Loop Telecom Loop-O9500R User manual

1
Loop-O9500R
SDH/SONET IMAP
Description
The Loop-O9500R SDH/SONET IMAP (Integrated
Multi-Services Access Platform) is an economical
STM-1/4/16 (OC-3/12/48) access multiplexer
designed to provide integrated access to STM-1/4/16
(OC-3/12/48) optical lines. Access is provided through
either a non-blocking VC11/VC12/VC3/VC4
cross-connect with HS tributarymodulesor through an
additional non-blocking DS0 cross-connect fabric with
LS tributary modules.
The 6U shelf supports:
4 HS tributary module slots
6 LS tributary module slots
With up to 4 STM-1/4/16 (OC-3/12/48) aggregate
interfaces on cross-connect modules and 8 STM-1
(OC-3) interfaces on tributaries, the Loop-O9500R
SDH/SONET IMAP offers service providers aversatile
protection schemes including SNCP(UPSR) and
MSP(1+1) protection for both ring and linear network
topologies. The O9500R can work with the
Loop-O9100 and Loop-O9400 in the same topology.
The non-blocking VC11/VC12/VC3/VC4 cross-
connect capability on High Speed (HS)is up to 20
VC4. The HS tributary modules include optical
STM-1/4 (OC-3/12), E3/T3, E1/T1 interfaces, FOM
and Fast Ethernet/Gigabit Ethernet over STM-1/4/16
(OC-3/12/48). Ethernet signals are mapped onto STM
payload through standard techniques such as GFP,
LAPS, VCAT, LCAS, and non-LCAS. These HS
modulesare identical to those used in the rack version
of the Loop-O9400.
The uplink non-blocking DS0 cross-connect to HS is
up to 21 E1 or 28 T1. The non-blocking DS0
cross-connect capability on Low Speed (LS) is up to
768 DS0. Through a full non-blocking DS0
cross-connect and together can act as a mini DACS.
The modules include variety of TDM, IP, and voice
interfaces detailed on next page. All LS modules are
identical to those used in rack version of the
Loop-AM3440.
All interfacesarefully compliant withthe relevant ETSI
standards and ITU recommendations. The O9500R
SDH/SONET IMAP provides full Operation,
Administration, Maintenance and Provisioning
(OAM&P) functionality.
Users can easily operate the O9500R locally or
remotely for centralized management with Loop-iNET
(EMS) and Loop-iNMS (Integrated NMS).
Features
6U height, full front access (ETSI) shelf
TM, ADM and DCS (full cross-connect) at DS0,
VC11, VC12, VC3, VC4
Aggregate cross-connect modules (controller
modules)
- Up to STM-1/4/16 (OC-3/12/48) aggregate lines
with software configuration (CC16)
- Up to STM-1/4 (OC-3/12) aggregate lines with
software configuration (CC4)
Hot-swappable cross-connect modules,
tributary modules and power modules.
Tributary Modules (See Table 1 below)
- High-Speed (High Density) access
tributary modules (HS)
- Low-Speed access tributary modules (LS)
Power Modules
- DC Module (-48/-125/-250 Vdc)
- Dual Power (1+1) Protection
Protection Scheme
Tributary protection
- E1/T1: card, port, line
- E3/T3: line
- B155/622: MSP, SNCP/UPSR
- Ethernet
- 7 FOM: line
Cross-connect unit (XCU) protection
- MSP
- SNCP/UPSR
DS0-SNCP protection
External/Internal/Line timing source with SSM
Ethernet supports GFP, LAPS, VCAT, LCAS
and non-LCAS
Ethernet Order Wire (EOW) using VoIP
technology
Alarm suppression, masking and reports
Management
Console port, VT100 menu-driven
SNMP Port
Telnet and SSH
Centralized management with Loop‟s EMS/NMS
over DCC channel
Loop-iNET GUI EMS
TMN management(Loop-iNMS) with full FCAPS
and end-to-end circuit management
RoHS compliant

Loop-O9500 SDH/SONET IMAP
SDH/SONET-MSTP
2
Table 1: Loop-O9500R Tributary Modules
Tributary Type
Plug-in Interface Cards
Maximum Capacity
For STM-1/4 (OC-3/12)
aggregate cross connect module
For STM-1/4/16 (OC-3/12/48)
aggregate cross connect module
on CHAA Chassis
High-Speed
(High Density)
Access Tributary
Modules
(HS)
STM-4 (OC-12) tributaries
1 MSP 1 + 1
2 MSP 1+1 or
2 Sub-ring SNCP or
4 STM-4 without protection
STM-1 (OC-3) tributaries
3 MSP 1 + 1 or
3 Sub-ring SNCP or
6 STM-1 without protection
4 MSP 1+1 or
4 Sub-ring SNCP or
8 STM-1 without protection
63 port E1/T1 tributaries
252 E1/T1 without protection, or 126
E1/T1 with 1+1 card protection
252 E1/T1 without protection, or
126 E1/T1 with 1+1 card protection
32 port E1/T1 tributaries
16 port E1/T1 tributaries
3 port E3/T3 tributaries
12 E3/T3 without protection, or 6
E3/T3 with 1+1 card protection
12 E3/T3 without protection, or
6 E3/T3 with 1+1 card protection
8FE+1GbE EoS card with/ without
built-in L2 switch
32 FE + 4GbE
32 FE + 4GbE
4GbE EoS card with L2 switch *
--
8 GbE
7 port FOM tributaries
28 FOM without protection, or 14
FOM with protection
28 FOM without protection, or
14 FOM with protection
Low-Speed Access
Tributary Modules
(LS)
Low Speed Single-Slot Cards
8-port Bridge/Router
48-port Bridge/Router
4-channel E1/T1
24-channel E1/T1
3-channel E1/T1
18-channel E1/T1 (DS0 SNCP Protection)
2-channel G.SHDSL (2 pairs)
without line power
12-channel G.SHDSL (2 pairs) without line power
4-channel G.SHDSL (1 pairs)
without line power
24-channel G.SHDSL (1 pairs) without line power
8-channel G.703 card at 64 Kbps
data rate
48-channel G.703 card at 64 Kbps data rate
1 or 4 channel C37.94
(low speed optical)
6 or 24 channel C37.94 (low speed optical)
8-channel RS232/V.24
48-channel RS232/V.24
8-channel Dry Contact I/O
48-channel Dry Contact I/O
8-channel Dry Contact I/O type B
48-channel Dry Contact I/O type B
8-channel 2W/4W E&M
48-channel 2W/4W E&M
12-channel FXS
72-channel FXS
12-channel FXO
72-channel FXO
Conference card
Conference card
12-channel Magneto
72-channel Magneto
TDMoE
TDMoE
8-channel Data Bridge
48-channel Data Bridge
8-channel UDTEA
48-channel UDTEA
1 port FOM (1FOMB)
6-port FOM
8-channel OCUDPA
48-channel OCUDPA
6-channel UDTEA*
36-channel UDTEA
Low Speed Dual-Slot Cards
6-channel V.35
18-channel V.35
6-channel V.36
18-channel V.36
6-channel X.21/V.11
18-channel X.21/V.11
6-channel EIA530/RS449
18-channel EIA530/RS449
24-channel FXS
72-channel FXS
24-channel FXO
72-channel FXO
*Future Option
Notes: Single-Slot Cards plug into singles slots; Dual-Slot Cards plug into two adjacent single slots

Loop-O9500 SDH/SONET IMAP
SDH/SONET-MSTP
3
Table 2: Maximum Number of Channels/Ports on Each Plug-in Card (with CC4)
Slot
Plug-in Card
TRIB 1
TRIB 2
TRIB 3
TRIB 4
XCU 1
XCU 2
Trib 11~16
(per card)
Total
E1/T1 (For HS slots)
63
63
63
63
x
x
x
252
E1/T1
E1/T1 (For LS slots)
x
x
x
x
x
x
4E1
4T1
21E1
24T1
E3/T3
3
3
3
3
x
x
x
12 E3/T3
9EoS4SW
(Ethernet)
FE
8
8
8
8
x
x
x
32
GbE
1
1
1
1
x
x
x
4
Optical
(SFP)
STM-1
2
2
1
1
2
2
x
10
2
(B)
STM-4
1
(B)
x
x
2
2
x
5
7FOM (For HS slots)
7
7
7
7
x
x
x
28
1FOMB (For LS slots)
x
x
x
x
x
x
1
6
RTB (Bridge/Router)
x
x
x
x
x
x
8
48
G.SHDSL
x
x
x
x
x
x
2/4
12/24
3 E1/T1 (DS0 SNCP)
x
x
x
x
x
x
3
18
G.703
x
x
x
x
x
x
8
48
C37.94
x
x
x
x
x
x
1/4
4/24
Dry Contact
x
x
x
x
x
x
8
48
Dry Contact type B
x
x
x
x
x
x
8
48
RS232/V.24
x
x
x
x
x
x
8
48
Conference (Note 1)
x
x
x
x
x
x
6
36
12 FXS/FXO
x
x
x
x
x
x
12
72
12 Magneto
x
x
x
x
x
x
12
72
E&M
x
x
x
x
x
x
8
48
V.35/V.36/X.21
x
x
x
x
x
x
6
18
EIA530/RS449
x
x
x
x
x
x
6
18
24 FXS/FXO
x
x
x
x
x
x
24
72
TDMoE
x
x
x
x
x
x
4
24
Data Bridge
x
x
x
x
x
x
8
48
8 UDTEA
x
x
x
x
x
x
8
48
8 OCUDPA
x
x
x
x
x
x
8
48
6 UDTEA*
x
x
x
x
x
x
6
36
*Future Option
X: not applicable
(B) Backup
Note 1: A conference plug-in card contains two RS232 data ports, two FXS ports and two E&M ports.

