Loevschall A/S, Nikkelvej 11, DK-8940 Randers SV. http://www.loevschall.dk
IM-0225 Rev0
[EN]
Instruction for the use of the LED driver
Model: ECO15-12V
Please read the instructions thoroughly before installing.
Applications
The electronic LED converter ECO15-12V is exclusively designed to power LED lamps
used indoor. The driver will switch off in the case of short circuit, open circuit and/or
overheating (operating temperature range -20°C to +45°C). The driver will
automatically reset and restart after an error correction.
The driver should always be connected to LED light(s) between 1-15W.
Important information for the installation
The driver conforms to the directive 2014/30/EU for the electromagnetic
compatibility and the low voltage directive 2014/35/EU.
•Power must be disconnected from mains voltage when
connecting or disconnecting the spots.
•The driver should be installed by a qualified electrician.
•Always connect the LED lamps to the LED driver with correct polarity
according to the schematic drawing.
•Loevschall A/S recommends that the maximum length of the cable to
the LED lamps do not exceed 1.5m in order to meet the EMC standard.
•The maximum wattage of the lights being connected should not exceed
a total of 15W. The minimum wattage of the lights being connected
should exceed 1W.
•If the driver is used for other purposes than originally intended or is
connected incorrectly no liability for possible damages can be claimed
towards Loevschall A/S.
Specifications:
Minimum load: 1W
Maximum load: 15W
Input voltage: 220V-240V~ 50Hz
Output voltage: 12Vdc
Rated power: 15W
Protection degree: IP20
Ambient temperature ta: Max. 45°C
Case temperature tc: Max. 85°C
[DK]
Instruktion til anvendelse af LED driver
Model: ECO15-12V
Læs venligst denne instruktion før driveren installeres.
Anvendelse
LED driver ECO15-12V er udelukkende designet til LED-lamper, der anvendes
indendørs. Driveren vil slukke i tilfælde af kortslutning på sekundær siden, manglende
belastning og/eller overophedning (tilladt driftstemperatur fra -20°C til +45°C).
Driveren vil automatisk nulstille og genstarte efter en fejl er udbedret. Driveren skal
altid være tilsluttet LED lamper med en effekt mellem 1-15W.
Vigtig information vedr. installation
Driveren er i overensstemmelse med direktivet 2014/30/EUfor elektromagnetisk
kompatibilitet og lavspændingsdirektivet 2014/35/EU.
•Strømmen skal være afbrudt inden tilslutning og frakobling af
spots.
•Driveren bør installeres af autoriseret El-installatør.
•Tilslut LED lamperne til den elektroniske driver med korrekt polaritet i
henhold til den skematiske tegning.
•Loevschall A/S anbefaler at kablet til LED-lamper ikke er længere end
1.5m iht. EMC standard.
•Den maksimale wattage for alle tilsluttede lamper må ikke overstige
15W totalt. Den minimale effekt for alle tilsluttede lamper bør overstige
1W.
•Hvis driveren anvendes til andre formål end oprindeligt beregnet eller er
forkert tilsluttet, fraskiver Loevschall A/S sig ethvert ansvar for
eventuelle skader.
Specifikationer:
Minimum belastning: 1W
Maximum belastning: 15W
Indgangsspænding: 220V-240V~ 50Hz
Udgangsspænding: 12Vdc
Mærkeeffekt: 15W
Beskyttelsesklasse: IP20
Omgivelsestemperatur ta: Max. 45°C
Case temparature tc: Max. 85°C
[S]
Instruktion för användande av LED driver
Model: ECO15-12V
Läs instruktionerna noga innan installation.
Tillämpning
Den elektroniska LED konverter ECO15-12V är endast avsedd för att driva LED-lampor
som används inomhus. Drivern stängs vid kortslutning, öppen krets och/eller
överhettning (driftstemperaturområde -20°C till +45°C). Drivern återställs
automatiskt och starta efter att felet är korrigerat. Drivern ska alltid anslutas till LED-
spot(s) mellan 1-15W.
Viktig information för installation
Drivern är förenlig med direktivet 2014/30/EU om EMC och LVD, direktiv
2014/35/EU.
•Ström måste kopplas bort från nätspänningen när du ansluter
eller kopplar ifrån LED lampor
•Drivern bör installeras av en kvalificerad person
•Anslut alltid LED-lampor till LED driver med rätt polaritet enligt
schematisk ritning.
•Loevschall A/S rekommenderar att den maximala längden av kabeln till
LED-lampor inte överstiga 1.5m för att möta EMC-standarden.
•Den maximala effekten av lamporna som är anslutna bör inte överstiga
totalt 15W. Det minimala wattantal av lamporna som är anslutna ska
överstiga 1W.
•Om Drivern används för andra ändamål än den är avsedd för eller är
