LOGICDATA SMARTneo-2G User manual

MANUAL
Document Version 1.0 /May 2019
SMARTneo-2G

SMARTNEO - OPERATING MANUAL // PAGE 2
SMARTneo-2G - Operating Manual
Document Version 1.0/May 2019
This document was originally published in English.
LOGICDATA Electronic & Software Entwicklungs GmbH
Wirtschaftspark 18
8530 Deutschlandsberg
Austria
Phone: +43 (0) 3462 51 98 0
Fax: +43 (0) 3462 51 98 1030
Internet: http://www.logicdata.net
Email: o[email protected]

SMARTNEO - OPERATING MANUAL // PAGE 3
CONTENTS
1 General information 5
1.1 Other applicable documents 5
1.2 Copyright 5
1.3 Royalty-free use of images and text 5
1.4 Trademarks 5
2 Safety 6
2.1 Target audience 6
2.2 General safety regulations and obligations 6
2.3 Intended use 6
2.4 Reasonably foreseeable misuse 6
2.5 Explanation of symbols and signal words 7
2.6 Liability 7
2.7 Residual risks 8
2.8 Skilled Persons 9
2.9 Notes for Resellers 10
3 Scope of delivery 10
4 Product 11
4.1 Key Product Features 11
4.1.1 Plug Ports and Connections 11
4.2 Dimensions 12
4.2.1 Drilling Template 12
5 Assembly 14
5.1 Safety During Assembly 14
5.2 Required Components 14
5.3 Process 15
5.4 Completing Assembly 16
6 Connecting the System 16
6.1 System Conguration 16
6.1.1 Required Components: System with 1 Actuator 16
6.1.2 Required Components: System with 2 Actuators 16
6.2 Connecting Actuators 17
6.3 Connecting User Interfaces 17
6.4 Cascading 17
6.5 External Power Supplies 17
6.6 Connecting to the Mains 17
6.7 Performing a Position Reset Procedure 17
6.8 Conguration Example 18

SMARTNEO - OPERATING MANUAL // PAGE 4
7 Operation 19
7.1 Adjusting the Table Top Height 19
7.2 Saving a Memory Position 20
7.2.1 Using a Basic Hand Control 20
7.2.2 Using a Comfort Hand Control 20
7.3 Adjusting the Table to a Memory Position 21
7.3.1 Using a Basic Hand Control 21
7.3.2 Using a Comfort Hand Control 21
8 Software-dependent Functions 23
8.1 Low Speed Area 23
8.2 Safety Area 23
8.3 Factory Reset (S0 Reset) 23
8.3.1 Using a Basic Hand Control 23
8.3.2 Using a Comfort Hand Control 23
8.4 Container Stop and Shelf Stop Positions 24
8.4.1 Using a Basic Hand Control 24
8.4.2 Using a Comfort Hand Control 24
8.5 Correcting the Height Display 25
8.6 Changing the Displayed Unit of Measurement 25
8.7 Duty Cycle Monitoring 25
9 Actuator Setup
9.1 Plug Detection 26
9.2 SLIMdrive Detection: Changing SLIMdrive type 26
9.3 Auto-detect: Changing the number of SLIMdrives 27
9.4 Changing the number of Actuators (other) 27
10 Troubleshooting 28
10.1 Possible Problems and their Solutions 28
10.2 Click Codes 29
10.3 Error Messages on the Display of the Hand Control 29
11 Additional Information 31
11.1 Disassembly 31
11.2 Collision Detection 31
11.2.1 Intelligent System Protection 31
11.2.2 Drive Back Function 31
11.3 Maintenance 31
11.4 Disposal 32