Loop-O9500 SDH/SONET IMAP
SDH/SONET-MSTP
4
Table 3: Maximum Number of Channels/Ports on Each Plug-in Card (with CC16 on CHAA)
Slot
Plug-in Card
TRIB 1
TRIB 2
TRIB 3
TRIB 4
XCU 1
XCU 2
Trib 11~16
(per card)
Total
E1/T1 (For HS slots)
63
63
63
63
x
x
x
252
E1/T1
E1/T1 (For LS slots)
x
x
x
x
x
x
4E1
4T1
21E1
24T1
E3/T3
3
3
3
3
x
x
x
12 E3/T3
9EoS4SW
(Ethernet)
FE
8
8
8
8
x
x
x
32
GbE
1
1
1
1
x
x
x
4
4GESW*
GbE
x
x
4
4
x
x
x
8
Optical
(SFP)
STM-1
2
2
2
2
2
2
x
12
STM-4
1
1
1
1
2
2
x
8
STM-16
x
x
x
x
2
2
x
4
7FOM (For HS slots)
7
7
7
7
x
x
x
28
1FOMB (For LS slots)
x
x
x
x
x
x
1
6
RTB (Bridge/Router)
x
x
x
x
x
x
8
48
G.SHDSL
x
x
x
x
x
x
2/4
12/24
3 E1/T1 (DS0 SNCP)
x
x
x
x
x
x
3
18
G.703
x
x
x
x
x
x
8
48
C37.94
x
x
x
x
x
x
1/4
4/24
Dry Contact
x
x
x
x
x
x
8
48
Dry Contact type B
x
x
x
x
x
x
8
48
RS232/V.24
x
x
x
x
x
x
8
48
Conference (Note 1)
x
x
x
x
x
x
6
36
12 FXS/FXO
x
x
x
x
x
x
12
72
12 Magneto
x
x
x
x
x
x
12
72
E&M
x
x
x
x
x
x
8
48
V.35/V.36/X.21
x
x
x
x
x
x
6
18
EIA530/RS449
x
x
x
x
x
x
6
18
24 FXS/FXO
x
x
x
x
x
x
24
72
TDMoE
x
x
x
x
x
x
4
24
Data Bridge
x
x
x
x
x
x
8
48
8 UDTEA
x
x
x
x
x
x
8
48
8 OCUDPA
x
x
x
x
x
x
8
48
6 UDTEA*
x
x
x
x
x
x
6
36
*Future Option
X: not applicable
(B) Backup
Note 1: A conference plug-in card contains two RS232 data ports, two FXS ports and two E&M ports.

Loop-O9500 SDH/SONET IMAP
SDH/SONET-MSTP
5
Ordering Information
Note: RoHS compliant units are identified by the letter G appearing immediately at the end of the ordering code.
Model
Description
Notes
Main Unit
Loop-O9500-R-CHA-G
6U height Rack chassis for O9500R
without CPU and power
Loop-O9500-R-CHAA-G
6U height Rack chassis support up to 2.5G Mbps
mapping bandwidth for O9500R
without CPU and power
Controller Modules (CPU)
Loop-O9500-R-CC16-G
Controller module with cross-connect unit and
two STM-1/4/16 (OC-3/12/48) interfaces
without SFP (mini-GBIC) optical modules
·Order two for redundancy.
·Please order SFP optical modules
separately from SFP optical
modules brochure
·Use with Loop-O9500-R-CHAA-G
Loop-O9500-R-CC4-G
Controller module with cross-connect unit and
two STM-1/4 (OC-3/12) interfaces
without SFP (mini-GBIC) optical modules
·Order two for redundancy.
·Please order SFP optical modules
separately from SFP optical
modules brochure
·Use with Loop-O9500-R-CHA-G or
Loop-O9500-R-CHAA-G
Connector Board and Fan Modules
Loop-O9500-R-CBA-G
Connector Board
·CBA or CBB is required for each
chassis.
·If you need order wire function in
CBA, please purchase order wire
phone: Loop-O9500-R-OW under
accessory section.
Loop-O9500-R-CBB-G
Connector Board with EoW using VoIP
technology
·CBA or CBB is required for each
chassis.
·You can use regular analog phone
for order wire function in CBB.
Loop-O9500-R-FANA-G
Fan Board
·One required for each chassis.
High Speed or High Density Tributary Modules
Loop-O9500-R-16TE-G
16 E1 (120 ohm) or 16 T1 software
programmable plug-in card
·The 16/32/63TEmodules can also
be used in the Loop-O9400R.
Loop-O9500-R-32TE-G
32 E1 (120 ohm) or 32 T1 software
programmable plug-in card
Loop-O9500-R-63TE-G
63 E1 (120 ohm) or 63 T1 software
programmable plug-in card
Loop-O9500-R-16E75-G
16 E1(75 ohm) plug-in card
·The 16/32/63E75 modules can also
be used in the Loop-O9400R.
Loop-O9500-R-32E75-G
32 E1(75 ohm) plug-in card
Loop-O9500-R-63E75-G
63 E1(75 ohm) plug-in card
Loop-O9500-R-3TE3-G
3 T3 or 3 E3 software programmable interface
plug-in card
·The 3TE3 and 3TE3M13 modules
can also be used in the
Loop-O9400R.
Loop-O9500-R-3TE3M13-G
3 T3 or 3 E3 software programmable interface
plug-in modules with M13 /Mx3 function for T3
interface only
Loop-O9500-R-7FOM-G
7-port Fiber Optical Interface with 7 SFP
housings (SFP not included)
·This card can also be used in the
Loop-O9400R.
·Please order SFP optical modules
separately from SFP optical
modules brochure

Loop-O9500 SDH/SONET IMAP
SDH/SONET-MSTP
6
Loop-09500-R-9EoS4NSW-G
1 GbE or 8FE software programmable plug-in
card without L2 switch
·This card can also be used in the
Loop-O9400R.
Loop-O9500-R-9EoS4SW-G
1GbE and 8FE plug-in card with L2 switch
·This card can also be used in the
Loop-O9400R.
Loop-O9500-R-B16-G
STM-1/4 (OC-3/12) software configurable p
lug-in card without SFP (mini-GBIC) optical
modules
·This card can also be used in the
Loop-O9400R.
Loop-O9500-R-4GESW-G*
4 GbE card with 2 combo and 2 optical
(10/100/1000BaseT) interface plug-in module
with L2 switch
·Use with Loop-O9500-R-CC16-G
controller module only
·Use with Loop-O9500-R-CHAA-G
chassis‟tributary slot 3 and 4 only.
*Future Option
Low Speed Tributary Modules (Single Slot)
Loop-O9500-R-4E1-cc-G
4-channel E1 plug-in card.
·This card can also be used in the
Loop-AM3440-A/B/C.
·For cc option, please refer to the
table below for detail information
Loop-O9500-R-4T1-G
4-channel T1 plug-in card
·This card can also be used in the
Loop-AM3440-A/B/C.
Loop- O9500-R-3E1-cc-G
3-channel E1 plug-in card with DS0 (64K bps)
SNCP protection
·For cc option, please refer to the
table below for detail information
This card can also be used in the
Loop-AM3440-A/B/C
Loop-O9500-R-3T1-G
3-channel T1 Interface
·For software version 3.02.01 or
newer versions.
·This card can also be used in the
Loop-AM3440-A/B/C
Loop-O9500-R-2GH-G
2-channel G.SHDSL plug-in card (2 pair)
·This card can also be used in the
Loop-AM3440-A/B/C.
Loop-O9500-R-4GH-G
4-channel G.SHDSL plug-in card (1 pair)
·This card can also be used in the
Loop-AM3440-A /B/C.
Loop-O9500-R-8DC-G
8-channel dry contact plug-in card with
maximum voltage 100 Vdc or 250 Vac
·This card can also be used in the
Loop-AM3440-A /B/C.
Loop- O9500-R-8DCB-G
8-channel dry contact type B plug-in card with
maximum voltage 220 Vdc or 250 Vac
·This card can also be used in the
Loop-AM3440-A /B/C.
Loop-O9500-R-8CD-G
8-channel G.703 plug-in card at 64 Kbps data
rate
·This card can also be used in the
Loop-AM3440-A /B/C.
Loop-O9500-R-1C37- LSFOM –G
1- channel C37.94 plug-in card
·For LSFOM option, please refer to
the table below for detail
information
·This card can also be used in the
Loop-AM3440-A /B/C.
Loop-O9500-R-4C37- LSFOM –G
4- channel C37.94 plug-in card
Loop-O9500-R-8RS232-RJ-G
8-port RS232 plug-in card with X.50 subrate
multiplexing scheme and X.54 encoding, with
8 RJ48 connectors for 8 RS232 Async ports
·This card can also be used in the
Loop-AM3440-A /B/C.
Loop-O9500-R-8RS232-DB-G
8-port RS232 plug-in card with X.50 subrate
multiplexing scheme and X.54 encoding, with
2RJ48 connectors and 2 DB44 connectors for
Async and Sync ports
·Two conversion cables are
included. (Each cable has one
DB44 connector to one DB9 and
two DB25 connectors).
·This card can also be used in the
Loop-AM3440-A /B/C.
Loop-O9500-R-8DBRA-RJ-G
8-channel data bridge plug-in card, with 8
RJ48 connectors for 8 data bridge Async
ports
·This card can also be used in the
Loop-AM3440-A/B/C
Loop-O9500-R-8DBRA-DB-G
8-channel data bridge plug-in card, with 2
RJ48 connectors and 2DB44 connectors for 8
data bridge Async ports
·Two conversion cables are
included (DB44 connector to two
DB25 and one DB9 connector;
(Loop-ACC-CAB-DB44M-100-
2DB25F-1DB09F-DB).

