LOGICDATA DYNAMIC MOTION DMUI-HSM User manual

DYNAMIC MOTION system
PART
OF
DYNAMIC MOTION
DMUI-HSM
User Manual
DOCUMENT VERSION 1.0 | JANUARY 2020

DMUI-HSM - MANUAL // PAGE 2
DMUI-HSM - Operating Manual
Document Version 1.0/January 2020
This document was originally published in English.
LOGICDATA Electronic & Software Entwicklungs GmbH
Wirtschaftspark 18
8530 Deutschlandsberg
Austria
Phone: +43 (0) 3462 51 98 0
Fax: +43 (0) 3462 51 98 1030
Internet: http://www.logicdata.net
Email: o[email protected]

DMUI-HSM - MANUAL // PAGE 3
CONTENTS
1 General information 4
1.1 Other applicable documents 4
1.2 Copyright 4
1.3 Royalty-free use of images and text 4
1.4 Trademarks 4
2Safety 5
2.1 Target audience 5
2.2 General safety regulations and obligations 5
2.3 Intended use 5
2.4 Reasonably foreseeable misuse 5
2.5 Explanation of symbols and signal words 6
2.6 Liability 6
2.7 Residual risks 7
2.8 Skilled Persons 7
2.9 Notes for Resellers 8
3 Scope of delivery 8
4Unpackaging 8
5 Product 9
5.1 Key Product Features 9
5.2 Dimensions 10
5.3 Drilling Template 11
6 Assembly 12
6.1 Safety During Assembly 12
6.2 Required Components 13
6.3 Process 13
6.4 Completing Assembly 13
7 System Information 14
8 Operation 15
8.1 Adjusting the Table Top Height 15
9 Additional Information 16
9.1 Disassembly 16
9.2 Maintenance 16
9.2.1 Cleaning 16
9.3 Troubleshooting 16
9.4 Disposal 16

DMUI-HSM - MANUAL // PAGE 4
1 GENERAL INFORMATION
Documentation for the DMUI-HSM consists of this Operating Manual and several other documents (Other
applicable documents, page 5). Assembly personnel must read all documentation before starting assembly.
Keep all documentation for as long as the product is in your possession. Ensure that all documentation is
provided to subsequent owners. Go to www.logicdata.net for more information and support. This Manual
may change without notice. The most recent version is available on our website.
1.1 OTHER APPLICABLE DOCUMENTS
This Operating Manual is part of the documentation required to safely assemble and operate the DYNAMIC
MOTION SYSTEM (DM System). Other applicable documents include:
• DYNAMIC MOTION System Manual
• Datasheet and Operating Manual for the installed DYNAMIC MOTION Actuator
• Datasheet for the installed Power Unit
1.2 COPYRIGHT
© January 2020 by LOGICDATA Electronic und Software Entwicklungs GmbH. All rights reserved, except for
those listed in Chapter 1.3 Royalty-free use of images and text on page 5.
1.3 ROYALTY-FREE USE OF IMAGES AND TEXT
After purchase and full payment of the product, all text and images in Chapter 2 “Safety”, may be used free of
charge by the customer for 10 years after delivery. They should be used to prepare end user documentation
for Height-Adjustable Table Systems. The license does not include logos, designs, and page layout elements
belonging to LOGICDATA. The Reseller may make any necessary changes to the text and images to adapt
them for the purpose of end user documentation. Texts and images may not be sold in their current state
and may not be published or sublicensed digitally. The transfer of this license to third parties without per-
mission from LOGICDATA is excluded. Full ownership and copyright of the text and graphics remain with
LOGICDATA. Texts and graphics are oered in their current state without warranty or promise of any kind.
1.4 TRADEMARKS
Documentation may include the representation of registered trademarks of goods or services, as well as
information about copyright or other proprietary expertise of LOGICDATA or third parties. In all cases, all
rights remain exclusively with the respective copyright holder. LOGICDATA® is a registered trademark of
LOGICDATA Electronic & Software GmbH in the USA, the European Union, and other countries.