SMARTNEO - OPERATING MANUAL // PAGE 5
1 GENERAL INFORMATION
Documentation for the SMARTneo-2G consists of this Operating Manual and several other documents
(Other applicable documents, page 5). Read all documentation before assembling or operating the table sys-
tem. Keep all documentation for as long as the product is in your possession. Ensure that all documentation
is provided to subsequent owners. Go to www.logicdata.net for more information and support. This Manual
may change without notice. The most recent version is available on our website.
1.1 OTHER APPLICABLE DOCUMENTS
This Operating Manual assumes that the reader has read the following documents:
• Datasheet and Operating Manual for the installed Actuator(s)
• Datasheet and Operating Manual for the installed User Interface (Hand Control or other)
• Datasheet and Operating Manual (if applicable) for any installed accessory products
• SMARTneo-2G Cascading Manual, if a Cascading System is to be installed
1.2 COPYRIGHT
© May 2019 by LOGICDATA Electronic und Software Entwicklungs GmbH. All rights reserved, except for
those listed in Chapter 1.3 Royalty-free use of images and text on page 5.
1.3 ROYALTY-FREE USE OF IMAGES AND TEXT
After purchase and full payment of the product, all text and images in Chapter 2, “Safety”, may be used free
of charge by the customer for 10 years after delivery. They should be used to prepare end user documentation
for height-adjustable table systems. The license does not include logos, designs, and page layout elements
belonging to LOGICDATA. The customer may make any necessary changes to the text and images to adapt
them for the purpose of end user documentation. Texts and images may not be sold in their current state,
and may not be published or sublicensed digitally. The transfer of this license to third parties without per-
mission from LOGICDATA is excluded. Full ownership and copyright of the text and graphics remain with
LOGICDATA. Texts and graphics are oered in their current state without warranty or promise of any kind.
1.4 TRADEMARKS
Documentation may include the representation of registered trademarks of goods or services, as well as
information about copyright or other proprietary expertise of LOGICDATA or third parties. In all cases, all
rights remain exclusively with the respective copyright holder. LOGICDATA® is a registered trademark of
LOGICDATA Electronic & Software GmbH in the USA, the European Union, and other countries.

SMARTNEO - OPERATING MANUAL // PAGE 6
2 SAFETY
2.1 TARGET AUDIENCE
This manual is intended for Skilled Persons only. Refer to Chapter 2.8, Skilled Persons on page 9 to ensure
that personnel meet all requirements.
2.2 GENERAL SAFETY REGULATIONS
In general, the following safety regulations and obligations apply when handling the product:
• Do not operate the SMARTneo-2G unless it is in a clean and perfect condition
• Do not remove, change, bridge, or bypass any protection, safety, or monitoring equipment
• Do not convert or modify any components without written approval from LOGICDATA
• In the event of malfunction or damage, any faulty components must be replaced immediately
• Unauthorized repairs are prohibited
• Do not attempt to replace hardware unless the system is in a de-energized state
• Only skilled persons are allowed to work on the SMARTneo-2G
• Ensure that national worker protection conditions and national safety and accident prevention
regulations are observed during operation of the system
2.3 INTENDED USE
The SMARTneo-2G is a Control Box for electrically Height-Adjustable Tables. It is intended for indoor use
only. The system may only be installed in compatible Height-Adjustable Tables and with LOGICDATA-
approved accessories. Contact LOGICDATA for further details. Use beyond or outside the intended use will
void the product’s warranty. Please refer to the Operating Manual of each product in the Table System to
determine its individual intended use.
The installation site must be level, vibration-free, and free from contamination. It must be ensured that there
is no extraordinary exposure through dust, toxic or caustic gases and vapours, or through inadmissible heat
exposure at the installation site.
2.4 REASONABLY FORESEEABLE MISUSE
Usage outside of the intended use of the SMARTneo-2G could lead to minor injuries, serious injuries, or even
death. Reasonably foreseeable misuse of the system includes, but does not extend to:
• Using the system as a climbing or lifting aid for people or animals
• Connecting unauthorized products to the SMARTneo-2G. If you are unsure as to whether a
product can be used with the SMARTneo-2G, contact LOGICDATA for further information
• Overloading the Table System

SMARTNEO - OPERATING MANUAL // PAGE 7
2.5 EXPLANATION OF SYMBOLS AND SIGNAL WORDS
Safety notices contain both symbols and signal words. The signal word indicates the severity of the hazard.
DANGER Indicates a hazardous situation which, if not avoided, will result in death or serious
injury.
WARNING Indicates a hazardous situation which, if not avoided, could result in death or serious
injury.
CAUTION Indicates a hazardous situation which, if not avoided, could result in minor or moder-
ate injury.
NOTICE Indicates a situation which, if not avoided, could result in damage to the product
through electrostatic discharge (ESD).
NOTICE Indicates a situation that will not lead to personal injury, but could lead to damage to
the device or the environment.
INFO Indicates the protection class of the device: Protection Class III.
Protection Class III devices may only be connected to SELV or PELV power sources.
INFO Indicates important tips for handling the product.
2.6 LIABILITY
LOGICDATA products comply with all currently applicable health and safety regulations. However, risk can
result from incorrect operation or misuse. LOGICDATA is not liable for damage or injury caused by:
• Improper product use
• Disregard of the documentation
• Unauthorized product alterations
• Improper work on and with the product
• Operation of damaged products
• Wear parts
• Improperly performed repairs
• Unauthorized changes to the operating parameters
• Disasters, external inuence, and force majeure
The information in this documentation describes the characteristics of the system without assurances.
Resellers assume responsibility for the LOGICDATA products installed in their applications. They must en-
sure their product complies with all relevant directives, standards and laws. LOGICDATA shall not be held
liable for any damage that is directly or indirectly caused by the delivery or use of this document. Resellers
must observe the relevant safety standards and guidelines for each product in the Table System.