Loop-O9500 SDH/SONET IMAP
SDH/SONET-MSTP
7
Loop-O9500-R-RTB-G
8-LAN port/64 WAN ports router/bridge
plug-in card
·This card can also be used in the
·Loop-AM3440-A/B/C.
Loop-O9500-R-CONF-G
Conference plug-in card with two RS232 data
ports, two FXS ports and two E&M ports
·This card can also be used in the
Loop-AM3440-A/B/C.
Loop-O9500-R-TDMoE-PPM-G
TDMoE card with 2 GbE combo interfaces
and 2 Ethernet interfaces
(10/100/1000BaseT) plug-in module.
Support G.823 Traffic
·The SFP module is not included in
the TDMoE card.
·Please order separately for SFP
optical modules from SFP optical
brochure
·This card can also be used in the
Loop-AM3440-A/B/C
Loop-O9500-R-8UDTEA-opm-G
8-port universal data interface card that
supports RS232/RS422/RS485 DCE
interface which is software configurable
Available option mode: Terminal Server
and/or Omnibus
·For opm option, please refer to
the table below for detail
information.
·This card can also be used in the
Loop-AM3440-A/B/C
Loop-O9500-R-8EM-x-G
8-channel 2W/4W E&M plug-in card with 8
RJ45
·“8EM”card with H/W ver. F (and
later versions), F/W V4.01.01 (and
later versions) can also be used in
the Loop-AM3440-A /B/C.
·For xoption, please refer to the
table below.
Loop-O9500-R-12MAG-1G-x-G
12-channel Magneto plug-in module w/ L1.
GND
·12MAG-1G2 includes all function
of MAG cards.
·For xoption, please refer to the
table below for detail information.
·This card can also be used in the
Loop-AM3440-A/B/C
Loop-O9500-R-12MAG-12-x-G
12-channel Magneto plug-in module w/ L1,L2
Loop-O9500-R-12MAG-1G2-x-G
12-channel Magneto plug-in module w/ L1,L2
and L1. GND
Loop-O9500-R-12MAG-A-1G-x-G
12-channel Magneto ring-one-time plug-in
module w/ L1. GND
·12MAG-A-1G2 includes all
function of 12MAG-A cards.
·This card can also be used in the
Loop-AM3440-A/B/C
Loop-O9500-R-12MAG-A-12-x-G
12-channel Magneto ring-one-time plug-in
module w/ L1, L2
Loop-O9500-R-12MAG-A-1G2-x-G
12-channel Magneto ring-one-time plug-in
module w/ L1, L2, and L1. GND
Loop-O9500-R-12FXS- sn-pt-G
12-channel FXS plug-in card with 600/ 900
Impedance, Battery Reverse, PLAR, without
Ground Start and Metering Pulse. Used with
12 RJ11.
·12FXS-GMP includes all FXS
Card functions.
·“12FXS-x”cards with H/W ver. L
and F/W V.3.01.01 or newer
versions.
·It can also be used in the
Loop-AM3440-A /B/C
·For sn option, please refer to the
table below for detail information.
·pt= power type
·For pt option, please refer to the
table below for detail information
Loop-O9500-R-12FXS-P-sn-pt-G
12-channel FXS plug-in card with 600/ 900
Impedance, Battery Reverse, PLAR, without
Ground Start and Metering Pulse PLAR bit
programmable function. Used with 12 RJ11.
Loop-O9500-R-12FXS-M-pt-G
12-channel FXS plug-in card with 600/ 900
Impedance, Battery Reverse, PLAR,
[Metering Pulse]. Used with 12 RJ11.
Loop-O9500-R-12FXS-MPP-pt-G
12-channel FXS plug-in card with 600/ 900
Impedance, Battery Reverse, PLAR and
PLAR bit programmable function, [Metering
Pulse]. Used with 12 RJ11.
Loop-O9500-R-12FXS-GS-pt-G
12-channel FXS plug-in card with 600/ 900
Impedance, Battery Reverse, PLAR, [Ground
Start] . Used with 12 RJ11.
Loop-O9500-R-12FXS-GM-pt-G
12-channel FXS plug-in card with 600/ 900
Impedance, Battery Reverse, PLAR, [Ground
Start, and Metering Pulse]. Used with 12
RJ11.
Loop-O9500-R-12FXS-GMP-pt-G
12-channel FXS plug-in card with 600/ 900
Impedance, Battery Reverse, PLAR and
PLAR bit programmable function, [Ground
Start, and Metering Pulse]. Used with 12
RJ11.

Loop-O9500 SDH/SONET IMAP
SDH/SONET-MSTP
8
Loop-O9500-R-12FXO-G
12-channel FXO plug-in card with 600/ 900
Impedance, Battery Reverse, without Ground
Start and Metering Pulse. Used with 12 RJ11.
·12FXO-GM includes all FXO Card
functions.
·“12FXO-x”cards with H/W ver. G
and F/W V2.01.01 or newer
versions. It can also be used in
the AM3440-A /B/C
Loop-O9500-R-12FXO-M-G
12-channel FXO plug-in card with 600/ 900
Impedance, Battery Reverse, [ Metering
Pulse ] Used with 12 RJ11.
Loop-O9500-R-12FXO-GS-G
12-channel FXO plug-in card with 600/ 900
Impedance, Battery Reverse, [ Ground Start ]
Used with 12 RJ11.
Loop-O9500-R-12FXO-GM-G
12-channel FXO plug-in card with 600/ 900
Impedance, Battery Reverse, [ Ground Start,
and Metering Pulse ] Used with 12 RJ11.
Loop-O9500-R-1FOMB-opt-G
1FOMB Fiber Optical Interface with 1x9
optical port
·For opt option, please refer to the
table below for detail information
·This card can also be used in the
Loop-AM3440-A/B/C
Loop-O9500-R-OCUDPA
8-channel OCU-DP plug-in module
·Only non-RoHS compliant model
available
·Not for AM3440 Series
Low Speed Tributary Modules (Dual Slots)
Loop-O9500-R-6X21A-G
6-channel X.21/V.11 card with DB15
connector
·These cards will occupy two slots.
·These cards can also be used in
the Loop-AM3440-A /B/C.
Loop-O9500-R -6V35A-G
6-channel V.35 plug-in card with DB25S
connector, for M34. (2Mbits per channel)
Please order conversion cable connector
below.
Loop-O9500-R -6V36A-G
6-channel V.36 card with DB25 connector via
conversion cable to DB37
Loop-O9500-R-6E530A-G
6-channel EIA530 plug-in card with DB25
connector
Loop-O9500-R-6RS449A-G
6-channel EIA530/RS449 plug-in card with
DB25 connector via conversion cable to DB37
Loop-O9500-R-24FXS-sn-pt-G
24-channel FXS plug-in card with 600/900
Impedance, Battery Reverse, Loop Start and
PLARWithoutGround Start and Metering Pulse
·24FXS-GMP includes all FXS card
functions.
·These cards will occupy two slots.
·These cards can also be used in
the Loop-AM3440-A /B/C
·For sn option, please refer to the
table below for detail information
·For pt option, please refer to the
table below for detail information
Loop-O9500-R-24FXS-P-sn-pt-G
24-channel FXS plug-in card with 600/900
Impedance, Battery Reverse, Loop Start, PLAR
and [PLAR bit programmable].
Without Ground Start and Metering Pulse
Loop-O9500-R-24FXS-M-pt-G
24-channel FXS plug-in card with 600/900
Impedance, Battery Reverse,
Loop Start, PLAR and [Metering Pulse].
Loop-O9500-R-24FXS-MPP-pt-G
24-channel FXS plug-in card with 600/900
Impedance, Battery Reverse, Loop Start, PLAR,
[PLAR bit programmable] and [Metering Pulse].
Loop-O9500-R-24FXS-GS-pt-G
24-channel FXS plug-in card with 600/900
Impedance, Battery Reverse, Loop Start, PLAR
and [Ground Start].
Loop-O9500-R-24FXS-GM-pt-G
24-channel FXS plug-in card e with 600/900
Impedance, Battery Reverse, Loop Start, PLAR,
[Ground Start] and [Metering Pulse].
Loop-O9500-R-24FXS-GMP-pt-G
24-channel FXS plug-in card with 600/900
Impedance, Battery Reverse, Loop Start, PLAR,
[PLAR bit programmable], [Ground Start] and
[Metering Pulse].
Loop-O9500-R-24FXO-G
24-channel FXO plug-in card with 600/900
Impedance, Battery Reverse and Loop Start.
·24FXO-GM includes all FXO card

