Lite-Puter ECP-110T User manual

ISO 9001 CERTIFIED www.liteputer.com.tw
Lite-Puter
ECP-110T[EUM-B]
ECP-110T
Control Panel
【USER MANUAL】
Lite Puter Enterprise Co., Ltd.
Website: www.liteputer.com.tw
E-mail:sales@liteputer.com.tw

ISO 9001 CERTIFIED www.liteputer.com.tw
Lite-Puter
ECP-110T[EUM-B]
INDEX
1. INTRODUCTION............................................................................................................................................1
1-1 FEATURES ........................................................................................................................................................ 1
1-2 SPECIFICATIONS ................................................................................................................................................ 1
1-3 PANEL INTRODUCTIONS ...................................................................................................................................... 1
1-4 HOW TO OPEN FRONT COVER ............................................................................................................................. 3
1-5 WIRING .......................................................................................................................................................... 3
2. OPERATIONS ................................................................................................................................................4
2-1 ZONE SETTING.................................................................................................................................................. 4
2-1-1 About EDX System................................................................................................................................ 4
2-1-2 Purpose of Zone Setting ....................................................................................................................... 5
2-1-3 Zone Setting ......................................................................................................................................... 5
2-1-4 Zone Setting of DIP............................................................................................................................... 8
2-2 SCENE RECALL .................................................................................................................................................. 8
2-3 FINE ADJUST DIMMING LEVEL ............................................................................................................................. 8
2-4 LOCK/UNLOCK ................................................................................................................................................. 8
2-5 IR REMOTE CONTROL ........................................................................................................................................ 9
2-6 DRY CONTACT INPUTS...................................................................................................................................... 10
APPENDIX: BINARY CODE PRINCIPAL.................................................................................................11
LIMITED WARRANTY......................................................................................................................................12

ISO 9001 CERTIFIED www.liteputer.com.tw
Lite-Puter
ECP-110T[EUM-B]
1
1. Introduction
1-1 Features
1. In multi-zone mode, one ECP-110T can control up to 8 zones at the same time.
2. Recall 6 scenes.
3. Fine adjust the dimming level.
4. 256 level dimming resolutions.
5. Key Lock /unlock function.
6. IR receiver.
7. Two dry contact inputs.
1-2 Specifications
1. Protocol:EDX (RS-485)
2. Connector:4 pin green terminal
3. Dimension:86(W) X 86(H) X21(D) mm
4. Weight:130 g
1-3 Panel Introductions
Front Side:

ISO 9001 CERTIFIED www.liteputer.com.tw
Lite-Puter
ECP-110T[EUM-B]
2
Rear side:
1. Scene 1 ~ 6, scene OFF
2. 【▼】: Down ; 【▲】: Up
3. 【ZONE】: zone
4. DIP switch

ISO 9001 CERTIFIED www.liteputer.com.tw
Lite-Puter
ECP-110T[EUM-B]
3
1-4 How to Open Front Cover
:Slotted Screwdriver
1-5 Wiring

ISO 9001 CERTIFIED www.liteputer.com.tw
Lite-Puter
ECP-110T[EUM-B]
4
2. Operations
2-1 Zone Setting
2-1-1 About EDX System
EDX is a protocol specifically designed for architectural and environmental lighting
applications. EDX dimmers or devices are able to store scenes in themselves.
Each EDX device or ECP panel can be assigned a zone number. The scenes stored
in EDX devices can be recalled by ECP panels with the same zone number.
For example, EDX devices configured as zone 1 can be controlled (recall scenes) by
ECP panel configure as zone 1.
Figure 1: One EDX device with one ECP scene panel