SMARTNEO - OPERATING MANUAL // PAGE 8
2.7 RESIDUAL RISKS
Residual risks are the risks that remain after all relevant safety standards have been complied with. These
have been evaluated in the form of a risk assessment. Residual risks associated with the operation of the
table system as a whole are listed here and throughout this Operating Manual. The risks associated with
the installation of other products in the system are detailed in the respective product’s Operating Manual.
See also Chapter 1.1 Other Applicable Documents on page 5. The symbols and signal words used in this
Operating Manual are listed in Chapter 2.5 Explanation of Symbols and Signal Words on page 7.
WARNING Risk of death or serious injury through electric shocks
The SMARTneo-2G is an electrical device. Basic safety precautions must be taken at
all times. Failure to observe electrical safety precautions may lead to death or serious
injury through electric shocks.
• Never open the SMARTneo-2G or its components
• Ensure that the SMARTneo-2G is not connected to the mains during assembly
• Ensure that the SMARTneo-2G is supplied with the mains voltage specied on the
Type Plate
• Do not convert or modify the SMARTneo-2G in any way
• Do not place the Cable of the SMARTneo-2G on heated surfaces
• Do not immerse the SMARTneo-2G or its components in liquid. Clean only with a
dry or slightly damp cloth
• Check the housing and cables of the SMARTneo-2G for visible damage. Do not in-
stall or operate damaged products.
WARNING Risk of death or serious injury in explosive atmospheres
Operating the system in potentially explosive atmospheres may lead to death or serious
injury through explosions.
• Read the relevant directives to determine if an atmosphere is potentially explosive
• Do not operate the system in potentially explosive atmospheres
WARNING Moderate risk of serious injury through electric shocks
While cleaning or using the system, liquid intrusion may lead to serious injury through
electric shocks.
• Do not allow any components to become wet during cleaning
• Ensure components are placed away from areas where spillages are likely to occur
• Take care not to spill liquids onto or around the system
WARNING Moderate risk of serious injury through electric shocks
Inserting incorrect cables into the SMARTneo-2G may lead to death or serious injury
through electric shocks.
• Ensure only LOGICDATA-approved products are connected to the SMARTneo-2G
• Do not insert incompatible cables into the SMARTneo-2G
• Do not attempt to force cables into the incorrect plug ports
CAUTION Risk of minor or moderate injury through unexpected movement
Exceeding the static or dynamic load limits of the Table System may cause unexpected
operation. This may lead to minor or moderate injury.
• Do not exceed load limits

SMARTNEO - OPERATING MANUAL // PAGE 9
CAUTION Risk of minor or moderate injury through crushing
If any Hand Control Key becomes stuck while the system is in motion, the system may
not stop properly. This may lead to minor or moderate injury through crushing.
• Disconnect the system immediately if any Hand Control Key becomes stuck
CAUTION Risk of minor or moderate injury through tripping
During the assembly process, you may have to step over Cables. Tripping over Cables
may lead to minor or moderate injury.
• Ensure that the assembly area is kept clear of unnecessary obstructions
• Be careful not to trip over Cables
CAUTION This appliance can be used by children from 8 years and above and people with reduced
physical, sensory or mental capabilities or lack of experience and knowledge if they
have been given supervision or instruction concerning the use of the appliance in a safe
way and understand the hazards involved. Children must not play with the appliance.
Cleaning and maintenance by the user must not be performed by children, unless they
are over 8 years old and supervised.
2.8 SKILLED PERSONS
CAUTION Risk of injury through incorrect installation
Only Skilled Persons have the expertise to complete the installation process safely.
Installation by unskilled persons can lead to minor or moderate personal injury.
• Ensure that only Skilled Persons are allowed to complete the installation
• Ensure that persons with limited ability to react to danger do not take part in the
assembly process
The table system may only be assembled by Skilled Persons. A Skilled Person is dened as someone who:
• Is authorized for installation planning, installation, commissioning, or maintenance/servicing
of the product
• Has read and understood the Table System documentation, as well as the documentation rele-
vant to the component products of the system
• Has the technical education, training, and/or experience to perceive risks and avoid hazards
• Has knowledge of the specialist standards applicable to the product
• Has the expertise to test, assess, and manage electrical and mechatronic products and systems
in accordance with the generally accepted standards and guidelines of electrical engineering
and furniture manufacturing