Loop-O9500 SDH/SONET IMAP
SDH/SONET-MSTP
9
Without Ground Start and Metering Pulse
functions.
·These cards will occupy two slots.
·These cards can also be used in
the Loop-AM3440-A /B/C
Loop-O9500-R-24FXO-M-G
24-channel FXO plug-in card with 600/900
Impedance, Battery Reverse, Loop Start and
[Metering Pulse].
Loop- O9500-R-24FXO-GS-G
24-channel FXO plug-in card with 600/900
Impedance, Battery Reverse, Loop Start and
[Ground Start].
Loop- O9500-R-24FXO-GM-G
24-channel FXO plug-in card with 600/900
Impedance, Battery Reverse, Loop Start,
[Ground Start] and [Metering Pulse].
Feature Activation License
Loop-O9500-R-3M13
Feature Activation License for O9500-R 3TE3 module
to support M13/Mx3 function for T3 interface only
·Use with 3TE3 HS tributary
module
Loop-O9500-R-ERING
Feature Activation License for O9500-R controller
module to support framed E1 PDH-Ring function
·Use with 4E1 or FOM LS tributary
modules
Loop-O9500-R-TRING
Feature Activation License for O9500-R controller
module to support framed T1 PDH-Ring function
·Use with 4T1 LS tributary modules
Accessories
SFP Optical Modules
Please place your order using the 5-digit alphanumeric codes listed in the separate SFPOptical Module Brochure.
User’s Manual
Loop-O9500-R-UMA
Optional, paper copy of User Manual. ACD version of the manual is already included
as standard package.
Power Modules
Loop-O9500-R-SD48-G
Single power module -48Vdc
·For redundancy purposes, order 2
single DC.
Loop-O9500-R-SD48/125-G
Single power module (300W) Input,
48Vdc/125Vdc (36 to 140Vdc)
·For redundancy purposes, order 2
single DC.
Loop-O9500-R-SD125/250-G
Single power module (300W)
Input 125Vdc/250Vdc (100 to 260Vdc)
·For redundancy purposes, order 2
single DC.
Power Adaptor (All power adaptor are RoHS compliant)
Loop-ACC-APA-240-G
240 Watt, AC (100 to 120 Vac, 5.0A/200 to 240
Vac, 2.5A auto sensing) to DC (-48 Vdc, 5A)
adaptor for USA
·This power adaptor is only for
Loop-O9500-R-SD48.
Loop-ACC-APE-240-G
240 Watt, AC (100 to 120 Vac, 5.0A/200 to 240
Vac, 2.5A auto sensing) to DC (-48 Vdc, 5A)
adaptor for Europe
Loop-ACC-APU-240-G
240 Watt, AC (100 to 120 Vac, 5.0A/200 to 240
Vac, 2.5A auto sensing) to DC (-48 Vdc, 5A)
adaptor for UK
FXO BOX
Loop-ACC-FXOBOX
Support FXO Interface Feed
Order wire phone is an option for CBA board
Loop-O9500-R-OW-USA-G
Ethernet Order Wire phone (using VoIP
technology) with America power plug
Loop-O9500-R-OW-EU-G
Ethernet Order Wire phone (using VoIP
technology) with Europe power plug
SIP Proxy Server
Loop-O9500-R-SIP
SIP Proxy Server Basic Software
Note: One SIP Proxy Server License supports up
to 25 phone lines. Multiple licenses must be
purchased if the number of phone lines exceeds
25.
·Customer must provide a MAC
address so that a license key can
be generated to operate the
software at that address.
Mounting Ear
19”/23”ear mounts
A pair of 19”/23”ear mounts is supplied as part of standard package.
Note: For other sizes, please contact your nearest Loop sales representative.

Loop-O9500 SDH/SONET IMAP
SDH/SONET-MSTP
10
Conversion Panels
Loop-ACC-P-1SCSI-16RJ-G
1u panel for one SCSI to 16 RJ connectors
without cable
432x44x23mm (WxHxD)
·Use with 16/32/63TE HS tributary
modules
·This panel can also be used in the
Loop-O9400R.
Loop-ACC-P-1SCSI-16WW-G
1u panel for one SCSI to 16 Wire Wrap
connectors without cable
432x44x40mm (WxHxD)
·Use with 16/32/63TE or
16/32/63E75 HS tributary modules
·This panel can also be used in the
Loop-O9400R.
Loop-ACC-P-1SCSI-16BNC-G
1.5u panel for one SCSI to 16 BNC connectors
without cable
432x66x53mm (WxHxD)
·Use with 16/32/63E75 HS tributary
modules
·This panel can also be used in the
Loop-O9400R.
Y-box Panels for 120/100 ohm
Y-Box
(120/100 ohm)
E1 (120 ohm) or T1
(SCSI)
E1 (120 ohm) or T1
(SCSI)
E1 (120 ohm) or T1
(RJ, Wire Wrap, TELCO 50, or TELCO 64)
Loop-ACC-Y-2SCSI-16RJ-G
1u Y-box 16-port panel for two SCSI (E1(120
ohm) or T1) to 16 RJ (E1(120 ohm) or T1)
connectors without cable
Use with Loop-O9500-R-16TE-G
Loop-ACC-Y-2SCSI–16WW-G
1u Y-box 16-port panel for two SCSI (E1(120
ohm) or T1) to 16 WireWrap (E1(120 ohm) or
T1) without cable
Use with Loop-O9500-R-16TE-G
Loop-ACC-Y-2SCSI-
2T50P8-16TE-G
1u 16-port Y-box panel in (E1(120 ohm) or
T1) for two SCSI to two TELCO 50 (E1(120
ohm) or T1) connectors (8 ports per TELCO
connector) without cable
Use with Loop-O9500-R-16TE-G
Loop-ACC-Y-2SCSI-
2T50P12-16TE-G
1u 16-port Y-box panel in (E1(120 ohm) or
T1) for two SCSI to twoTELCO 50 (E1(120
ohm) or T1) connectors (12 ports to the first
TELCO connector, 4 ports to the second
TELCO connector ) without cable
Use with Loop-O9500-R-16TE-G
Loop-ACC-Y-2SCSI-
1T64P16-16TE-G
1u 16-port Y-box panel in (E1(120 ohm) or
T1) for two SCSI to one TELCO 64 (E1(120
ohm) or T1) connectors (16 ports per TELCO
connector) without cable
Use with Loop-O9500-R-16TE-G
Loop-ACC-Y-4SCSI-
4T50P8-32TE-G
1u 32-port Y-box panel in (E1(120 ohm) or
T1) for four SCSI to four TELCO 50 (E1(120
ohm) or T1) connectors (8 ports per TELCO
connector) without cable
Use with Loop-O9500-R-32TE-G or
Loop-O9400-R-63TE-G
Loop-ACC-Y-4SCSI-
3T50P12-32TE-G
1u 32-port Y-box panel in (E1(120 ohm) or
T1) for four SCSI to three TELCO 50 (E1(120
ohm) or T1) connectors (12 ports to the first
TELCO connector, 12 ports to the second
TELCO connector and 8 ports to the third
TELCO connector) without cable
Use with Loop-O9500-R-32TE-G or
Loop-O9400-R-63TE-G
Loop-ACC-Y-4SCSI-
2T64P16-32TE-G
1u 32-port Y-box panel in E1 120 ohm or T1
for four SCSIto two TELCO 64 (E1(120 ohm)
or T1) connectors (16 ports per TELCO
connector) without cable
Use with Loop-O9500-R-32TE-G or
Loop-O9400-R-63TE-G