felaktigt ansluten, ansvarar inte Loevschall A/S för eventuella skador.
Specifikationer:
Minsta belastning: 1W
Maxlast: 15W
Inspänning: 220V-240V ~ 50Hz
Utgångsspänning: 12V
Märkeffekt: 15W
Skyddsklass: IP20
Omgivningstemperatur ta: Max. 45°C
Case Temperatur tc: Max. 85°C
Loevschall A/S, Nikkelvej 11, DK-8940 Randers SV. http://www.loevschall.dk
IM-0225 Rev0
[N]
Instruksjon for bruk av LED trafo
Model: ECO15-12V
Les instruksjonene nøye før installasjon.
Bruken
Den elektroniske LED konverter ECO15-12V er bare tenkt til bruk sammen med LED
lamper som brukes innendørs.
Trafoen vil kutte ut ved kortslutning, åpen krets og/eller overoppheting.
(driftstemperaturområde -20°C til +45°C). Trafoen tilbakestilles automatisk og starter
etter at feilen er utbedret.
Trafoen skal alltid tilsluttes til LED-spot(s) mellom 1-15W.
Viktig informasjon for installasjon
Trafoen er tilpasset direktivet 2014/30/EU om EMC og LVD, direktiv 2014/35/EU.
•Strømmen må være frakoblet når du tilslutter eller kobler ifra
LED lysene.
•Trafoen bør installeres av en godkjent EL-intallatør
•Tilslutt alltid LED lysene til LED trafo med rett polaritet ihht. skjematisk
tegning.
•Loevschall A/S anbefaler at den maksimale lengden på kabelen til LED
lysene ikke overstiger 1.5 meter for å imøtekomme EMC-standarden.
•Den maksimale effekten av lampene som er tilsluttet bør ikke overstige
totalt 15W. Det minste wattantallet av lampene som er tilsluttet skal
overstige 1W.
•Om trafoen benyttes til andre formål enn beskrevet, eller er feil
tilkoblet, tar ikke Loevschall A/S ansvar for eventuelle skader.
Spesifikasjoner:
Minste belastning: 1W
Maxbellast: 15W
Spenning: 220V-240V ~ 50Hz
Utgangsspenning: 12Vdc
Effekt: 15W
Ipklasse: IP20
Omgivningstemperatur ta: Max. 45°C
Case Temperatur tc: Max. 85°C
[F]
Instructions d'utilisation du driver LED
Modèle : ECO15-12V
S'il vous plaît lire attentivement les instructions avant de l'installer.
Application
Le LED driver ECO15-12V est exclusivement conçu pour alimenter des lampes LED
utilisées en intérieur. Le driver s'éteint en cas de court-circuit, d'ouverture de circuit
et/ou de surchauffe (gamme de température de fonctionnement: -20°C à +45°C). Le
driver se réinitialise automatiquement et redémarre après la correction des erreurs. Le
driver doit toujours être connecté à LED avec une puissance totale de 1-15W.
Informations importantes concernant l'installation
Le driver est en conformité avec la directive 2014/30/EU pour la EMC et la directive
basse tension 2014/35/EU.
•L'alimentation doit être débranché de l'alimentation secteur
avant de brancher ou de débrancher les taches.
•Le convertisseur électronique doit être installé par un électricien
qualifié.
•Raccordez toujours les lampes LED au driver LED en veillant à respecter
la polarité conformément au schéma.
•Loevschall A/S recommande, que le câble pour les lampes à LED ne
dépassant pas 1.5m norme EMC.
•La puissance maximale de la lumière étant connectés ne doit pas
dépasser un total de 15W. La puissance minimale des lumières étant
connectés devrait dépasser 1W.
•Loevschall A/S décline toute responsabilité en cas d'utilisation du
convertisseur LED électronique à d'autres fins que celles initialement
prévues ou de raccordement incorrect.
Spécifications:
Charge minimale: 1W
Charge maximale : 15W
Tension d'entrée: 220V-240V~ 50Hz
Courant de sortie: 12Vdc
Puissance nominale: 15W
Classe de protection: IP20
Température ambiante ta: Max. 45°C
Température du boîtier tc: Max. 85°C
[EN] Power must be turned off before installing the
product.
The product shall be installed according to local
rules/guide lines. If in doubt, please contact a
certified electrician.
[DK] Strømmen skal afbrydes inden installation af
produktet.
Produktet skal installeres efter lokale
regler/retningslinjer. Hvis der er tvivl, så kontakt en
autoriseret el-installatør.
[SE] Ström måste stängas av för att installera produkten.
Produkten måste installeras efter lokala
regler/riktlinjer. Om du är tvivel, kontakta en
auktoriserad elektriker.
[NO] Strømmen må slås av for å installera produktet.
Produktet må installeres etter lokale
regler/retningslinjer. Er du i tvil, ta kontakt med en
kvalifisert elektriker.
[FI] Virta on sammutettu asentamiseen telineeseen.
Valaisin on asennettava paikallisten
sääntöjen/suuntaviivojen. Jos olet epävarma, ota
yhteys pätevään sähköasentajaan.