SMARTNEO - OPERATING MANUAL // PAGE 10
2.9 NOTES FOR RESELLERS
Resellers are companies that purchase LOGICDATA products for installation in their own products.
INFO For reasons of EU conformity and product safety, Resellers should provide end users
with an Operating Manual in their native EU ocial language.
INFO The Charter of the French Language (La charte de la langue française) or Bill 101
(Loi 101) guarantees the right of the population of Quebec to conduct business and
commercial activities in French. The bill applies to all products sold and used in Quebec.
For table systems that will be sold or used in Quebec, Resellers must provide all product-
relevant texts in French. These include, but are not limited to:
• Operating Manuals
• All other product documentation, including datasheets
• Inscriptions on the product (such as labels), including those on product packaging
• Warranty certicates
The French inscription may be accompanied with a translation or translations, but no
inscription in another language may be given greater prominence than that in French.
INFO Operating Manuals must include all the safety instructions that end users require to
handle the product safely. They must also include an instruction to always keep the
Operating Manual in the immediate vicinity of the product.
INFO No unauthorized persons (young children, persons under the inuence of medications,
etc.) should be allowed to handle the product.
INFO Resellers must perform a risk assessment on their product that covers residual hazards.
It must include measures to mitigate risk or reference the product's Operating Manual.
3 SCOPE OF DELIVERY
The scope of delivery for the SMARTneo-2G consists of the following components:
1 SMARTneo-2G Control Box
All other components required for assembly are to be provided by the Reseller unless otherwise stated by
LOGICDATA. Cables and Mounting Screws are not included in the scope of delivery.
1

SMARTNEO - OPERATING MANUAL // PAGE 11
4 PRODUCT
The SMARTneo-2G is a Control Box for height-adjustable tables. There are variants of the SMARTneo-2G
for specic domestic mains power supplies (e.g. EU or US). The exact variant is denoted by the product's
order code. Consult the accompanying Datasheet to ensure that you have received the correct variant. The
functions your SMARTneo-2G Control Box can full is also dependent on parameterization (see Chapter 8
Software Dependent Functions).
4.1 KEY PRODUCT FEATURES
4.1.1 PLUG PORTS AND CONNECTIONS
You must read the full product documentation of each product you are connecting to the SMARTneo-2G to
ensure correct assembly and the safety of all users. Fig. 1 shows all the plug ports and connections featured
in the SMARTneo-2G.
The SMARTneo-2G has connection points for the following product types:
• Actuators
• Hand Controls
• Power Input (Mains or Battery Pack)
• Communication cable (Cascading)
1 Hand Control Port (HC)
2 AC Input Port (Power Cable)
3 DC/Com Port
4 Motor Port 1 (M1)
5 Motor Port 2 (M2)
Fig. 1: SMARTneo-2G Connection Points
1
4
3
2
5

SMARTNEO - OPERATING MANUAL // PAGE 12
4.2 DIMENSIONS
Length 188.3 mm | 7.874 "
Width 84.5 mm | 3.328 "
Height 35.0 mm | 1.376 "
Fig. 2: Dimensions SMARTneo-2G (scaled 1:2)
4.2.1 DRILLING TEMPLATE
See overleaf.
84.5 mm
3.328 “
200 mm
7.874 “
188.3 mm
7.411 “
35 mm
1.376 “

SMARTNEO - OPERATING MANUAL // PAGE 13
DRILLING TEMPLATE
The mounting points for the
SMARTneo-2G have a diam-
eter of 5.5 mm.
The drilled holes must be
200 mm (lengthways) and
49.2 mm (widthways) apart.
The entire housing of the
SMARTneo-2G must be un-
derneath the table.
49.2 mm (±0.15 mm)
1,937 " (± 0,006 ")
200.0 mm (±0.35mm)
7.874 " (±0,014 ")