DMUI-HSM - MANUAL // PAGE 5
2 SAFETY
2.1 TARGET AUDIENCE
This Operating Manual is intended for Skilled Persons only. Refer to Chapter 2.8 Skilled Persons on page 9 to
ensure that personnel meet all requirements.
2.2 GENERAL SAFETY REGULATIONS
In general, the following safety regulations and obligations apply when handling the product:
• Do not operate the product unless it is in a clean and perfect condition
• Do not remove, change, bridge, or bypass any protection, safety, or monitoring equipment
• Do not convert or modify any components without written approval from LOGICDATA
• In the event of malfunction or damage, faulty components must be replaced immediately
• Unauthorized repairs are prohibited
• Do not attempt to replace hardware unless the product is in a de-energized state
• Only Skilled Persons are allowed to work with DMUI-HSM Handsets
• Ensure that national worker protection conditions and national safety and accident prevention
regulations are observed during operation of the system
2.3 INTENDED USE
The DMUI-HSM is a Handset for electrically Height-Adjustable Tables. It is installed by Resellers into Height-
Adjustable Table systems. It controls Height-Adjustable Table systems via an integrated Control Unit in the
connected DYNAMIC MOTION Actuator. It is intended for indoor use only. It may only be installed in com-
patible Height-Adjustable Tables and with LOGICDATA-approved accessories. Contact LOGICDATA for fur-
ther details. Use beyond or outside the intended use will void the product’s warranty.
2.4 REASONABLY FORESEEABLE MISUSE
Usage outside of the intended use for each product may lead to minor injury, serious injury, or even death.
Reasonably foreseeable misuse of DMUI-HSM Handsets includes, but does not extend to:
• Connecting unauthorized parts to the product. If you are unsure as to whether a part can be used
with a DMUI-HSM Handset, contact LOGICDATA for further information

DMUI-HSM - MANUAL // PAGE 6
2.5 EXPLANATION OF SYMBOLS AND SIGNAL WORDS
Safety Notices contain both symbols and signal words. The signal word indicates the severity of the hazard.
DANGER Indicates a hazardous situation which, if not avoided, will result in death or serious
injury.
WARNING Indicates a hazardous situation which, if not avoided, could result in death or serious
injury.
CAUTION Indicates a hazardous situation which, if not avoided, could result in minor or moderate
injury.
NOTICE Indicates a situation which, if not avoided, could result in damage to the product
through electrostatic discharge (ESD).
NOTICE Indicates a situation that will not lead to personal injury, but could lead to damage to
the device or the environment.
INFO Indicates the protection class of the device: Protection Class III.
Protection Class III devices may only be connected to SELV or PELV power sources.
INFO Indicates important tips for handling the product.
2.6 LIABILITY
LOGICDATA products comply with all currently applicable health and safety regulations. However, risk can
result from incorrect operation or misuse. LOGICDATA is not liable for damage or injury caused by:
•Improper product use
•Disregard of the documentation
•Unauthorized product alterations
•Improper work on and with the product
•Operation of damaged products
•Wear parts
•Improperly performed repairs
•Unauthorized changes to the operating parameters
•Disasters, external inuence, and force majeure
The information in this Operating Manual describes the characteristics of the product without assurances.
Resellers assume responsibility for the LOGICDATA products installed in their applications. They must en-
sure their product complies with all relevant directives, standards, and laws. LOGICDATA shall not be held
liable for any damage that is directly or indirectly caused by the delivery or use of this document. Resellers
must observe the relevant safety standards and guidelines for each product in the Table System.

DMUI-HSM - MANUAL // PAGE 7
2.7 RESIDUAL RISKS
Residual risks are the risks that remain after all relevant safety standards have been complied with. These
have been evaluated in the form of a risk assessment. Residual risks associated with assembly and instal-
lation of DMUI-HSM Handsets are listed here and throughout this Operating Manual. The risks associ-
ated with the system as a whole are listed in the System Manual. See also Chapter 1.1 Other Applicable
Documents on page 5. The symbols and signal words used in this Operating Manual are listed in Chapter 2.5
Explanation of Symbols and Signal Words on page 7.
WARNING Risk of death or serious injury through electric shocks
The DMUI-HSM is an electrical device. Although you will not have to connect any prod-
ucts to the Power Unit during assembly, basic safety precautions must be taken at all
times. Failure to observe electrical safety precautions may lead to death or serious inju-
ry through electric shocks.
• Never open a DMUI-HSM Handset
• Ensure that the product is not connected to the Power Unit during assembly
• Do not convert or modify the DMUI-HSM Handset in any way
• Do not immerse the DMUI-HSM Handset or its components in liquid. Clean only
with a dry or slightly damp cloth
• Do not place the Cable of the DMUI-HSM Handset on heated surfaces
• Check the housing and cables of the DMUI-HSM Handset for visible damage. Do
not install or operate damaged products
WARNING Risk of death or serious injury in explosive atmospheres
Operating the Handset in potentially explosive atmospheres may lead to death or seri-
ous injury through explosions.
• Read the relevant directives to determine if an atmosphere is potentially explosive
• Do not operate the Handset in potentially explosive atmospheres
CAUTION Risk of minor or moderate injury through tripping
During the assembly process, you may have to step over Cables. Tripping over Cables
may lead to minor or moderate injury.
• Ensure that the assembly area is kept clear of unnecessary obstructions
• Be careful not to trip over Cables
CAUTION Risk of minor or moderate injury through crushing
If any Handset Key becomes stuck while the system is in motion, the system may not
stop properly. This may lead to minor or moderate injury through crushing.
• Disconnect the system immediately if any Handset Key becomes stuck
2.8 SKILLED PERSONS
CAUTION Risk of injury through incorrect assembly
Only Skilled Persons have the expertise to complete the assembly process safely.
Assembly by Unskilled Persons may lead to minor or moderate injury.
• Ensure that only Skilled Persons are allowed to complete assembly
• Ensure that persons with limited ability to react to danger do not take part in the
assembly process
DMUI-HSM Handsets may only be installed by Skilled Persons. A Skilled Person is dened as someone who:
• Is authorized for installation planning, installation, commissioning, or servicing of the product
• Has read and understood all documentation relevant to the DYNAMIC MOTION system
• Has the technical education, training, and/or experience to perceive risks and avoid hazards
• Has knowledge of the specialist standards applicable to the product
• Has the expertise to test, assess, and manage electrical and mechatronic products and systems in
accordance with the generally accepted standards and guidelines of electrical engineering and fur-
niture manufacturing

