15-17 Futura Road, Keysborough, 3173
Melbourne Victoria Australia
T: 61 3 9798 1322 F: 61 3 9798 9652
www.lockfocus.com.au
FREE PHONE: 1800 687 116
Email: [email protected]
Sliding Door Lock
Available in two variants: D Pull
Handle and Slimline Handle.
APPLICATION
• Aluminium & timber sliding doors
• Surface mounted
FEATURES
• Twin locking hooks
• Anti-slam feature prevents damage
to locking hooks
• Easy to operate sliding snib
• Non-handed design
KEYING
• Available in C4 & disc cylinder
FIXING
• Concealed screw fixing
• Standard 82mm hole spacing
MATERIALS
Constructed from engineered composite
materials with pressed metal and high
pressure die cast parts where maximum
strength and durability is required.
DESIGN
Sleek and stylish, the Lock Focus D Pull
Handle strikes the right balance of curves
and sharp lines, to suit modern interior’s.
The Slimline Handle provides maximum
comfort, while maintaining a clean, slender
look for your sliding door.
D Pull Handle
Slimline Handle
SLIDING DOOR LOCK tailered locking solutions
PACK CONTENTS
slim full
Cover mounting screws
(25mm CSK plastic screws)
Spacer
(doubles as template)
Base assembly
Base mounting
screws
(2 sets supplied for different
door thicknesses)
(Cover options)
Strike base
Strike cover
mounting screw
(5mm CSK
taptite screw)
Strike cover
Strike mounting screws
(20mm pan-flange
self drilling screws)
Cylinder
Outside cylinder
with Locking bar
Cylinder guide
Outside cover
1a. SURFACE MOUNT 1b. SIDE MOUNT
MOUNTING TEMPLATE AND SPACER
2. MOUNTING OUTSIDE COVER
AND CYLINDER ASSEMBLY
• Close door completely
• Place template at desired height
- ensure the front of the template
is hard up against the door
frame. Either hold the template
in pace or use the provided
double sided adhesive tape
• Drill all three holes labelled ‘A’ at
8mm as illustrated
• If the mounting surface between
the door and the door frame is
more than 4mm you will need to
use the spacer, if not, you will
need to remove it
• Close door completely
• Place template at desired height
- ensure the front of the template
is a measured 20mm from the
frame edge. Either hold the
template in pace or use the
provided double sided
adhesive tape
• Drill all three holes labelled ‘A’ at
8mm as illustrated
• If the mounting surface between
the door and the door frame is
more than 4mm you will need to
use the spacer, if not, you will
need to remove it
• Assemble outside cover components as shown - note the
orientation of the components
• Press assembly through from the outside as shown -
note orientation of assembly to door
• With assembly pressed firmly in place, measure the
Locking bar protrusion and trim to 8-10mm from inside
face of door as shown
• Once the Locking bar has been trimmed to length, file
the ends smooth and round the corners
A
A
AA
Flush with frame (door closed)
20mm
20mm from frame edge
(door closed)
Standard 82mm hole spacing
8-10mm
(10mm MAX)
= 8mm hole
FEATURES
• Twin locking hooks
• Anti-slam feature prevents damage to locking hooks
• Easy to operate sliding snib
• Non-handed design
KEYING
• Available in C4 & disc cylinder
FIXING
• Concealed screw fixing
• Standard 82mm hole spacing
MATERIALS
Constructed from engineered composite materials with pressed metal and
high pressure die cast parts where maximum strength and durability is
required.
DESIGN
Sleek and stylish, the Lock Focus euclid full strikes the right balance of
curves and sharp lines, to suit modern interior’s. The euclid slim
provides maximum comfort, while maintaining a clean, slender look for
sliding door applications.
3. MOUNT BASE ASSEMBLY 4a. FLUSH MOUNT STRIKE TO DOOR FRAME
4b. SIDE MOUNT STRIKE TO DOOR FRAME 5. ATTACH COVER AND CYLINDER
6. ADDITIONAL FASTENING
7. CHECK OPERATION OF LOCK
• Select the correct fixing screws
based on diagram
• Place Base assembly on door
lining up the mounting holes and
Locking bar
• Fasten screws into the bosses
on the Outside cover. Tighten
evenly ensuring the lock stays
plum
• If the mounting surface between
the door and the door frame is
more than 4mm you will need to
use the spacer
• Determine which
cover you are going to
use - euclid full or
euclid slim
• Insert Cylinder into
Cover (it can only fit
one way)
• Open the door and
withdraw the locking
hooks in the Base
assembly
• Place the Cover over
the assembly - push
back on the spring
loaded ‘anti-slam’
safety device with a
screw driver to seat
the Cover correctly
• Fasten down the cover
using the two provided
25mm CSK plastic
screws. WARNING:
Do not over tighten
• With the door fully closed, place the Strike base on the door frame and
mate up to Base assembly - locating the tabs as shown
• Back off the Strike base from the Base assembly approximately 2mm
as shown
• Mark hole centres in the midle of the two mounting slots on the Strike
base, or simply drill a 3mm pilot hole while holding in place
• Fasten down the Strike base with the provided 20mm pan-flange self
drilling screws
• Attach Strike cover with provided 5mm CSK taptite screw
• Check to see if the lock is fastened well. A small
amount of ‘freeplay’ is nessecary for the lock to
operate but if there is excesive ‘slop’ in the
directions illustrated you may wish to use the
additional fastening locations
• Remove the Cover and Cylinder
• Slide the lock into the locked position with locking
hooks extended - this reveals the addtional two
fastening holes that can be used
• Screw through the Base assembly and into the
door frame (using the provided countersunk, self
drilling M5 screws). WARNING: Do not over
tighten - hand tightening recomended
• Unlock and lock using snib lever - check for smooth operation and that the locking
hooks engage correctly
• Unlock and lock using the key from the inside and the outside. Try locking from the
inside using snib lever and then unlocking from outside using key
• If the lock is not operating as it should, try adjusting the position of the Strike
assembly. If it is something else, please free phone LockFocus on 1800 687 116
• Create Strike assembly by attaching
the Strike cover to the Strike base
with the provided 5mm CSK taptite
screw as shown
• With the door fully closed, place the
Strike assembly over the locating lugs
on the Base assembly and press
firmly against door
• Mark a line on the door frame along
the top edge of the Strike assembly
making sure it is level (‘Z’). Mark
another line above and below the
Strike assembly along the edge where
the door meets the frame (’Y’)
• Pre-drill two 3mm pilot holes through
the two diecast mounting tabs at the
back of the Strike assembly as shown
in the diagram. Drill through Strike
cover as well - it is critical for fitment
that these holes line up well
• With the door open, place the Strike
assembly on the door frame so that it
falls in the lines drawn on the frame
• Fasten down Strike assembly through
pilot holes with provided 20mm
pan-flange self drilling screws
Use spacer if offset is greater
than 4mm
Use the 65mm
Stainless finish
screw for door
thicknesses of
between
28-48mm
Use the 40mm
black finish
screw for door
thicknesses of
between
15-27mm
’Y’
’Y’
’Y’
’Y’
’Z’ ’Z’
’Y’
’Y’
Diecast mounting tabs
Additional fixing
points
Push back to
get Cover on
Mark centre or
drill 3mm pilot hole
in place
’Z’
x
Allow 2mm gap here
top and bottom

