Livoo DOM427N User manual

Instructions for use
WWW.LIVOO.FR
Référence : DOM427N
Version : 1.4
Langue : Eng ish
E ectronic Bathroom Sca e

Instructions for use
1
You have purchased a product LIVOO brand and we thank you. We take great care in design, ergonomics
and ease of use of our products. We hope that this product wi give you comp ete satisfaction.
This instruction manua is a so avai ab e on our website www. ivoo.fr
READ ALL THESE INSTRUCTIONS CAREFULLY BEFORE USING THE APPLIANCE AND SAVE THEM FOR
FUTURE USE.
SAFETY INSTRUCTIONS
PLEASE TAKE THE TIME TO READ THE OPERATING INSTRUCTIONS
CAREFULLY BEFORE USING THE PRODUCT FOR THE FIRST TIME.
Improper use of the device can damage it or injure the user.
Make sure that you use the device for the purpose for which it
was designed; we accept no iabi ity for damage (compensation)
due to incorrect use or mishand ing.
1. This app iance is intended for domestic use on y. Any other use
(medica , professiona , commercia , etc.) is exc uded.
2. Chi dren shou d be supervised to ensure that they do not p ay
with the app iance.
3. Keep this app iance indoors and in a dry p ace.
4. Do not immerse the unit in water or any other iquid.
5. Do not store any objects on the sca e.
6. To avoid risk of injury, do not stand on the edges of the sca e.
7. To prevent s ipping, make sure that your feet and the sca e are
dry and free of dust before getting on the sca e.
8. Do not disassemb e the sca e.
9. Avoid strong vibrations or shocks, such as dropping the sca e on
the f oor.

Instructions for use
2
10. A ways p ace your sca e on a hard, eve surface. Avoid carpets
and rugs.
11. Do not use the sca e on a s ippery surface or on a wet f oor.
12. Keep the sca e away from heat sources (radiators, etc.) to avoid
deformation of p astic parts.
13. Do not store the sca e in an upright position.
14. Use on y the type of battery specified in this manua .
15. Rep ace the batteries when they are worn out or eak.
16. Remove the batteries if the app iance is not used for a ong
period of time.
17. Do not disassemb e the sca e as improper hand ing may resu t in
injury to persons or damage to the sca e.
Key features
•High-precision strain gauge sensor system
that guarantees the most accurate resu ts
•Tempered g ass p atform
•Capacity: 5kg-180kg / Age : 10 – 99 years
o d / Size : 100 – 240 cm
•Division: 0.1kg
•LCD screen
•Automatic power on and off
•Low battery and over oad indicator
•Switch with three different units: kg/ b/st
•1 CR2032 ithium battery.
•CR2032 in the compartment (observing
po arity), then c ose the compartment
cover.
To change the batteries, open the cover at the back, p ace 1 ithium battery (CR2032) in the battery
compartment and insert the battery cover.
Disclaimer / arning :
1. To ensure accuracy, we suggest you take measurement at a fixed time every day, before breakfast (e.g.
6:00am-8:00am)
2. P ease change a new battery when “LO” appears on the LCD which indicates that the battery is out of
power.
3. “Err” showed on LCD indicates over oad.
Attention
1. P ease take off shoes before taking measurement to avoid scraping or scratching the g ass p atform.

Instructions for use
1
2. The g ass p atform may be pretty s ippery when wet, thus p ease make sure both the g ass and your feet
are dry before using.
3. P ease use soft tissue with a coho or g ass c eaner to c ean the surface if it is dirty. No soap or other
chemica s. Keep it away from water, heat and extreme co dness.
4. The sca e is high precision measuring device. Never jump or stomp on the sca e or disassemb e it. Be
carefu not to drop or jar the sca e.
5. The sca e is for fami y use on y and not suitab e for professiona s.
6. P ease check the battery if the sca e ma functions. Rep ace the battery when necessary. For other
prob ems, p ease contact the oca dea er or our company direct y by phone or e-mai .
Overview
1 : SET key: to access the parameters, save data and access the saved data.
2 : UNIT key: to change the unit of measurement
3 : "▲" or "▼" keys: to se ect the memory, reduce and increase the disp ayed data
4 : Sensors
5 : Weighing surface
6 : Battery compartment at the back of the sca e.
2
1
3
4
5
6

