1.READ AND FOLLOW ALL
SAFETY INSTRUCTIONS
2. Before wiring to power supply, turn off electricity at fuse or
circuit breaker.
3. Disconnect AC power before servicing.
4. All servicing should be performed by qualified personnel.
5. Consult your local building code for approved wiring and
installation.
6. Do not use outdoors.
7. Do not mount near gas or electric heater.
8. Fixture must be grounded to avoid potential electric shock.
9. Equipment should be mounted in location and at heights where it will
not readily be subjected to tampering by unauthorized personnel.
10. The use of accessory equipment not recommended by the
manufacturer may cause an unsafe condition.
11. Do not use this equipment for other than intended use.
SAVE THESE INSTRUCTIONS
CAUTION: For safety and proper operation, read and follow instructions carefully before installation.
IMPORTANT SAFEGUARDS
INSTALLATION INSTRUCTIONS
EX (ELA CSUS12) or LQM (ELA LQMUS12)
EXIT SIGN STEM KIT
IMPORTANT NOTE:
1. Require the use of a 4" octagon junction box (not supplied) for mounting.
2. All exit sign electronics must be in the exit sign housing.
3. Note: Installation process is the same for both the EX and LQM exit signs, but the correct kit needs to be used
due to differences in the housing mounting brackets.
Refer to product instruction sheet for wiring diagrams, maintenance instructions and warranty information.
Parts Description
aPendant
bMounting Canopy
cUniversal Mounting Bracket
dScrew, 8-32 X 1 1/4"
eRetaining Washer
fPalnut
gUpper housing Bracket
hLower housing Bracket
iScrew, 8-18 x 1” PH type 25
a
b
c
d(qty. 2)
e(qty. 2)
f
f(qty. 2)
g
h
i(qty. 2)
h
Fig. B
Fig. A page 1

Installation: Pendant Mount
Note: Installation process is the same for both the
EX and LQM exit signs, but the correct kit needs
to be used due to differences in the housing
mounting brackets.
1. Attach screws dto mounting canopy busing retainer
washers e.
2. Thread palnut fonto one end of pendant athe complete
length of the thread. Next feed upper mounting bracket g
onto same threaded end and secure with 2nd palnut f.
(See figure B for bracket orientation).
3. Thread canopy bonto opposite end of pendant aand
secure with palnut f. Palnut can be loosened to allow
turn of pendant for proper Exit orientation.
4. Make wire voltage selection and connect wires using
pushnut connections to pendant input wires inside of unit.
Route opposite end of pendant input wires (not supplied)
through housing wireway and out through the housing top
opening.
5. Route pendant input wires through pendant at lower
housing bracket hend (see Fig. B).
6. Attach pendant assembly to Exit sign using lower housing
bracket hand (2) screws i. Do not over-tighten. (see
Fig. C)
7. Attach universal mounting bracket cto 4” octagonal j-
box.
Position canopy end and make input wire connection.
8. Align canopy screws dto universal mounting bracket c
and tighten until rear side of canopy is flush with ceiling
surface.
Attachment to Exit Housing
Fig. C
Attachment to Mounting Canopy
(Note: J-Box bracket shown un-attached
to J-box for clarity).
Fig. D
page 2

READ AND FOLLOW ALL SAFETY INSTRUCTIONS!
SAVE THESE INSTRUCTIONSAND DELIVER TO OWNER AFTER INSTALLATION
·To reduce the risk of death, personal injury or property damage from fire, electric shock, falling parts, cuts/abrasions, and
other hazards please read all warnings and instructions included with and on the fixture box and all fixture labels.
·Before installing, servicing, or performing routine maintenance upon this equipment, follow these general precautions.
·Installation and service of luminaires should be performed by a qualified licensed electrician.
·Maintenance of the luminaires should be performed by person(s) familiar with the luminaires’ construction and operation
and any hazards involved. Regular fixture maintenance programs are recommended.
·It will occasionally be necessary to clean the outside of the refractor/lens. Frequency of cleaning will depend on ambient
dirt level and minimum light output which is acceptable to user. Refractor/lens should be washed in a solution of warm
water and any mild, non-abrasive household detergent, rinsed with clean water and wiped dry. Should optical assembly
become dirty on the inside, wipe refractor/lens and clean in above manner, replacing damaged gaskets as necessary.
·DO NOT INSTALL DAMAGED PRODUCT! This luminaire has been properly packed so that no parts should have been
damaged during transit. Inspect to confirm. Any part damaged or broken during or after assembly should be replaced.
·Recycle: For information on how to recycle LED electronic products, please visit www.epa.gov.
·These instructions do not purport to cover all details or variations in equipment nor to provide every possible contingency
to meet in connection with installation, operation, or maintenance. Should further information be desired or should
particular problems arise which are not covered sufficiently for the purchaser’s or owner’s purposes, this matter should be
referred to Acuity Brands Lighting, Inc.
WARNINGS
RISK OF BURN
üAllow lamp/fixture to cool before handling. Do not touch enclosure or light source.
üDo not exceed maximum wattage marked on luminaire label.
üFollow all manufacturer’s warnings, recommendations and restrictions for: driver type, burning position, mounting
locations/methods, replacement and recycling.
CAUTIONS
RISK OF INJURY
üWear gloves and safety glasses at all times when removing luminaire from carton, installing, servicing or performing
maintenance.
üAvoid direct eye exposure to the light source while it is on.
RISK OF ELECTRIC SHOCK
üDisconnect or turn off power before installation or servicing.
üVerify that supply voltage is correct by comparing it with the luminaire label information.
üMake all electrical and grounded connections in accordance with the National Electrical Code (NEC) and any applicable local
code requirements.
üAll wiring connections should be capped with UL approved recognized wire connectors.
RISK OF FIRE
üKeep combustible and other materials that can burn, away from lamp/lens.
üDo not operate in close proximity to persons, combustible materials or substances affected by heat or drying.
RISK OF FIRE
üNever connect components under load.
üDo not mount or support these fixtures in a manner that can cut the outer jacket or damage wire insulation.
üUnless individual product specifications deem otherwise: Never connect an LED product directly to a dimmer packs,
occupancy sensors, timing devices, or other related control devices. LED fixtures must be powered directly off a switched
circuit.
üUnless individual product specifications deem otherwise: Do not restrict fixture ventilation. Allow for some volume of
airspace around fixture. Avoid covering LED fixtures with insulation, foam, or other material that will prevent convection or
conduction cooling.
üUnless individual product specifications deem otherwise: Do not exceed fixtures maximum ambient temperature.
üOnly use fixture in its intended location.
üLED products are Polarity Sensitive. Ensure proper Polarity before installation.
üElectrostatic Discharge (ESD): ESD can damage LED fixtures. Personal grounding equipment must be worn during all
installation or servicing of the unit.
üDo not touch individual electrical components as this can cause ESD, shorten lamp life, or alter performance.
üSome components inside the fixture may not be serviceable. In the unlikely event your unit may require service, stop using
the unit immediately and contact an ABL representative for assistance.
üAlways read the fixtures complete installation instructions prior to installation for any additional fixture specific warnings.
page 3

EMCSA00791
Rev A
page 4
ONE LITHONIA WAY, CONYERS, GEORGIA 30012 PHONE: 770 922-9000 www.lithonia.com