DMUI-HSM - MANUAL // PAGE 8
2.9 NOTES FOR RESELLERS
Resellers are companies that purchase LOGICDATA products for installation in their own products.
INFO For reasons of EU conformity and product safety, Resellers should provide end users
with an Operating Manual in their native EU ocial language.
INFO Operating Manuals must include all the safety instructions that end users require to
handle the product safely. They must also include an instruction to always keep the
Operating Manual in the immediate vicinity of the product.
INFO No unauthorized persons (young children, persons under the inuence of medications,
etc.) should be allowed to handle the product.
INFO Resellers must perform a risk assessment on their product that covers residual hazards.
It must include measures to mitigate risk, or reference the product's Operating Manual.
INFO The Charter of the French Language (La charte de la langue française) or Bill 101
(Loi 101) guarantees the right of the population of Quebec to conduct business and
commercial activities in French. The bill applies to all products sold and used in Quebec.
For table systems that will be sold or used in Quebec, Resellers must provide all product-
relevant texts in French. These include, but are not limited to:
• Operating Manuals
• All other product documentation, including datasheets
• Inscriptions on the product (such as labels), including those on product packaging
• Warranty certicates
The French inscription may be accompanied with a translation or translations, but no
inscription in another language may be given greater prominence than that in French.
3 SCOPE OF DELIVERY
The standard scope of delivery for the DMUI-HSM consists of the DMUI-HSM Handset and its pre-attached
cable. All other components necessary for installing the DMUI-HSM Handset (e.g. Mounting Screws) must
be supplied separately by the Reseller.
4 UNPACKAGING
NOTICE Ensure proper ESD handling during unpackaging. Damage that can be attributed to
electrostatic discharge will void warranty claims.
To unpackage the product:
1. Remove all components from the packaging
2. Check the contents of the package for completeness and damage
3. Provide the Operating Manual to the operating personnel
4. Dispose of the packaging material
NOTICE Dispose of the packaging material in an environmentally friendly manner. Remember
to separate plastic parts from the cardboard packaging.

DMUI-HSM - MANUAL // PAGE 9
5 PRODUCT
Fig.1 shows a standard model of the DMUI-HSM. The exact variant of the DMUI-HSM is denoted by the prod-
uct's order code. Consult the accompanying datasheet to ensure that you have received the correct variant.
5.1 KEY PRODUCT FEATURES
1 Mounting Points
2 UP / DOWN Keys
3 LED Signal Light
Fig. 1: Product features, DMUI-HSM
1
2
3

DMUI-HSM - MANUAL // PAGE 10
5.2 DIMENSIONS
Length 50.0 mm | 1.969 “
Width 59.9 mm | 2.358 "
Height (to underside of Table Top) 17.3 mm | 0.681 "
Fig. 2: Product dimensions, DMUI-HSM
17.3mm
0.681"
50mm
1.969"
59.9mm
2.358"