Instructions for use
2
Indicators
Different indicators:
•Weight
•Body Fat in %.
•Moisture content in %.
•Musc e mass in %.
•Bone mass in %.
•Energy requirement in ca ories (kca )
•BMI (Body Mass Index)
The sca e has a tota of 13 profi es in memory.
USING YOUR APPLIANCE
Remove the battery from the package and turn the sca e over, open the cover, insta the battery in the
compartment and rep ace the cover (make sure the positive battery termina is facing up).
P ace the sca e on a f at, stab e surface. A c ean and dry f oor is idea . Do not p ace the sca e on a carpet.
When you step on the sca e and the disp ay shows "0.0", press "UNIT" to se ect the unit (kg, st, b).
Measurements are made using the oad ce s insta ed on the weighing surface:
- The e ectricity sent by the sensors circu ates free y through the iquid surrounding your musc es,
which is how the musc e mass is ca cu ated.
- In the case of greasy mass, e ectricity offers a stronger resistance. This resistance is measured.
Setting and storing persona data in memory
Stand brief y on the sca e to app y s ight pressure. Once the disp ay shows "0.0" and the unit of measure is
set to "kg" or " b" as desired, the setting can begin.
If you wish to weigh without a body scan, you do not need to enter your persona data.
1. Settings personnal informations
1.1 Press the "set" button. Use the arrows on the side of the disp ay "▲"or "▼" to se ect your
persona profi e between P01-P13. Once you have chosen your profi e number, press the "SET" button to
confirm.
1.2 Press "▲" or "▼" to se ect Ma e or Fema e and press "SET" to confirm.
1.3 The age preset is disp ayed: 20. Press "▲"or "▼" to choose your age (10-99), press "SET" to
confirm.
1.4 The size preset is disp ayed: 165. Press "▲" or "▼" to choose your size (100-240), press "SET" to
confirm.

Instructions for use
3
1.5 When the settings are comp ete, the se ected information scro s quick y on the disp ay.
1.6 To start measuring, wait unti the disp ay shows "0.0" again.
2. Take the weight hydration and body fat percentage.
The ana ysis wi on y be ab e to work once your persona data has been saved (previous chapter).
2.1 Brief y c imb onto the sca e to app y s ight pressure. Once the disp ay shows "0.0", press "SET"
and use the "▲"or "▼" keys to se ect your profi e.
2.2 The data wi be disp ayed brief y and then "0.0" wi be disp ayed.
2.3 Stand barefoot on the unit whi e maintaining contact with the e ectrodes. There shou d be no
contact between your feet, to avoid an erroneous measurement. Stand sti but do not ho d yourse f.
2.4 Even after the weight is disp ayed continue to stand sti .
"Lo" on the disp ay indicates that the battery is ow. You must rep ace the battery. The data you have stored
wi not be erased.
The "Err" message indicates an over oad, or an error in measuring the percentage of fat. Do not eave the
sca e during measurement.
If the body fat percentage is ess than 5%, the disp ay shows "Er".

Instructions for use
4
Disposal of batteries and accumulators (Applicable in the European Union countries and in the other European countries
having systems of selective collection)
This symbo , affixed on batteries and accumu ators or on packaging, indicates that batteries and accumu ators
supp ied with this product must not be treated as simp e househo d waste.
By assuring you that these batteries and accumu ators are discarded in a appropriate way, you participate
active y in the prevention of the negative consequences which their i -treatment cou d cause on the
environment and on the human hea th. The recyc ing of materia s contributes besides to the conservation of
natura resources.
For the products, which, for safety reasons, of performance or integrity of data require a permanent connection in a battery or
in an accumu ator, it wi be advisab e to move c oser you to check with technica service qua ified to make its rep acement.
By bringing back your e ectric device at the end of ife to an appropriate point of co ection you make sure that the battery or the
incorporated accumu ator wi be correct y treated.
For a other scenarios and to remove battery or accumu ators in comp ete safety of your app iance, refer to the user manua .
Bring back batteries or worn accumu ators to the point of co ection suited for the recyc ing.
For any further information about the recyc ing of this product or batteries and accumu ators, you can contact your municipa ity,
your oca waste reception center or the point of sa e where you bought this product.
Disposal of this product
( aste Electrical & Electronic Equipment)
(Applicable in the European Union and other European countries with separate collection systems)
The European Directive 2012/19/EU on Waste Faci ities E ectrica and E ectronic (WEEE)
This marking shown on the product or its iterature, indicates that it shou d not be disposed with other househo d
wastes at the end of its working ife.
To prevent possib e harm to the environment or human hea th from uncontro ed waste disposa , p ease separate this from other
types of wastes and recyc e it responsib y to promote the sustainab e reuse of materia resources.
Househo d users shou d contact either the retai er where they purchased this product or their oca authority office, for detai s of
where and how they can take this item for environmenta y safe recyc ing.
•Non contractua i ustration
•Product information is subject to change without prior notice
LIVOO
BP 61071
67452 Mundolsheim - FRANCE
Table of contents
Other Livoo Scale manuals