Loop-O9500 SDH/SONET IMAP
SDH/SONET-MSTP
11
Y-box Panels for 75 ohm
Y-Box
(75 ohm)
E1 (120 ohm)
(SCSI)
E1 (120 ohm)
(SCSI)
E1 (75 ohm)
(TELCO 50, or TELCO 64)
Loop-ACC-Y-2SCSI-
2T50P8-16E75-G
1u 16-port Y-box panel for two SCSI (E1(120
ohm)) to two TELCO 50 (E1(75 ohm))
connectors (8 ports per TELCO connector)
without cable
Use with Loop-O9500-R-16TE-G
Loop-ACC-Y-2SCSI-
2T50P12-16E75-G
1u 16-port Y-box panel for two SCSI (E1(120
ohm)) to two TELCO 50 (E1(75
ohm))connectors(12 portsto thefirst TELCO
connector, 4 ports to the second TELCO)
straight without cable
Use with Loop-O9500-R-32TE-G or
Loop-O9500-R-63TE-G
Loop-ACC-Y-2SCSI-
1T64P16-16E75-G
1u 16-port Y-box panel for two SCSI (E1(120
ohm)) to one TELCO 64 (E1(75
ohm))connectors (16 ports per TELCO
connector) straight without cable
Use with Loop-O9500-R-16TE-G
Loop-ACC-Y-4SCSI-
4T50P8-32E75-G
1u 32-port Y-box panel for four SCSI (E1(120
ohm)) to four TELCO 50 (E1(75
ohm))connectors (8 ports per TELCO
connector) without cable
Use with Loop-O9500-R-16TE-G
Loop-ACC-Y-4SCSI-
3T50P12-32E75-G
1u 32-port Y-box panel for four SCSI (E1(120
ohm)) to three TELCO 50 (E1(75
ohm))connectors(12 portsto thefirst TELCO
connector, 12 ports to the second TELCO
connector and 8 ports to the third TELCO
connector) without cable
Use with Loop-O9500-R-32TE-G or
Loop-O9500-R-63TE-G
Loop-ACC-Y-4SCSI-
2T64P16-32E75-G
1u 32-port Y-box panel for four SCSI(E1(120
ohm)) to two TELCO 64 (E1(75
ohm))connectors (16 ports per TELCO
connector) without cable
Use with Loop-O9500-R-32TE-G or
Loop-O9500-R-63TE-G
Y-Box (All Y-Box are RoHS compliant)
Loop-VV-B-G
1 for 1 protection Y-Box with BNC connectors
(4-E1)
Use with Loop-O9500-R-4E1-BNC-G
Loop-VV-R-G
1 for 1 protection Y-Box with RJ48C connectors
(16-E1)
Use with Loop-O9500-R-4E1-RJ-G
Loop-VV-T-G
1 for 1 protection Y-Box with RJ48C connectors
(16-T1)
Use with Loop-O9500-R-4T1-G
Conversion Cables (All conversion cables are RoHS compliant)
Loop-ACC-CAB-SCSI68M-200-
1SCSI68M-G
SCSI 68 pin/Male to SCSI 68 pin/Male
Extension Cable Length:200cm
Used in Loop-O9500-R Y-box panels and
conversion panels
Loop-ACC-CAB-DB44M-
100-2DB25F-1DB09F-DB
DSUB-44 pin/Male to two DSUB-25
pin/Female- one DSBU-9 pin/Female
Length 100cm
Used in Loop-O9500-R-8RS232-DB-G
Loop-O9500-R-8DBRA-DB-Gplug-in card
Loop-ACC-CAB-DB25M-30-1M
34F
DSUB-25pin/Male to M34/Female V.35
Conversion cable
Length: 30 cm
Used in Loop-O9500-R-6V35A-Gplug-in
card
Loop-ACC-CAB-DB25M-30-1D
B37F
DSUB-25pin/Male to DSUB-37/Female
RS449 Conversion cable Length: 30 cm
Used in Loop-O9500-R-6V36A-Gand
Loop-O9500-R-6R449A-Gplug-in cards
Blank Panels
30.001397.A00LF
Blank panel for CPU slot
30.001076.A00LF
Blank panel for power supply slots
Same as that used on O9400R.
30.001077.A00LF
Blank panel for High-speed slots (Slots 1~4)
Same as that used on O9400R.
30.001027.A00LF
Blank Panel for Low-speed slots (Slots
11~16)
Same as that used onAM3440-A.

Loop-O9500 SDH/SONET IMAP
SDH/SONET-MSTP
12
For 4E1 and 3E1 card:
Where cc is used to select connector:
cc =
Description
Notes
RJ
RJ48C connector
BNC
BNC connector
For 8UDTEA card:
Where opm is used to select 8UDTEA functions:
opm =
Description
DCE
Support RS232/RS422/RS485 DCE interface which is software configurable
TS
Support Terminal Server Function and DCE
OMNI
Support Omnibus Function and DCE
CPT
Support Clock Pass Through function and DCE
TSOMNI
Support Terminal Server, Omnibus Function and DCE
HD
Support RS232/RS422/RS485 DCE interface with Full- and Half-Duplex modes
TSHD
Support Terminal Server Function and DCE with Full- and Half-Duplex modes
OMNIHD
Support Omnibus Function and DCE with Full- and Half-Duplex modes
TSOMNIHD
Support Terminal Server, Omnibus Function and DCE with Full- and Half-Duplex
modes
Feature Activation License
Description
Loop-AM3440-8UDTEA-UPGR-TS
Feature Activation License for AM3440 8UDTE card to support Terminal Server
function
Loop-AM3440-8UDTEA-UPGR- OMNI
Feature Activation License for AM3440 8UDTE card to support Omnibus function
Loop-AM3440-8UDTEA-UPGR-CPT
Feature Activation License for AM3440 8UDTE card to support Clock Pass
Through function
Loop-AM3440-8UDTEA-UPGR-TSOM
NI
Feature Activation License for AM3440 8UDTE card to support Terminal Server
function and Omnibus function
Loop-AM3440-8UDTEA-UPGR-HD
Feature Activation License for AM3440 8UDTE card to support Full- and
Half-Duplex modes
Loop-AM3440-8UDTEA-UPGR-TSHD
Feature Activation License for AM3440 8UDTE card to support Terminal Server
function with Full- and Half-Duplex modes
Loop-AM3440-8UDTEA-UPGR-OMNI
HD
Feature Activation License for AM3440 8UDTE card to support Omnibus function
with Full- and Half-Duplex modes
Loop-AM3440-8UDTEA-UPGR-TSOM
NIHD
Feature Activation License for AM3440 8UDTE card to support Terminal Server
function and Omnibus function with Full- and Half-Duplex modes
For 1FOMB Card:
where opt is used to select optical module type:
opt =
Description
Notes
SAA
single optical module with dual uni-directional fiber, 1310 nm,
SC optical connector, 30 km- S1.1 physical layer*
Use 2 fibers
* ITU-T Rec G.957 application
code
SBB
single optical module with dual uni-directional fiber, 1310 nm,
SC optical connector, 50 km - L1.1 physical layer*
SCC
single optical module with dual uni-directional fiber, 1310 nm,
FC optical connector, 30 km - S1.1 physical layer*
SDD
single optical module with dual uni-directional fiber, 1550 nm,
SC optical connector, 20 km - S1.2 physical layer*
SEE
single optical module with dual uni-directional fiber, 1550 nm,
SC optical connector, 100 km - L1.2 physical layer*
SSM
single optical module with single bi-directional fiber (master),
1310 nm transmit and 1550 receive, SC optical connector,
30 km reach - S1.1/ S1.2 physical layer*
1310 nm from master to slave
Order SSM to use with SSS
Use 1 fiber
* ITU-T Rec G.957 application
code
SSS
single optical module with single bi-directional fiber (slave),
1310 nm receive and 1550 transmit, SC optical connector,
30 km reach - S1.1/ S1.2 physical layer*
1550 nm from slave to master
Order SSS to use with SSM
Use 1 fiber
* ITU-T Rec G.957 application
code
NOTE: For other special optical modules, please contact your nearest Loop sales representative.