This manual suits for next models

1

Popular Door Lock manuals by other brands

Assa Abloy Corbin Russwin ED3400 Series installation instructions

Assa Abloy

Assa Abloy Corbin Russwin ED3400 Series installation instructions

Assa Abloy Sargent PE8893 installation instructions

Assa Abloy

Assa Abloy Sargent PE8893 installation instructions

Assa Abloy Corbin Russwin ED5800 Series installation instructions

Assa Abloy

Assa Abloy Corbin Russwin ED5800 Series installation instructions

danalock V3 SCANDI Easy install

danalock

danalock V3 SCANDI Easy install

Kaba E30 quick guide

Kaba

Kaba E30 quick guide

Kwikset 159 installation guide

Kwikset

Kwikset 159 installation guide

Ilockey ID9105FMT-S Manual operation guide

Ilockey

Ilockey ID9105FMT-S Manual operation guide

Omnio FG121 Series manual

Omnio

Omnio FG121 Series manual

NetworX Architech Mounting and installation instructions

NetworX

NetworX Architech Mounting and installation instructions

GATEMAN YDM4109 user guide

GATEMAN

GATEMAN YDM4109 user guide

Assa Abloy MSL mFlipLock basis Assembly and operating instructions

Assa Abloy

Assa Abloy MSL mFlipLock basis Assembly and operating instructions

Siegenia KFV BS 2100 Assembly instructions

Siegenia

Siegenia KFV BS 2100 Assembly instructions

Commax CDL-200P user manual

Commax

Commax CDL-200P user manual

SECO-LARM SD-997SMB-AQ installation manual

SECO-LARM

SECO-LARM SD-997SMB-AQ installation manual

Samsung SHS-1321 instruction manual

Samsung

Samsung SHS-1321 instruction manual

Yale Code Handle 8830 Fitting and operating instructions

Yale

Yale Code Handle 8830 Fitting and operating instructions

CODELOCKS KL1000 G3 NetCode Programming and operating instructions

CODELOCKS

CODELOCKS KL1000 G3 NetCode Programming and operating instructions

tell CL600 Code change guide

tell

tell CL600 Code change guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.