SMARTNEO - OPERATING MANUAL // PAGE 14
5 ASSEMBLY
This chapter of the Operating Manual describes the process of mounting the SMARTneo-2G to the Table
Top. You must read the documentation for each part of the system (Actuator, User Interface, Power Unit,
etc.) for that product’s mounting instructions. Instructions for connecting the system's components to the
SMARTneo-2G can be found in Chapter 6, Connecting the System).
5.1 SAFETY DURING ASSEMBLY
CAUTIONRisk of minor or moderate injury through improper handling
Improper handling of the product during assembly may lead to minor or moderate in-
jury through cutting, pinching, and crushing.
• Avoid contact with sharp edges
• Be careful while handling tools that may cause personal injury
• Ensure assembly complies with the generally accepted standards and guidelines of
electrical engineering and furniture manufacturing
• Read all instructions and safety advice carefully
CAUTION Risk of minor or moderate injury through tripping
During assembly and operation, poorly routed Cables may become a trip hazard.
Tripping over Cables may lead to minor or moderate injury.
• Ensure that Cables are routed properly to avoid trip hazards
• Be careful not to trip over Cables when installing the Hand Control
NOTICE Ensure proper ESD handling during assembly. Damage that can be attributed to electro-
static discharge will void warranty claims.
NOTICE Before assembly, all parts must be acclimatised to the ambient conditions.
INFO Perform a product risk assessment so that you can respond to potential residual haz-
ards. Assembly instructions must be included in your end user Operating Manual
5.2 REQUIRED COMPONENTS
1SMARTneo-2G Control Box
22 Mounting Screws (supplied by Reseller)
Tool Drill or drilling machine
Tool Screwdriver
INFO Screw specications
The mounting points for the SMARTneo-2G have a diameter of 5.5 mm. The Mounting
Screws should hold the SMARTneo-2G safely and securely in place. Exact specications
can be provided by LOGICDATA on request.

SMARTNEO - OPERATING MANUAL // PAGE 15
5.3 PROCESS
WARNING Moderate risk of serious injury through electric shocks
While using the SMARTneo-2G, liquid intrusion may lead to serious injury through
electric shocks.
• Ensure components are placed away from areas where spillages may occur
• Take care not to spill liquids onto or around the Control Box
NOTICE LOGICDATAdoesnotrestrictcustomerstospecicmountingpositonsfortheSMARTneo-
2G. However, mounting the Control Box incorrectly may cause the Light Barrier colli-
sion detection system to malfunction. To ensure correct installation, all Table Tops must
be tested thoroughly (dierent materials, thicknesses, etc.). Additionally:
• Ensure there is no gap between the SMARTneo-2G and the Table Top at the mount-
ing points. The Control Box must be tightly secured with no movement possible.
• Ensure the mounting surface is smooth, at, and undamaged.
• Ensure the entire housing of the SMARTneo-2G is placed underneath the Table Top.
• Ensure the Control Box is installed and used within the ambient conditions speci-
ed in the product datasheet.
• If the Light Barrier function is not working properly, contact LOGICDATA.
NOTICE LOGICDATA recommends using the drilling template on page 13 to mark the positions
of the Mounting Screws. If you choose not to do so, pay close attention to the dimen-
sions of the SMARTneo-2G.
1. Position the SMARTneo-2G under the table top and mark the position of the drilling holes. If
necessary, use the Drilling Template on page 13 to help you.
2. Drill the holes into the table top.
3. Use the screwdriver and 2 Mounting Screws to attach the SMARTneo-2G to the Table Top at the
drilled holes.
NOTICE The required tightening torque depends on the material of the Table Top. Do not exceed
2 Nm.
5.4 COMPLETING ASSEMBLY
After the SMARTneo-2G is attached to the Table Top, you must connect the Control Box to the system.
Instructions for this can be found in the next chapter.