Other Loevschall Lighting Equipment manuals

Loevschall F15-350E User manual

Loevschall

Loevschall F15-350E User manual

Loevschall SNP15-12VL Technical manual

Loevschall

Loevschall SNP15-12VL Technical manual

Loevschall 3423100089/186 User manual

Loevschall

Loevschall 3423100089/186 User manual

Loevschall 15-12D User manual

Loevschall

Loevschall 15-12D User manual

Loevschall 14-320D-IP44 User manual

Loevschall

Loevschall 14-320D-IP44 User manual

Loevschall F15-350 User manual

Loevschall

Loevschall F15-350 User manual

Popular Lighting Equipment manuals by other brands

Life 39.9F70020C quick start guide

Life

Life 39.9F70020C quick start guide

EuroLite LED ML-20 user manual

EuroLite

EuroLite LED ML-20 user manual

LIGMAN OD-50141 installation manual

LIGMAN

LIGMAN OD-50141 installation manual

Home Accents Holiday 1002461144 instructions

Home Accents Holiday

Home Accents Holiday 1002461144 instructions

Experia IRiS Ripple Light instruction manual

Experia

Experia IRiS Ripple Light instruction manual

Erco Gecko Mounting instructions

Erco

Erco Gecko Mounting instructions

Inter-lux ZTA.100.Surface Installation and maintenance instructions

Inter-lux

Inter-lux ZTA.100.Surface Installation and maintenance instructions

Whelen Engineering Company TN Series installation guide

Whelen Engineering Company

Whelen Engineering Company TN Series installation guide

IKEA BJÖRKSPIREA manual

IKEA

IKEA BJÖRKSPIREA manual

Toolland PM 6640 instruction manual

Toolland

Toolland PM 6640 instruction manual

GTD GTD-LP200 user manual

GTD

GTD GTD-LP200 user manual

LIVARNO home 1105-W-UK manual

LIVARNO home

LIVARNO home 1105-W-UK manual

ProLights EclPar IPMFC user manual

ProLights

ProLights EclPar IPMFC user manual

Velvet EVO Series user manual

Velvet

Velvet EVO Series user manual

IDTOLIGHT GENT installation instructions

IDTOLIGHT

IDTOLIGHT GENT installation instructions

MAYTONI S35 installation manual

MAYTONI

MAYTONI S35 installation manual

MaxLite MLFP14DP4535 user manual

MaxLite

MaxLite MLFP14DP4535 user manual

SLV Elektronik 550621 instruction manual

SLV Elektronik

SLV Elektronik 550621 instruction manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.