ISO 9001 CERTIFIED www.liteputer.com.tw
Lite-Puter
ECP-110T[EUM-B]
5
2-1-2 Purpose of Zone Setting
The ECP-110T can control up to 8 zones at the same time. Before using it, be confirm
the zones controlled by each panel.
ECP-110T has 2 setting modes: panel setting and DIP setting.
DIP.10 (OFF): panel setting zone(2-1-3);
DIP.10 (ON): DIP setting zone (2-1-4).
ECP-110T has 2 control modes: single-zone mode or multi-zone mode.
DIP.9 (OFF): single-zone mode;
DIP.9 (ON): multi-zone mode.
2-1-3 Zone Setting
1.DIP 10(OFF) and hold【ZONE】, and then hold 【4】for 5 seconds till【▼】or 【▲】is flickering.
2. Keep holding 【ZONE】and release【4】.
3. By default, the backlight of 【1】is in red, which means the zone number is 1 no matter in single or
multi zone mode.
Zone setting Code
Single / multi-zone Code
Panel/DIP Code

ISO 9001 CERTIFIED www.liteputer.com.tw
Lite-Puter
ECP-110T[EUM-B]
6
4. Press 【1……6】, 【▲】, 【▼】to set zone number by following instructions:
Single-zone mode (DIP9: OFF):
Each button presents:
【1】= 1
【2】= 2
【3】= 4
【4】= 8
【5】= 16
【6】= 32
【▲】= 64
【▼】= 128
For example, to set zone number as “3” in single zone mode:
Press 【1】,【2】to make their backlight to red.
(
【
1
】
= 1,
【
2
】
= 2, 1+2= 3 )
For example, to set zone number as “130” in single zone mode:
Press 【2】,【▼】to make their backlight to red.
(
【
2
】
= 2,
【
▼
】
= 128, 2 + 128 = 130)

ISO 9001 CERTIFIED www.liteputer.com.tw
Lite-Puter
ECP-110T[EUM-B]
7
Multi-zone mode (DIP9: ON):
Each button presents:
【1】= zone 1
【2】= zone 2
【3】= zone 3
【4】= zone 4
【5】= zone 5
【6】= zone 6
【▲】= zone 7
【▼】= zone 8
For example, to set zone number to “1 and 2” (to control zone 1 and 2 at the same
time):
Press 【1】and 【2】to make their backlight to red.
For example, to set zone number to “2 and 8” (to control zone 2 and 8 at the same
time):
Press 【2】and 【▼】to make their backlight to red.

ISO 9001 CERTIFIED www.liteputer.com.tw
Lite-Puter
ECP-110T[EUM-B]
8
2-1-4 Zone Setting of DIP
The Function of DIP is as above.
Single-zone mode (DIP.9/OFF): DIP.1---DIP.8 set zone with binary, can set 1-255 zones.
Multi-zone mode (DIP.9/ON): DIP.1---DIP.8 means 1st---8th zone.
2-2 Scene Recall
Press【1】~【6】to recall corresponding scenes.
For example:press【1】to recall the SC1 and the backlighting of the button will be in
red.
Press【1】~【6】once: the scenes will be recalled with fade in effect.
Quick press【1】~【6】twice: the scenes will be directly recalled.
2-3 Fine Adjust Dimming Level
Press【▼】and 【▲】to fine adjust dimming level.
2-4 Lock/Unlock
1. Hold【ZONE】, and then hold 【1】for 5 seconds till【▼】or 【▲】is flickering.
Zone setting code
Digits
Single/multi-zone code
Panel/DIP option code

ISO 9001 CERTIFIED www.liteputer.com.tw
Lite-Puter
ECP-110T[EUM-B]
9
If
【
▲
】
is flickering, it means ECP-110T is locked
If
【
▼
】
is flickering, it means ECP-110T is unlocked.
2. Release【1】, keep pressing 【ZONE】
3. Press【▼】/【▲】to unlock / lock.
【▲】: Lock
【▼】: Unlock
2-5 IR Remote Control
ECP-110T can receive infrared signal from remote controller (IR-0501) to recall the
scenes and adjust dimming level.
1. Hold【ZONE】, and then hold 【2】for 5 seconds till【▼】or【▲】is flickering.
If
【
▲
】
is flickering, it means the IR receiver is enabled.
If
【
▼
】
is flickering, it means this IR receiver is disabled .
2. Release【2】, keep pressing 【ZONE】.
3. Press【▼】/【▲】to disable / enable IR receiver.
【▲】: Enable
【▼】: Disable

ISO 9001 CERTIFIED www.liteputer.com.tw
Lite-Puter
ECP-110T[EUM-B]
10
2-6 Dry Contact Inputs
The scene 1 will be recalled by actuating input 1.
The scene 2 will be recalled by actuating input 2.