SMARTNEO - OPERATING MANUAL // PAGE 16
6 CONNECTING THE SYSTEM
WARNING Moderate risk of death or serious injury through electric shocks
Connecting the system incorrectly can lead to death or serious injury through electric
shocks.
• Ensure that the supplied voltage complies with the SMARTneo-2G's type plate
• Ensure all components are connected to the correct sockets
• Do not use unauthorized accessory parts or cables
• Disconnect the SMARTneo-2G from the power outlet before removing or connect-
ing any components
• Connect the system to the Mains only after all other components (Actuators, User
Interfaces, etc.) have been connected to the SMARTneo-2G
WARNING Moderate risk of death or serious injury through electric shocks
Using damaged products may lead to death or serious injury through electric shocks.
• Do not use the SMARTneo-2G if you see the housing or cables are damaged
NOTICE Ensure proper ESD handling during assembly. Damage that can be attributed to electro-
static discharge will void warranty claims.
INFO Perform a product risk assessment so that you can respond to potential residual haz-
ards. Assembly instructions must be included in your end user Operating Manual
6.1 SYSTEM CONFIGURATION
The SMARTneo-2G can be used to create a variety of Table Systems. This Manual describes the connection of
table systems in which only one Control Box will be connected. For Table Systems with more than one Control
Box, refer to the SMARTneo-2G Cascading Manual for assembly and safety advice. This Manual describes
Table Systems that will be powered using mains electricity. For usage with other types of power source, refer
to the Manual of the chosen product.
6.1.1 REQUIRED COMPONENTS: SYSTEM WITH 1 ACTUATOR
11 SMARTneo-2G Control Box
21 Actuator (e.g. SLIMdrive-500 or SLIMdrive-660s)
31 User interface (see Chapter 6.3)
41 Mains cable (2-pin connection, C8)
6.1.2 REQUIRED COMPONENTS: SYSTEM WITH TWO ACTUATORS
11 SMARTneo-2G Control Box
22 Actuators (e.g. SLIMdrive-500 or SLIMdrive-660s)
31 User interface (see Chapter 6.3)
41 Mains cable (2-pin connection, C8)

SMARTNEO - OPERATING MANUAL // PAGE 17
6.2 CONNECTING ACTUATORS
Plug the Actuator(s) into the designated Plug Port(s) on the SMARTneo-2G (M1/M2 [optional]).
NOTICE Ensure that the Actuator(s) have been safely assembled into the Height-Adjustable
Columns before connecting. Refer to the Actuator's Manual to avoid system damage.
NOTICE If you are connecting two Actuators to the SMARTneo-2G, you must connect the M1
Plug Port before the M2 Port.
6.3 CONNECTING USER INTERFACES
Plug the User Interface into the designated Plug Port on the SMARTneo-2G (HC)
INFO Your Table System must be controlled using a SMARTneo-2G-compatible User
Interface. A User Interface is a general term that covers Hand Controls (Basic and
Comfort) and other products that can control the System, e.g. LOGIClink. Assembly
and Operation dier depending on which type of User Interface will be installed.
Unless otherwise stated, the instructions in this Operating Manual assume that the
user has installed a Table System alongside a Comfort or Basic Hand Control. If you
have purchased a SMARTneo-2G for use alongside a dierent User Interface, you are
obliged to read the Operating Manual of your chosen User Interface in full.
6.4 CASCADING
Cascading is the process of connecting two SMARTneo-2G Control Boxes together in order to control extra
Actuators. Consult the SMARTneo-2G Cascading Manual for further instructions and safety advice.
6.5 EXTERNAL POWER SUPPLIES (OPTIONAL)
The SMARTneo-2G can be powered using compatible, certied, LOGICDATA-approved external Power
Supplies. For instructions and safety advice, refer to that product's Operating Manual.
6.6 CONNECTING TO THE MAINS
WARNING Moderate risk of death or serious injury through electric shocks
Connecting the SMARTneo-2G to the mains incorrectly may lead to death or serious
injury through electric shocks.
• Ensure the mains voltage is compliant with the voltage specied on the
SMARTneo-2G's Type Plate
• Do not attempt to force or bend connectors
1. Plug the Power Cable into the AC Plug Port of the SMARTneo-2G
2. Connect the Power Cable to the mains.
6.7 PERFORMING A POSITION RESET PROCEDURE
CAUTION Risk of minor or moderate injury through crushing
Collision Detection (ISP) is inactive during start-up and reset processes. This may lead
to minor or moderate injury through crushing.
• Ensure that no persons or objects are in the table's range of motion