DMUI-HSM - MANUAL // PAGE 11
5.3 DRILLING TEMPLATE
There are two variants for mounting. In the Standard Position the drilled holes should be 8 mm from the
front edge of the Table Top and 43.8 mm apart.
Alternatively, the drilled holes can be set to the Transportation Postion, 24 mm from the front edge of the
Table Top and 43.8 mm apart. The Transportation Position allows the DMUI-HSM to be slid backwards un-
derneath the Table Top, so that the Handset does protrude from the front edge of the table when in transport.
The Side Edge of the DMUI-HSM does not have to be ush with the Table's Side Edge. Leave a minimum of
20 mm between the outer hole and the Side Edge to ensure the DMUI-HSM does not protrude from the side.
43.8mm
1.724"
8mm
0.315"
24mm
0.945"
Table Edge
Table Edge
Standard Position
Transportation Position

DMUI-HSM - MANUAL // PAGE 12
6 ASSEMBLY
This chapter describes the process of installing the DMUI-HSM Handset into the DYNAMIC MOTION System.
6.1 SAFETY DURING ASSEMBLY
WARNING Risk of death or serious injury through electric shocks
DMUI-HSM Handsets are electrical devices. Basic safety precautions must be taken at
all times. Failure to observe electrical safety precautions may lead to death or serious
injury through electric shocks.
• Never open the Handset
• Ensure that the Handset is not connected to the Power Unit during assembly
• Do not convert or modify the Handset in any way
• Check the housing and cables of the Handset for visible damage. Do not install or
operate damaged products.
CAUTION Risk of minor or moderate injury through improper handling
Improper handling of the product during assembly may lead to minor or moderate in-
jury through cutting, pinching, and crushing.
• Avoid contact with sharp edges
• Be careful while handling tools that may cause personal injury
• Ensure assembly complies with the generally accepted standards and guidelines of
electrical engineering and furniture manufacturing
• Read all instructions and safety advice carefully
CAUTION Risk of minor or moderate injury through tripping
During assembly and operation, poorly routed Cables may become a trip hazard.
Tripping over Cables may lead to minor or moderate injury.
• Ensure that Cables are routed properly to avoid trip hazards
• Be careful not to trip over Cables when installing the Handset
NOTICE Ensure proper ESD handling during assembly. Damage that can be attributed to electro-
static discharge will void warranty claims.
NOTICE To avoid damage to the product, measure the dimensions of the Handset before
assembly.
NOTICE Before assembly, all parts must be acclimatised to the ambient conditions.
NOTICE Do not lift the Handset by its cable. This will cause irreparable damage to the product.
INFO Perform a product risk assessment so that you can respond to potential residual haz-
ards. Assembly instructions must be included in your end user Operating Manual.

DMUI-HSM - MANUAL // PAGE 13
6.2 REQUIRED COMPONENTS
1 DMUI-HSM Hansdet
2 2 Mounting Screws (supplied by Reseller)
Tool Drill or Drilling Machine
Tool Screwdriver
INFO
Screw specications
The mounting points for the DMUI-HSM have a width of 4.3 mm. The Mounting Screws
should hold the Handset safely and securely in place. Exact specications can be provided
by LOGICDATA on request.
6.3 PROCESS
1. Position the Handset under the table top and mark the position of the Mounting Points.
2. Drill the holes for the Mounting Screws into the Table Top at the marked points.
3. Use the screwdriver and 2 Mounting Screws to attach the Handset to the Table Top at the drilled
holes.
NOTICE The required tightening torque depends on the material of the Table Top. Do not exceed
2 Nm.
6.4 COMPLETING ASSEMBLY
After the DMUI-HSM is attached to the Table Top, you must connect the Cable to the Power Hub. Refer to the
manual for your chosen Power Hub for instructions.

DMUI-HSM - MANUAL // PAGE 14
7 SYSTEM INFORMATION
When a DMU-HSM Handset is installed alongside the DYNAMIC MOTION system, system information is
communicated via ashes of the LED Signal Light. Possible signals are as follows:
Signal Message Required Actions
No Light System operating normally Operate the DM System as normal.
System not connected
properly
See Chapter 4 for connection instructions.
Red Light Blinking System Error Warning Release all Keys and wait for 5 seconds. Then,
try to repeat the action again.
Disconnect all components from the Power
Hub.
Disconnect the Power Hub from the Mains.
Check the Power Hub for overheating. Let cool
if necessary.
Check all cable connections and reconnect the
system.
If problem persists:
Perform a Position Reset Procedure (Chapter
4.7).
Contact LOGICDATA
Green Light Blinking System Start-up Wait until the LED has stopped blinking to
continue.
Do not press any buttons.
Reset in Progress
Duty Cycle Exceeded
Collision Detected (ISP) Remove the obstruction from the Table System.
Remove unnecessary loads from the Table Top
Operate the DM System as normal.
Green Light Flashing
Rapidly
Position Reset Required. Perform a Position Reset Procedure (System
Manual, Chapter 4.7).
NOTICE Do not operate the DYNAMIC MOTION system if problems persist. Contact LOGICDATA
for further information.