Loop-O9500 SDH/SONET IMAP
SDH/SONET-MSTP
13
For 8-channel 2W/4W E&M card:
Where x is used to select all of voice card signaling bits. If this option is not required, omit the xfield intheordering code.
8EM
x=
Description
Note
E
Follows ETSI signaling bits
A
FollowsANSI signaling bits
Jumper selectablefor all channels
R
Reverse for ON-HOOK and OFF-HOOK signaling bits
exchange
AR
FollowsANSI signaling bits and reverse bit
S
Follows customer‟s special bit or function assignment
S4
Disable the function of the test button
S5
Forcing all ports to be OFF-HOOK when an alarm occurs
S6
Forcing all ports to be ON-HOOK when an alarm occurs
Note:
1. For S (customer„s special bit), please contact your nearest Loop sales representative.
2. If x is not selected from table above, the default setting for signaling bits is ETSI and for trunk condition is ON-HOOK.
For 12/24-channel FXS card:
Where sn is used to select special function. If this option is not required, omit the sn field in the ordering code.
sn =
Description
Note
sn = omit
FXS Loop Feed = -48 Vdc with 25 mA current limit; alarm tone enable;
normal ring
S1
FXS Loop Feed = -48 Vdc with 35 mA current limit
S4
Remove alarm tone
S5
Double ring tone transmit
Note: For sn (special function), please contact your nearest Loop sales representative.
Where pt is used to select the following functions.
pt=
Description
Note
PWR
For AM3440-Awith -48Vdc (SD, S5), or -125Vdc (SD125) power modules
For AM3440-B/C with -48Vdc (SDB), or AC (SAB) power modules
PWRIE1613
For AM3440-A with -48Vdc (S5) power complied with IEEE1613 standard
For AM3440-C with -48Vdc (SDB) power complied with IEEE1613 standard
For AM3440-A/C
24
For AM3440-A with -24Vdc (S524) power module
Only for 12/24-channel
FXS
For Magneto Card:
Where x is used to select version type:
x=
Description
Note
16
16 Hz ring generator
20 Hz is the general setting for all
MAG cards. For special settings
(16, 25, 50), please specify your
need by filling in the x option.
20
20 Hz ring generator
25
25 Hz ring generator
50
50 Hz ring generator
For C37.94 Card:
Where LSFOM is to select LS-Fiber Optical Module option, each module has 5 letters.
LSFOM
Description
Notes
Code
Mode
Data Rate
Wave Length
Distance
Connector
Code
Description
Code
Description
Code
Description
Code
Description
Code
Description
ZHHTT
Z
Multi-mode
H
155 M
H
820nm
T
2km
T
ST
connector
1 * 8
Separate
transceiver
& receiver
QHATT
Q
Multi-mode
H
155 M
A
850nm
T
2km
T
ST
connector
1 * 9
NFB3T
N
Single mode
F
125 M
B
1310nm
3
30km
T
ST
connector
QFBTT
Q
Multi-mode
F
125 M
B
1310nm
T
2km
T
ST
connector

Loop-O9500 SDH/SONET IMAP
SDH/SONET-MSTP
14
NHC2S
N
Single mode
H
155 M
C
1550nm
2
20km
S
SC
connector
NHCUS
N
Single mode
H
155 M
C
1550nm
U
100km
S
SC
connector
Firmware Upgrade
Loop-O9500-card
-FWUPGR
Firmware Upgrade and Warranty Renewal.
The Customer whose warranty has lapsed or desire to havea firmware
upgrade can purchase this option.
This will upgrade the firmware to the most current version and provide
an additional 12 months of support.
For available card types, please
refer to the table below for detail
information.
For Firmware Upgrade:
Where card is used to select card type:
card=
Description
Note
CC4
CPU card
16TE
16 E1 (120 ohm) or 16 T1 software programmable plug-in card
32TE-G
32 E1 (120 ohm) or 32 T1 software programmable plug-in card
63TE
63 E1 (120 ohm) or 63 T1 software programmable plug-in card
16E75
16 E1(75 ohm) plug-in card
R-32E75
32 E1(75 ohm) plug-in card
63E75
63 E1(75 ohm) plug-in card
B16
STM-1/4 (OC-3/12) software configurable p lug-in card without SFP
(mini-GBIC) optical modules
9EoS4NSW
1 GbE or 8FE software programmable plug-in card without L2 switch
9EoS4SW
1GbE and 8FE plug-in card with L2 switch
3TE3
3 T3 or 3 E3 software programmable interface plug-in card
7FOM
7-port Fiber Optical Interface with 7 SFP housings (SFP not included)
1FOMB
1-port Fiber Optical Interface
RTB
RTB card
3E1
3-port E1 card
3T1
3-port T1 card
2GH
2-port G.SHDSL card
4GH
4-port G.SHDSL card
TDMoE
TDMoE card
12/24FXS
12/24 FXS card
12/24FXO
12/24 FXO card
8E&M
8-port E&M card
8RS232
8 RS232 card
8DBRA
8 Data Bridge A card
Conference
Conference card
OCUDPA
8 channel OCU DP card
6V.36A
6-port V.36 card
6V.35A
6-port V.35 card
X.21/V.11
6-port X.21 card
6EIA530/6RS449
6-port EIA530/RS449 card
Example:
Loop-O9500-R-CHA-G, Loop-O9500-R-CBA-G, Loop-O9500-R-FANA-G, Loop-O9500-R-CC4-G,
Loop-O9500-R-63TE-G, Loop-O9500-4E1-RJ, Loop-O9500-R-4GH, Loop-O9500-R-SD48:
For modelO9500 6U height Rack chassis with one CPU card, one connect board, and one Fan board, one 63E1 software
programmable interface plug-in card, one 4-channel E1 interface with RJ48C connectors, one 4-channel G.SHDSL
plug-in card (1-pair), and a single –48 Vdc power module.

Loop-O9500 SDH/SONET IMAP
SDH/SONET-MSTP
15
Loop-O9500R SDH/SONET IMAP Product Specification
High Speed or High Density Tributary Modules
Max. Number of Aggregate Lines on Controller Modules
4 STM-1/4 (OC-3/12) aggregate optical lines or
4 STM-1/4/16 (OC-3/12/48) aggregate optical lines (CC16)
Max. Number of HS Tributary Lines for CC4 Controller Module
1 STM-4 (OC-12) tributaries without protection
6 STM-1 (OC3) tributaries without protection
12 E3/T3 tributaries without protection
252 E1/T1 tributaries without protection
4 GbE +32 FE EoS with build in L2 switch tributaries without protection
4 GbE or 32 FE EoS without build in L2 switch tributaries without protection
28 FOM tributaries without protection
Max. Number of HS Tributary Lines for CC16 Controller Module
4 STM-4 (OC-12) tributaries without protection
8 STM-1 (OC3) tributaries without protection
12 E3/T3 tributaries without protection
252 E1/T1 tributaries without protection
4 GbE +32 FE EoS with build in L2 switch tributaries without protection
4 GbE or 32 FE EoS without build in L2 switch tributaries without protection
8 GbE EoS with build in L2 switch tributaries without protection with backplane capacity up to 2.5G
28 FOM tributaries without protection
T1 Interface
Line Rate
1.544 Mbps 32 ppm
Jitter
ITU G.824
Line Code
AMI/B8ZS
Framing
Unframed with a framing monitor on
receiving side
Input Signal
ITU G.703 DSX-1 0dB to –6dB
Impedance
100 ohm twisted pair
Output
Signal
ITU G.703 DSX-1 w/short (0-110, 110-220,
220-330, 330-440, 440-550, 550~660 (feet)
Connector
SCSI-II 68-pin
One connector for 16 ports
Two connectors for 32 ports
Four connectors for 63 ports
Output
Mask
Bellcore GR-499-core
E1 Interface
Line Rate
2.048 Mbps 50 ppm
Jitter
ITU G.823
Line Code
AMI/HDB3
Framing
Unframed with a framing monitor
on receiving side
Input Signal
ITU G.703
Impedance
75 ohm coax/120twisted pair
Output Signal
ITU G.703
Connector
SCSI-II 68-pin
One connector for 16 ports
Two connectors for 32 ports
Four connectors for 63 ports
Output Mask
ETS 300 689 Sec.4.2.1.2 ITU G.703
E3 Interface
Line Rate
34.368 Mbps ± 20ppm
Jitter
ITU G.823
Line Code
HDB3
Framing
Unframed, G.751
Input Signal
ITU G.703
Impedance
75 ohm coax
Output Signal
ITU G.703
Connector
BNC connector
Output Mask
ETS 300 689 Sec.4.2.1.2 ITU G.703
T3 interface
Line Rate
44.736 Mbps ± 20ppm
Jitter
ITU G.824
Line Code
B3ZS
Framing
Unframed, M13/Mx3 (unframed
E1/T1), G.747
Input Signal
ITU G.703
Impedance
75coax
Output Signal
ITU G.703
Connector
BNC connector
Output Mask
Bellcore GR-499-core