SMARTNEO - OPERATING MANUAL // PAGE 18
NOTICE Operating the table system when it is not properly connected can damage the product.
• Ensure all Cables are properly connected
• Ensure that all required Actuators are ready to be operated
• Do not operate the Table System until it is properly connected
The Position Reset Procedure is used to align the position of the Actuators within the Table System. You must
perform a Position Reset Procedure before using the SMARTneo-2G for the rst time.
It is possible to perform a Position Reset Procedure with all types of compatible User Interface. However,
this section describes performing a Position Reset Procedure for Table Systems controlled by a Hand Control
with an UP Key and DOWN Key (Comfort or Basic Hand Controls).
If your SMARTneo-2G is operated by a dierent User Interface, consult that product’s operating Manual for
instructions on performing a Position Reset Procedure.
1. Press and hold the DOWN Key until the table stops at the lower position limit
2. Release the DOWN Key
3. Press and hold the DOWN Key again
▸ The table will move down slightly, then up again
4. Release the DOWN Key
▸ The Position Reset Procedure is complete.
INFO If your SMARTneo-2G has been parameterized with additional stopping points (e.g.
a Container Stop Position), repeat Step 3 until the table has moved upwards again.
6.8 CONFIGURATION EXAMPLE
1SMARTneo-2G Control Box
2Actuators (e.g. SLIMdrive-500 or SLIMdrive-660s)
3User interface (see Chapter 6.3)
4Mains cable
M1
M2
HC
AC
SMARTneo
2
3
2
4
1

SMARTNEO - OPERATING MANUAL // PAGE 19
7 OPERATION
CAUTION Risk of minor or moderate injury through uncontrolled movement
The table may not always stop exactly at the expected position. Failure to anticipate the
table's movements may lead to minor or moderate injury through crushing.
• Wait until the system has completely stopped before attempting to use the table
CAUTION Risk of minor or moderate injury through unsecured objects
While the table moves up and down, unsecured objects may fall o the table and onto
body parts. This may lead to minor or moderate injury through crushing.
• Ensure loose objects are kept away from the edge of the table
• Do not leave unnecessary objects on the table during movement
This section of the Operating Manual contains instructions for operating the Table System. All instructions
assume the reader has assembled a Table System that will be controlled by a Hand Control with an UP Key
and DOWN Key. If your Table System is operated by a dierent User Interface, consult that product’s operat-
ing Manual for instructions on operating the Table System. The availability of some functions depends on
the Hand Control used. This section describes two variants:
• Comfort Hand Controls - These products have a digital display and can save Memory Positions
• Basic Hand Controls - These products have only an UP and DOWN key
Hand Control Keys are represented as follows for further description:
UP Key
DOWN Key
SAVE SAVE Key (Comfort Hand Controls only)
1Memory Position Key 1 (Comfort Hand Controls only)
2Memory Position Key 2 (Comfort Hand Controls only)
3Memory Position Key 3 (Comfort Hand Controls only)
4Memory Position Key 4 (Comfort Hand Controls only)
7.1 ADJUSTING THE TABLE TOP HEIGHT
CAUTION Risk of minor or moderate injury through crushing
Your ngers may be crushed when you attempt to change the height of the table
• Keep ngers away from moving parts
• Ensure that no persons or objects are in the table's range of motion

SMARTNEO - OPERATING MANUAL // PAGE 20
INFO The Table Top will move up or down until the UP or DOWN Key is released, or if a pre-de-
ned stopping point has been reached.
To move the Table Top UP:
Press and hold the UP Key until the desired height has been reached
To move the Table Top DOWN:
Press and hold the DOWN Key until the desired height has been reached
7.2 SAVING A MEMORY POSITION
7.2.1 USING A BASIC HAND CONTROL
This function saves a set Table Top position. One "Stand" Memory Position can be saved in the top half of the
range of movement, one "Sit" Memory Position in the bottom half.
1. Move the table to the desired height (Chapter 5.1.1, Adjusting the Table Top height)
2. Press and hold the UP Key and DOWN Key simultaneously ("S" Key if available)
3. Press the UP Key to Save a Standing Position or the DOWN Key to Save a Sitting
Position.
▸ The Memory Position is saved
To delete a Memory Position with a Basic Hand Control, move to the Memory Position you wish to delete and
repeat steps 2 and 3.
7.2.2 USING A COMFORT HAND CONTROL
This function saves a set Table Top position. One Memory Position can be saved per Memory Position Key.
1. Move the table to the desired height (Chapter 5.1.1, Adjusting the Table Top height)
▸ The display shows the Table Top height (e.g. 73 cm)
2. Press the SAVE Key.
3. Press the Memory Position Key (e.g. 2)
▸ The display shows S 2
7 3
SAVE
2
s 2
Other manuals for SMARTneo-2G
1
Table of contents
Other LOGICDATA Control Unit manuals