ISO 9001 CERTIFIED www.liteputer.com.tw
Lite-Puter
ECP-110T[EUM-B]
11
Appendix: Binary Code Principal
ZONE
8 bit DIP
ZONE
8 bit DIP
ZONE
8 bit DIP
12345678
12345678
12345678
1
10000000
2
01000000
3
11000000
4
00100000
5
10100000
6
01100000
7
11100000
8
00010000
9
10010000
10
01010000
11
11010000
12
00110000
13
10110000
14
01110000
15
11110000
16
00001000
17
10001000
18
01001000
19
11001000
20
00101000
21
10101000
22
01101000
23
11010000
24
00011000
25
10011000
26
01011000
27
11011000
28
00111000
29
10111000
30
01111000
31
11111000
32
00000100
33
10000100
34
01000100
35
11000100
36
00100100
37
10100100
38
01100100
39
11100100
40
00010100
41
10010100
42
01010100
43
11010100
44
00110100
45
10110100
46
01110100
47
11110100
48
00001100
49
10001100
50
01001100
51
11001100
52
00101100
53
10101100
54
01101100
55
11101100
56
00011100
57
10011100
58
01011100
59
10011100
60
00111100
61
10111100
…
…
255
11111111
※0 = DIP/OFF; 1= DIP/ON.

ISO 9001 CERTIFIED www.liteputer.com.tw
Lite-Puter
ECP-110T[EUM-B]
12
Limited Warranty
1. Lite-Puter is only responsible for the product itself.
2. Lite-Puter guarantees to keep Lite-Puter’s from manufacturing defects
within a year since the distributing date.
3. Lite-Puter does not offer on-site service. If the defects appears
In Lite-Puter’s product, please deliver the product to local distributors or to Taipei
headquarters.
4. The warranty does not cover:
a. Any fault caused by false usage, imprudence (collision, inadequate installation or
adjustment, insufficient ventilation, or improper repairs)
b. Force majeure factors (flooding, earthquake, thunder, volcanic eruption, tsunami or
other factors beyond Lite-Puter control).
c. The cost of installing, reinstalling, adjusting, repairing, or reprogramming the
product.
d. Other products or devices which are offered by Lite-Puter or not by Lite-Puter.
5. Lite-Puter does not warrant the product will operate without interruption or being
free of error.
Revision Record
Issued: 2012/01
Version
Record
A
First issued
B
Add DIP function

ISO 9001 CERTIFIED www.liteputer.com.tw
Lite-Puter
ECP-110T[EUM-B]
13
World Headquarters:
Lite-Puter Enterprise Co., Ltd.
Address: 11F, No. 189, Gangqian Rd., Neihu Dist., Taipei City 11494, Taiwan.
Tel: +886-2-27998099
Fax: +886-2-27993828
Website: www.liteputer.com.tw
E-mail: sales@liteputer.com.tw
Shanghai Factory:
Lite-Puter Technology(Shanghai)Co.,Ltd.
Address: Building B5, No. 298, Lane 3509, Hongmei S. Road, Shanghai, China
Zip Code:201108
Tel: +86-21-54408210
Fax: +86-21-64978079
Table of contents
Other Lite-Puter Control Panel manuals
Popular Control Panel manuals by other brands

König Electronic
König Electronic SEC-DUMMYCP10 manual

Belden
Belden Hirschmann MIPP Description and Assembly Instructions

Viessmann
Viessmann VITODENS 200 Operating instructions and user's information manual

Intermatic
Intermatic P40000 Series Installation, operation & service manual

Jandy
Jandy AquaLink RS installation instructions

SJE Rhombus
SJE Rhombus 112 Installation Instructions and Operation