5m
7m
9m
11m
12m
13m
15m
ENVY WIND RANGE
5m
6m
7m
8m
9m
10.5m
12m
15m
35kts++
25kts++
21-35kts
19-33kts
16-29kts
13-27kts
7-18kts
9-22kts
HIFI-X WIND RANGE
32kts++
28kts++
18-33kts
14-26kts
12-24kts
10-22kts
8-15kts
Wind range is highly subjective and based largely on rider weight and skill. The numbers on the kites represent the effective
POWER progression of the kites CLOSELY related to actual area. Kites come in different sizes for different windspeeds and rider
weights,so if you want to ride every windy day, you have to buy a couple kites to cover all the wind situations so you can ride in
any winds. Most kitesurfers have 2-3 kites to cover all situations.
To inflate your kite using
the LF MAX Inflation
System, gently twist open
the top cap of the valve.
If the RED one way wall is in
open position, it is strongly
suggested to close it before
inserting the pump nozzle.
Push inside, with gentle
pressure, the Liquid Force
dedicated wide nozzle
included with the Liquid Force
pump, when the nozzle is
secured inside, start pumping
until you reach 6 to 8 PSI of
pressure (to the rider’s choice).
** Please note, DO NOT push
the valve from the bottom, this
could cause possible damage
your bladder.
Once you have reached 6 to 8
PSI, slowly remove the pump
nozzle,the inside RED one way
wall will fall into place
preventing the air form
coming out. If for any reason
there would be a small airflow
noise, quickly push down the
RED one-way wall, it will then
fall back into is dedicated
location.
Lightly close the top cap
after inflation, DO NOT over
rotate the top cap, this
could make it hard to open
again and create a possible
twist the bladder around
the valve. Keep in mind
that the RED one-way wall
is there to keep the air
inside the bladder, and the
top cap is only there to
prevent sand or water to
enter the valve.
INFLATION PROCESS
DEFLATION PROCESS
To deflate your kite using
the LF MAX Inflation
System, gently twist open
the top cap of the valve. At
this point the air is still
locked inside the LE.
Slightly push the inside RED
one-way wall towards the
inside of the valve using 1
finger. This will slowly initiate
the release of the air.
When 25-50% of the air is out of
the kite, you will be able to push
down completely the RED one
way wall, and lock and secure it
open it inside the hole. This will
open wide the flow of the valve
to ensure the kite completely
deflates. If the RED one-way wall
closes back, push it back down
further to lock it in the OPEN
position.
When your kite is rolled
and ready to put in the bag,
we suggest you close
lightly the valve CAP to
prevent any sand or
undesirable objects to
enter your bladder.
REMOVING THE BLADDER WITH MAXFLOW FROM THE KITE
If the event of a slow leak or punctured
bladder in your leading edge (LE)
bladder, you have to seperate the
MaxFLow valve from the LE of the Kite.
First remove the cap from the valve.
Next unscrew the base of the MaxFlow
valve that is holding the valve in place.,
this will free your valve from the kite LE
sleeve and allow you to push the valve
into the LE for bladder removal.
Now, You can then fix your bladder
and set it back into the LE sleeve easily
by reversing the process of the
removal.How easy was that!
MaxFlowInflationSystem KiteWindRange
WOW WIND RANGE
25kts++
21-35kts
19-33kts
16-29kts
14-28kts
9-22kts
4.5M
6.5m
9m
12m
15.5m
17.5
20-32kts
14-24kts
9-18kts
32kts++
7-13kts
SOLO WIND RANGE
6-12kts