DMUI-HSM - MANUAL // PAGE 15
8 OPERATION
Instructions for operating the system can be found in the DYNAMIC MOTION System Manual. A list of core
features can be found below. Handset Keys are represented as follows for further description:
UP Key
DOWN Key
8.1 ADJUSTING THE TABLE TOP HEIGHT
CAUTION Risk of minor or moderate injury through crushing
Your ngers may be crushed when you attempt to change the height of the table
• Keep ngers away from moving parts
• Ensure that no persons or objects are in the table's range of motion
INFO The Table Top will move up or down until the UP or DOWN Key is released, or if a pre-de-
ned stopping point has been reached.
To move the Table Top UP:
Press and hold the UP Key until the desired height has been reached
To move the Table Top DOWN:
Press and hold the DOWN Key until the desired height has been reached
1
2

DMUI-HSM - MANUAL // PAGE 16
9 ADDITIONAL INFORMATION
9.1 DISASSEMBLY
To disassemble the DMUI-HSM Handset, ensure that it has been disconnected from the Power Unit. Then,
follow the assembly instructions for your chosen product in reverse order.
9.2 MAINTENANCE
The DMUI-HSM is maintenance-free for its entire service lifetime.
WARNING Risk of death or serious injury through electric shocks and other hazards
Using a DMUI-HSM Handset alongside unauthorized spare or accessory parts may lead
to death or serious injury through electric shocks and other hazards.
• Only use accessory parts produced or approved by LOGICDATA
• Only use replacement parts produced or approved by LOGICDATA
• Only allow Skilled Persons to perform repairs or install accessory parts
• Contact customer services immediately if the system malfunctions
The use of unauthorized spare or accessory parts may cause system damage. Warranty
claims are void in this scenario.
9.2.1 CLEANING
1. Disconnect the system from the Power Unit
2. Wait 30 seconds for residual voltage to dissipate.
3. Wipe the surface of the Handset with a dry or slightly damp soft cloth. Never immerse the
Handset into liquid
4. Wait for the Handset to dry completely
5. Reconnect the Power Unit
9.3 TROUBLESHOOTING
A list of common problems and their solutions can be found in the DYNAMIC MOTION System Manual.
Most errors with DMUI-HSM Handsets occur when the Control Panel is touched during calibration. Such
errors can be avoided by waiting for 10 seconds to use the Control Panel after start-up. If your DMUI-HSM
Handset is not functioning, a reset may be required. To reset, proceed as follows:
1. Unplug the DMUI-HSM Handset from the Power Unit.
2. Wait for 10 seconds.
3. Plug the DMUI-HSM Handset back to the motor Power Unit
4. Wait for 10 seconds.
▸ The DMUI-HSM Handset is ready for operation.
9.4 DISPOSAL
All products in the DM System are subject to the WEEE Directive2012/19/EU.
• Dispose of all components separately from household waste. Use designated collection
points or disposal companies authorized for this purpose

www.logicdata.net
LOGICDATA
Electronic & Software Entwicklungs GmbH
Wirtschaftspark 18
8530 Deutschlandsberg
Austria
Phone: +43 (0)3462 5198 0
Fax: +43 (0)3462 5198 1030
Internet: http://www.logicdata.net
LOGICDATA North America, Inc.
1525 Gezon Parkway SW, Suite C
Grand Rapids, MI 49509
USA
Phone: +1 (616) 328 8841
Email: o[email protected]
Table of contents
Other LOGICDATA Control Unit manuals
Popular Control Unit manuals by other brands

Animal Factory Amplification
Animal Factory Amplification Coma Reactor user manual

Locinox
Locinox Turnitec user guide

Gemu
Gemu 8357 Installation, operating and maintenance instructions

Tube-Town
Tube-Town PoS150 manual

ISB
ISB RBPC installation manual

Automationdirect.com
Automationdirect.com Productivity 1000 P1-16CDR manual

Gascat
Gascat ARES N Installation, operation & maintenance manual

Wiznet
Wiznet WIZ200WEB user manual

Quectel
Quectel SC20-CE user guide

Ericsson
Ericsson DM-20 Interface manual

Sierra Wireless
Sierra Wireless AirPrime AR7594 Hardware integration guide