Loop-O9500 SDH/SONET IMAP
SDH/SONET-MSTP
16
Fast Ethernet interface
Line Rate
10/100M bps
Mapping
n x VC12, n x VC3, or n x VC4
Layer2 Protocol
RSTP (802.1W),
Connector
RJ45
VLAN (802.1Q, 802.1P)
Flow Control (802.3X)
MSTP (802.1S)
IGMP Snooping
QoS
Prrocess Protocol
VCAT, GFP(G.7041), LAPS,
LCAS(G.7042), and non-LCAS
Gigabit Ethernet interface
Line Rate
10/100/1000Mbps
Mapping
n x VC12, n x VC3, or n x VC4
Layer2 Protocol
RSTP (802.1W),
Connector
RJ45
VLAN (802.1Q, 802.1P)
Flow Control (802.3X)
MSTP (802.1S)
IGMP Snooping
QoS
Process Protocol
VCAT, GFP(G.7041), LAPS,
LCAS(G.7042), and non-LCAS
7 FOM
Port number
7
Source
Laser
Line Code
Scrambled NRZ
Wavelength
1310 50 nm, 1550 40 nm
Optical Line Rate
38.84Mbps
Connector
SFP housing with LC type
Reach
2~240 Km
(For more detail, please refer to the SFP table
below)
Protection
1+1 Line Protection
1FOMB
Source
MLM Laser
Line Code
Scrambled NRZ
Wavelength
1310 50 nm, 1550 40 nm
Detector Type
PIN-FET
50 Km reach
NOTE: Longer or shorter, 15 to 120Km, on special order.
Diagnostics Test
Optical Fiber
Local and remote loopbacks
E1 Link
Local and remote loopback, send test pattern
Low Speed Tributary Modules
Network Line Interface –4E1
Line Rate
2.048 Mbps 50 ppm
Framing
ITU G.704
Line Code
AMI or HDB3
Connector
BNC/RJ48C
Input Signal
ITU G.703
Electrical
75 ohm Coax/120 ohm twisted pair
Output Signal
ITU G.703
Jitter
ITU G.823
Network Line Interface - 4T1
Line Rate
1.544 Mbps 32 ppm
Output Signal
DSX1w/0, -7.5, -15 dB LBO
Line Code
AMI or B8ZS
Framing
D4/ESF (selectable)
Input Signal
DSX-1 0 dB to -30 dB w/ALBO
Connector
RJ48C
Network Line Interface - 3E1
Line Rate
2.048 Mbps 50 ppm
Framing
ITU G.704
Line Code
AMI or HDB3
Connector
BNC/RJ48C
Input Signal
ITU G.703
Electrical
75 ohm Coax/120 ohm twisted pair
Output Signal
ITU G.703
Jitter
ITU G.823
Function
Support DS0-SNCP
Network Line Interface –3T1

Loop-O9500 SDH/SONET IMAP
SDH/SONET-MSTP
17
Line Rate
1.544 Mbps 32 ppm
Framing
D4/ESF
Line Code
AMI/B8ZS
Output Signal
DSX-1 w/0, -7.5, -15 dB LBO
Input Signal
DSX-1 0dB to -30dB w/ALBO
Connector
RJ48C
Jitter
AT&T TR 62411
Pulse Template
AT&T TR 62411
Data Rate
n * (64) Kbps (n = 1 to 24)
Surge Protection
FCC Part 68 Sub Part D
G.shdsl Line Interface (2GH/4GH)
Number of ports
2 or 4
Line Rate for 4-channel G.shdsl
n x 64Kbps (n= 3 to 31)
Line Rate for 2-channel G.shdsl
n x 64Kbps (n= 3 to 15)
Line Code
16-TCPAM, full duplex with adaptive echo cancellation
Connector
RJ45
Electrical
Unconditioned 19-26 AWG twisted pair
Sealing current
Max. 20 MA source current
Clock Source
From System, Line
Diagnostic Test
G.SHDSL Loopback: To-LINE, To-bus
BERT: QRSS
DTE(X.21/V.11) Interface (6X21A)
Data Port
Up to six 6-port DTE X.21 card; 1-port DTE X.21 card
Data Rate
56 or 64 Kbps, n = 1 to 32
Connector
DB15
DTE (V.35/ V.36) Interface (6V35A/6V36A)
Data Port
Up to six 6-port DTE V.35/ V.36 cards
Data Rate
56 or 64 Kbps, n = 1 to 32
Connector
For V.35 card: DB25S (optional conversion cable DB25Sto M34 connector)
For V.36 card::DB25S (optional conversion cable DB25Sto DB37 connector)
DTE (EIA530/RS449) Interface (6 EIA530A/6RS449A)
Data Port
Up to six 6-port EIA530 DTE card
Data Rate
56 or 64 Kbps, n = 1 to 32
Connector
DB25S (optional conversion cable DB25S male to DB37 female connector for RS449)
C37.94 Interface (1/4C37)
Source
LED
Wavelength
820nm 2Km reach
Connector
ST
Optical Budget
50 Mircon core/9.6 db
62.5 Mircon core/ 15db
Dry Contact I/O card (8DC)
Inputs -
Outputs -
8-channel
2-port per card, 4-pair per port
8-channel
8-pair per card
Connector
RJ45
Connector
Screw type
Internal Resistance
1 K
Initial Insulation Resistance
Min. 100M ohm (at 500 Vdc)
Activation Current
3 ma
Max. Current
5A
Deactivation Current
1.5 ma
Max. Voltage
100 Vdc, 250 Vac
Allowable Current
4 ma
Dry Contact Type B Interface
Inputs -
Outputs -
8-channel
2-port per card, 4-pair per port
8-channel
8-pair per card
Connector
RJ45
Connector
Screw type
Internal Resistance
100 K
Initial Insulation Resistance
Min. 1000M ohm (at 500 Vdc)
Activation Current
3 ma
Max. Current
2A
Deactivation Current
1.5 ma
Max. Voltage
220 Vdc, 250 Vac
Allowable Current
4 ma
Co-directional (G.703) card
Interface
ITU G.703 64 Kbps co-directional interface
Connector
120ohm, RJ48
Line Distance
Up to 500 meters
Loopback
DTE Payload Loopback, Local Loopback
Router-B Interface (RTB)
Number of ports
8 LAN ports, Max. 64 WAN ports. Each WAN port has data rate n x 64K bps, 1n 32
(8Mbps for total of all 64 WAN ports

Loop-O9500 SDH/SONET IMAP
SDH/SONET-MSTP
18
Physical Interface
10/100 BaseT x 8
Connector
RJ45
Routing protocol
RIP-I, RIP-II, OSPF, Static
Supporting Protocols
PPP (IPCP/BCP), MLPPP, HDLC, Frame Relay, and Cisco compatible HDLC, NAT/NAPT,
DHCP
Diagnostic
Ping, Trace route
QoS
Rate limit
DTE(RS232-X.50 mux. 8-port) Interface (RS232)
Data Port
Up to twelve 8-port RS232 cards
MUX
Maximum 5 subrate port per 64K bps
Data Rate
Asynchronous
Mux mode
0.6K, 1.2K, 2.4K, 4.8K, 9.6K
Independent mode
0.6K, 1.2K, 2.4K, 4.8K, 9.6K, 19.2K, 38.4K
Synchronous
Mux mode
0.6K, 1.2K, 2.4K, 4.8K, 9.6K
Independent mode
0.6K, 1.2K, 2.4K, 4.8K, 9.6K, 19.2K, 38.4K, 48K, 64K
Card Type
Port Number
1
2
3
4
5
6
7
8
Eight RJ48
Async
Async
Async
Async
Async
Async
Async
Async
Two DB44 + Two RJ48
Async/Sync
Async/Sync
Async
Async/Sync
Async/Sync
Async
Async
Async
Connector
Eight RJ48 (port 1 to port 8)
DB44 (port1,port2,port3), DB44 (port4,port5,port6), RJ48 (port7) and RJ48(port8)
Conversion Cable
Athree-into-one conversion cable adapts the DB44 connector to 3 connecters (one DB9S andtwo
DB25S)
Electrical
RS232 Interface, DCE
Data Bridge Card
Data Port
Up to twelve 8-port data bridge card (each card supports up to 120 DS0 for data bridge)
Feature
20 end points per multi-drop circuit to into a logical ended 56K or 64K channel
Per port supports bridge function to N remote Trib. Site (N=1~20)
Data Rate
Asynchronous
Support to receive 1200 to 19200 bps asynchronous data via oversampling
channel
Bridge function
one port with one DS-0 to many (Maximum is 20 for remote Tributary data box )
20 drops for each DS0 to remote Tributary data box and 8 ports RS232 shared the 128 channels.
8UDTEA (RS232/RS422/RS485) Universal Data Interface Card
Data Port
8 port UDTE card
ASYNC Data Rate
200,300, 600, 1200, 2400, 4800, 9600, 19.2K, 38.4K, 57.6K, 115.2K, 128K bps by
oversampling
Connector
RJ48C
Interface
DCE only
Flow Control (RS232 only)
Hardware (RTS and DTR), none
Loopback function
DTE to DTE loopback;
DTE to Line loopback
Voice Card 12 MAG (Magneto)
Connector
Twelve RJ11
Alarm Conditioning
CGAbusy after 2.5 seconds of LOS, LOF
Encoding
A-law or -law, user selectable together for all
Impedance
Balanced 600 or magneto telephone impedance match
Longitudinal Conversion Loss
> 46dB
Gain Adjustment
-21 to +10 dB / 0.1dB step transmit & receive
Signal/ Distortion
> 25dB with 1004 Hz, 0dBm input
Frequency Response
- 0.25 to -1 dB from 300 to 3400 Hz, coincide with ITU-TG.712
Idle Channel Noise
Max. –65 dBm0p
Min Detectable Ringing Voltage
16 Vrms
Ringing Detectable Across
L1 and L2 (Tip and Ring), L1 andGND (Tip and GND)
Ringing Generation
Voltage: 76 Vrms (sine wave)
Frequency: 20Hz (with optional choices of 16, 25, 50 Hz)
Cadence:
1. Normal:
Ring after crank
2. PLAR ON:
-Single Ring Type: ring for 2 sec. and stop, or ring for 4 sec. and stop

