UNTIL THE DESIRED RECEIVER
CHANNEL NUMBER IS DISPLAYED
FACTORY DEFAULT SETTINGS
★
★
★
★
★
OR
WITH THE PANEL DISARMED,
PRESS [UP] OR [DOWN] UNTIL "Fn" IS DISPLAYED
("Fn" IS BETWEEN "1" AND "64")
"Fn" DISPLAYED (RECEIVER OPTIONS FUNCTION)
PRESS [ADVANCE] UNTIL THE DISPLAY SHOWS
THE OPTION "0"
PRESS [MEMORY]
RECEIVER OPTION "FUNCTION 0"
FUNCTION
FUNCTION OPTION
DISPLAY SHOWS TOTAL NUMBER OF TRANSMITTERS
IN MEMORY FOR 10 SECONDS
# OF TXS
NOTE:
PRESSING [UP] AND [DOWN] TOGETHER ANYTIME
DURING PROGRAMMING WILL CAUSE THE SXR-64A TO
EXIT PROGRAM MODE AND RETURN TO RUN MODE
OR
WITH THE PANEL DISARMED,
PRESS [UP] OR [DOWN] UNTIL "Fn" IS DISPLAYED
("Fn" IS BETWEEN "1" AND "64")
"Fn" DISPLAYED (RECEIVER OPTIONS FUNCTION)
PRESS [ADVANCE] UNTIL THE DISPLAY SHOWS
THE OPTION "E"
PRESS AND RELEASE [MEMORY] THEN WAIT 5 SECONDS
RECEIVER OPTION "FUNCTION E"
FUNCTION
DISPLAY SCROLLS THROUGH EACH CHANNEL AND
LINKED ZONE. VERIFY THAT EACH CHANNEL IS LINKED
TO THE CORRECT ZONE. (THE FIRST ZONE NUMBER
ENTERED FOR A MULTI-BUTTON TRANSMITTER IS
DISPLAYED)
CHANNEL ZONE
FUNCTION OPTION
ACTIVATE EACH TRANSMITTER. WHEN THE RECEIVER
DECODES THE TRANSMITTER, IT WILL BE REMOVED
FROM THE DISPLAY. CONTINUE TESTING UNTIL NO
TRANSMITTERS REMAIN ON THE DISPLAY. PRESS
THE [MEMORY] BUTTON OR WAIT 10 MINUTES TO END
THE TEST.
WITH THE PANEL DISARMED, OPEN A PROTECTED
DOOR OR WINDOW
THE CHANNEL NUMBER AND "O" SHOULD BE
DISPLAYED (CHANNEL 64, OPEN CONDITION SHOWN)
CLOSE THE PROTECTED DOOR OR WINDOW
ARM THE CONTROL PANEL THEN OPEN A PROTECTED
DOOR OR WINDOW (AFTER ANY DELAYS)
THE "O" SHOULD DISAPPEAR WHEN THE TRANSMITTER
RESTORES. DASHES WILL SHOW IF ALL PORTALS
ARE CLOSED.
DISPLAY SHOULD SHOW AN "F" CONDITION FOR THE
FIRST ALARM IN
OPEN ADDITIONAL PROTECTED PORTALS. DISPLAY
SHOULD SHOW AN "A" FOR EACH ADDITIONAL ALARM
SIGNAL SENT. ALARM MEMORY WILL CLEAR WHEN
THE CONTROL PANEL IS DISARMED AND REARMED.
TRANSMITTER
CONDITION
TRANSMITTER
CONDITION
TRANSMITTER
CONDITION
1 2 3 4 5 6 7 8 9 10 111213141516171819 20
ZN1 COM ZN2 ZN3 COM ZN4 ZN5 COM ZN6 ZN7 COM ZN8 LB STS COM TMP TST ARM
SXR-64A TERMINALS
MOOSE Z1100
ZN1
1
COM
2
ZN2
3
ZN3
4
COM
5
ZN4
6
ZN5
7
COM
8
ZN6
9
AUX
POWER
2.2K EOL
RESISTORS
(ZONES PROGRAMMED
NORMALLY CLOSED)
(PROGRAMMED FOR
VOLTAGE WHEN ARMED)
ZN7
10
COM
11
ZN8
12
J16
8
28 29
1 2 3 4 5 6 7 8 9 10 111213141516171819 20
ZN1 COM ZN2 ZN3 COM ZN4 ZN5 COM ZN6 ZN7 COM ZN8 LB STS COM TMP TST ARM
SXR-64A TERMINALS
CADDX RANGER 9000
ZN1
1
COM
2
ZN2
3
ZN3
4
COM
5
ZN4
6
ZN5
7
COM
8
ZN6
9
AUX
POWER
3.3K EOL
RESISTORS
(ZONES PROGRAMMED
NORMALLY CLOSED)
AUX
OUT
(PROGRAMMED FOR
GROUND WHEN ARMED)
1234
ZN7
10
COM
11
ZN8
12
ZN9
15
ZN10
17
COM
16
ZN11
18
14 13
1 2 3 4 5 6 7 8 9 10 111213141516 171819 20
ZN1 COM ZN2 ZN3 COM ZN4 ZN5 COM ZN6 ZN7 COM ZN8 LB STS COM TMP TST ARM
SXR-64A TERMINALS
C&K 236
Z1
C
Z2 Z3
C
Z4 Z5
C
Z6
AUX
POWER
2.2K EOL
RESISTORS
(ZONES PROGRAMMED
NORMALLY CLOSED)
(PROGRAMMED FOR
VOLTAGE WHEN ARMED)
1 2 3 4 5 6 7 8 9 10 111213141516 171819 20
ZN1 COM ZN2 ZN3 COM ZN4 ZN5 COM ZN6 ZN7 COM ZN8 LB STS COM TMP TST ARM
SXR-64A TERMINALS
NAPCO MA1000e
ZN1
15
COM
14
ZN2
16
ZN3
17
ZN4
19
ZN5
20
COM
18
ZN6
21
AUX
POWER
2.2K EOL
RESISTORS
(ZONES PROGRAMMED
NORMALLY CLOSED)
(PROGRAMMED FOR
GROUND WHEN ARMED)
56
NOTE: THIS PANEL DOES NOT
SUPPLY AN ARMED SIGNAL.
USE A PUSHBUTTON TO
RESET THE ALARM MEMORY
WHEN THE PANEL IS ARMED.
SET SXR-64A DELAYS TO "0"
AUX
C
RESET
E3 PGM
Table of contents
Other Linear Receiver manuals

Linear
Linear XR-16 User manual

Linear
Linear MVP User manual

Linear
Linear 831 Series User manual

Linear
Linear DXSR-1504/EC User manual

Linear
Linear MEGACODE MDR-U User manual

Linear
Linear Delta 3 User manual

Linear
Linear DR2 User instructions

Linear
Linear 831 Series User manual

Linear
Linear Multi-Code 1099 User manual

Linear
Linear 831-J User manual

Linear
Linear DXSR-1504 User manual

Linear
Linear XR-4 User manual

Linear
Linear AM-RGR User manual

Linear
Linear D-2C Administrator guide

Linear
Linear XR-D User manual

Linear
Linear MULTI-CODE 1099-31 User manual

Linear
Linear DXR-702 User manual

Linear
Linear DXR-701 User manual

Linear
Linear TRANS PROX Devices ACT-31D User manual

Linear
Linear 831-S, 24 VAC User manual