Loop-O9500 SDH/SONET IMAP
SDH/SONET-MSTP
19
-Continuous Ring Type: 1 sec on 2 sec off, or 2 sec on 4 sec off
Ringing SendAcross
L1 and L2 (Tip and Ring), L1 andGND (Tip and GND)
Signaling
Magneto MRD(Ringing across Tip and Ring or Tip and Ground)
Signaling Bit A,B,C,D
Programable
Signaling is carried transparently by the digitizing process.
Use Magneto card default setting for communications between magneto telephones
Use Magneto card PLAR mode setting for communications between a magneto telephone and a regular telephone
Voice Card- E&M
Connector
Eight RJ45
Alarm Conditioning
CGA busy after 2.5 seconds of LOS, LOF
Encoding
A-law or -law, user selectable together for all
Impedance
Balanced 600 or 900 ohms
Longitudinal Conversion Loss
> 46dB
Longitudinal Balance
> 63dB
Gain Adjustment (Per-port setting)
-10 to +7 dB / 0.1dB step for transmit (D/A) gain
-10 to +14 dB / 0.1dB step for receive (A/D) gain
I/O voice power range
A/D digital input level: -66 dBm (0.00039 Vrms) ~ + 3 dBm (1.09 Vrms)
D/A analog output level: -66 dBm (0.00039 Vrms) ~ + 7 dBm (1.74 Vrms)
Signal/Distortion
> 25dB with 1004 Hz, 0dBm input
Frequency Response
- 0.25 to -1 dB from 300 to 3400 Hz
Carrier connection
Side A ( exchange side) and Side B (carrier side) setup by side switch
Idle Channel Noise
Max. –65 dBm0p
wire mode
2 wire and 4 wire (programmable)
Signaling
Type 1, Type 2, Type 3, Type 4, and Type 5, Transmit only (programmable)
Modems
Full compatibility with V.90 modems
All in-band signaling tones are carried transparently by the digitizing process.
Customer is responsible for in-band signaling compatibility between a telephone and a switch, or between a PBX and a
switch.
Voice Card (12FXS, 12FXO, 24FXS, 24FXO)
12 FXS/FXO Connector
Twelve RJ11
24 FXS/FXO Connector
One RJ21X femail connector
Alarm Conditioning
CGA busy after 2.5 seconds of LOS, LOF
Encoding
A-law or -law, user selectable together for all
AC Impedance
Balanced 600 or 900 ohms (selectable together for all)
Longitudinal Conversion
Loss
> 46dB
Cross talk measure
Max -70dBm0
Gain Adjustment
FXS: -21 to +3 dB / 0.1dB step transmit & receive
FXO: -21 to +10 dB / 0.1dB step transmit & receive
Signal/ Distortion
> 25dB with 1004 Hz, 0dBm input
Frequency Response
- 0.25 to -1 dB from 300 to 3400 Hz, coincide with ITU-T G.712
Idle Channel Noise
Max. –65 dBm0p
Variation of Gain
±0.5dB
FXO
Ringing REN
0.5B (AC)
Detectable Ringing
25 Vrms
Loop Resistance
1800
DC Impedance (ON-HOOK)
> 1M
DC Impedance (OFF-HOOK)
235 @ 25mAfeed
90 @ 100mAfeed
FXS Loop Feed
-48Vdc with 25mA current limit per port
Jumper Selectable: 25mA(default=25mA), 30mA, or 35mA(sn=S1)
FXS Signalling
Normal / PLAR: Private LineAuto Ring down
FXS Ringing
1 REN at 5K meters per port
16.7Hz, 20Hz, 25Hz, 50Hz, user selectable for all ports
Jumper selectable: 64, 76, and 85 Vrms (triangle wave), (default= 76 Vrms for Ring Voltage)
2 sec on 4 sec off, or 1 sec on 2 sec off optional for PLAR ON
FXS Tone
Alarm Tone: 480Hz/620Hz/-24dBm
Ring Back Tone: 440Hz/480Hz/-19dBm
FXS functions
Basic functions: Bettary Reverse, Loop Star, PLAR
Optional functions: PLAR ON/PLAR bit programmable, Ground Start, and/or Meter Pulse.
Signaling Bit A,B,C,D
Programable bit
All in-band signaling tones are carried transparently by the digitizing process.
Customer is responsible for in-band signaling compatibility between a telephone and a switch, or between a PBX and a
switch.

Loop-O9500 SDH/SONET IMAP
SDH/SONET-MSTP
20
OCU/DP Interface
Ports
8 Ports for each card
Line Status Indicator
Per Port 1 dual color LED; Red for LOS, Green for SYNC
Network Connector
RJ48S
Electrical network connection
Tip/Ring and Tip1/Ring1
Transmit Source Impedance
135 Ohms +/- 20%
Receive Input Impedance
135 Ohms +/- 20%
Receiver Sensitivity/ Dynamic Range
0 to 43 dB loop loss at 72K & 56K
0 to 34 all other rates Automatic line equalization
Pulse Amplitude
+/- 1.5 V (+/- 10%) peak, all rates except 9.6k
+/- 0.75 V (+/- 10%) peak at 9.6k
Bipolar Return to zero, 50% duty cycle
Sealing Current
Typically 16 mA DC
Operating Modes
4-wire DDS
Switched 56 support is optional.
Circuit Rates
SYNC: 2.4, 4.8, 9.6, 19.2, 56, 72kbps (64k) clear channel
Conforms with AT&T Pub 41458
Encoding and decoding rules
Use bipolar violation to indicate control information: Idle, out of service,
Zero substitution using unframed loops
Maintenance control
Fault and Performance
DSU Non-latching loop-back code (for 2.4, 4.8, 9.6, 19.2, 56k circuit
rate)
DSU Latching loop-back (TIP, LSC, LBE, FEV) code (for 72k circuit
rate)
Machine maintenance OCU/DP card operation:
Payload loopback
OCU loopback
Local loopback
Bi-directional loopback
V.54 remote loopback code
Custom defined remote loopback code
BERT test support all ones, all zeros, 2047, 511, 63 pattern.
LOS, OOS, ES, SES and UAS alarm.
Current, last 96 registry and 7 days performance storage.
Environment
Operating: 0-50°C
Storage: -25-75°C
Humidity: Up to 90% RH non-condensing
Specification Standard
ANSI T1.410; AT&T Pub 62319, AT&T Pub 62310, ITU-T V.54
Table of contents
Other Loop Telecom Wireless Access Point manuals
Popular Wireless Access Point manuals by other brands

Allnet
Allnet ALL1682511 user manual

Buffalo
Buffalo AirStation WLMR-L11G install guide

Ubiquiti
Ubiquiti LiteBeam LBE-5AC-LR quick start guide

D-Link
D-Link DAP-1620 Technical Support Setup Procedure

D-Link
D-Link AirPremier N DAP-3690 Quick install guide

Alcatel-Lucent
Alcatel-Lucent AOS-W 3.4 quick start guide

bintec elmeg
bintec elmeg W2022ac manual

Pakedge Device & Software
Pakedge Device & Software wap-c3n Installation quick guide

Alcatel-Lucent
Alcatel-Lucent 9364 Quick start installation guide

LevelOne
LevelOne WAP-3101 user manual

LiteOn
LiteOn WP8722 user manual

Cisco
Cisco 1700 series Hardware installation guide